PDM2-S5-D9-D [CUI]

DC/DC CONVERTER +/-9V 2W;
PDM2-S5-D9-D
型号: PDM2-S5-D9-D
厂家: CUI INC    CUI INC
描述:

DC/DC CONVERTER +/-9V 2W

文件: 总6页 (文件大小:620K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
date 01/18/2021  
page 1 of 6  
SERIES: PDM2-D DESCRIPTION: DC-DC CONVERTER  
FEATURES  
• 2 W isolated output  
• smaller package  
• single/dual unregulated output  
• 1,500 Vdc isolation  
• short circuit protection  
• extended temperature range (-40~105°C)  
• antistatic protection up to 8kV  
• high efficiency at light load  
• efficiency up to 85%  
• EN 62368-1  
input  
voltage  
output  
voltage  
output  
current  
output  
power  
max  
ripple  
efficiency  
MODEL  
and noise2  
typ  
range  
min  
max  
typ  
typ  
(Vdc)  
(Vdc)  
(Vdc)  
5
(mA)  
(mA)  
(W)  
(mVp-p)  
(%)  
PDM2-S3-S5-D  
3.3  
5
2.97~3.63  
4.5~5.5  
40  
40  
400  
400  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
75  
78  
80  
84  
84  
80  
80  
84  
84  
84  
80  
82  
84  
80  
84  
83  
84  
79  
85  
83  
79  
83  
84  
PDM2-S5-S5-D1  
PDM2-S5-S12-D1  
PDM2-S5-S15-D1  
PDM2-S5-D5-D1  
PDM2-S5-D7-D  
5
5
4.5~5.5  
12  
17  
167  
5
4.5~5.5  
15  
13  
133  
5
4.5~5.5  
±5  
±7  
±9  
±12  
±15  
5
±20  
±15  
±11  
±8  
±7  
40  
±200  
±142  
±111  
±83  
±67  
400  
5
4.5~5.5  
PDM2-S5-D9-D1  
PDM2-S5-D12-D1  
PDM2-S5-D15-D1  
PDM2-S12-S5-D1  
PDM2-S12-S12-D1  
PDM2-S12-S24-D1  
PDM2-S12-D5-D1  
PDM2-S12-D9-D1  
PDM2-S12-D12-D1  
PDM2-S12-D15-D1  
PDM2-S24-S5-D1  
PDM2-S24-S9-D1  
PDM2-S24-S12-D1  
PDM2-S24-D5-D1  
PDM2-S24-D12-D1  
PDM2-S24-D15-D1  
5
4.5~5.5  
5
4.5~5.5  
5
4.5~5.5  
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
10.8~13.2  
10.8~13.2  
10.8~13.2  
10.8~13.2  
10.8~13.2  
10.8~13.2  
10.8~13.2  
21.6~26.4  
21.6~26.4  
21.6~26.4  
21.6~26.4  
21.6~26.4  
21.6~26.4  
12  
17  
167  
24  
8
83  
±5  
±9  
±12  
±15  
5
±20  
±11  
±8  
±7  
40  
±200  
±111  
±83  
±67  
400  
9
22  
222  
12  
17  
167  
±5  
±12  
±15  
±20  
±8  
±7  
±200  
±83  
±67  
Notes:  
1. UL approved  
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PDM2-D DESCRIPTION: DC-DC CONVERTER  
date 01/18/2021 page 2 of 6  
PART NUMBER KEY  
PDM2 - SXX - XXX -D  
Base Number  
Packaging Style  
DIP  
Input Voltage  
Output  
Output Voltage  
S = single  
D = dual  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
3.3 Vdc input models  
5 Vdc input models  
12 Vdc input models  
24 Vdc input models  
2.97  
4.5  
10.8  
21.6  
3.3  
5
12  
24  
3.63  
5.5  
13.2  
26.4  
Vdc  
Vdc  
Vdc  
Vdc  
operating input voltage  
for maximum of 1 second  
3.3 Vdc input models  
5 Vdc input models  
12 Vdc input models  
24 Vdc input models  
-0.7  
-0.7  
-0.7  
-0.7  
5
9
18  
30  
Vdc  
Vdc  
Vdc  
Vdc  
surge voltage  
filter  
capacitance filter  
OUTPUT  
parameter  
line regulation  
conditions/description  
min  
typ  
max  
units  
for Vin change of 1%  
±1.2  
%
measured from 10%~100% load  
5 Vdc output models  
9 Vdc output models  
