SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• universal input range (85 ~ 264 Vac)  
• wide operating temperature range (-40 to +70 °C)  
• 4K Vac minimum isolation voltage  
• over-current, over-voltage, and short-circuit protection  
• low-profile encapsulated package (18 mm / 0.709”)  
• 85 mm (3.346”) leaded configuration available with  
“-L” suffix  
• chassis-mount configuration available with “-T” suffix  
• DIN-rail configuration available with “-DIN” suffix  
output  
voltage  
output  
current  
output  
power  
max  
ripple  
efficiency2  
MODEL  
and noise1  
min  
max  
max  
typ  
(Vdc)  
3.3  
5
(mA)  
(mA)  
(W)  
(mVp-p)  
(%)  
PSK-S3-3  
PSK-S3-5  
PSK-S3-9  
PSK-S3-12  
PSK-S3-15  
PSK-S3-24  
0
0
0
0
0
0
700  
600  
330  
250  
200  
125  
2.3  
3
100  
100  
100  
100  
100  
100  
66  
74  
75  
77  
77  
78  
9
3
12  
15  
24  
3
3
3
Notes:  
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 1 µF ceramic and 10 µF electrolytic capacitors on the output.  
2. At 230 Vac input.  
3. All specifications are measured at Ta=25°C, humidity <75%, nominal input voltage, and rated output load unless otherwise specified.  
PART NUMBER KEY  
PSK-S3 - XX - X  
Base Number  
Output Voltage  
Mounting Style:  
“blank” = board mount  
L = lead wires  
T = chassis mount  
DIN = DIN-rail mount  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2018 page 2 of 8  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
100  
264  
370  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 115 Vac  
at 230 Vac  
80  
45  
mA  
mA  
at 115 Vac  
at 230 Vac  
10  
20  
A
A
inrush current  
leakage current  
at 230 Vac, 50 Hz  
0.1  
mA  
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
3, 5 Vdc output models  
9, 12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
6000  
1500  
1000  
330  
µF  
µF  
µF  
µF  
capacitive load  
3.3 Vdc output models  
all other models  
±3  
±2  
%
%
initial set point accuracy  
line regulation  
load regulation  
at full load  
±0.5  
±1  
%
%
from 0~100% load  
at 115 Vac  
at 230 Vac  
10  
60  
ms  
ms  
hold-up time  
switching frequency  
100  
kHz  
temperature coefficient  
±0.02  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
3, 5 Vdc output models  
9 Vdc output models  
12, 15 Vdc output models  
24 Vdc output models  
7.5  
15  
20  
30  
Vdc  
Vdc  
Vdc  
Vdc  
over voltage protection  
over current protection  
auto recovery  
150  
%
short circuit protection  
continuous, auto recovery  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
input to output for 1 minute  
UL 62368-1, EN 62368-1, IEC 62368-1  
Class II  
min  
typ  
max  
units  
isolation voltage  
4,000  
Vac  
safety approvals  
safety class  
CISPR32/EN55032, Class A  
conducted emissions  
radiated emissions  
CISPR32/EN55032, Class B (external circuit required, see Figure 2)  
CISPR32/EN55032, Class A  
CISPR32/EN55032, Class B (external circuit required, see Figure 2)  
IEC/EN61000-4-2, contact ±6 kV/ air ±8kV, Class B  
IEC/EN61000-4-3, 10V/m, Class A  
ESD  
radiated immunity  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2018 page 3 of 8  
(
)
SAFETY & COMPLIANCE CONTINUED  
parameter  
conditions/description  
min  
typ  
max  
units  
IEC/EN61000-4-4, ±2 kV, Class B (external circuit required, see Figure 1)  
IEC/EN61000-4-4, ±4 kV, Class B (external circuit required, see Figure 2)  
EFT/burst  
IEC/EN61000-4-5, line to line ±1 kV, Class B (external circuit required, see Figure 1)  
surge  
IEC/EN61000-4-5, line to line ±2 kV/line to ground ±4 kV, Class B  
(external circuit required, see Figure 2)  
conducted immunity  
IEC/EN61000-4-6, 10 Vrms, Class A  
IEC/EN61000-4-11 Class B, 0%-70%  
voltage dips & interruptions  
MTBF  
RoHS  
as per MIL-HDBK-217F at 25°C  
300,000  
hours  
yes  
Notes:  
4. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-40  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
see derating curves  
105  
95  
°C  
non-condensing  
%
SOLDERABILITY5  
parameter  
conditions/description  
for 3~5 seconds  
min  
350  
255  
typ  
360  
260  
max  
370  
265  
units  
°C  
hand soldering  
wave soldering  
for 5~10 seconds  
°C  
Notes:  
5. For board mount models only  
Peak Temp. 260°C Max.  
Wave Soldering Time  
4 Sec. Max.  
250  
200  
150  
100  
10 Sec. Max.  
50  
0
