SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• 1 W isolated output
• smaller package
• single/dual unregulated outputs
• 3,000 Vdc isolation
• short circuit protection
• extended temperature range (-40~105°C)
• antistatic protection up to 8kV
• high efficiency at light load
• efficiency up to 82%
• EN 62368-1
input
voltage
output
voltage
output
current
output
power
max
ripple
efficiency
MODEL
and noise2
typ
range
min
max
typ
typ
(Vdc)
(Vdc)
(Vdc)
3.3
5
(mA)
(mA)
303
200
303
200
111
84
(W)
(mVp-p)
(%)
PES1-S3-S3-M
3.3
3.3
5
2.97~3.63
2.97~3.63
4.5~5.5
30
20
30
20
12
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
69
74
72
80
80
80
80
80
80
80
79
81
81
72
80
80
80
80
80
80
81
81
81
80
80
80
80
PES1-S3-S5-M1
PES1-S5-S3-M1
PES1-S5-S5-M1
PES1-S5-S9-M1
PES1-S5-S12-M1
PES1-S5-S15-M1
PES1-S5-S24-M1
PES1-S5-D5-M
3.3
5
5
4.5~5.5
5
4.5~5.5
9
5
4.5~5.5
12
15
24
±5
±9
±12
±15
±24
3.3
5
5
4.5~5.5
7
67
5
4.5~5.5
4
42
5
4.5~5.5
±10
±6
±5
±3
±2
30
20
12
9
±100
±56
±42
±33
±21
303
200
111
84
PES1-S5-D9-M
5
4.5~5.5
PES1-S5-D12-M
PES1-S5-D15-M
PES1-S5-D24-M
PES1-S12-S3-M1
PES1-S12-S5-M1
PES1-S12-S9-M1
PES1-S12-S12-M1
PES1-S12-S15-M1
PES1-S12-D5-M
PES1-S12-D9-M
PES1-S12-D12-M
PES1-S12-D15-M
PES1-S12-D24-M
PES1-S15-S15-M
PES1-S24-S5-M1
PES1-S24-S9-M1
PES1-S24-S15-M1
5
4.5~5.5
5
4.5~5.5
5
4.5~5.5
12
12
12
12
12
12
12
12
12
12
15
24
24
24
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
13.5~16.5
21.6~26.4
21.6~26.4
21.6~26.4
9
12
15
±5
±9
±12
±15
±24
15
5
7
67
±10
±6
±5
±3
±2
7
±100
±56
±42
±33
±21
67
20
12
7
200
111
67
9
15
Notes:
1. UL approved
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/11/2021 │ page 2 of 8
input
voltage
output
voltage
output
current
output
power
max
ripple
efficiency
MODEL
(CONTINUED)
PES1-S24-S24-M1
PES1-S24-D5-M
PES1-S24-D9-M
PES1-S24-D12-M
PES1-S24-D15-M
PES1-S24-D24-M
and noise2
typ
(Vdc)
range
min
(mA)
max
(mA)
typ
(mVp-p)
typ
(%)
(Vdc)
(Vdc)
24
(W)
24
24
24
24
24
24
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
4
42
1
1
1
1
1
1
60
60
60
60
60
60
80
80
80
81
82
76
±5
±10
±6
±5
±3
±2
±100
±56
±42
±33
±21
±9
±12
±15
±24
Notes:
1. UL approved
2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PES1 - SXX - XXX - M - X
Output Voltage
Output
S = single
D = dual
Base Number
Input Voltage
Packaging Style
"blank" = tube
TR = tape & reel
INPUT
parameter
conditions/description
min
typ
max
units
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
2.97
4.5
10.8
13.5
21.6
3.3
5
12
15
24
3.63
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
Vdc
operating input voltage
for maximum of 1 second
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
-0.7
-0.7
5
9
18
21
30
Vdc
Vdc
Vdc
Vdc
Vdc
surge voltage
filter
capacitance filter
OUTPUT
parameter
conditions/description
min
typ
max
units
for Vin change of 1%
3.3 Vdc output models
all other models
line regulation
±1.5
±1.2
%
%
measured from 10% load to full load
3.3 Vdc output models
5 Vdc output models
18
12
9
8
7
%
%
%
%
%
%
load regulation
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
6
voltage accuracy
see tolerance envelope curve
100% load, nominal input voltage
100% load
switching frequency
temperature coefficient
100
kHz
±0.03
%/°C
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/11/2021 │ page 3 of 8
PROTECTIONS
parameter
conditions/description
min
typ
typ
max
units
PES1-S5-S24-M, PES1-S5-D24-M and all 24 V
input models1
all other models: continuous, automatic recovery
short circuit protection
1
s
Note:
1. If maximum protection time is exceeded input power must me cycled to restart device.
SAFETY AND COMPLIANCE
parameter
conditions/description
min
max
units
Vdc
isolation voltage
isolation resistance
input to output for 1 minute at 1 mA max.
