PSK-15W-12 [CUI]
INTERNAL AC-DC POWER SUPPLY;型号: | PSK-15W-12 |
厂家: | CUI INC |
描述: | INTERNAL AC-DC POWER SUPPLY |
文件: | 总7页 (文件大小:1044K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
date 06/30/2020
page 1 of 7
SERIES: PSK-15W │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
• wide input range (85~305 Vac)
• UL/EN/IEC 62368 certified
• meets CISPR32/EN 55032 Class B without external components
• short-circuit, over-current, over-voltage protections
output
voltage
output
current
max
output
power
max
ripple
and noise
efficiency
MODEL
typ
typ
(Vdc)
3.3
5
(A)
(W)
(mVp-p)
(%)
PSK-15W-3
PSK-15W-5
PSK-15W-9
PSK-15W-12
PSK-15W-15
PSK-15W-24
PSK-15W-48
3.0
2.8
9.9
14
15
15
15
15
15
50
50
50
50
50
50
50
73
76
78
80
80
83
85
9
1.6
12
15
24
48
1.25
1.0
0.625
0.32
PART NUMBER KEY
PSK - 15W - XX - X
Base Number
Output Voltage
Mounting Style
blank = board mount
T = chassis mount
DIN = DIN-rail mount
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/30/2020 │ page 2 of 7
INPUT
parameter
conditions/description
min
typ
max
units
85
100
305
430
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 155 Vac
at 230 Vac
.37
.22
A
A
inrush current
at 155 Vac
at 230 Vac
16
30
A
A
leakage current
277 Vac
0.25
mA
at 230 Vac
3.3, 5, 9, 12,15, 24 output
48 output
no load power consumption
0.5
0.55
W
W
OUTPUT
parameter
conditions/description
min
typ
max
units
3.3 Vdc output models
5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
48 Vdc output models
30,000
16,000
5,500
4,500
4,000
800
capacitive load
μF
220
all load range
3.3 V output
all other models
output voltage accuracy
±3
±2
%
%
line regulation
load regulation
rated load
±0.5
±1.0
%
%
0~100% load
at 155 Vac
at 230 Vac
5
40
ms
ms
hold-up time
temperature coefficient
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
units
Vdc
3.3 / 5 Vdc output models
9 Vdc output models
12 / 15 Vdc output models
24 Vdc output models
48 Vdc output models
7.5
15
20
30
60
over voltage protection
over current protection
short circuit protection
self recovery
150
300
Io%
hiccup, continuous, self recovery
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/30/2020 │ page 3 of 7
SAFETY & COMPLIANCE
parameter
conditions/description
input to output
min
4,000
typ
max
units
isolation voltage
safety approvals
safety class
Vac
IEC 62368/EN 62368/UL 62368
Class II
EMI/EMC
CISPR 32/EN 55032: 2015 Class B
ESD
IEC/EN 61000-4-2 Contact ±6KV/ Air ±8KV, perf. Criteria B
EC/EN 61000-4-3 10V/m, perf. Criteria A
IEC/EN 61000-4-4 ±2KV
radiated immunity
EFT/burst
IEC/EN 61000-4-4 ±4KV, perf. Criteria B, see recommended EMC circuit
IEC/EN 61000-4-5, line to line ±1KV, perf. Criteria B
IEC/EN 61000-4-5, line to line ±2kV, line to ground ±4kV perf. Criteria B, see recommended EMC circuit
EC/EN 61000-4-6 10Vr.m.s, perf. Criteria A
surge
conducted immunity
MTBF
as per MIL-HDBK-217F @ 25°C
300,000
hours
RoHS
yes
DERATING CURVE
EFFICIENCY CURVES
PSK-15W-48
PSK-15W-12
PSK-15W-5
PSK-15W-48
PSK-15W-12
PSK-15W-5
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/30/2020 │ page 4 of 7
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
85
units
°C
operating temperature
storage temperature
storage humidity
-40
-40
0
105
95
°C
non-condensing
%
SOLDERABILITY
parameter
conditions/description
for 5~10 seconds
min
255
350
typ
260
360
max
265
370
units
°C
wave soldering
hand soldering
for 3~5 seconds
°C
MECHANICAL
parameter
conditions/description
min
typ
max
units
62.00 x 45.00 x 22.50 (board mount)
96.10 x 54.00 x 31.00 (chassis mount)
96.10 x 54.00 x 35.60 (DIN-rail)
mm
mm
mm
dimensions
weight
board mount
chassis mount
DIN-rail
90
140
180
g
g
g
cooling
free air convection
case material
Black plastic, flame-retardant and heat-resistant (UL94V-0)
MECHANICAL DRAWING (BOARD MOUNT)
units: mm [inch]
tolerance: ±0.50 [±0.020]
pin diameter tolerances: ±0.10 [±0.004]
PIN CONNECTIONS
PIN
1
Function
no pin
AC (N)
AC (L)
+Vo
2
3
4
5
no pin
no pin
no pin
-Vo
6
7
8
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/30/2020 │ page 5 of 7
MECHANICAL DRAWING (CHASSIS MOUNT)
units: mm [inch]
tolerance: ±1.0 [±0.040]
wire range: 24~12 AWG
tightening torque: max 0.4 N·m
PIN CONNECTIONS
PIN
1
Function
NC
2
AC (N)
AC (L)
+Vo
NC
3
4
5
6
NC
7
NC
8
-Vo
MECHANICAL DRAWING (DIN-RAIL MOUNT)
units: mm [inch]
tolerance: ±1.00 [±0.040]
wire range: 24~12 AWG
tightening torque: max 0.4 N·m
PIN CONNECTIONS
PIN
1
Function
NC
2
AC (N)
AC (L)
+Vo
NC
3
4
5
6
NC
7
NC
8
-Vo
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/30/2020 │ page 6 of 7
APPLICATION CIRCUIT
Figure 1
Table 1
Recommended External Circuit Components
Vo
(Vdc)
FUSE6
MOV6
C1
C2
TVS
3.3
5
2A/300V S14K350
2A/300V S14K350
2A/300V S14K350
2A/300V S14K350
2A/300V S14K350
2A/300V S14K350
2A/300V S14K350
1 μF
1 μF
1 μF
1 μF
1 μF
1 μF
1 μF
680 μF
680 μF
470 μF
220 μF
220 μF
68 μF
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ64A
9
12
15
24
48
33 μF
Notes:
6. Chassis Mount and DIN-Rail Mount versions include the fuse and MOV components.
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Recommended External Circuit Components
S14K350
MOV
CY1/CY2
CX
1000 pF/400 Vac
0.1 µF/310 Vac
LCM
10 mH
L1
4.7 µH/ 2 A
FUSE
2 A/300 V, slow blow, required
Note:
Also refer to Table 1.
Notes:
7. C1 is a ceramic capacitor used to filter high frequency noise.
8. C2 is an electrolytic capacitor and it is recommended to be high frequency and low impedance. For capacitance and current of capacitor, refer to the datasheet provided by the
manufacturer. Voltage derating of capacitor should be at least 80%.
9. TVS is a recommended component to protect post-circuits (if converter fails).
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-15W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/30/2020 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
06/30/2020
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明