PSK-45-5 [CUI]
INTERNAL AC-DC POWER SUPPLY;型号: | PSK-45-5 |
厂家: | CUI INC |
描述: | INTERNAL AC-DC POWER SUPPLY |
文件: | 总7页 (文件大小:1910K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
date 07/13/2020
page 1 of 7
SERIES: PSK-45 │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
• universal input voltage range (85~264 VAC)
• IEC/EN/UL 62368 certified
• meets CISPR32/EN 55032 Class B without external components
• 4,000 VAC isolation rating
• short-circuit, over-current, over-voltage protections
output
voltage
output
current
max
output
power
max
ripple
and noise
efficiency
MODEL
max
typ
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
PSK-45-5
8.0
3.8
40
45
45
45
45
120
120
120
120
120
81
84
85
86
87
PSK-45-12
PSK-45-15
PSK-45-24
PSK-45-48
12
15
24
48
3.0
1.9
0.94
PART NUMBER KEY
PSK-45 - XX- X
Base Number
Output Voltage
Mounting Style
blank = board mount
T = chassis mount
DIN = DIN-rail mount
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/13/2020 │ page 2 of 7
INPUT
parameter
conditions/description
min
typ
max
units
ac input
dc input
85
100
264
370
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac
at 230 Vac
1.5
0.75
A
inrush current
at 115 Vac
at 230 Vac
50
70
A
no load power consumption
at 230 Vac
0.5
W
OUTPUT
parameter
conditions/description
min
typ
max
units
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
48 Vdc output
30,000
6,400
5,600
2,000
600
capacitive load
μF
initial set point accuracy
line regulation
at full load
±2
%
%
%
rated load
±0.5
±1.0
load regulation
0%~100% load
at 115 Vac
at 230 Vac
8
50
hold-up time
ms
temperature coefficient
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
units
V
5 Vdc output, clamp or hiccup
12 Vdc output, clamp or hiccup
15 Vdc output, clamp or hiccup
24 Vdc output, clamp or hiccup
48 Vdc output, clamp or hiccup
9
16
24
35
56
over voltage protection
over current protection
short circuit protection
auto recovery
110
%
hiccup, continuous, auto recovery
SAFETY & COMPLIANCE
parameter
conditions/description
input to output
min
typ
max
units
isolation voltage
safety approvals
safety class
4,000
Vac
UL/cUL, EN, IEC 62368
Class II
EMI/EMC
CISPR 32/EN 55032 Class B
ESD
IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV, perf. Criteria B
IEC/EN 61000-4-3 10 V/m, perf. Criteria A
radiated immunity
EFT/burst
IEC/EN 61000-4-4 ±4KV, perf. Criteria B
IEC/EN 61000-4-5 line to line +/-2kV/line to ground +/-4kV (see recommended EMC circuit)
IEC/EN 61000-4-5 line to line +/-1kV perf. Criteria B
surge
conducted immunity
IEC/EN 61000-4-6 10 Vr.m.s, perf. Criteria A
IEC/EN 61000-4-11 0%, 70%, perf. Criteria B
voltage dips and interruption
MTBF
per MIL-HDBK-217F at 25 °C
300,000
hours
RoHS
yes
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/13/2020 │ page 3 of 7
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/13/2020 │ page 4 of 7
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
70
units
°C
operating temperature
storage temperature
storage humidity
-40
-40
0
85
°C
95
%
SOLDERABILITY
parameter
conditions/description
5~10 seconds (± 5 °C)
3~5 seconds (± 10 °C)
min
typ
typ
max
260
360
units
°C
wave soldering
manual welding
°C
MECHANICAL
parameter
conditions/description
min
max
units
87.00 x 52.00 x 29.50 (board mount)
135.00 x 70.00 x 37.90 (chassis mount)
137.00 x 70.00 x 42.40 (DIN-rail)
mm
mm
mm
dimensions
weight
board mount
chassis mount
DIN-rail
205
290
360
g
g
g
cooling
free air convection
case material
black plastic, flame-retardant and heat-resistant (UL94V-0)
MECHANICAL DRAWING (BOARD MOUNT)
units: mm [inch]
pin diameter tolerance: ± 0.1 [±0.004]
PIN CONNECTIONS
PIN
1
Function
AC(L)
AC(N)
+Vo
2
3
4
-Vo
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/13/2020 │ page 5 of 7
MECHANICAL DRAWING (CHASSIS MOUNT)
units: mm [inch]
tolerance: ± 1.00 [±0.040]
wire range: 24 - 12 AWG
tightening torque: 0.4 N·m
PIN CONNECTIONS
PIN
1
Function
AC(L)
NC
2
3
AC(N)
+Vo
-Vo
4
5
6
NC
7
NC
8
NC
MECHANICAL DRAWING (DIN-RAIL MOUNT)
units: mm [inch]
tolerance: ± 1.00 [±0.040]
wire range: 24 - 12 AWG
tightening torque: 0.4 N·m
installed on DIN-RAIL TS35
PIN CONNECTIONS
PIN
1
Function
AC(L)
NC
2
3
AC(N)
+Vo
-Vo
4
5
6
NC
7
NC
8
NC
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/13/2020 │ page 6 of 7
APPLICATION CIRCUIT
Table 1
Recommended External Circuit Components
Figure 1
Part no.
PSK-45-5
PSK-45-12
PSK-45-15
C1
C2
FUSE
MOV
TVS
680 μF
220 μF
220 μF
SMBJ7.0A
SMBJ20A
SMBJ20A
3.15A/250V,
slow-blow
1 μF
S14K350
PSK-45-24
PSK-45-48
120 μF
100 μF
SMBJ30A
SMBJ64A
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Component
Reccomended value
FUSE
MOV1
MOV2/MOV3
GDT
3.15A/250V, slow-blow, required
S20K300
S10K300
EM3600XS
CX
0.22 μF/ 275 Vac
1 nF / 400 Vac
1 MΩ / 1 W
CY1, CY2
R1
LDM
4.7 uH
LCM
2 mH
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-45 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/13/2020 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
07/13/2020
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明