SERIES: PQM1-M DESCRIPTION: DC-DC CONVERTER  
FEATURES  
• 1 W isolated output  
• smaller package  
• single regulated output  
• 1,500 Vdc isolation  
• continuous short circuit protection  
• extended temperature range (-40~85°C)  
• high efficiency at light load  
• efficiency up to 75%  
input  
voltage  
output  
voltage  
output  
current  
output  
power  
max  
ripple  
efciency  
MODEL  
and noise1  
typ  
range  
min  
max  
typ  
typ  
(Vdc)  
(Vdc)  
(Vdc)  
3.3  
5
(mA)  
(mA)  
243  
200  
111  
84  
(W)  
(mVp-p)  
(%)  
PQM1-S5-S3-M  
PQM1-S5-S5-M  
PQM1-S5-S9-M  
PQM1-S5-S12-M  
PQM1-S5-S15-M  
PQM1-S12-S5-M  
PQM1-S12-S9-M  
PQM1-S12-S12-M  
PQM1-S12-S15-M  
PQM1-S24-S5-M  
PQM1-S24-S9-M  
PQM1-S24-S12-M  
PQM1-S24-S15-M  
5
4.75~5.25  
4.75~5.25  
4.75~5.25  
4.75~5.25  
4.75~5.25  
11.4~12.6  
11.4~12.6  
11.4~12.6  
11.4~12.6  
22.8~25.2  
22.8~25.2  
22.8~25.2  
22.8~25.2  
25  
20  
12  
9
0.8  
1
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
50  
58  
72  
74  
73  
74  
73  
74  
73  
75  
73  
74  
73  
74  
5
5
9
1
5
12  
15  
5
1
5
7
67  
1
12  
12  
12  
12  
24  
24  
24  
24  
20  
12  
9
200  
111  
84  
1
9
1
12  
15  
5
1
7
67  
1
20  
12  
9
200  
111  
84  
1
9
1
12  
15  
1
7
67  
1
Note:  
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.  
PART NUMBER KEY  
PQM1 - SXX - SXX - M - X  
Base Number  
Input Voltage  
Output  
S = single  
Output Voltage  
Packaging Style  
"blank" = tube  
TR = tape & reel  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PQM1-M DESCRIPTION: DC-DC CONVERTER  
date 04/08/2014 page 2 of 6  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
5 Vdc input models  
12 Vdc input models  
24 Vdc input models  
4.75  
11.4  
22.8  
5
12  
24  
5.25  
12.6  
25.2  
Vdc  
Vdc  
Vdc  
operating input voltage  
for maximum of 1 second  
5 Vdc input models  
12 Vdc input models  
24 Vdc input models  
-0.7  
-0.7  
-0.7  
9
18  
30  
Vdc  
Vdc  
Vdc  
surge voltage  
lter  
capacitance lter  
OUTPUT  
parameter  
line regulation  
conditions/description  
min  
typ  
max  
units  
for Vin change of 1%  
±0.25  
%
measured from 10% load to full load  
3.3 Vdc output models  
all other models  
load regulation  
3
1
%
%
voltage accuracy  
at 100% load  
±3  
300  
%
switching frequency  
temperature coefcient  
at 100% load, nominal input voltage  
at 100% load  
100  
typ  
typ  
kHz  
±0.03  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
max  
max  
units  
short circuit protection  
continuous, automatic recovery  
SAFETY AND COMPLIANCE  
parameter  
isolation voltage  
isolation resistance  
conducted emissions  
radiated emissions  
ESD  
conditions/description  
min  
units  
Vdc  
input to output for 1 minute at 1 mA max.  
input to output at 500 Vdc  
1,500  
1,000  
MΩ  
CISPR22/EN55022 class B (external circuit required, see Figure 1)  
CISPR22/EN55022 class B (external circuit required, see Figure 1)  
IEC/EN61000-4-2, class B, contact ± 8kV  
MTBF  
as per MIL-HDBK-217F @ 25°C  
2011/65/EU  
3,500,000  
hours  
RoHS  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-55  
typ  
max  
85  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
see derating curve  
125  
95  
°C  
non-condensing  
%
temperature rise  
at full load, Ta = 25°C  
25  
°C  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PQM1-M DESCRIPTION: DC-DC CONVERTER  
date 04/08/2014 page 3 of 6  
SOLDERABILITY  
parameter  
conditions/description  
min  
typ  
max  
300  
245  
units  
°C  
hand soldering  
1.5 mm from case for 10 seconds  
see reow soldering prole  