Time (sec.)  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2018 page 4 of 8  
DERATING CURVES  
Load vs. Ambient Temperature  
(at 85~264 Vac / 100~370 Vdc Input Voltage)  
Load vs. Input Voltage  
(at 25°C Ambient Temperature)  
100  
85  
100  
80  
80  
60  
60  
40  
20  
40  
20  
-40  
-25  
55  
70  
85  
100  
264 Vac  
370 Vdc  
Ambient Temperature (°C)  
Input Voltage  
EFFICIENCY CURVES  
Efficiency vs. Input Voltage  
Efficiency vs. Load Current  
(at full load)  
(at 230 Vac)  
100  
80  
90  
85  
80  
70  
75  
70  
60  
50  
65  
PSK-S3-5  
PSK-S3-12  
PSK-S3-24  
PSK-S3-5  
PSK-S3-12  
PSK-S3-24  
60  
55  
50  
40  
30  
85  
110  
180  
230  
264  
10  
25  
40  
50  
65  
75  
90  
100  
Input Voltage (Vac)  
Load Current (%)  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2018 page 5 of 8  
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
board mount: 37.00 x 24.50 x 18.00 (1.457 x 0.965 x 0.709 inch)  
lead wires: 37.00 x 24.50 x 18.00 (1.457 x 0.965 x 0.709 inch)  
chassis mount: 76.00 x 31.50 x 26.80 (2.992 x 1.24 x 1.055 inch)  
DIN-Rail mount: 76.00 x 31.50 x 31.40 (2.992 x 1.24 x 1.236 inch)  
mm  
mm  
mm  
mm  
dimensions  
case material  
weight  
black flame-retardant and heat-resistant plastic (UL94V-0)  
board mount  
lead wires  
chassis mount  
DIN-Rail mount  
25  
25  
47  
69  
g
g
g
g
(
)
MECHANICAL DRAWING BOARD MOUNT  
units: mm[inch]  
tolerance: ±0.50[±0.020]  
pin diameter tolerance: ±0.10[±0.004]  
PIN CONNECTIONS  
PIN  
1
Function  
AC (L)  
AC (N)  
NC  
3
13  
14  
16  
-Vo  
+Vo  
Recommended PCB Layout  
Top View  
(
)
MECHANICAL DRAWING LEAD WIRES  
units: mm [inch]  
tolerance: ±0.50[±0.020]  
wire diameter tolerance: ±0.30[±0.012]  
WIRE CONNECTIONS  
PIN COLOR  
WIRE TYPE  
brown UL-1015 22 AWG AC (L)  
blue UL-1015 22 AWG AC (N)  
black UL-1430 22 AWG  
red UL-1430 22 AWG  
Function  
1
3
14  
16  
-Vo  
+Vo  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2018 page 6 of 8  
MECHANICAL DRAWING (CHASSIS MOUNT)  
units: mm[inch]  
tolerance: ±0.50[±0.020]  
wire range: 24~12 AWG  
tightening torque: max 0.4 N*m  
PIN CONNECTIONS  
PIN  
1
Function  
AC (N)  
AC (L)  
-Vo  
2
3
4
+Vo  
(
)
MECHANICAL DRAWING DIN-RAIL MOUNT  
units: mm [inch]  
tolerance: ±1.00[±0.039]  
installed on DIN Rail TS35  
wire range: 24~12 AWG  
tightening torque: max 0.4 N*m  
PIN CONNECTIONS  
PIN  
1
Function  
AC (N)  
AC (L)  
-Vo  
2
3
4
+Vo  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2018 page 7 of 8  
APPLICATION CIRCUIT  
Figure 1  
Table 1  
Recommended External Circuit Components  
Vo  
(Vdc)  
FUSE6  
MOV6  
C1  
C2  
TVS  
3.3  
5
1A/250V S14K350  
1A/250V S14K350  
1A/250V S14K350  
1A/250V S14K350  
1A/250V S14K350  
1A/250V S14K350  
1 μF  
1 μF  
1 μF  
1 μF  
1 μF  
1 μF  
150 μF  
150 μF  
120 μF  
120 μF  
120 μF  
68 μF  
SMBJ7.0A  
SMBJ7.0A  
SMBJ12A  
SMBJ20A  
SMBJ20A  
SMBJ30A  
9
12  
15  
24  
Notes:  
6. Chassis Mount and DIN-Rail Mount versions include the fuse and MOV components.  
EMC RECOMMENDED CIRCUIT  
Figure 2  
Table 2  
Recommended External Circuit Components  
FUSE  
2 A/250 V, slow fusing  
S14K350  
MOV  
LCM  
CX  
10~30 mH  
0.1 µF/275 Vac  
330 µH/ 2 A  
1 nF/400 Vac  
33 Ω/3 W  
L1  
CY1/CY2  
R0  
Note:  
Also refer to Table 1.  
Notes:  
7. C1 is a ceramic capacitor used to filter high frequency noise.  
8. C2 is an electrolytic capacitor and it is recommended to be high frequency and low impedance. For capacitance and current of capacitor, refer to the datasheet provided by the  
manufacturer. Voltage derating of capacitor should be at least 80%.  
9. TVS is a recommended component to protect post-circuits (if converter fails).  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSK-S3 DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2018 page 8 of 8  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
11/12/2018  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

PSK-S5B

AC-DC POWER SUPPLY
CUI

PSK-S5B-12

AC-DC POWER SUPPLY
CUI

PSK-S5B-15

AC-DC POWER SUPPLY
CUI

PSK-S5B-24

AC-DC POWER SUPPLY
CUI

PSK-S5B-3

AC-DC POWER SUPPLY
CUI

PSK-S5B-5

AC-DC POWER SUPPLY
CUI

PSK-S5B-5-DIN

5 Vdc, 1 A, 5 W
CUI

PSK-S5B-9

AC-DC POWER SUPPLY
CUI

PSK-S5B-9-DIN

9 Vdc, 560 mA, 5 W
CUI

PSK-S5B-L

AC-DC POWER SUPPLY
CUI

PSK-S60B

AC-DC POWER SUPPLY
CUI

PSK-S60B-12

AC-DC POWER SUPPLY
CUI