12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
12  
9
8
7
6
%
%
%
%
%
load regulation  
voltage accuracy  
see tolerance envelope curve  
100% load, nominal input voltage  
at 100% load  
switching frequency  
temperature coefficient  
100  
kHz  
±0.03  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
short circuit protection1  
1
s
Notes:  
1. The supply voltage must be discontinued at the end of the short circuit duration  
SAFETY AND COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
Vdc  
input to output for 1 minute, 1 mA max. leakage  
current  
isolation voltage  
isolation resistance  
safety approvals2  
1,500  
1,000  
input to output at 500 Vdc  
MΩ  
certified to 62368-1: EN  
certified to 60950-1: UL  
conducted emissions  
radiated emissions  
CISPR22/EN55022, class B, external circuit required  
CISPR22/EN55022, class B, external circuit required  
IEC/EN61000-4-2, class B, contact ± 8kV for single outputs  
IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs  
ESD  
MTBF  
as per MIL-HDBK-217F at 25°C  
3,500,000  
hours  
RoHS  
2011/65/EU  
Notes:  
2. See specific models listed on page 1  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PDM2-D DESCRIPTION: DC-DC CONVERTER  
date 01/18/2021 page 3 of 6  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-55  
typ  
max  
105  
125  
95  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
see derating curve  
°C  
non-condensing  
%
temperature rise  
Ta=25°C, 100% load  
25  
°C  
SOLDERABILITY  
parameter  
conditions/description  
min  
typ  
max  
300  
260  
units  
°C  
hand soldering  
wave soldering  
1.5 mm from case for 10 seconds  
see wave soldering profile  
°C  
Peak Temp. 260°C Max.  
Wave Soldering Time  
4 Sec. Max.  
250  
200  
150  
100  
10 Sec. Max.  
50  
0
Time (sec.)  
MECHANICAL  
parameter  
dimensions  
conditions/description  
min  
typ  
max  
units  
20.32 x 10.16 x 8.2 (0.800 x 0.400 x 0.323 inch)  
epoxy resin (UL94-V0)  
mm  
case material  
weight  
2.8  
g
MECHANICAL DRAWING  
units: mm[inch]  
tolerance: ±0.25[±0.010]  
pin section tolerance: ±0.10[±0.004]  
PIN CONNECTIONS  
PIN  
1
Single Output  
Dual Output  
GND  
NC  
GND  
NC  
7
8
0V  
0V  
9
+Vo  
NO PIN  
Vin  
+Vo  
-Vo  
Vin  
Front View  
11  
14  
Top View  
PCB Layout  
Bottom View  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PDM2-D DESCRIPTION: DC-DC CONVERTER  
date 01/18/2021 page 4 of 6  
DERATING CURVES  
Tolerance Envelope Curve  
(3.3 Vdc output only)  
Tolerance Envelope Curve  
(all other models)  
10  
5
10  
5
2.5  
1.0  
0
Rated Output Voltage  
0
Rated Output Voltage  
-2.5  
-5  
-10  
-15  
-5  
-10  
-15  
-7.5  
-15  
-7.5  
10 20  
40  
60  
80  
100  
10 20  
40  
60  
80  
100  
Output Current Percentage (%)  
(Nominal Input Voltage)  
Output Current Percentage (%)  
(Nominal Input Voltage)  
Temperature Derating Curve  
120  
100  
80  
60  
40  
20  
Safe operating area  
-40  
0
40  
85  
105  
120  
