SERIES: PDS1-S DESCRIPTION: DC-DC CONVERTER  
FEATURES  
• 1 W isolated output  
• smaller package  
• single unregulated output  
• 1,500 Vdc isolation  
• short circuit protection  
• extended temperature range (-40~105°C)  
• antistatic protection up to 8kV  
• UL 60950-1 approval  
• high efficiency at light load  
• efficiency up to 82%  
input  
voltage  
output  
voltage  
output  
current  
output  
power  
max  
ripple  
efciency  
MODEL  
and noise2  
typ  
range  
min  
max  
typ  
typ  
(Vdc)  
(Vdc)  
(Vdc)  
3.3  
5
(mA)  
(mA)  
303  
200  
303  
200  
111  
84  
(W)  
(mVp-p)  
(%)  
PDS1-S3-S3-S  
PDS1-S3-S5-S1  
3.3  
3.3  
5
2.97~3.63  
2.97~3.63  
4.5~5.5  
30  
20  
30  
20  
12  
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
30  
30  
30  
30  
30  
30  
60  
60  
30  
30  
30  
30  
60  
30  
60  
60  
30  
30  
30  
30  
60  
60  
75  
80  
76  
80  
80  
81  
81  
81  
76  
80  
80  
81  
80  
80  
80  
81  
76  
80  
80  
81  
82  
82  
PDS1-S5-S3-S  
3.3  
5
PDS1-S5-S5-S1  
PDS1-S5-S9-S1  
PDS1-S5-S12-S1  
PDS1-S5-S15-S1  
PDS1-S5-S24-S1  
PDS1-S12-S3-S  
PDS1-S12-S5-S1  
PDS1-S12-S9-S1  
PDS1-S12-S12-S1  
PDS1-S12-S15-S1  
PDS1-S15-S5-S  
PDS1-S15-S12-S  
PDS1-S15-S15-S  
PDS1-S24-S3-S  
PDS1-S24-S5-S1  
PDS1-S24-S9-S1  
PDS1-S24-S12-S1  
PDS1-S24-S15-S1  
PDS1-S24-S24-S1  
5
4.5~5.5  
5
4.5~5.5  
9
5
4.5~5.5  
12  
15  
24  
3.3  
5
5
4.5~5.5  
7
67  
5
4.5~5.5  
4
42  
12  
12  
12  
12  
12  
15  
15  
15  
24  
24  
24  
24  
24  
24  
10.8~13.2  
10.8~13.2  
10.8~13.2  
10.8~13.2  
10.8~13.2  
13.5~16.5  
13.5~16.5  
13.5~16.5  
21.6~26.4  
21.6~26.4  
21.6~26.4  
21.6~26.4  
21.6~26.4  
21.6~26.4  
30  
20  
12  
9
303  
200  
111  
83  
9
12  
15  
5
7
67  
20  
9
200  
83  
12  
15  
3.3  
5
7
67  
30  
20  
12  
9
303  
200  
111  
84  
9
12  
15  
24  
7
67  
4
42  
Notes:  
1. UL approved  
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDS1-S DESCRIPTION: DC-DC CONVERTER  
date 10/28/2014 page 2 of 6  
PART NUMBER KEY  
PDS1 - SXX - SXX -S  
Packaging Style  
SIP  
Base Number  
Input Voltage  
Output Voltage  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
3.3 Vdc input models  
5 Vdc input models  
12 Vdc input models  
15 Vdc input models  
24 Vdc input models  
2.97  
4.5  
10.8  
13.5  
21.6  
3.3  
5
12  
15  
24  
3.63  
5.5  
13.2  
16.5  
26.4  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
operating input voltage  
for maximum of 1 second  
3.3 Vdc input models  
5 Vdc input models  
12 Vdc input models  
15 Vdc input models  
24 Vdc input models  
-0.7  
-0.7  
-0.7  
-0.7  
-0.7  
5
9
18  
21  
30  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
surge voltage  
lter  
capacitance lter  
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
for Vin change of 1%  
3.3 Vdc output models  
all other models  
line regulation  
±1.5  
±1.2  
%
%
measured from 10% load to full load  
3.3 Vdc output models  
5 Vdc output models  
18  
12  
8
7
6
%
%
%
%
%
%
load regulation  
9 Vdc output models  
12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
5
voltage accuracy  
see tolerance envelope curve  
100% load, nominal input voltage  
100% load  
switching frequency  
temperature coefcient  
100  
typ  
typ  
300  
kHz  
±0.03  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
max  
max  
units  
short circuit protection  
automatic recovery  
SAFETY AND COMPLIANCE  
parameter  
conditions/description  
min  
units  
Vdc  
isolation voltage  
isolation resistance  
safety approvals1  
conducted emissions  
radiated emissions  
ESD  
input to output for 1 minute at 1 mA max.  
1,500  
1,000  
input to output at 500 Vdc  
UL 60950-1  
MΩ  
CISPR22/EN55022, class B (external circuit required, see Figure 1)  
CISPR22/EN55022, class B (external circuit required, see Figure 1)  
IEC/EN61000-4-2, class B, contact ±8kV  
MTBF  
as per MIL-HDBK-217F @ 25°C  
2011/65/EU  
3,500,000  
hours  
RoHS  
Note:  
1. See specic models noted on page 1  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDS1-S DESCRIPTION: DC-DC CONVERTER  
date 10/28/2014 page 3 of 6  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-55  
typ  
max  
105  
125  
95  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
see derating curve  
°C  
non-condensing  
%
temperature rise  
at full load, Ta = 25°C  
25  
°C  
SOLDERABILITY  
parameter  
conditions/description  
min  
typ  
max  
300  
260  
units  
°C  
hand soldering  
wave soldering  
1.5 mm from case for 10 seconds  
see wave soldering prole  
°C  
Peak Temp. 260°C Max.  
Wave Soldering Time  
250  
4 Sec. Max.  