reow soldering  
°C  
250  
245  
°C  
P e a k . Te m p 245 ( M a x.)  
217  
200  
6 0 Se c M ax  
°C  
)  
( >2 17  
150  
100  
50  
0
Time (sec.)  
MECHANICAL  
parameter  
dimensions  
conditions/description  
min  
typ  
max  
units  
15.24 x 11.20 x 7.25 (0.600 x 0.441 x 0.285 inch)  
epoxy resin (UL94-V0)  
mm  
case material  
weight  
2.0  
g
MECHANICAL DRAWING  
units: mm[inch]  
tolerance: ±0.25[±0.010]  
pin section tolerance: ±0.10[±0.004]  
PIN CONNECTIONS  
PIN  
FUNCTION  
GND  
Vin  
1
2
4/5  
0V  
7
+Vo  
10  
NC  
NC: No Connection  
Top View  
Side View  
Top View  
PCB Layout  
Front View  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PQM1-M DESCRIPTION: DC-DC CONVERTER  
date 04/08/2014 page 4 of 6  
DERATING CURVE  
Temperature Derating Curve  
100  
80  
60  
Safe operating area  
40  
20  
-40  
-20  
0
20  
40  
60 71  
85  
100  
Ambient Temperature (°C)  
EMC RECOMMENDED CIRCUIT  
Figure 1  
Table 1  
Recommended external circuit components  
Vout  
(Vdc)  
LDM  
V in  
V in  
+Vo  
0V  
C1  
C2  
LDM  
3.3  
5
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
4.7μF/50V  
10μF  
10μF  
4.7μF  
2.2μF  
1μF  
6.8μH  
6.8μH  
6.8μH  
6.8μH  
6.8μH  
DC DC  
LOAD  
C1  
C2  
9
12  
15  
GND  
GND  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PQM1-M DESCRIPTION: DC-DC CONVERTER  
date 04/08/2014 page 5 of 6  
APPLICATION NOTES  
1. Output load requirement  
To ensure this module can operate efciently and reliably, the minimum output load may not be less than 10% of the full load during  
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.  
2. Overload Protection  
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add  
this is to add a circuit breaker to the circuit.  
3. Recommended circuit  
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low  
ESR (see Figure 2 & Table 2). However, the capacitance of the output lter capacitor must be appropriate. If the capacitance is too  
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance  
must be less than the maximum capacitive load (see Table 3).  
Figure 2  
+Vo  
V in  
Cout  
Cin  
DC  
DC  
GND  
0V  
Table 2  
Vo  
Table 3  
Vin  
(Vdc)  
Cin  
Cout  
(F)  
Vout  
(Vdc)  
Max. Capacitive Load  
(F)  
4.7  
2.2  
1
(Vdc)  
3.3  
5
(μF)  
5
10  
10  
4.7  
2.2  
1
3.3  
5
220  
220  
220  
220  
220  
12  
24  
--  
9
9
--  
12  
15  
12  
15  
--  
--  
Note: It’s not recommended to connect any external capacitors in  
applications with less than 0.5 watt output.  
Note:  
1. Operation under minimum load will not damage the converter; however, they may not meet all specications listed.  
2. Max. capacitive load tested at input voltage range and full load.  
3. All specications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specied.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PQM1-M DESCRIPTION: DC-DC CONVERTER  
date 04/08/2014 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
04/08/2014  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

PQM3-D12-S12-M

12 Vdc, 0.25 A, 3 W, 9~18 Vdc Input Range
CUI

PQM3-D12-S12-M-TR

CONVERT DC/DC 3W 12V 250MA OUT
CUI

PQM3-D12-S15-M

DC-DC CONVERTER
CUI

PQM3-D12-S15-M-TR

CONVERT DC/DC 3W 15V 200MA OUT
CUI

PQM3-D12-S5-M

DC-DC CONVERTER
CUI

PQM3-D12-S5-M-TR

DC DC CONVERTER 5V 3W
CUI

PQM3-D24-S12-M

DC-DC CONVERTER
CUI

PQM3-D24-S12-M-TR

CONVERT DC/DC 3W 12V 250MA OUT
CUI

PQM3-D24-S15-M

DC-DC CONVERTER
CUI

PQM3-D24-S15-M-TR

CONVERT DC/DC 3W 15V 200MA OUT
CUI

PQM3-D24-S5-M

DC-DC CONVERTER
CUI

PQM3-D24-S5-M-TR

CONVERT DC/DC 3W 5V 600MA OUT
CUI