NQB-100DWA-DANG-000-ESA [CUI]

FULLY REGULATED ADVANCED BUS CONVERTERS;
NQB-100DWA-DANG-000-ESA
型号: NQB-100DWA-DANG-000-ESA
厂家: CUI INC    CUI INC
描述:

FULLY REGULATED ADVANCED BUS CONVERTERS

文件: 总36页 (文件大小:2075K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
date 02/20/2013  
page 1 of 36  
SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
FEATURES  
• quarter-brick with  
GENERAL CHARACTERISTICS  
• configurable soft start/stop  
• precision delay and ramp-up  
• voltage margining  
digital PMBus interface  
57.9 x 36.8 x 11.3 mm  
(2.28 x 1.45 x 0.445 in)  
• voltage/current/temperature monitoring  
• configurable output voltage  
• configurable fault response  
• power good  
• industry standard 5-pins for  
intermediate bus architectures  
• industry-leading power density for  
telecom and datacom 127~141W / sq. in  
• high efficiency, typ. 96.4% at half load,  
12 Vout  
• fully regulated advanced bus converter  
from 36~75Vin  
• 2,250 Vdc input to output isolation  
• fast feed forward regulation to manage  
line transients  
• optional baseplate for high temperature  
applications  
• droop load sharing with 10% current  
share accuracy  
• PMBus Revision 1.2 compliant  
• 2.9 million hours MTBF  
• ISO 9001/14001 certified supplier  
• Ericsson BMR453 & BMR456 compatible  
input voltage  
output voltage  
output current  
output wattage  
MODEL  
max  
max  
(Vdc)  
(Vdc)  
12  
(A)  
(W)  
NQB-420DWA-AN  
NQB-468DMA-AN  
NQB-415DWB-AN  
NQB-462DMB-AN  
36~75  
40~60  
36~75  
40~60  
35  
39  
35  
39  
420  
468  
415  
462  
12  
12.45  
12.45  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 2 of 36  
PART NUMBER KEY  
NQB- XXX D X X - X X X X - XXX -ES X  
Base Number  
Engineering Phase:  
A~Z  
Design Output Power:  
1~999  
Engineering Sample:  
ES  
Digital Interface  
Firmware Configuration:  
000~ZZZ  
Input Voltage Range:  
W = wide (36~75 V)  
M = medium (40~60 V)  
Heatsink Option:  
"blank" = open frame  
H = heatsink flat  
L = heatsink lateral fins  
T = heatsink transverse fins  
G = heatsink with GND pin  
Nominal Output Voltage:  
A = 12.0 V  
B = 12.45 V  
C = 9.6 V  
D = 9.0 V  
E = 5.0 V  
Enable Logic Sense:  
N = negative logic  
P = positive logic  
Load Sharing Function:  
D = Vout droop  
Pin Description:  
A = 5.33 mm (0.210 in.)  
B = 4.57 mm (0.180 in.)  
C = 3.69 mm (0.145 in.)  
D = 2.79 mm (0.110 in.)  
S = SMT  
Packaging:  
Example part number: NQB-420DWA-AN-001  
20 converters(through hole pin)/tray, PE foam dissipative  
20 converters(surface mount pin)/tray, Antistatic PPE  
420 W output power, digital pins  
wide input voltage range, 12.0 V output  
5.33 mm pins, negative enable logic  
firmware revision 001  
CONTENTS  
Part Number Key........................................................2 EMC Specification.........................................20  
General Information...................................................3 Operating Information...................................21  
Safety Specification....................................................3 Thermal Consideration..................................24  
Absolute Maximum Ratings..........................................4 Connections............................................25  
PMBus Interface...........................................26  
Electrical Specification:  
Mechanical Information.................................29  
Soldering Information...................................32  
Delivery Package Information.........................33  
Product Qualification Specification...................35  
12V,35A,420W,36~75Vin; NQB-420DWA-AN....................6  
12V,39A,468W,40~60Vin; NQB-468DMA-AN...................10  
12.45V,35A,415W,36~75Vin; NQB-415DWB-AN...............14  
12.45V,39A,462W,40~60Vin; NQB-420DMB-AN...............19  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 3 of 36  
General Information  
Reliability  
the requirements of all applicable safety standards and  
regulations for the final product.  
The failure rate (λ) and mean time between failures  
(MTBF= 1/ λ) is calculated at max output power and  
an operating ambient temperature (TA) of +40°C. CUI  
Power Modules uses Telcordia SR-332 Issue 2 Method 1 to  
calculate the mean steady-state failure rate and standard  
deviation (σ).  
Component power supplies for general use should comply  
with the requirements in IEC/EN/UL 60950 1 Safety  
of Information Technology Equipment. Product related  
standards, e.g. IEEE 802.3af Power over Ethernet, and  
ETS 300132 2 Power interface at the input to telecom  
equipment, operated by direct current (dc) are based on  
IEC/EN/UL 60950 1 with regards to safety.  
Telcordia SR-332 Issue 2 also provides techniques to  
estimate the upper confidence levels of failure rates based  
on the mean and standard deviation.  
CUI Power Modules DC/DC converters and DC/DC  
regulators are UL 60950 1 recognized and certified in  
accordance with EN 60950 1. The flammability rating for  
all construction parts of the products meet requirements  
for V 0 class material according to IEC 60695 11 10, Fire  
hazard testing, test flames – 50 W horizontal and vertical  
flame test methods.  
Mean steady-state failure rate, λ Std. deviation, σ  
421 n Failures/h  
60.9 nFailures/h  
MTBF (mean value) for the NQB series = 2.9 Mh.  
MTBF at 90% confidence level = 2.4 Mh  
Compatibility with RoHS requirements  
Isolated DC/DC converters  
The products are compatible with the relevant clauses  
and requirements of the RoHS directive 2011/65/EU and  
have a maximum concentration value of 0.1% by weight  
in homogeneous materials for lead, mercury, hexavalent  
chromium, PBB and PBDE and of 0.01% by weight in  
homogeneous materials for cadmium.  
Galvanic isolation between input and output is verified  
in an electric strength test and the isolation voltage  
(Viso) meets the voltage strength requirement for basic  
insulation according to IEC/EN/UL 60950-1.  
It is recommended to use a slow blow fuse at the input  
of each DC/DC converter. If an input filter is used in the  
circuit the fuse should be placed in front of the input filter.  
In the rare event of a component problem that imposes a  
short circuit on the input source, this fuse will provide the  
following functions:  
Exemptions in the RoHS directive utilized in CUI  
Power Modules products are found in the Statement of  
Compliance document.  
Safety Specification  
Reliability  
Isolate the fault from the input power source so as  
not to affect the operation of other parts of  
the system  
CUI Power Modules DC/DC converters and DC/DC  
regulators are designed in accordance with the safety  
standards IEC 60950 1, EN 60950 1 and UL 60950 1  
Safety of Information Technology Equipment.  
Protect the distribution wiring from excessive  
current and power loss thus preventing hazardous  
overheating  
The DC/DC converter output is considered as safety extra  
low voltage (SELV) if one of the following conditions is  
met:  
IEC/EN/UL 60950 1 contains requirements to prevent  
injury or damage due to the following hazards:  
Electrical shock  
Energy hazards  
Fire  
Mechanical and heat hazards  
Radiation hazards  
Chemical hazards  
The input source has double or reinforced  
insulation from the AC mains according to IEC/EN/  
UL 60950-1  
The input source has basic or supplementary  
insulation from the AC mains and the input  
of the DC/DC converter is maximum 60  
Vdc and connected to protective earth according to  
IEC/EN/UL 60950-1  
On-board DC/DC converters and DC/DC regulators are  
defined as component power supplies. As components  
they cannot fully comply with the provisions of any  
safety requirements without “conditions of acceptability.  