200  
150  
100  
10 Sec. Max.  
50  
0
Time (sec.)  
MECHANICAL  
parameter  
dimensions  
conditions/description  
min  
typ  
max  
units  
11.60 x 6.00 x 10.10 (0.457 x 0.236 x 0.398 inch)  
plastic (UL94-V0)  
mm  
case material  
weight  
1.2  
g
MECHANICAL DRAWING  
units: mm[inch]  
tolerance: ±0.25[±0.010]  
pin section tolerance: ±0.10[±0.004]  
PIN CONNECTIONS  
PIN  
1
Function  
GND  
Vin  
2
3
0V  
4
+Vo  
Front View  
Bottom View  
PCB Layout  
Top View  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDS1-S DESCRIPTION: DC-DC CONVERTER  
date 10/28/2014 page 4 of 6  
DERATING CURVES  
Tolerance Envelope Curve  
Temperature Derating Curve  
10  
7.5  
5
100  
80  
2.5  
2.5  
0
Rated Output Voltage  
-2.5  
60  
Safe operating area  
-2.5  
40  
20  
-5  
-7.5  
-7.5  
-10  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
-40  
-20  
0
20  
40  
60  
85  
105 120  
Output Current Percentage (%)  
(Nominal Input Voltage)  
Ambient Temperature (°C)  
EMC RECOMMENDED CIRCUIT  
Figure 1  
Table 1  
LDM  
Recommended external circuit components  
Vin  
Vin  
Vin  
+Vo  
C0  
LDM  
(Vdc)  
3.3  
5
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
6.8μH  
6.8μH  
6.8μH  
6.8μH  
6.8μH  
EUT  
LOAD  
C0  
GND  
GND  
0V  
12  
15  
24  
TEST CONFIGURATION  
Figure 2  
Table 2  
Oscilloscope  
Lin  
External components  
Lin 4.7μH  
220μF, ESR < 1.0Ω  
Cin  
Current  
Probe  
at 100 kHz  
Load  
Cin  
DC  
DC  
Note: Input reected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDS1-S DESCRIPTION: DC-DC CONVERTER  
date 10/28/2014 page 5 of 6  
APPLICATION NOTES  
1. Output load requirement  
To ensure this module can operate efciently and reliably, the minimum output load may not be less than 10% of the full load during  
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.  
2. Overload Protection  
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add  
this is to add a circuit breaker to the circuit.  
3. Recommended circuit  
This series has been tested according to the following recommended testing circuit before leaving the factory. This series should be  
tested under load (see Figure 3 & Table 3). If you want to further decrease the input/output ripple, you can increase the capacitance  
accordingly or choose capacitors with low ESR. However, the capacitance of the output lter capacitor must be appropriate. If the  
capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the  
maximum capacitance must be less than the maximum capacitive load (see Table 4).  
Figure 3  
+Vo  
Vin  
GND  
Cout  
Cin  
DC  
DC  
0V  
Table 3  
Table 4  
Vin  
(Vdc)  
Cin  
(F)  
Vo  
(Vdc)  
Cout  
(F)  
Vout  
(Vdc)  
Max. Capacitive Load  
(μF)  
3.3  
5
4.7  
4.7  
2.2  
1
3.3  
5
10  
3.3  
5
220  
220  
220  
220  
220  
220  
10  
12  
15  
24  
--  
9
4.7  
2.2  
1
9
12  
15  
24  
12  
15  
24  
1
--  
0.47  
Note: It’s not recommended to connect any  
external capacitors in applications with  
less than 0.5 watt output.  
Note:  
1. Operation under minimum load will not damage the converter; however, they may not meet all specications listed.  
2. Max. capacitive load tested at input voltage range and full load.  
3. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure.  
4. All specications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specied.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDS1-S DESCRIPTION: DC-DC CONVERTER  
date 10/28/2014 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
03/19/2013  
07/29/2013  
03/07/2014  
10/28/2014  
1.01  
1.02  
1.03  
added model PDS1-S15-S12-S  
added model PDS1-S12-S3-S, updated spec  
added UL approval to some models  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

PDS1040

10A SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040-13

10A SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040CTL

10A DUAL LOW VF SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040CTL-13

10A DUAL LOW VF SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040CTL-7

Rectifier Diode, Schottky, 1 Phase, 1 Element, 10A, 40V V(RRM), Silicon, GREEN, PLASTIC, POWERDI5, 3 PIN
DIODES

PDS1040CTL_10

10A DUAL LOW VF SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040L

10A LOW VF SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040L-13

10A LOW VF SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040L_10

10A LOW VF SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1040_10

10A SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1045

10A SCHOTTKY BARRIER RECTIFIER
DIODES

PDS1045-13

10A SCHOTTKY BARRIER RECTIFIER
DIODES