input to output at 500 Vdc
3,000
1,000
MΩ
certified to 62368-1: EN
certified to 60950-1: UL
safety approvals2
conducted emissions
radiated emissions
CISPR22/EN55022 class B (external circuit required, see Figure 1)
CISPR22/EN55022 class B (external circuit required, see Figure 1)
IEC/EN61000-4-2, class B, contact ± 8kV for single outputs
IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs
ESD
MTBF
as per MIL-HDBK-217F @ 25°C
3,500,000
hours
RoHS
2011/65/EU
Note:
2. See specific models noted on page 1 & 2.
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
max
105
125
95
units
°C
operating temperature
storage temperature
storage humidity
see derating curve
°C
non-condensing
%
temperature rise
at full load, Ta = 25°C
25
°C
SOLDERABILITY
parameter
conditions/description
min
typ
max
300
245
units
°C
hand soldering
1.5 mm from case for 10 seconds
see reflow soldering profile
reflow soldering
°C
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/11/2021 │ page 4 of 8
MECHANICAL
parameter
conditions/description
min
typ
max
units
single output models: 12.70 x 8.30 x 7.25
dual output models: 15.24 x 8.30 x 7.25
mm
mm
dimensions
case material
weight
epoxy resin (UL94-V0)
single output models
dual output models
1.6
2.0
g
g
MECHANICAL DRAWING
SINGLE OUTPUT MODELS
ꢀꢁꢂꢃꢄrꢄꢂꢅꢄꢆAꢄꢂꢅꢄꢄrꢄꢂꢄꢁꢄC
units: mm[inch]
ꢆꢇꢈꢄꢀAꢉꢇꢊꢉꢉC
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
ꢂ
ꢁ
ꢃ
PIN CONNECTIONS
PIN
1
Function
GND
Vin
$
ꢄ
ꢅ
2
4
0V
ꢉꢇꢈꢉꢀAꢉꢇꢉꢄꢅC
5
+Vo
NC
ꢄꢇꢂꢅꢀAꢉꢇꢃꢉꢉC
8
NC: No Connection
:UVꢀ<OK]
$
ꢇꢂꢉꢉꢀAꢇꢂꢇꢋꢃC
ꢉꢇꢃꢉ
,XUTZꢀ<OK]
8OMNZꢀ<OK]
ꢆꢇꢈꢄꢀAꢉꢇꢊꢉꢉC
ꢁ
ꢂ
ꢅ
ꢃ
ꢄ
ꢃꢇꢉꢉꢀAꢉꢇꢉꢊꢋC
ꢄꢇꢂꢅꢀAꢉꢇꢃꢉꢉC
4UZK ꢀ-XOJꢀꢁꢂꢃꢄꢅꢁꢂꢃꢄSS
:UVꢀ<OK]
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/11/2021 │ page 5 of 8
(
)
MECHANICAL DRAWING CONTINUED
DUAL OUTPUT MODELS
units: mm[inch]
15.24 0.50 [0.600 0.020]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
$
PIN
1
Function
GND
Vin
2
4
0V
5
-Vo
0.60 [0.024]
7
+Vo
NC
2.54 [0.100]
10
10.16 [0.400]
NC: No Connection
Top View
$
0.88 [0.035]
0.10
Front View
Right View
10
1
7
4
5
2
1.00 [0.039]
2.54 [0.100]
10.16 [0.400]
Note : Grid 2.54*2.54mm
Top View
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/11/2021 │ page 6 of 8
DERATING CURVES
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
Recommended external
circuit components
Single Outputs
Vin
(Vdc)
C1
LDM
3.3
5
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
6.8μH
6.8μH
6.8μH
6.8μH
6.8μH
12
15
24
Note:
1. See Table 2 for Cout values.
2. CY: 1nF/3kV for 24 Vdc input dual output models,
Dual Outputs
PES1-S5-D24-M, and PES1-S12-D24-M only
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/11/2021 │ page 7 of 8
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR(see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 3).
Figure 2
Single Outputs
Dual Outputs
Table 2
Table 3
Single Vout Max. Capacitive Load Dual Vout
Vin
(Vdc)
Cin
(µF)
Single Vo
Cout
Dual Vo
Cout
Max. Capacitive Load1
(Vdc)
3.3
5
(µF)
(Vdc)
(µF)
(μF)
(Vdc)
3.3
5
(μF)
220
220
220
220
220
220
(Vdc)
3.3
5
4.7
4.7
--
10
10
--
--
4.7
2.2
1
--
--
±5
5
100
100
100
100
100
--
9
4.7
2.2
1
±9
9
9
12
15
24
2.2
2.2
1
12
15
24
±12
±15
±24
12
15
24
12
15
24
1
0.47
0.47
Note:
1. For each output.
Note:
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure.
4. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 08/11/2021 │ page 8 of 8
REVISION HISTORY
rev.
description
date
1.0
initial release
03/19/2013
04/04/2014
10/21/2014
06/26/2015
01/18/2021
1.01
1.02
1.03
1.04
added models, updated spec
added UL approval to some models
updated tolerance envelope curves
safeties updated in features and safety approvals line
derating curves and circuit figures updated, short circuit protection
1.05
08/11/2021
note updated
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明