Clearance between conductors and between conductive  
parts of the component power supply and conductors on  
the board in the final product must meet the applicable  
safety requirements. Certain conditions of acceptability  
apply for component power supplies with limited stand-off  
(see Mechanical Information for further information). It is  
the responsibility of the installer to ensure that the final  
product housing these components complies with  
The input source has basic or supplementary  
insulation from the AC mains and the DC/DC  
converter output is connected to protective earth  
according to IEC/EN/UL 60950-1  
Non - isolated DC/DC regulators  
The DC/DC regulator output is SELV if the input source  
meets the requirements for SELV circuits according to IEC/  
EN/UL 60950-1.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 4 of 36  
Absolute Maximum Ratings  
parameter  
conditions/description  
min  
-40  
-55  
typ  
max  
+125  
+125  
units  
°C  
operating temperature (TP1)  
storage temperature (TS)  
see thermal consideration section  
°C  
+80  
+65*  
input voltage (VI)  
-0.5  
V
Vdc  
V
isolation voltage (Viso)  
input voltage transient (Vtr)  
input to output test voltage, see note 1  
2250  
according to ETSI EN 300 132-2 and Telcordia GR-  
1089-CORE  
+100  
+80*  
remote control pin voltage (VRC) see operating information section  
-0.3  
-0.3  
18  
V
SALERT, CTRL, SCL, SDA, SA0,  
SA1 (V Logic I/O)  
3.6  
V
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one  
parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified  
manner.  
Note  
1: Isolation voltage (input/output to base-plate) max 750 Vdc.  
* Applies for the narrow input version VI= 40-60 V  
Fundamental Circuit Diagram  
+IN  
+OUT  
-OUT  
-IN  
Auxillary  
Supply  
Driver  
Control  
RC  
RC isolation  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 5 of 36  
Functional Description  
TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: TP1, TP3 = +25°C, VI= 53 V, max IO , unless otherwise specified under Conditions  
Configuration File: 190 10-CDA 102 0314/001  
parameter  
conditions/description  
min  
typ  
max  
units  
PMBus monitoring accuracy  
input voltage (VIN_READ)  
output voltage (VOUT_READ)  
-2  
±0.2  
±0.1  
2
%
%
VI = 53V  
-1.0  
1.0  
VI = 53V, 50-100% of max IO  
VI = 53V, 10% of max IO  
-6  
-0.6  
±0.15  
6
0.6  
%
A
output current (IOUT_READ)  
temperature (TEMP_READ)  
-5  
±3.5  
5
ºC  
fault protection  
characteristics  
factory default  
setpoint accuracy  
hysteresis: factory default  
hysteresis: configurable via PMBus of threshold  
range, note 1  
33  
2
V
%
V
-2  
0
2
input under voltage lockout  
(UVLO)  
V
delay  
300  
0
μs  
output voltage - under voltage  
protection (VOUT_UV_FAULT_  
LIMIT)  
factory default  
configurable via PMBus, note 1  
fault response time  
V
V
μs  
0
16  
16  
200  
output voltage - over voltage  
protection (VOUT_OV_FAULT_  
LIMIT)  
factory default  
configurable via PMBus, note 1  
fault response time  
15.6  
V
V
μs  
VOUT  
200  
41  
setpoint accuracy (IO)  
-6  
0
6
%
A
A
IOUT_OC_FAULT_LIMIT factory default  
IOUT_OC_FAULT_LIMIT, configurable via PMBus,  
note 1  
over current protection (OCP)  
100  
fault response time  
200  
125  
μs  
OTP_FAULT_LIMIT, factory default  
OTP_FAULT_LIMIT, configurable via PMBus, note 1  
hysteresis, factory default  
hysteresis, configurable via PMBus, note 1  
fault response time  
ºC  
ºC  
ºC  
ºC  
μs  
-50  
0
125  
125  
over temperature protection  
(OTP)  
10  
300  
logic input/output  
characteristics  
logic input low (VIL)  
logic input high (VIH)  
CTRL, SA0, SA1, PG, SCL, SDA  
CTRL, SA0, SA1, PG, SCL, SDA  
1.1  
V
V
2.1  
CTRL, PG, SALERT, SCL, SDA  
IOL = 6 mA  
logic output low (VOL)  
0.25  
V
CTRL, PG, SALERT, SCL, SDA  
IOH = -6 mA  
logic output high (VOH)  
bus free time T(BUF)  
2.7  
1.3  
V
note 2  
μs  
Note  
1: See Operating Information section.  
2: PMBus timing parameters according to PMBus spec.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 6 of 36  
Electrical Specification  
12.0 V, 35 A, 420 W  
TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.5 mF, Configuration File: 19010-CDA 102 0314/001  
parameter  
conditions/description  
min  
36  
typ  
max  
75  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
32  
33  
35  
18  
34  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
34  
36  
V
μF  
W
0
420  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.2  
95.5  
96.4  
95.5  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
max IO  
19.8  
3.3  
29.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0.4  
W
default switching frequency (fs) 0-100% of max IO  
output voltage initial setting  
and accuracy (VOi)  
133  
11.88  
4.0  
140  
147  
12.12  
13.2  
kHz  
TP1 = +25°C, VI = 53 V, IO = 35 A  
12.0  
V
V
V
output adjust range (VO)  
see operating information  
0-100% of max IO  
output voltage tolerance band  
(VO)  
11.76  
12.24  
line regulation (VO)  
load regulation (VO)  
max IO  
21  
6
55  
40  
mV  
mV  
VI = 53 V, 0-100% of max IO  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
8
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
24  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3.6  
7
ms  
s
RC start-up time (tRC)  
max IO  
12  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
5.1  
7
ms  
s
output current (IO)  
0
35  
44  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1, TP3 = 25ºC, see Note 1  
37  
41  
12  
recommended capacitive load  
(Cout)  
TP1, TP3 = 25ºC, see Note 2  
0.1  
3.5  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
60  
150  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 7 of 36  
Typical Characteristics  
12.0 V, 35 A / 420 W  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
24  
20  
16  
12  
8
95  
90  
85  
80  
36 V  
48 V  
53 V  
36 V  
48 V  
53 V  
75 V  
75 V  
4
75  
0
0
5
10  
15  
20  
25  
30  
35 [A]  
0
5
10  
15  
20  
25  
30  
35 [A]  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12.2  
11.0  
9.0  
7.0  
5.0  
3.0  
12.1  
36 V  
48 V  
53 V  
75 V  
36V  
48V  
53V  
75V  
12.0  
11.9  
11.8  
0
5
10  
15  
20  
25  
30  
35 [A]  
35  
37  
39  
41  
43  
45 [A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 8 of 36  
Typical Characteristics  
12.0 V, 35 A / 420 W  
Start-up  
Shut-down  
Start-up enabled by connecting VI at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 35 A resistive load.  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Shut-down enabled by disconnecting VI at: Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (2 ms/div.).  
TP1, TP3 = +25°C, VI = 53 V,  
IO =35 A resistive load.  
Output Ripple & Noise  
Output Load Transient Response  
Output voltage ripple at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 35 A resistive load.  
Trace: output voltage (50 mV/div.).  
Time scale: (2 µs/div.).  
Output voltage response to load current  
step-change (8.75-26.25-8.75 A) at:  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.5 mF.  
Top trace: output voltage (0.5 V/div.).  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
Input Voltage Transient Response  
Output voltage response to input voltage  
transient at: TP1, TP3 = +25°C, VI = 36-75 V,  
IO = 17 A resistive load, CO = 3.5 mF  
Top trace: output voltage (2 V/div.).  
Bottom trace: input voltage (20 V/div.).  
