PSK-S6C-T [CUI]
AC-DC POWER SUPPLY;型号: | PSK-S6C-T |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总8页 (文件大小:1722K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
date 02/26/2021
page 1 of 8
SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• universal input (85~264 Vac)
• -40~70°C operating range
• over voltage/current protection
• 4,000 Vac input/output isolation voltage
• board/chassis/DIN-Rail configurations
• CISPR32/EN55032 Class B
• UL/EN/IEC 62368-1 certified
output
voltage
output
current
output
power
max
ripple
efficiency2
MODEL
and noise1
min
max
max
typ
(Vdc)
3.3
5
(mA)
(mA)
(W)
(mVp-p)
(%)
PSK-S6C-3
PSK-S6C-5
PSK-S6C-9
PSK-S6C-12
PSK-S6C-15
PSK-S6C-24
0
0
0
0
0
0
1250
1200
660
4.1
6
100
100
100
100
100
100
70
76
74
77
77
80
9
6
12
15
24
500
6
400
6
250
6
Notes:
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 1 µF ceramic and 10 µF electrolytic capacitors on the output.
2. At 230 Vac input.
3. All specifications are measured at Ta=25°C, humidity <75%, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
PSK-S6C - XX - X
Base Number
Output Voltage
Mounting Style:
“blank” = board mount
T = chassis mount
DIN = DIN-rail mount
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/26/2021 │ page 2 of 8
INPUT
parameter
conditions/description
min
typ
max
units
85
100
264
370
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac
at 230 Vac
150
100
mA
mA
at 115 Vac
at 230 Vac
10
20
A
A
inrush current
no load power consumption
0.5
W
OUTPUT
parameter
conditions/description
min
typ
max
units
3.3, 5 Vdc output models
9 Vdc output models
12, 15 Vdc output models
24 Vdc output models
4,000
1,000
820
µF
µF
µF
µF
capacitive load
330
3.3 Vdc output models
all other models
±3
±2
%
%
initial set point accuracy
line regulation
load regulation
at full load
±0.5
±1
%
%
from 0~100% load
at 115 Vac, full load
at 230 Vac, full load
8
60
ms
ms
hold-up time
switching frequency
100
kHz
temperature coefficient
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
units
output voltage clamp
3.3, 5 Vdc output models
9 Vdc output models
12, 15 Vdc output models
24 Vdc output models
7.5
15
20
30
Vdc
Vdc
Vdc
Vdc
over voltage protection
over current protection
auto recovery
110
%
short circuit protection
hiccup, continuous, auto recovery
SAFETY & COMPLIANCE
parameter
conditions/description
input to output for 1 minute
UL 62368-1, EN 62368-1, IEC 62368-1
Class II
min
typ
max
units
isolation voltage
safety approvals
safety class
4,000
Vac
conducted emissions
radiated emissions
ESD
CISPR32/EN55032, Class B
CISPR32/EN55032, Class B
IEC/EN61000-4-2, contact ±6 kV/ air ±8 kV, Class B
IEC/EN61000-4-3, 10 V/m, Class A
radiated immunity
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/26/2021 │ page 3 of 8
(
)
SAFETY & COMPLIANCE CONTINUED
parameter
conditions/description
min
typ
max
units
IEC/EN61000-4-4, ±2 kV, Class B
EFT/burst
IEC/EN61000-4-4, ±4 kV, Class B (external circuit required, see Figure 2)
IEC/EN61000-4-6, 10 Vrms, Class A
conducted immunity
voltage dips & interruptions
IEC/EN61000-4-11 Class B, 0%-70%
MTBF
RoHS
as per MIL-HDBK-217F at 25°C
300,000
hours
yes
Notes:
4. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
ENVIRONMENTAL
parameter
conditions/description
min
-40
-40
typ
max
70
units
°C
operating temperature
storage temperature
storage humidity
see derating curves
105
95
°C
non-condensing
%
SOLDERABILITY5
parameter
conditions/description
for 3~5 seconds
min
350
255
typ
360
260
max
370
265
units
°C
hand soldering
wave soldering
for 5~10 seconds
°C
Notes:
5. For board mount models only
Peak Temp. 260°C Max.
Wave Soldering Time
4 Sec. Max.
250
200
150
100
10 Sec. Max.
50
0
Time (sec.)
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/26/2021 │ page 4 of 8
DERATING CURVES
EFFICIENCY CURVES
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/26/2021 │ page 5 of 8
MECHANICAL
parameter
conditions/description
min
typ
max
units
board mount: 50.80 x 25.40 x 15.36 (2.00 x 1.00 x 0.605 inch)
chassis mount: 76.00 x 31.50 x 24.16 (2.992 x 1.24 x 0.951 inch)
DIN-Rail mount: 76.00 x 31.50 x 28.76 (2.992 x 1.24 x 1.132 inch)
mm
mm
mm
dimensions
case material
weight
black flame-retardant and heat-resistant plastic (UL94V-0)
board mount
chassis mount
DIN-Rail mount
31
52
70
g
g
g
(
)
MECHANICAL DRAWING BOARD MOUNT
units: mm[inch]
tolerance: ±0.50[±0.020]
pin diameter tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
1
Function
AC (N)
AC (L)
-Vo
2
3
4
+Vo
Recommended PCB Layout
Top View
MECHANICAL DRAWING (CHASSIS MOUNT)
units: mm[inch]
tolerance: ±1.00[±0.039]
wire range: 24~12 AWG
tightening torque: max 0.4 N*m
PIN CONNECTIONS
PIN
1
Function
AC (N)
AC (L)
-Vo
2
3
4
+Vo
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/26/2021 │ page 6 of 8
(
)
MECHANICAL DRAWING DIN-RAIL MOUNT
units: mm [inch]
tolerance: ±1.00[±0.039]
installed on DIN Rail TS35
wire range: 24~12 AWG
tightening torque: max 0.4 N*m
PIN CONNECTIONS
PIN
1
Function
AC (N)
AC (L)
-Vo
2
3
4
+Vo
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/26/2021 │ page 7 of 8
APPLICATION CIRCUIT
Figure 1
Table 1
Recommended External Circuit Components
Vo
(Vdc)
FUSE
MOV
C1
C2
TVS
3.3
5
1A/250V S14K350
1A/250V S14K350
1A/250V S14K350
1A/250V S14K350
1A/250V S14K350
1A/250V S14K350
1 μF
1 μF
1 μF
1 μF
1 μF
1 μF
220 μF
220 μF
100 μF
100 μF
100 μF
47 μF
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
9
12
15
24
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Recommended External Circuit Components
FUSE
2 A/250 V, slow fusing
S14K350
MOV
LCM
CX
2.2 mH
0.1 μF/275 Vac
1 nF/400 Vac
47 µH/ 2 A
CY1, CY2
L1
R0
33 Ω/3 W
Note:
Also refer to Table 1.
Notes:
6. C1 is a ceramic capacitor used to filter high frequency noise.
7. C2 is an electrolytic capacitor and it is recommended to be high frequency and low impedance. For capacitance and current of capacitor, refer to the datasheet provided by the
manufacturer. Voltage derating of capacitor should be at least 80%.
8. TVS is a recommended component to protect post-circuits (if converter fails).
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: PSK-S6C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/26/2021 │ page 8 of 8
REVISION HISTORY
rev.
description
date
1.0
initial release
03/07/2019
02/05/2021
02/26/2021
1.01
1.02
company logo updated
figure and circuit drawings updated
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明