PSK-S12B-24 [CUI]
AC-DC POWER SUPPLY;型号: | PSK-S12B-24 |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总6页 (文件大小:965K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
date 02/25/2021
page 1 of 6
SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• universal input range (90 ~ 264 Vac)
• Class B emissions (EN55032/CISPR/FCC)
• certified to IEC/EN/UL 62368-1
• designed to meet IEC/EN 60335
• short circuit protection
• over voltage protection
• < 75 mW no-load power consumption
• Class II
output
voltage
output
current
output
power
max
ripple
efficiency2
MODEL
and noise1
min
max
max
typ
(Vdc)
5
(A)
(A)
(W)
(mVp-p)
(%)
PSK-S12B-5
PSK-S12B-9
PSK-S12B-12
PSK-S12B-15
PSK-S12B-24
0
2.0
1.34
1.0
10
12
12
12
12
100
100
120
150
240
80
85
85
85
87
9
0
12
15
24
0
0
0.8
0
0.5
Notes:
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 1 µF ceramic and 10 µF electrolytic capacitors on the output.
2. At 230 Vac, full load, 25°C.
3. All specifications are measured at Ta=25°C, nominal input voltage, and 75% rated output load unless otherwise specified.
PART NUMBER KEY
PSK-S12B - XX
Base Number
Output Voltage
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/25/2021 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
90
120
264
370
Vac
Vdc
voltage
frequency
47
63
400
50
Hz
mA
A
current
at 100 Vac, full load
at 240 Vac, cold start, 25°C
at 264 Vac
inrush current
leakage current
0.25
mA
OUTPUT
parameter
conditions/description
min
typ
max
units
5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
2,000
1,340
1,000
800
μF
μF
μF
μF
μF
capacitive load
500
initial set point accuracy
line regulation
at 100% load
±2
±1
±1
3
%
%
measured at high line to low line at full load
measured at 10%~100% load
load regulation
%
start-up time
s
hold-up time
at 115 Vac
10
65
ms
kHz
%/°C
switching frequency
temperature coefficient
±0.05
PROTECTIONS
parameter
conditions/description
min
typ
max
units
hiccup, auto recovery
5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
6.3
Vdc
Vdc
Vdc
Vdc
Vdc
12.6
15.8
18.9
31.5
over voltage protection
short circuit protection
hiccup, auto recovery
SAFETY & COMPLIANCE
parameter
conditions/description
min
3,000
100
typ
max
units
Vac
isolation voltage
input to output for 1 minute
isolation resistance
MΩ
certified to IEC/EN/UL 62368-1
designed to meet IEC/EN 60335
safety approvals
safety class
Class II
EN55032 2015, EN61000-6-3 2007+A1: 2011+AC: 2012, Class B,
47 CFR FCC Part 15 Subpart B (Class B)
conducted emissions
EN55032 2015, EN61000-6-3 2007+A1: 2011+AC: 2012, Class B,
47 CFR FCC Part 15 Subpart B (Class B)
radiated emissions
harmonic current emissions
voltage fluctuations & flicker
ESD
EN61000-3-2:2014
EN61000-3-3:2013
IEC61000-4-2:2008
IEC61000-4-3:2010
IEC61000-4-4:2012
IEC61000-4-5:2014
radiated immunity
EFT/burst
surge
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/25/2021 │ page 3 of 6
(
)
SAFETY & COMPLIANCE CONTINUED
parameter
conditions/description
min
typ
max
units
conducted immunity
IEC61000-4-6:2013
power frequency magnetic field IEC61000-4-8:2009
voltage dips & interruptions
IEC61000-4-11:2004
as per MIL-HDBK-217F, at 115 Vac, 25°C, GB
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
580,000
870,000
660,000
740,000
620,000
hours
hours
hours
hours
hours
MTBF
24 Vdc output model
RoHS
yes
Notes:
4. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
ENVIRONMENTAL
parameter
conditions/description
min
-40
-40
typ
max
75
units
°C
operating temperature
storage temperature
operating humidity
altitude
see derating curves
85
°C
non-condensing
93
%
5,000
m
as per MIL-STD-810F Table 514.5C-VIII; 15~2000
Hz for 1 hour on each axis for 3 hours
vibration
4
G
G
as per MIL-STD-810F Table 516.5, Table 516.5-1;
for 10 ms on each axis 3 times
shock
75
DERATING CURVE
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/25/2021 │ page 4 of 6
MECHANICAL
parameter
dimensions
weight
conditions/description
min
typ
max
units
inches
g
1.600 x 1.100 x 0.772 (40.64 x 27.94 x 19.60 mm)
40
MECHANICAL DRAWING
units: inch [mm]
tolerance: ±0.020[±0.50]
PIN CONNECTIONS
PIN
1
Function
AC (N)
AC (L)
-Vo
2
3
4
+Vo
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/25/2021 │ page 5 of 6
INSTALLATION INSTRUCTIONS
The mounting holes should all be 1.5 mm in diameter. A minimum of 4 mm clearance is required for all four sides of the
unit and a minimum of 5 mm clearance is required above the top surface of the unit.
cui.com
Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: PSK-S12B │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/25/2021 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
02/13/2020
02/25/2021
1.01
derating curve drawing updated
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明