PDS1-S_14 [CUI]
DC-DC CONVERTER;型号: | PDS1-S_14 |
厂家: | CUI INC |
描述: | DC-DC CONVERTER DC-DC转换器 |
文件: | 总6页 (文件大小:392K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date
page 1 of 6
10/28/2014
SERIES: PDS1-S │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• 1 W isolated output
• smaller package
• single unregulated output
• 1,500 Vdc isolation
• short circuit protection
• extended temperature range (-40~105°C)
• antistatic protection up to 8kV
• UL 60950-1 approval
• high efficiency at light load
• efficiency up to 82%
input
voltage
output
voltage
output
current
output
power
max
ripple
efficiency
MODEL
and noise2
typ
range
min
max
typ
typ
(Vdc)
(Vdc)
(Vdc)
3.3
5
(mA)
(mA)
303
200
303
200
111
84
(W)
(mVp-p)
(%)
PDS1-S3-S3-S
PDS1-S3-S5-S1
3.3
3.3
5
2.97~3.63
2.97~3.63
4.5~5.5
30
20
30
20
12
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
30
30
30
30
30
30
60
60
30
30
30
30
60
30
60
60
30
30
30
30
60
60
75
80
76
80
80
81
81
81
76
80
80
81
80
80
80
81
76
80
80
81
82
82
PDS1-S5-S3-S
3.3
5
PDS1-S5-S5-S1
PDS1-S5-S9-S1
PDS1-S5-S12-S1
PDS1-S5-S15-S1
PDS1-S5-S24-S1
PDS1-S12-S3-S
PDS1-S12-S5-S1
PDS1-S12-S9-S1
PDS1-S12-S12-S1
PDS1-S12-S15-S1
PDS1-S15-S5-S
PDS1-S15-S12-S
PDS1-S15-S15-S
PDS1-S24-S3-S
PDS1-S24-S5-S1
PDS1-S24-S9-S1
PDS1-S24-S12-S1
PDS1-S24-S15-S1
PDS1-S24-S24-S1
5
4.5~5.5
5
4.5~5.5
9
5
4.5~5.5
12
15
24
3.3
5
5
4.5~5.5
7
67
5
4.5~5.5
4
42
12
12
12
12
12
15
15
15
24
24
24
24
24
24
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
13.5~16.5
13.5~16.5
13.5~16.5
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
30
20
12
9
303
200
111
83
9
12
15
5
7
67
20
9
200
83
12
15
3.3
5
7
67
30
20
12
9
303
200
111
84
9
12
15
24
7
67
4
42
Notes:
1. UL approved
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/28/2014 │ page 2 of 6
PART NUMBER KEY
PDS1 - SXX - SXX -S
Packaging Style
SIP
Base Number
Input Voltage
Output Voltage
INPUT
parameter
conditions/description
min
typ
max
units
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
2.97
4.5
10.8
13.5
21.6
3.3
5
12
15
24
3.63
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
Vdc
operating input voltage
for maximum of 1 second
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
-0.7
-0.7
5
9
18
21
30
Vdc
Vdc
Vdc
Vdc
Vdc
surge voltage
filter
capacitance filter
OUTPUT
parameter
conditions/description
min
typ
max
units
for Vin change of 1%
3.3 Vdc output models
all other models
line regulation
±1.5
±1.2
%
%
measured from 10% load to full load
3.3 Vdc output models
5 Vdc output models
18
12
8
7
6
%
%
%
%
%
%
load regulation
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
5
voltage accuracy
see tolerance envelope curve
100% load, nominal input voltage
100% load
switching frequency
temperature coefficient
100
typ
typ
300
kHz
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
max
max
units
short circuit protection
automatic recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
min
units
Vdc
isolation voltage
isolation resistance
safety approvals1
conducted emissions
radiated emissions
ESD
input to output for 1 minute at 1 mA max.
1,500
1,000
input to output at 500 Vdc
UL 60950-1
MΩ
CISPR22/EN55022, class B (external circuit required, see Figure 1)
CISPR22/EN55022, class B (external circuit required, see Figure 1)
IEC/EN61000-4-2, class B, contact ±8kV
MTBF
as per MIL-HDBK-217F @ 25°C
2011/65/EU
3,500,000
hours
RoHS
Note:
1. See specific models noted on page 1
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/28/2014 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
max
105
125
95
units
°C
operating temperature
storage temperature
storage humidity
see derating curve
°C
non-condensing
%
temperature rise
at full load, Ta = 25°C
25
°C
SOLDERABILITY
parameter
conditions/description
min
typ
max
300
260
units
°C
hand soldering
wave soldering
1.5 mm from case for 10 seconds
see wave soldering profile
°C
Peak Temp. 260°C Max.
Wave Soldering Time
250
4 Sec. Max.
200
150
100
10 Sec. Max.
50
0
Time (sec.)
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
11.60 x 6.00 x 10.10 (0.457 x 0.236 x 0.398 inch)
plastic (UL94-V0)
mm
case material
weight
1.2
g
MECHANICAL DRAWING
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
1
Function
GND
Vin
2
3
0V
4
+Vo
Front View
Bottom View
PCB Layout
Top View
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/28/2014 │ page 4 of 6
DERATING CURVES
Tolerance Envelope Curve
Temperature Derating Curve
10
7.5
5
100
80
2.5
2.5
0
Rated Output Voltage
-2.5
60
Safe operating area
-2.5
40
20
-5
-7.5
-7.5
-10
10
20
30
40
50
60
70
80
90
100
-40
-20
0
20
40
60
85
105 120
Output Current Percentage (%)
(Nominal Input Voltage)
Ambient Temperature (°C)
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
LDM
Recommended external circuit components
Vin
Vin
Vin
+Vo
C0
LDM
(Vdc)
3.3
5
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
6.8μH
6.8μH
6.8μH
6.8μH
6.8μH
EUT
LOAD
C0
GND
GND
0V
12
15
24
TEST CONFIGURATION
Figure 2
Table 2
Oscilloscope
Lin
External components
Lin 4.7μH
220μF, ESR < 1.0Ω
Cin
Current
Probe
at 100 kHz
Load
Cin
DC
DC
Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/28/2014 │ page 5 of 6
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
This series has been tested according to the following recommended testing circuit before leaving the factory. This series should be
tested under load (see Figure 3 & Table 3). If you want to further decrease the input/output ripple, you can increase the capacitance
accordingly or choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be appropriate. If the
capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the
maximum capacitance must be less than the maximum capacitive load (see Table 4).
Figure 3
+Vo
Vin
GND
Cout
Cin
DC
DC
0V
Table 3
Table 4
Vin
(Vdc)
Cin
(ꢀF)
Vo
(Vdc)
Cout
(ꢀF)
Vout
(Vdc)
Max. Capacitive Load
(μF)
3.3
5
4.7
4.7
2.2
1
3.3
5
10
3.3
5
220
220
220
220
220
220
10
12
15
24
--
9
4.7
2.2
1
9
12
15
24
12
15
24
1
--
0.47
Note: It’s not recommended to connect any
external capacitors in applications with
less than 0.5 watt output.
Note:
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure.
4. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/28/2014 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
03/19/2013
07/29/2013
03/07/2014
10/28/2014
1.01
1.02
1.03
added model PDS1-S15-S12-S
added model PDS1-S12-S3-S, updated spec
added UL approval to some models
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
PDS1040CTL-7
Rectifier Diode, Schottky, 1 Phase, 1 Element, 10A, 40V V(RRM), Silicon, GREEN, PLASTIC, POWERDI5, 3 PIN
DIODES
©2020 ICPDF网 联系我们和版权申明