SDI160-24-U-P51 [CUI]
AC-DC POWER SUPPLY;型号: | SDI160-24-U-P51 |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总5页 (文件大小:547K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
date 10/14/2020
page 1 of 5
SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•ꢀmeetsꢀLevelꢀVIꢀandꢀCoCꢀTierꢀ2ꢀefficiency
• up to 160 W power
• universal input (100~240 Vac)
• single regulated outputs
• over voltage and short circuit protections
•ꢀmeetsꢀUL/cULꢀ62368ꢀ&ꢀENꢀ62368
• power factor correction
• custom designs available
output
voltage
output
current
max
output
power
max
ripple
efficiency
MODEL
and noise1
level2
max
(Vdc)
12
(A)
(W)
(mVp-p)
SDI160-12-U-P51
SDI160-19-U-P51
SDI160-24-U-P51
SDI160-48-U-P51
SDI160-56-U-P51
12.5
8.4
150.0
159.6
158.4
158.4
160.1
120
190
240
480
560
VI
VI
VI
VI
VI
19
24
6.6
48
3.3
56
2.86
Notes:ꢀ
1.ꢀAtꢀfullꢀload,ꢀnominalꢀinput,ꢀ20ꢀMHzꢀbandwidthꢀoscilloscope,ꢀeachꢀoutputꢀterminatedꢀwithꢀ0.1ꢀμFꢀmultilayerꢀceramicꢀandꢀ10ꢀμFꢀlowꢀESRꢀelectrolyticꢀcapacitors.
2. CoC Tier 2 compliant
PART NUMBER KEY
SDI160 - XX - UX- P51- CXX
ReservedꢀforꢀCustomꢀ
Configurations
Base Number
DCꢀPlugꢀType
Output Voltage
Input cable:
“Blank” = No Cable
C = North America input cable
2ꢀ=ꢀEuropeꢀinputꢀcable
ACꢀInletꢀType:
IEC320/C14
3 = United Kingdom input cable
4 = Australia input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/14/2020 │ page 2 of 5
INPUT
parameter
voltage
conditions/description
min
100
50
typ
max
240
60
units
Vac
Hz
frequency
current
2.2
100
3.5
A
inrush current
leakage current
power factor
no load power consumption
at 230 Vac, full load, 25°C, cold start
A
mA
full load
0.9
min
min
at 230 Vac
0.15
W
OUTPUT
parameter
regulation
conditions/description
typ
max
units
±5
%
PROTECTIONS
parameter
conditions/description
typ
max
150
150
units
%
over voltage protection
over current protection
short circuit protection
output shut down, latch
outputꢀshutꢀdown,ꢀautoꢀrecovery
outputꢀshutꢀdown,ꢀautoꢀrecovery
%
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to output at 10 mA for 1 minute
input to frame ground at 10 mA for 1 minute
3,000
1,500
Vac
Vac
isolation voltage
input to output at 500 Vdc
input to frame ground at 500 Vdc
10
10
MΩ
MΩ
isolation resistance
safetyꢀmarks
UL/cULꢀ(NorthꢀAmerica),ꢀCEꢀ(Europe),ꢀFCCꢀ(USA)
62368:ꢀUL/cUL,ꢀEN
safetyꢀapprovals
FCCꢀPartꢀ15ꢀClassꢀB,ꢀ
ENꢀ55032:2012ꢀ+AC:2013ꢀClassꢀB,ꢀ
AS/NZSꢀCISPRꢀ32:2015ꢀClassꢀB,ꢀ
EN55024:2010
EMI/EMC
MTBF
RoHS
asꢀperꢀTelcordiaꢀSR-332,ꢀ25°C
yes
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
0
typ
max
40
units
°C
operating temperature
storage temperature
operatingꢀhumidity
storageꢀhumidity
-20
20
80
°C
non-condensing
non-condensing
80
%
10
90
%
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/14/2020 │ page 3 of 5
MECHANICAL
parameter
dimensions
inlet plug
conditions/description
175.2 x 74.0 x 42.0
IEC320/C14
min
typ
max
units
mm
weight
700
g
MECHANICAL DRAWING
units: mm
tolerance: ±1.0 mm
DC CORD
units: mm
Table 1
MODEL NO.