Time scale: (0.5 ms/div.).  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 9 of 36  
Typical Characteristics  
12.0 V, 35 A / 420 W  
Output Current Derating – Open frame  
[A]  
35  
3.0 m/s  
2.0 m/s  
30  
25  
20  
15  
10  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
5
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
35  
[°C/W]  
6
3.0 m/s  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Con v.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested in  
wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
35  
A
40  
35  
30  
25  
20  
15  
10  
5
3.0 m/s  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
Ta mb  
85 °C  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [°C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 10 of 36  
Electrical Specification  
12.0 V, 39 A / 468 W  
TP1, TP3 = -40 to +90ºC, VI = 40 to 60 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.9 mF, Configuration File: 19010-CDA 102 0314/002  
parameter  
conditions/description  
min  
40  
typ  
max  
60  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
36  
37  
39  
18  
38  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
38  
40  
V
μF  
W
0
468  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.7  
95.7  
96.8  
95.6  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
max IO  
21.2  
2.8  
30.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0.4  
W
default switching frequency (fs) 0-100% of max IO  
133  
11.88  
4.0  
140  
147  
12.12  
13.2  
kHz  
output voltage initial setting  
and accuracy (VOi)  
TP1 = +25°C, VI = 53 V, IO = 39 A  
12.0  
V
V
V
output adjust range (VO)  
see operating information  
0-100% of max IO  
output voltage tolerance band  
(VO)  
11.76  
12.24  
line regulation (VO)  
load regulation (VO)  
max IO  
31  
5
60  
25  
mV  
mV  
VI = 53 V, 1-100% of max IO  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
8
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
24  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3
7
ms  
s
RC start-up time (tRC)  
max IO  
12  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
4.5  
7
ms  
s
output current (IO)  
0
39  
47  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1 = 25ºC, see Note 1  
41  
44  
14  
recommended capacitive load  
(Cout)  
TP1 = 25ºC, see Note 2  
0.1  
3.9  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
50  
110  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 11 of 36  
Typical Characteristics  
12.0 V, 39 A / 468 W  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
25  
20  
15  
10  
5
95  
90  
85  
80  
40 V  
48 V  
53 V  
60 V  
40 V  
48 V  
53 V  
60 V  
0
75  
0
5
10  
15  
20  
25  
30  
35  
40 [A]  
0
5
10  
15  
20  
25  
30  
35  
40 [A]  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12.2  
11.0  
9.0  
7.0  
5.0  
3.0  
12.1  
12.0  
11.9  
11.8  
40 V  
48 V  
53 V  
60 V  
40V  
48V  
53V  
60V  
0
5
10 15  
20 25 30  
35 40 [A]  
39  
41  
43  
45  
47 [A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 12 of 36  
Typical Characteristics  
12.0 V, 39 A / 468 W  
Start-up  
Shut-down  
Start-up enabled by connecting VI at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 39 A resistive load.  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Shut-down enabled by disconnecting VI at: Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (2 ms/div.).  
TP1, TP3 = +25°C, VI = 53 V,  
IO =39 A resistive load.  
Output Ripple & Noise  
Output Load Transient Response  
Output voltage ripple at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 39 A resistive load.  
Trace: output voltage (50 mV/div.).  
Time scale: (2 µs/div.).  
Output voltage response to load current  
step-change (9.75-29.25-9.75 A) at:  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.9 mF.  
Top trace: output voltage (0.5 V/div.).  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
Input Voltage Transient Response  
Output voltage response to input voltage  
transient at: TP1, TP3 = +25°C, VI = 40-60 V,  
IO = 19,5 A resistive load, CO = 3.9 mF  
Top trace: output voltage (2 V/div.).  
Bottom trace: input voltage (20 V/div.).  
Time scale: (0.5 ms/div.).  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 13 of 36  
Typical Characteristics  
12.0 V, 39 A / 468 W  
Output Current Derating – Open frame  
[A]  
40  
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
40  
[°C/W]  
6
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Conv.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested  
in wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base Plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
40  
A
40  
35  
30  
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
25  
20  
15  
10  
5
Ta mb  
85 °C  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [° C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 14 of 36  
Electrical Specification  
12.45 V, 35 A / 415 W  
TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.9 mF, Configuration File: 19010-CDA 102 0314/014  
parameter  
conditions/description  
min  
36  
typ  
max  
75  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
32  
33  
35  
18  
34  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
34  
36  
V
μF  
W
0
415  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.2  
95.5  
96.4  
95.5  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
max IO  
19.5  
3.2  
29.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0.4  
W
default switching frequency (fs) 0-100% of max IO  
133  
12.415  
4.0  
140  
147  
12.485  
13.2  
kHz  
output voltage initial setting  
and accuracy (VOi)  
TP1 = 25°C, VI = 53 V, IO = 0 A  
12.45  
V
V
V
output adjust range (VO)  
see operating information  
0-100% of max IO  
output voltage tolerance band  
(VO)  
11.5  
12.7  
line regulation (VO)  
load regulation (VO)  
max IO  
20  
55  
mV  
mV  
VI = 53 V, 0-100% of max IO  
500  
600  
700  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
23  
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
39  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3.6  
7
ms  
s
RC start-up time (tRC)  
max IO  
27  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
5.1  
7
ms  
s
output current (IO)  
0
35  
44  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1, TP3 = 25ºC, see Note 1  
37  
41  
12  
recommended capacitive load  
(Cout)  
TP1, TP3 = 25ºC, see Note 2  
0.1  
3.5  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
60  
150  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 15 of 36  
Typical Characteristics  
12.45 V, 63 A / 747 W, two products in parallel  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
45  
40  
35  
30  
25  
20  
15  
10  
5
95  
90  
85  
80  
36 V  
48 V  
53 V  
36 V  
48 V  
53 V  
75 V  
75 V  
75  
0
0
0
10  
20  
30  
40  
50  
60  
[A]  
10  
20  
30  
40  
50  
60  
[A]  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12 .5  
12 .4  
12 .3  
12 .2  
12 .1  
12 .0  
11.9  
11.0  
9.0  
36 V  
48 V  
53 V  
75 V  
36 V  
48 V  
53 V  
75 V  
7.0  
5.0  
3.0  
63 65 67 69 71 73 75 77 79 81 83 [A]  
11.8  
0
10  
20  
30  
40  
50  
60  
[A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
Start-up  
Output Load Transient Response  
Start-up enabled by connecting VI at:  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Output voltage response to load current Top trace: output voltage (0.5 V/div.).  
step-change (15.8-47.3-15.8 A) at:  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
TP1, TP3 = +25°C, VI = 53 V,  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.5 mF.  
IO = 63 A resistive load.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 16 of 36  
Typical Characteristics  
12.45 V, 35 A / 415 W  
Output Current Derating – Open frame  
[A]  
35  
3.0 m/s  
2.0 m/s  
30  
25  
20  
15  
10  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
5
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
35  
[°C/W]  
6
3.0 m/s  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Conv.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested in  
wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
35  
A
40  
35  
30  
25  
20  
15  
10  
5
3.0 m/s  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
Ta mb  
85 °C  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [°C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 17 of 36  
Electrical Specification  
12.45 V, 39 A / 462 W  
TP1, TP3 = -40 to +90ºC, VI = 40 to 60 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.9 mF, Configuration File: 19010-CDA 102 0314/017  
parameter  
conditions/description  
min  
40  
typ  
max  
60  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
36  
37  
39  
18  
38  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
38  
40  
V
μF  
W
0
462  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.7  
95.7  
96.8  
95.6  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
max IO  
21.0  
2.8  
30.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0.4  
W
default switching frequency (fs) 0-100% of max IO  
133  
12.415  
4.0  
140  
147  
12.485  
13.2  
kHz  
output voltage initial setting  
and accuracy (VOi)  
TP1 = 25°C, VI = 53 V, IO = 0 A  
12.45  
V
V
V
output adjust range (VO)  
see operating information  
0-100% of max IO  
output voltage tolerance band  
(VO)  
11.5  
12.7  
line regulation (VO)  
load regulation (VO)  
max IO  
31  
60  
mV  
mV  
VI = 53 V, 0-100% of max IO  
500  
600  
700  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
23  
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
39  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3
7
ms  
s
RC start-up time (tRC)  
max IO  
27  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
4.5  
7
ms  
s
output current (IO)  
0
39  
47  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1 = 25ºC, see Note 1  
41  
44  
14  
recommended capacitive load  
(Cout)  
TP1 = 25ºC, see Note 2  
0.1  
3.9  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
50  
110  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 18 of 36  
Typical Characteristics  
12.45 V, 70 A / 830 W, two products in parallel  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
45  
40  
35  
30  
25  
20  
15  
10  
5
95  
90  
85  
80  
40 V  
48 V  
53 V  
60 V  
40 V  
48 V  
53 V  
60 V  
75  
0
0
[A]  
70  
10  
20  
30  
40  
50  
60  
70 [A]  
0
10  
20  
30  
40  
50  
60  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12.5  
12.4  
12.3  
12.2  
12.1  
12.0  
11.0  
9.0  
7.0  
5.0  
3.0  
40 V  
48 V  
53 V  
60 V  
40 V  
48 V  
53 V  
60 V  
11.9  
11.8  
70  
75  
80  
85  
90 [A]  
0
10  
20  
30  
40  
50  
60  
70 [A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
Start-up  
Output Load Transient Response  
Start-up enabled by connecting VI at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 70 A resistive load.  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Output voltage response to load current Top trace: output voltage (0.5 V/div.).  
