SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• 1 W isolated output
• smaller package
• single regulated output
• 1,500 Vdc isolation
• continuous short circuit protection
• extended temperature range (-40~85°C)
• high efficiency at light load
• efficiency up to 75%
input
voltage
output
voltage
output
current
output
power
max
ripple
efficiency
MODEL
and noise1
typ
range
min
max
typ
typ
(Vdc)
(Vdc)
(Vdc)
3.3
5
(mA)
(mA)
243
200
111
84
(W)
(mVp-p)
(%)
PQM1-S5-S3-M
PQM1-S5-S5-M
PQM1-S5-S9-M
PQM1-S5-S12-M
PQM1-S5-S15-M
PQM1-S12-S5-M
PQM1-S12-S9-M
PQM1-S12-S12-M
PQM1-S12-S15-M
PQM1-S24-S5-M
PQM1-S24-S9-M
PQM1-S24-S12-M
PQM1-S24-S15-M
5
4.75~5.25
4.75~5.25
4.75~5.25
4.75~5.25
4.75~5.25
11.4~12.6
11.4~12.6
11.4~12.6
11.4~12.6
22.8~25.2
22.8~25.2
22.8~25.2
22.8~25.2
25
20
12
9
0.8
1
50
50
50
50
50
50
50
50
50
50
50
50
50
58
72
74
73
74
73
74
73
75
73
74
73
74
5
5
9
1
5
12
15
5
1
5
7
67
1
12
12
12
12
24
24
24
24
20
12
9
200
111
84
1
9
1
12
15
5
1
7
67
1
20
12
9
200
111
84
1
9
1
12
15
1
7
67
1
Note:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PQM1 - SXX - SXX - M - X
Base Number
Input Voltage
Output
S = single
Output Voltage
Packaging Style
"blank" = tube
TR = tape & reel
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
5 Vdc input models
12 Vdc input models
24 Vdc input models
4.75
11.4
22.8
5
12
24
5.25
12.6
25.2
Vdc
Vdc
Vdc
operating input voltage
for maximum of 1 second
5 Vdc input models
12 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
9
18
30
Vdc
Vdc
Vdc
surge voltage
filter
capacitance filter
OUTPUT
parameter
line regulation
conditions/description
min
typ
max
units
for Vin change of 1%
±0.25
%
measured from 10% load to full load
3.3 Vdc output models
all other models
load regulation
3
1
%
%
voltage accuracy
at 100% load
±3
300
%
switching frequency
temperature coefficient
at 100% load, nominal input voltage
at 100% load
100
typ
typ
kHz
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
max
max
units
short circuit protection
continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter
isolation voltage
isolation resistance
conducted emissions
radiated emissions
ESD
conditions/description
min
units
Vdc
input to output for 1 minute at 1 mA max.
input to output at 500 Vdc
1,500
1,000
MΩ
CISPR22/EN55022 class B (external circuit required, see Figure 1)
CISPR22/EN55022 class B (external circuit required, see Figure 1)
IEC/EN61000-4-2, class B, contact ± 8kV
MTBF
as per MIL-HDBK-217F @ 25°C
2011/65/EU
3,500,000
hours
RoHS
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
max
85
units
°C
operating temperature
storage temperature
storage humidity
see derating curve
125
95
°C
non-condensing
%
temperature rise
at full load, Ta = 25°C
25
°C
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 3 of 6
SOLDERABILITY
parameter
conditions/description
min
typ
max
300
245
units
°C
hand soldering
1.5 mm from case for 10 seconds
see reflow soldering profile
reflow soldering
°C
250
245
ꢀ
°C
P e a k . Te m p 245 ( M a x.)
217
200
6 0 Se c M ax
°C
ꢀ )
( >2 17
150
100
50
0
Time (sec.)
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
15.24 x 11.20 x 7.25 (0.600 x 0.441 x 0.285 inch)
epoxy resin (UL94-V0)
mm
case material
weight
2.0
g
MECHANICAL DRAWING
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
FUNCTION
GND
Vin
1
2
4/5
0V
7
+Vo
10
NC
NC: No Connection
Top View
Side View
Top View
PCB Layout
Front View
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 4 of 6
DERATING CURVE
Temperature Derating Curve
100
80
60
Safe operating area
40
20
-40
-20
0
20
40
60 71
85
100
Ambient Temperature (°C)
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
Recommended external circuit components
Vout
(Vdc)
LDM
V in
V in
+Vo
0V
C1
C2
LDM
3.3
5
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
10μF
10μF
4.7μF
2.2μF
1μF
6.8μH
6.8μH
6.8μH
6.8μH
6.8μH
DC DC
LOAD
C1
C2
9
12
15
GND
GND
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 5 of 6
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR (see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 3).
Figure 2
+Vo
V in
Cout
Cin
DC
DC
GND
0V
Table 2
Vo
Table 3
Vin
(Vdc)
Cin
Cout
(ꢀF)
Vout
(Vdc)
Max. Capacitive Load
(ꢀF)
4.7
2.2
1
(Vdc)
3.3
5
(μF)
5
10
10
4.7
2.2
1
3.3
5
220
220
220
220
220
12
24
--
9
9
--
12
15
12
15
--
--
Note: It’s not recommended to connect any external capacitors in
applications with less than 0.5 watt output.
Note:
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQM1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/08/2014 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
04/08/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明