Ambient Temperature (°C)  
EMC RECOMMENDED CIRCUIT  
Figure 1  
Table 1  
Recommended external circuit components  
LDM  
Vin  
Vin  
+Vo  
Vin  
C1, C2  
CY  
LDM  
(Vdc)  
Cout  
DC/DC  
LOAD  
C1  
C2  
3.3  
5
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
--  
--  
6.8μH  
6.8μH  
6.8μH  
6.8μH  
-Vo  
(0V)  
GND  
GND  
12  
24  
--  
1nF/2KV  
CY  
Note:  
1. See Table 2 for Cout values  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PDM2-D DESCRIPTION: DC-DC CONVERTER  
date 01/18/2021 page 5 of 6  
APPLICATION NOTES  
1. Output load requirement  
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during  
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.  
2. Overload Protection  
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add  
this is to add a circuit breaker to the circuit.  
3. Recommended circuit  
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low  
ESR (see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too  
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance  
must be less than the maximum capacitive load (see Table 3).  
Figure 2  
Single Output  
Vin  
Dual Output  
Vin  
+Vo  
0V  
+Vo  
0V  
Cout  
Cout  
Cout  
Cin  
Cin  
DC  
DC DC  
DC  
GND  
GND  
Vo  
Table 2  
Table 3  
Vin  
(Vdc)  
Cin  
(µF)  
Single Vo  
(Vdc)  
Cout  
(µF)  
Dual Vo  
(Vdc)  
Cout  
(µF)  
Max. Capacitive Load1  
Single Vout Max. Capacitive Load Dual Vout  
(μF)  
(Vdc)  
(μF)  
220  
220  
220  
220  
220  
(Vdc)  
3.3  
5
4.7  
4.7  
2.2  
1
5
9
10  
4.7  
2.2  
1
±5  
±9  
4.7  
2.2  
1
5
5
100  
100  
100  
100  
100  
9
7
12  
24  
12  
±12  
±15  
12  
15  
24  
9
15/24  
0.47  
12  
15  
Note: It’s not recommended to connect any external capacitors in  
applications with less than 0.5 watt output.  
Note:  
1. For each output.  
Note:  
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.  
2. Max. capacitive load tested at input voltage range and full load.  
3. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PDM2-D DESCRIPTION: DC-DC CONVERTER  
date 01/18/2021 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
08/30/2013  
02/23/2015  
02/01/2016  
01/18/2021  
1.01  
1.02  
1.03  
added UL approval to some models  
updated tolerance envelope curves  
safeties updated in features and safety line  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

PDM2-S5-S12-D

DC/DC CONVERTER 12V 2W
CUI

PDM2-S5-S12-S

CONVERT DC/DC 2W 12V 167MA OUT
CUI

PDM2-S5-S15-D

DC-DC CONVERTER
CUI

PDM2-S5-S15-S

15 Vdc, 0.13 A, 2 W, 4.5~5.5 Vdc Input Range
CUI

PDM2-S5-S24-S

DC-DC CONVERTER
CUI

PDM2-S5-S3-S

DC/DC CONVERTER 3.3V 2W
CUI

PDM2-S5-S5-D

DC/DC CONVERTER 5V 2W
CUI

PDM2-S5-S5-S

5 Vdc, 0.4 A, 2 W, 4.5~5.5 Vdc Input Range
CUI

PDM2-S_14

DC-DC CONVERTER
CUI

PDM205023069

1MHz - 100MHz RF/MICROWAVE SPLITTER AND COMBINER, 0.5dB INSERTION LOSS
CRANE

PDM21096LL10ST

Standard SRAM, 512KX8, 100ns, CMOS, PDSO32
IXYS

PDM21096LL10T

Standard SRAM, 512KX8, 100ns, CMOS, PDSO32
IXYS