step-change (17.5-52.5-17.5 A) at:  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.9 mF  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 19 of 36  
Typical Characteristics  
12.45 V, 39 A / 462 W  
Output Current Derating – Open frame  
[A]  
40  
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
40  
[°C/W]  
6
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Conv.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested  
in wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base Plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
40  
A
40  
35  
30  
25  
20  
15  
10  
5
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
Ta mb  
85 °C  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [° C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 20 of 36  
EMC Specification  
Conducted EMI measured according to EN55022, CISPR  
22 and FCC part 15J (see test set-up). The fundamental  
switching frequency is 140 kHz for NQB at VI = 53 V, max  
IO.  
Conducted EMI Input terminal value (typ)  
Test set-up  
Layout recommendations  
The radiated EMI performance of the product will  
depend on the PWB layout and ground layer design.  
It is also important to consider the stand-off of  
the product. If a ground layer is used, it should  
be connected to the output of the product and the  
equipment ground or chassis.  
A ground layer will increase the stray capacitance  
in the PWB and improve the high frequency EMC  
performance.  
EMI without filter  
Optional external filter for class B  
Suggested external input filter in order to meet class B  
in EN 55022, CISPR 22 and FCC part 15J.  
Output ripple and noise  
Output ripple and noise measured according to figure  
below.  
Filter components:  
C1 = 1 μF  
C2 = 1 μF+220 μF  
0
C3 = 1 μF+220 μF  
C4  
L1  
L2  
C4,C5 = 2.2 nF  
L1 = 810 μH  
L2 = 810 μH  
+
+
C1  
C2  
C3  
R
Module  
-
-
C5  
0
Output ripple and noise test setup  
EMI with filter  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 21 of 36  
Operating information  
The device should be capable of sinking 0.7 mA. When the  
RC pin is left open, the voltage generated on the RC pin is  
max 6 V. The standard product is provided with “negative  
logic” remote control and will be off  
Power Management Overview  
This product is equipped with a PMBus interface. The  
product incorporates a wide range of readable and  
until the RC pin is connected to the  
configurable power management features that are simple  
to implement with a minimum of external components.  
Additionally, the product includes protection features that  
continuously safeguard the load from damage due to  
unexpected system faults. A fault is also shown as an alert  
on the SALERT pin. The following product parameters can  
continuously be monitored by a host: Input voltage, output  
voltage/current, duty cycle and internal temperature.  
-In. To turn on the product the  
voltage between RC pin and -In  
should be less than 1 V.  
To turn off the product the RC pin  
should be left open for a minimum  
of time 150 µs, the same time  
requirement applies when the product  
shall turn on. In situations where it is  
The product is delivered with a default configuration  
suitable for a wide range operation in terms of input  
voltage, output voltage, and load. The configuration is  
stored in an internal Non-Volatile Memory (NVM). All  
power management functions can be reconfigured using  
the PMBus interface. Please contact your local CUI Power  
Modules representative for design support of custom  
configurations or appropriate SW tools for design and  
down-load of your own configurations.  
desired to have the product to power up automatically  
without the need for control signals or a switch, the RC  
pin can be wired directly to –In or disabled via the 0xE3  
command. The logic option for the primary remote control is  
configured via 0xE3 command using the PMBus.  
Remote Control (secondary side)  
The CTRL-pin can be configured as remote control via the  
PMBus interface. In the default configuration the CTRL-  
pin is disabled and floating. The output can be configured  
to internal pull-up to 3.3 V using the MFR_MULTI_PIN_  
CONFIG (0xF9) PMBus command. The CTRL-pin can be left  
open when not used. The logic options for the secondary  
remote control can be positive or negative logic. The logic  
option for the secondary remote control is configured  
via ON_OFF_CONFIG (0x02) command using the PMBus  
interface, see also MFR_MULTI_PIN_CONFIG section.  
Input Voltage  
The NQB consists of two different product families  
designed for two different input voltage ranges, 36 to 75  
Vdc and 40 to 60 Vdc, see ordering information.  
The input voltage range 36 to 75 Vdc meets the  
requirements of the European Telecom Standard ETS 300  
132-2 for normal input voltage range in –48 and –60 Vdc  
systems, -40.5 to -57.0 V and –50.0 to -72 V respectively.  
At input voltages exceeding 75 V, the power loss will  
be higher than at normal input voltage and TP1 must be  
limited to absolute max +125°C. The absolute maximum  
continuous input voltage is 80 Vdc.  
Input and Output Impedance  
The impedance of both the input source and the load will  
interact with the impedance of the product. It is important  
that the input source has low characteristic impedance.  
Minimum recommended external input capacitance is 100  
µF. The performance in some applications can be enhanced  
by addition of external capacitance as described under  
External Decoupling Capacitors.  
The input voltage range 40 to 60 Vdc meets the  
requirements for normal input voltage range in -48 V  
systems, -40.5 to -57.0 V. At input voltages exceeding  
60 V, the power loss will be higher than at normal input  
voltage and TP1 must be limited to absolute max +125°C.  
The absolute maximum continuous input voltage is 65 Vdc.  
External Decoupling Capacitors  
When powering loads with significant dynamic current  
requirements, the voltage regulation at the point of load  
can be improved by addition of decoupling capacitors at  
the load. The most effective technique is to locate low ESR  
ceramic and electrolytic capacitors as close to the load  
as possible, using several parallel capacitors to lower the  
effective ESR. The ceramic capacitors will handle high-  
frequency dynamic load changes while the electrolytic  
capacitors are used to handle low frequency dynamic load  
changes. Ceramic capacitors will also reduce any high  
frequency noise at the load. It is equally important to  
use low resistance and low inductance PWB layouts and  
cabling. External decoupling capacitors will become part  
of the product’s control loop. The control loop is optimized  
for a wide range of external capacitance and the maximum  
recommended value that could be used without any  
additional analysis is found in the electrical specification.  
The ESR of the capacitors is a very important parameter.  
Stable operation is guaranteed with a verified ESR value of  
Turn-off Input Voltage  
The product monitors the input voltage and will turn  
on and turn off at predetermined levels. The minimum  
hysteresis between turn on and turn off input voltage is  
2 V. The turn on and turn off levels of the product can be  
reconfigured using the PMBus interface  
Remote Control (RC)  
The products are fitted with a configurable remote control  
function. The primary remote control is referenced to the  
primary negative input connection (-In). The RC function  
allows the converter to be turned on/off by an external  
device like a semiconductor or mechanical switch. The RC  
pin has an internal pull up resistor. The remote control  
functions can also be configured using the PMBus.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 22 of 36  
>10 mΩ across the output connections.  