CABLE
CORD LENGTH
1,200 mm ±50
1,500 mm ±50
1,500 mm ±50
1,500 mm ±30
1,500 mm ±50
SDI160-12-U-P51
SDI160-19-U-P51
SDI160-24-U-P51
SDI160-48-U-P51
SDI160-56-U-P51
UL2464, 16 AWG
UL2464, 16 AWG
UL2464, 16 AWG
UL2464, 18 AWG
UL2464, 18 AWG
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/14/2020 │ page 4 of 5
AC CORD
units: mm
cord length
EUROPE
CHINA
UNITED KINGDOM
NORTH AMERICA
SOUTH KOREA
AUSTRALIA
BRAZIL
SOUTH AFRICA
JAPAN
Table 2
AC INPUT
North America
Europe
CORD LENGTH
1,830 mm ±30
1,830 mm ±30
1,830 mm ±30
1,830 mm ±30
1,830 mm ±30
1,830 mm ±50
1,830 mm ±30
1,830 mm ±50
1,830 mm ±30
United Kingdom
Australia
China
South Korea
Brazil
South Africa
Japan
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: SDI160-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/14/2020 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
09/28/2020
10/14/2020
1.01
dc cord drawing update
Theꢀrevisionꢀhistoryꢀprovidedꢀisꢀforꢀinformationalꢀpurposesꢀonlyꢀandꢀisꢀbelievedꢀtoꢀbeꢀaccurate.
Headquarters
20050 SW 112th Ave.
Tualatin,ꢀORꢀ97062
800.275.4899
Faxꢀ503.612.2383
cui.com
techsupport@cui.com
Thisꢀdeviceꢀcompliesꢀwithꢀpartꢀ15ꢀofꢀtheꢀFCCꢀRules.ꢀOperationꢀisꢀsubjectꢀtoꢀtheꢀfollowingꢀtwoꢀconditions:ꢀ
(1)ꢀThisꢀdeviceꢀmayꢀnotꢀcauseꢀharmfulꢀinterference,ꢀandꢀ
(2)ꢀthisꢀdeviceꢀmustꢀacceptꢀanyꢀinterferenceꢀreceived,ꢀincludingꢀinterferenceꢀthatꢀmayꢀcauseꢀundesiredꢀoperation.
CUIꢀoffersꢀaꢀoneꢀ(1)ꢀyearꢀlimitedꢀwarranty.ꢀꢀCompleteꢀwarrantyꢀinformationꢀisꢀlistedꢀonꢀourꢀwebsite.
CUIꢀreservesꢀtheꢀrightꢀtoꢀmakeꢀchangesꢀtoꢀtheꢀproductꢀatꢀanyꢀtimeꢀwithoutꢀnotice.ꢀꢀInformationꢀprovidedꢀbyꢀCUIꢀisꢀbelievedꢀtoꢀbeꢀaccurateꢀandꢀreliable.ꢀꢀHowever,ꢀnoꢀresponsibilityꢀisꢀ
assumedꢀbyꢀCUIꢀforꢀitsꢀuse,ꢀnorꢀforꢀanyꢀinfringementsꢀofꢀpatentsꢀorꢀotherꢀrightsꢀofꢀthirdꢀpartiesꢀwhichꢀmayꢀresultꢀfromꢀitsꢀuse.
CUIꢀproductsꢀareꢀnotꢀauthorizedꢀorꢀwarrantedꢀforꢀuseꢀasꢀcriticalꢀcomponentsꢀinꢀequipmentꢀthatꢀrequiresꢀanꢀextremelyꢀhighꢀlevelꢀofꢀreliability.ꢀꢀAꢀcriticalꢀcomponentꢀisꢀanyꢀcomponentꢀofꢀaꢀ
lifeꢀsupportꢀdeviceꢀorꢀsystemꢀwhoseꢀfailureꢀtoꢀperformꢀcanꢀbeