PBO-15C-12-B [CUI]
INTERNAL AC-DC POWER SUPPLY;型号: | PBO-15C-12-B |
厂家: | CUI INC |
描述: | INTERNAL AC-DC POWER SUPPLY |
文件: | 总8页 (文件大小:1041K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
date 12/14/2020
page 1 of 8
SERIES: PBO-15C │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
• wide input range (85~305 VAC or 100 – 430 VDC)
• available in straight-pin and bent-pin configurations
• wide operating temperature range (-40 to +85 C)
• over-voltage, over-current, short-circuit protection
• IEC/EN/UL 62368 certified
• designed to meet IEC/EN/UL 60335 requirements
• safety class II
• ideal for Industrial Control & Smart Home applications
output
voltage
output
current
max
output
power
max
ripple
and noise¹
efficiency²
MODEL
typ
typ
(Vdc)
3.3
(A)
(W)
(mVp-p)
(%)
PBO-15C-3
PBO-15C-5
PBO-15C-9
PBO-15C-12
PBO-15C-15
PBO-15C-24
3.0
2.8
9.9
150
150
150
150
150
150
75.0
77.0
82.0
82.0
84.0
85.0
5.0
14.0
15.0
15.0
15.0
15.0
9.0
1.67
1.25
1.0
12.0
15.0
24.0
0.625
Note:
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, see Application Circuit.
2. At 230 Vac input.
PART NUMBER KEY
PBO-15C - XX - X
Base Number
Output Voltage
Mounting style
Blank = straight pin
B = bent pin
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PBO-15C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 2 of 8
INPUT
parameter
conditions/description
min
typ
max
units
AC input
DC input
85
100
305
430
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac
at 230 Vac
0.4
0.25
A
A
inrush current
at 115 Vac
at 230 Vac
18
35
A
A
no load power consumption
at 230 Vac
0.25
W
OUTPUT
parameter
conditions/description
min
typ
max
units
3.3 Vdc output models
5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
20,000
15,000
5,000
4,000
2,000
1,000
μF
μF
μF
μF
μF
μF
capacitive load
3.3 Vdc output
other outputs
±3
±2
%
%
initial set point accuracy
line regulation
at full load
±0.5
%
0% ~ 100% load, 3.3 Vdc output
0% ~ 100% load, 5 Vdc output
0% ~ 100% load, other outputs
±2
±1.5
±1
%
%
%
load regulation
hold-up time
at 115 Vac
at 230 Vac
10
40
ms
ms
switching frequency
65
kHz
temperature coefficient
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
units
output voltage clamp
3.3 & 5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
9.0
Vdc
Vdc
Vdc
Vdc
Vdc
12.0
16.0
20.0
30.0
over voltage protection
over current protection
short circuit protection
auto recovery
110
%
continuous, auto recovery
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
isolation voltage
input to output for 1 minute, leakage current <5mA
3,000
Vac
certified toiiiiiiiiiiiiii62368: IEC, EN, UL
designed to meetii60335: IEC, EN, UL
safety approvals
safety class
EMI/EMC
class II
CISPR32/EN55032 CLASS A (Recommended circuit 1, 4)
CISPR32/EN55032 CLASS B (Recommended circuit 2, 3)
ESD
IEC/EN 61000-4-2 Contact ±6kV perf. criteria B
IEC/EN61000-4-3 10V/m perf. criteria A
radiated immunity
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PBO-15C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 3 of 8
(
)
SAFETY & COMPLIANCE CONTINUED
parameter
conditions/description
min
typ
max
units
IEC/EN61000-4-4 ±2KV (Recommended circuit 1, 2) perf. criteria B
IEC/EN61000-4-4 ±4KV (Recommended circuit 3, 4) perf. criteria B
EFT/burst
IEC/EN61000-4-5 line to line ±1KV (Recommended circuit 1, 2) perf. criteria B
IEC/EN61000-4-5 line to line±2KV (Recommended circuit 3, 4) perf. criteria B
surge
conducted immunity
IEC/EN61000-4-6 10Vr.m.s perf. criteria A
IEC/EN61000-4-11 0%, 70% perf. criteria B
voltage dips and interruptions
MTBF
as per MIL-HDBK-217F at 25 °C
1,000,000
hours
RoHS
yes
ENVIRONMENTAL
parameter
conditions/description
min
-40
-40
typ
max
85
units
°C
operating temperature
storage temperature
storage humidity
105
95
°C
%
SOLDERABILITY
parameter
conditions/description
for 5~10 seconds
min
255
350
typ
260
360
max
265
370
units
°C
wave soldering
manual welding
for 3~5 seconds
°C
DERATING CURVE
MECHANICAL
parameter
dimensions
weight
conditions/description
min
typ
max
units
inch
g
44.50 x 24.00 x 15.00 mm (1.751 x 0.944 x 0.590 inches)
11
cooling
free air convection
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PBO-15C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 4 of 8
MECHANICAL DRAWING
Straight-pin configuration
units: mm [inch]
pin section tolerance: ±0.10 [±0.004]
general tolerance: ±0.50 [±0.020]
Note: The separation between all primary and secondary circuits must be maintained
as follows to maintain the safety requirements:
Creepage: >6.4 mm
Clearance: >4.0 mm
PIN CONNECTIONS
PIN
1
Function
AC (N)
AC (L)
+V (cap)
-V (cap)
-Vo
3
5
7
14
16
+Vo
Bent-pin configuration
units: mm [inch]
pin section tolerance: ±0.10 [±0.004]
general tolerance: ±0.50 [±0.020]
Front View
Right View
Bottom View
Note: The separation between all primary and secondary circuits must be maintained
as follows to maintain the safety requirements:
Creepage: >6.4 mm
Clearance: >4.0 mm
PIN CONNECTIONS
PIN
1
Function
AC (N)
AC (L)
+V (cap)
-V (cap)
-Vo
3
5
7
14
16
+Vo
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PBO-15C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 5 of 8
APPLICATION DESIGN REFERENCE
Note:
All applications must follow this minimum circuit implementation. Additional enviromental and application-specific
variations are listed in the following pages.
PBO-15C Series additional component selection guide
FUSE
C1
C2
L1
C3¹
CY1
TVS
Part no.
C4
(required) (required) (required) (required) (required)
(required)
PBO-15C-3
PBO-15C-5
PBO-15C-9
PBO-15C-12
PBO-15C-15
PBO-15C-24
SMBJ7.0A
SMBJ7.0A
SMBJ12A
470μF/16V
(solid-
state
capacitor)
220μF/16V
2.2μH
(Max
22mΩ)
1A/300V 33μF/450V
0.1μF/50V 2.2nF/400Vac
SMBJ20A
SMBJ20A
SMBJ30A
680uF/25V
470uF/35V
220μF/35V
Note:
1. C3 is recommended to be a high frequency electrolytic capacitor with low ESR.
PBO-15C Series Enviromental and EMC selection guide
Recommended
Input voltage
range
Enviroment
temperature
Typical application
Emissions
Class A
Immunity
circuit
1
General purpose
-40°C to 85°C
-25°C to 55°C
-25°C to 55°C
Class III
Class III
Class IV
Smart home,
home appliances,
intelligent building,
intelligent agriculture
2
3
Class B
Class B
85~305Vac
Indoor industrial
Outdoor,
video monitoring,
charging point,
communications,
security
4
-40°C to 85°C
Class A
Class IV
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PBO-15C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 6 of 8
Circuit 1
Table 1
Ambient temperature range
-40°C ~ 85°C
Imunity Class
Class III
Emissions Class
Class A
Component
Recommended value
10D - 10
NTC
LDM
1.2mH (min: 0.4A, max: 4Ω)
0.1μF/310Vac
CX
FUSE (required)
1A/300V, slow blow
Circuit 2
Table 2
Ambient temperature range
-25°C ~ 55°C
Imunity Class
Class III
Emissions Class
Class B
Component
NTC
Recommended value
10D - 10
CY1 (CY2)
LCM
2.2nF/400Vac
10mH (min: 0.4A, max: 600mΩ)
0.33mH (min: 0.4A, max: 1Ω)
0.22μF/310Vac
LDM
CX
FUSE (required)
1A/300V, slow blow
Note:
When designing applications for household use (e.g. Smart Home or Home Appliance application), two Y-Caps (CY1 & CY2 valued at 2.2nF/400Vac each) are required in series
to satisfy 60335 household safety requirements. Non-household applications can use one Y-Cap (CY1 valued at 2.2 nF/400Vac).
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PBO-15C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 7 of 8
APPLICATION DESIGN REFERENCE (CONTINUED)
Circuit 3
Table 3
Ambient temperature range
-25°C ~ 55°C
Imunity Class
Class IV
Emissions Class
Class B
Component
Recommended value
S14K350
MOV
CY1
2.2nF/400Vac
0.22μF/310Vac
CX
LCM
LDM
10mH (min: 0.4A, max: 600mΩ)
0.33mH (min: 0.4A, max: 1Ω)
12Ω/3W
R1
FUSE (required)
2A/300V, slow blow
Circuit 4
Table 4
Imunity Class
Class IV
Ambient temperature range
-40°C ~ 85°C
Emissions Class
Class A
Component
Recommended value
S14K350
MOV
LDM
1.2mH (min: 0.4A, max: 4Ω)
0.1μF/310Vac
CX
R1
12Ω/3W
FUSE (required)
2A/300V, slow blow
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │SERIES: PBO-15C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/14/2020 │ page 8 of 8
REVISION HISTORY
rev.
description
date
1.0
initial release
08/25/2020
12/14/2020
1.01
datasheet update
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明