For further information please contact your local CUI Power  
Modules representative.  
Margin Up/Down Controls  
These controls allow the output voltage to be momentarily  
adjusted, either up or down, by a nominal 10%. This  
provides a convenient method for dynamically testing  
the operation of the load circuit over its supply margin or  
range. It can also be used to verify the function of supply  
voltage supervisors.  
Parallel Operation (Droop Load Share, DLS)  
The NQB, DLS products are variants that can be connected  
in parallel. The products have a pre-configured voltage  
droop: The stated output voltage set point is at no load.  
The output voltage will decrease when the load current is  
increased. The voltage will droop 0.6 V while load reaches  
max load. This feature allows the products to be connected  
in parallel and share the current with 10% accuracy. Up  
to 90% of max output current can be used from each  
product.  
The margin up and down levels of the product can be re-  
configured using the PMBus interface.  
Soft-start Power Up  
The default rise time of the ramp up is 10 ms. When  
starting by applying input voltage the control circuit boot-  
up time adds an additional 15 ms delay. The soft-start  
power up of the product can be reconfigured using the  
PMBus interface.  
The DLS variants have a pre-configured ramp up time of  
25 ms.  
When running DLS-products in parallel command (0xF9)  
must be set according to MFR_MULTI_PIN_CONFIG. To  
prevent unnecessary current stress, changes of the output  
voltage must be done with the output disabled. This must  
be considered for all commands that affect the output  
voltage.  
Remote Sense  
The product has remote sense that can be used to  
compensate for voltage drops between the output and the  
point of load. The sense traces should be located close  
to the PWB ground layer to reduce noise susceptibility.  
The remote sense circuitry will compensate for up to  
10% voltage drop between output pins and the point of  
load. If the remote sense is not needed +Sense should  
be connected to +Out and -Sense should be connected to  
-Out. To be able to use remote sense the converter must  
be equipped with a Communication interface.  
Voltage regulation DLS products  
12.8  
Module 1  
Module 2  
12.6  
Module 1+2  
12.4  
12.2  
12.0  
11.8  
11.6  
Temperature Protection (OTP, UTP)  
The products are protected from thermal overload by an  
internal temperature shutdown protection. When TP1 as  
defined in thermal consideration section is exceeded the  
product will shut down. The product will make continuous  
attempts to start up (non-latching mode) and resume  
normal operation automatically when the temperature  
has dropped below the temperature threshold set in the  
command OT_WARN_LIMIT (0x51); the hysteresis is  
defined in general electrical specification. The OTP and  
hysteresis of the product can be re-configured using  
the PMBus interface. The product has also an under  
temperature protection. The OTP and UTP fault limit and  
fault response can be configured via the PMBus. Note:  
using the fault response “continue without interruption”  
may cause permanent damage to the product  
0
10  
20  
30  
40  
50  
60  
70  
Output Current [A]  
Feed Forward Capability  
The NQB products have a feed forward function  
implemented that can handle sudden input voltage  
changes. The output voltage will be regulated during an  
input transient and will typically stay within 10% when an  
input transient is applied.  
PMBus configuration and support  
The product provides a PMBus digital interface that enables  
the user to configure many aspects of the device operation  
as well as monitor the input and output parameters.  
Please contact your local CUI Power Modules  
representative for appropriate SW tools to down-load new  
configurations.  
Over Voltage Protection (OVP)  
The product includes over voltage limiting circuitry for  
protection of the load. The default OVP limit is 30% above  
the nominal output voltage. If the output voltage exceeds  
the OVP limit, the product can respond in different ways.  
The default response from an over voltage fault is to  
immediately shut down. The device will continuously check  
for the presence of the fault condition, and when the fault  
condition no longer exists the device will be re-enabled.  
The OVP fault level and fault response can be re-  
configured using the PMBus interface.  
Output Voltage Adjust using PMBus  
The output voltage of the product can be reconfigured  
using the PMBus interface.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 23 of 36  
Over Current Protection (OCP)  
Switching frequency adjust using PMBus  
The product includes current limiting circuitry for  
protection at continuous overload. The default setting for  
the product is hic-up mode if the maximum output current  
is exceeded and the output voltage is below 0.3×Vout, set  
in command IOUT_OC_LV_FAULT_LIMIT (0x48). Above  
the trip voltage value in command 0x48 the product will  
continue operate while maintaining the output current at  
the value set by IOUT_OC_FAULT_LIMIT (0x46). The load  
distribution should be designed for the maximum output  
short circuit current specified.  
The switching frequency is set to 140 kHz as default but  
this can be reconfigured via the PMBus interface. The  
product is optimized at this frequency but can run at  
lower and higher frequency, (125-150 kHz). The electrical  
performance can be affected if the switching frequency is  
changed.  
MFR_MULTI_PIN_CONFIG  
The MFR_MULTI_PIN_CONFIG (0xF9) command enables  
or disables different functions inside the product. This  
command can be configured according to the table for  
different functions.  
Droop Load Share variants (DLS) will enter hic-up mode,  
with a trip voltage, 0.04×Vout, set in command IOUT_  
OC_LV_FAULT_LIMIT (0x48). Above the trip voltage in  
command (0x48) the product will continue operate while  
maintaining the output current at the value set by IOUT_  
OC_FAULT_LIMIT (0x46).  
Bit 7:6  
00 = Stand alone  
01 = Slave (N/A)  
10 = DLS  
1
1
1
1
1
1
0
0
0
0
0
0
11 = Master (N/A)  
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
1
0
1
The over current protection of the product can be  
reconfigured using the PMBus interface.  
Bit 5  
Power Good High Z  
when active  
Bit 4  
Tracking enable  
(N/A)  
0
0
0
0
0
0
0
0
0
0
0
0
Input Over/Under voltage protection  
Bit 3  
The input of the product can be protected from high input  
voltage and low input voltage. The over/under-voltage  
fault level and fault response can be configured via the  
PMBus interface.  
External reference  
(N/A)  
0
0
0
0
0
0
0
0
0
0
0
0
Bit 2  
Power Good  
Enable  
Bit 1  
Reserved  
Bit 0  
0
1
0
1
1
1
1
1
1
1
1
1
0
0
0
0
1
0
1
0
1
0
1
0
Pre-bias Start-up Capability  
Secondary Remote  
Control Pull  
up/down resistor  
enable 1)  
0
1
0
1
0
1
0
1
0
1
0
1
The product has a Pre-bias start up functionality and will  
not sink current during start up if a Pre-bias source is  
present at the output terminals. If the Pre-bias voltage  
is lower than the target value set in VOUT_COMMAND  
(0x21), the product will ramp up to the target value. If  
the Pre-bias voltage is higher than the target value set in  
VOUT_COMMAND (0x21), the product will ramp down to  
the target value and in this case sink current for a limited  
of time set in the command TOFF_MAX_WARN_LIMIT  
(0x66).  
1) When not used  
with PMBus, the  
CTRL input can be  
internally pulled up  
or down depending  
on if it is active high  
or low. When active  
low it will be pulled  
up and vice versa  
Power Good  
The product provides Power Good (PG) flag in the Status  
Word register that indicates the output voltage is within a  
specified tolerance of its target level and no fault condition  
exists. If specified in section Connections, the product  
also provides a PG signal output. The Power Good signal  
is by default configured as active low, Push-pull and can  
be re-configured via the PMBus interface. The Power Good  
output can be configured as Push-pull or “High Z when  
active” to permit AND’ing of parallel devices. It is not  
recommended to use Push-pull when paralleling PG-pins,  
see MFR_MULTI_PIN_CONFIG.  
The MFR_MULTI_PIN_CONFIG can be reconfigured using  
the PMBus interface. Default configuration is set to Power  
Good Push-Pull (0x04) for stand alone variants and DLS  
Power Good Push-Pull (0x86) for Droop Load Share  
variants.  
User customized settings  
This product has two data storage set: Default data (CUI  
factory) and User data. The User data set’s priority is  
higher than the Default data. The User data area is empty  
while shipped to customer. After boot-up, if the controller  
found no data stored in User data area, it will load Default  
data instead.  
Customer can change the RAM data and store the changes  
into flash memory by PMBUS Store_User_All, next power  
cycle will load the User data into RAM for execute.  
Store_Default_All is write protected to ensure the factory  
settings is always available for recovery.  
Synchronization, Tracking and External reference  
This product does not support synchronization, tracking or  
external reference.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 24 of 36  
Output Voltage Regulation  
are found in the output section for each model. The  
product is tested in a sealed box test set up with ambient  
temperatures 85, 55 and 25°C.  
The NQB products are designed to be fully regulated  
within the plotted area. Operating outside this area is not  
recommended.  
13.4  
13.2  
13.0  
12.8  
12.6  
12.4  
12.2  
12.0  
13.4  
13.2  
13.0  
12.8  
12.6  
12.4  
12.2  
12.0  
35 45 55 65 75  
Vin [V]  
35 40 45 50 55 60 65  
Vin [V]  
Vin range: 36-75Vdc  
Vin range:40-60Vdc  
Thermal Consideration  
General  
The product is designed to operate in different thermal  
environments and sufficient cooling must be provided  
to ensure reliable operation. For products mounted on  
a PWB without a heat sink attached, cooling is achieved  
mainly by conduction, from the pins to the host board,  
and convection, which is dependant on the airflow across  
the product. Increased airflow enhances the cooling of  
the product. The Output Current Derating graph found in  
the output section for each model provides the available  
output current vs. ambient air temperature and air velocity  
at VI =53 V.  
Definition of product operating temperature  
The product operating temperature is used to monitor the  
temperature of the product, and proper thermal conditions  
can be verified by measuring the temperature at positions  
P1, P2, P3 and P4. The temperature at these positions (TP1,  
TP2, TP3, TP4) should not exceed the maximum temperatures  
in the table below. The number of measurement points  
may vary with different thermal design and topology.  
Temperatures above maximum TP1, measured at the  
reference point P1 (TP3 / P3 for base plate versions) are not  
allowed and may cause permanent damage.  
The product is tested on a 254 x 254 mm, 35 µm (1 oz),  
16-layer test board mounted vertically in a wind tunnel  
with a cross-section of 608 x 203 mm.  
Position  
Description  
PWB (reference point, open  
frame)  
Max temperature  
TP1=125º C  
P1  
P2  
P3  
P4  
Opto-coupler  
TP2=105º C  
PWB (reference point for  
base-plate version)  
TP3=125º C  
Primary MOSFET  
TP4=125º C  
For products with base plate used in a sealed box/cold  
wall application, cooling is achieved mainly by conduction  
through the cold wall. The Output Current Derating graphs  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 25 of 36  
Connections (Top view)  
Top view  
Pin  
1
Designation  
+In  
Function  
Positive Input  
2
3
4
RC  
Case  
-In  
Remote Control  
Case to GND (optional)  
Negative Input  
5
6
7
8
-Out  
S+  
S-  
SA0  
Negative Output  
Positive Remote Sense  
Negative Remote Sense  
Address pin 0  
Bottom view  
9
SA1  
Address pin 1  
(Best air flow direction is from positive to negative pins.)  
10  
11  
12  
13  
14  
15  
16  
SCL  
SDA  
PG  
DGND  
SALERT  
CTRL  
+Out  
PMBus Clock  
PMBus Data  
Ambient Temperature Calculation  
For products with base plate the maximum allowed  
ambient temperature can be calculated by using the  
thermal resistance.  
Power Good output  
PMBus ground  
PMBus alert signal  
PMBus remote control  
Positive Output  
1. The power loss is calculated by using the formula  
((1/η) - 1) × output power = power losses (Pd).  
η = efficiency of product. E.g. 95 % = 0.95  
2. Find the thermal resistance (Rth) in the Thermal  
Resistance graph found in the Output section for  
each model. Note that the thermal resistance can be  
significantly reduced if a heat sink is mounted on the top  
of the base plate.  
Calculate the temperature increase (ΔT).  
ΔT = Rth x Pd  
3. Max allowed ambient temperature is:  
Max TP1 - ΔT.  
E.g. NQB-468 at 2m/s:  
1. ((1/0.95) - 1) × 468 W = 24.6 W  
2. 19.5 W × 2.8°C/W = 69.0°C}  
3. 125 °C - 69.0°C = max ambient temperature is 56°C  
The actual temperature will be dependent on several  
factors such as the PWB size, number of layers and  
direction of airflow.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 26 of 36  
PMBus Interface  
This product provides a PMBus digital interface that  
enables the user to configure many aspects of the device  
operation as well as to monitor the input and output  
voltages, output current and device temperature. The  
product can be used with any standard two-wire I2C or  
SMBus host device. In addition, the product is compatible  
with PMBus version 1.2 and includes an SALERT line to  
help mitigate bandwidth limitations related to continuous  
fault monitoring. The product supports 100 kHz and 400  
kHz bus clock frequency only. The PMBus signals, SCL,  
SDA and SALERT require passive pull-up resistors as  
stated in the SMBus Specification. Pull-up resistors are  
required to guarantee the rise time as follows:  
Schematic of connection of address resistors.  
SA0/SA1 Index RSA0/RSA1 [kΩ]  
0
1
2
3
4
5
6
7
10  
22  
33  
47  
68  
100  
150  
220  
τ = RPCp 1us  
Eq. 7  
where Rp is the pull-up resistor value and Cp is the bus  
load. The maximum allowed bus load is 400 pF. The pull-  
up resistor should be tied to an external supply between  
2.7 to 5.5 V, which should be present prior to or during  
power-up. If the proper power supply is not available,  
voltage dividers may be applied. Note that in this case, the  
resistance in the equation above corresponds to parallel  
connection of the resistors forming the voltage divider.  
It is recommended to always use PEC (Packet Error Check)  
when communicating via PMBus. For these products it is  
a requirement to use PEC when using Send Byte to the  
device, for example command “RESTORE_DEFAULT_ALL.  
The SA0 and SA1 pins can be configured with a resistor to  
GND according to the following equation.  
PMBus Address = 8 x (SA0value) + (SA1 value)  
If the calculated PMBus address is 0, 11 or 12, PMBus  
address 127 is assigned instead. From a system point of  
view, the user shall also be aware of further limitations of  
the addresses as stated in the PMBus Specification. It is  
not recommended to keep the SA0 and SA1 pins left open.  
Monitoring via PMBus  
A system controller (host device) can monitor a wide  
variety of parameters through the PMBus interface. The  
controller can monitor fault conditions by monitoring the  
SALERT pin, which will be asserted when any number  
of pre-configured fault or warning conditions occur. The  
system controller can also continuously monitor any  
number of power conversion parameters including but not  
limited to the following:  
I2C/SMBus - Timing  
Input voltage  
Output voltage  
Output current  
Internal junction temperature  
Switching frequency (Monitors the set value not  
actual frequency)  
Duty cycle  
Setup and hold times timing diagram  
Software Tools for Design and Production  
The setup time, tset, is the time data, SDA, must be stable  
before the rising edge of the clock signal, SCL. The hold  
time thold, is the time data, SDA, must be stable after  
the rising edge of the clock signal, SCL. If these times are  
violated incorrect data may be captured or meta-stability  
may occur and the bus communication may fail. When  
configuring the product, all standard SMBus protocols  
must be followed, including clock stretching. Additionally,  
a bus-free time delay between every SMBus transmission  
(between every stop & start condition) must occur. Refer  
to the SMBus specification, for SMBus electrical and timing  
For these products CUI provides software for configuring  
and monitoring via the PMBus interface.  
For more information please contact your local  
CUI sales representative.  
PMBus Addressing  
The following figure and table show recommended resistor  
values with min and max voltage range for hard-wiring  
PMBus addresses (series E12, 1% tolerance resistors  
suggested):  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 27 of 36  
requirements. Note that an additional delay of 5 ms has  
to be inserted in case of storing the RAM content into the  
internal non-volatile memory.  
Designation  
Cmd Prot  
IOUT_OC_FAULT_RESPONSE  
IOUT_OC_LV_FAULT_LIMIT  
IOUT_OC_WARN_LIMIT  
OT_FAULT_LIMIT  
OT_FAULT_RESPONSE  
OT_WARN_LIMIT  
47h  
48h  
4Ah  
4Fh  
50h  
51h  
52h  
53h  
54h  
55h  
56h  
57h  
58h  
59h  
5Ah  
5Eh  
5Fh  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
PMBus Commands  
The products are PMBus compliant. The following table  
lists the implemented PMBus read commands. For  
more detailed information see PMBus Power System  
Management Protocol Specification; Part I – General  
Requirements, Transport and Electrical Interface and  
PMBus Power System Management Protocol; Part II –  
Command Language.  
UT_WARN_LIMIT  
UT_FAULT_LIMIT  
UT_FAULT_RESPONSE  
VIN_OV_FAULT_LIMIT  
VIN_OV_FAULT_RESPONSE  
VIN_OV_WARN_LIMIT  
VIN_UV_WARN_LIMIT  
VIN_UV_FAULT_LIMIT  
VIN_UV_FAULT_RESPONSE  
POWER_GOOD_ON  
POWER_GOOD_OFF  
Time setting Commands  
TON_DELAY  
Designation  
Cmd Prot  
Standard PMBus Commands  
Control Commands  
OPERATION  
01h  
02h  
10h  
No  
No  
No  
ON_OFF_CONFIG  
WRITE_PROTECT  
Output Commands  
VOUT_MODE  
VOUT_COMMAND  
VOUT_TRIM  
VOUT_CAL_OFFSET  
VOUT_MAX  
VOUT_MARGIN_HIGH  
VOUT_MARGIN_LOW  
VOUT_TRANSITION_RATE  
VOUT_SCALE_LOOP  
VOUT_SCALE_MONITOR  
MAX_DUTY  
FREQUENCY_SWITCH  
VIN_ON  
VIN_OFF  
20h  
21h  
22h  
23h  
24h  
25h  
26h  
27h  
29h  
2Ah  
32h  
33h  
35h  
36h  
38h  
39h  
No  
No  
No  
Yes  
No  
No  
No  
No  
Yes  
Yes  
No  
No  
No  
No  
Yes  
Yes  
60h  
61h  
62h  
63h  
64h  
65h  
66h  
No  
No  
No  
No  
No  
No  
No  
TON_RISE  
TON_MAX_FAULT_LIMIT  
TON_MAX_FAULT_RESPONSE  
TOFF_DELAY  
TOFF_FALL  
TOFF_MAX_WARN_LIMIT  
Status Commands (Read Only)  
CLEAR_FAULTS  
STATUS_BYTES  
STATUS_WORD  
03h  
78h  
79h  
7Ah  
7Bh  
No  
No  
No  
No  
No  
STATUS_VOUT  
STATUS_IOUT  
STATUS_INPUT  
STATUS_TEMPERATURE  
STATUS_CML  
7Ch No  
7Dh No  
IOUT_CAL_GAIN  
IOUT_CAL_OFFSET  
Fault Commands  
7Eh  
7Fh  
No  
No  
STATUS_OTHER  
VOUT_OV_FAULT_LIMIT  
VOUT_OV_FAULT_RESPONSE  
VOUT_OV_WARN_LIMIT  
VOUT_UV_WARN_LIMIT  
VOUT_UV_FAULT_LIMIT  
VOUT_UV_FAULT_RESPONSE  
IOUT_OC_FAULT_LIMIT  
40h  
41h  
42h  
43h  
44h  
45h  
46h  
No  
No  
No  
No  
No  
No  
No  
Monitior Commands (Read Only)  
READ_VIN  
88h  
8Bh  
8Ch No  
8Dh No  
8Eh  
94h  
No  
No  
READ_VOUT  
READ_IOUT  
READ_TEMPERATURE_1  
READ_TEMPERATURE_2  
READ_DUTY_CYCLE  
No  
No  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 28 of 36  
Designation  
Cmd Prot  
READ_FREQUENCY  
95h  
No  
Configuration and Control Commands  
86(5 '$7$ ꢀꢀꢁ  
%ꢀK  
1R  
Identification Commands (Read Only)  
PMBUS_REVISION  
MFR_ID  
MFR_MODEL  
MFR_REVISION  
MFR_LOCATION  
MFR_DATE  
98h  
99h  
9Ah  
9Bh  
9Ch Yes  
9Dh Yes  
No  
Yes  
Yes  
Yes  
MFR_SERIAL  
9Eh  
Yes  
Supervisory Commands  
STORE_DEFAULT_ALL  
RESTORE_DEFAULT_ALL  
STORE_USER_ALL  
RESTORE_USER_ALL  
CAPABILITY  
11h  
12h  
15h  
16h  
19h  
Yes  
No  
No  
No  
No  
Product Specific Commands  
MFR_POWER_GOOD_POLARITY  
D0h No  
D3h Yes  
DCh No  
DDh Yes  
DEh Yes  
MFR_VIN_SCALE_MONITOR  
MFR_SELECT_TEMP_SENSOR  
MFR_VIN_OFFSET  
MFR_VOUT_OFFSET_MONITOR  
MFR_TEMP_OFFSET_INT  
MFR_REMOTE_TEMP_CAL  
MFR_REMOTE_CTRL  
E1h  
E2h  
E3h  
No  
No  
No  
MFR_DEAD_BAND_DELAY  
MFR_TEMP_COEFF  
MFR_DEBUG_BUFF  
MFR_SETUP_PASSWORD  
MFR_DISABLE_SECURITY_ONCE  
MFR_DEAD_BAND_IOUT_THRESHOLD  
MFR_SECURITY_BIT_MASK  
MFR_PRIMARY_TURN  
E5h  
E7h  
F0h  
F1h  
F2h  
F3h  
F4h  
F5h  
Yes  
Yes  
No  
No  
No  
Yes  
Yes  
Yes  
MFR_SECONDARY_TURN  
MFR_ILIM_SOFTSTART  
F6h  
F8h  
Yes  
No  
MFR_MULTI_PIN_CONFIG  
MFR_DEAD_BAND_VIN_THRESHOLD  
MFR_DEAD_BAND_VIN_IOUT_HYS  
MFR_RESTART  
F9h  
No  
FAh Yes  
FBh Yes  
FEh No  
Note:  
1. Cmd, is short for Command.  
2. Prot, is short for commands that are protected with security mask.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 29 of 36  
Mechanical Information - Hole Mount, Open Frame Version  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 30 of 36  
Mechanical Information - Hole Mount, Base Plate Version  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 31 of 36  
Mechanical Information - Surface Mount Version  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 32 of 36  
Lead-free (Pb-free) solder processes  
For Pb-free solder processes, a pin temperature (TPIN)  
in excess of the solder melting temperature (TL, 217 to  
221°C for SnAgCu solder alloys) for more than 60 seconds  
and a peak temperature of 245°C on all solder joints is  
recommended to ensure a reliable solder joint.  
Soldering Information - Surface Mounting  
The surface mount product is intended for forced  
convection or vapor phase reflow soldering in SnPb and  
Pb-free processes.  
The reflow profile should be optimised to avoid excessive  
heating of the product. It is recommended to have  
a sufficiently extended preheat time to ensure an  
even temperature across the host PWB and it is also  
recommended to minimize the time in reflow.  
Maximum Product Temperature Requirements  
Top of the product PWB near pin 2 is chosen as reference  
location for the maximum (peak) allowed product  
temperature (TPRODUCT) since this will likely be the warmest  
part of the product during the reflow process.  
A no-clean flux is recommended to avoid entrapment of  
cleaning fluids in cavities inside the product or between  
the product and the host board, since cleaning residues  
may affect long time reliability and isolation voltage.  
SnPb solder processes  
For SnPb solder processes, the product is qualified for MSL  
1 according to IPC/JEDEC standard J STD 020C.  
During reflow TPRODUCT must not exceed 225 °C at any time.  
Pb-free  
General reflow process specifications SnPb eutectic  
Average ramp-up (TPRODUCT  
)
3°C/s max  
183°C  
3°C/s max  
Pb-free solder processes  
Typical solder melting (liquidus)  
temperature  
TL  
221°C  
For Pb-free solder processes, the product is qualified for  
MSL 3 according to IPC/JEDEC standard J-STD-020C.  
Minimum reflow time above TL  
Minimum pin temperature  
Peak product temperature  
60 s  
60 s  
TPIN  
210°C  
235°C  
TPRODUCT  
225°C  
260°C  
During reflow TPRODUCT must not exceed 260 °C at any time.  
Average ramp-down (TPRODUCT  
Maximum time 25°C to peak  
)
6°C/s max  
6 minutes  
6°C/s max  
8 minutes  
Dry Pack Information  
Products intended for Pb-free reflow soldering processes  
are delivered in standard moisture barrier bags according  
to IPC/JEDEC standard J STD 033 (Handling, packing,  
shipping and use of moisture/reflow sensitivity surface  
mount devices).  
Temperature  
TPRODUCT maximum  
TPIN minimum  
Pin  
profile  
TL  
Product  
profile  
Using products in high temperature Pb-free soldering  
processes requires dry pack storage and handling. In  
case the products have been stored in an uncontrolled  
environment and no longer can be considered dry, the  
modules must be baked according to J STD 033.  
Time in  
reflow  
Time in preheat  
/ soak zone  
Time 25°C to peak  
Time  
Thermocoupler Attachment  
Minimum Pin Temperature Recommendations  
Top of PWB near pin 2 for measurement of maximum  
product temperature, TPRODUCT  
Pin number 5 chosen as reference location for the  
minimum pin temperature recommendation since this will  
likely be the coolest solder joint during the reflow process.  
SnPb solder processes  
For SnPb solder processes, a pin temperature (TPIN) in  
excess of the solder melting temperature, (TL, 183°C  
for Sn63Pb37) for more than 60 seconds and a peak  
temperature of 220°C is recommended to ensure a reliable  
solder joint.  
For dry packed products only: depending on the type of  
solder paste and flux system used on the host board, up to  
a recommended maximum temperature of 245°C could be  
used, if the products are kept in a controlled environment  
(dry pack handling and storage) prior to assembly.  
Pin 5 for measurement of minimum pin (solder joint )  
temperature, TPIN  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 33 of 36  
Soldering Information - Hole Mounting  
The hole mounted product is intended for plated through  
hole mounting by wave or manual soldering. The pin  
temperature is specified to maximum to 270°C for  
maximum 10 seconds.  
A maximum preheat rate of 4°C/s and maximum preheat  
temperature of 150°C is suggested. When soldering by  
hand, care should be taken to avoid direct contact between  
the hot soldering iron tip and the pins for more than a few  
seconds in order to prevent overheating.  
A no-clean flux is recommended to avoid entrapment of  
cleaning fluids in cavities inside the product or between  
the product and the host board. The cleaning residues may  
affect long time reliability and isolation voltage.  
Delivery Package Information  
The products are delivered in antistatic injection molded  
trays (Jedec design guide 4.10D standard) and in antistatic  
trays.  
Tray Specifications – SMD  
Material  
Surface resistance  
Antistatic PPE  
105 < Ohm/square < 1012  
The trays can be baked at maximum  
125°C for 48 hours  
Bakability  
Tray thickness  
Box capacity  
Tray weight  
14.50 mm 0.571 [ inch]  
20 products (2 full trays/box)  
125 g empty, 574 g full tray  
JEDEC standard tray for 2x5 = 10 products.  
All dimensions in mm [inch]  
Tolerances: X.x ±0.26 [0.01], X.xx ±0.13 [0.005]  
Note: pick up positions refer to center of pocket.  
See mechanical drawing for exact location on product.  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 34 of 36  
Tray Specifications - TH  
Material  
PE Foam  
Surface  
105 < Ohm/square < 1012  
resistance  
Bakability  
Tray capacity  
Box capacity  
The trays are not bakeable  
20 converters/tray  
20 products (1 full tray/box)  
Product – Open frame  
1100 g full tray, 140g empty tray  
Product – Base plate option  
1480 g full tray, 140 g empty tray  
Weight  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 35 of 36  
Product Qualification Specification  
Characteristics  
External visual inspection  
IPC-A-610  
Temperature range  
Number of cycles  
Dwell/transfer time  
-40 to 100°C  
500  
15 min/0-1 min  
Change of temperature  
(Temperature cycling)  
IEC 60068-2-14 Na  
Temperature TA  
Duration  
Temperature  
Humidity  
Duration  
-45°C  
72 h  
85°C  
85 % RH  
1000 hours  
125°C  
1000 h  
Cold (in operation)  
Damp heat  
IEC 60068-2-1 Ad  
IEC 60068-2-67 Cy  
IEC 60068-2-2 Bd  
Temperature  
Duration  
Dry heat  
Electrostatic discharge  
susceptibility  
IEC 61340-3-1, JESD 22-A114  
IEC 61340-3-2, JESD 22-A115  
Human body model (HBM)  
Machine Model (MM)  
Class 2, 2000 V  
Class 3, 200 V  
Water  
Glycol ether  
Isopropyl alcohol  
55°C  
35°C  
35°C  
Immersion in cleaning solvents  
IEC 60068-2-45 XA, method 2  
Peak acceleration  
Duration  
100 g  
6 ms  
Mechanical shock  
IEC 60068-2-27 Ea  
Level 1 (SnPb-eutectic)  
Level 3 (Pb Free)  
225°C  
260°C  
Moisture reflow sensitivity 1  
J-STD-020C  
Operational life test  
MIL-STD-202G, method 108A  
IEC 60068-2-20 Tb, method 1A  
Duration  
1000 h  
Solder temperature  
Duration  
270°C  
10-13 s  
Resistance to soldering heat 2  
IEC 60068-2-21 Test Ua1  
IEC 60068-2-21 Test Ue1  
Through hole mount products  
Surface mount products  
All leads  
All leads  
Robustness of terminations  
Preconditioning  
150°C dry bake 16 h  
215°C  
Temperature, SnPb Eutectic  
Temperature, Pb-free  
IEC 60068-2-58 test Td 1  
IEC 60068-2-20 test Ta 2  
235°C  
Solderability  
Preconditioning  
Temperature, SnPb Eutectic  
Temperature, Pb-free  
Steam ageing  
235°C  
245°C  
Frequency  
Spectral density  
Duration  
10 to 500 Hz  
Vibration, broad band random  
IEC 60068-2-64 Fh, method 1  
0.07 g2/Hz  
10 min in each direction  
Notes:  
1. Only for products intended for reflow soldering (surface mount products)  
2. Only for products intended for wave soldering (plated through hole products)  
cui.com  
CUI Inc SERIES: NQB-D DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 36 of 36  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
02/20/2013  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
Novum is a trademark of CUI.  
PMBus is a trademark of SMIF, Inc.  
All other trademarks are the property of their respective owners.  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

NQB-100DWA-DANJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWA-DBNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWA-DCNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWA-DDNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWB-DANG-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWB-DANJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWB-DBNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWB-DCNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWB-DDNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWC-DANJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWC-DBNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100DWC-DCNJ-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI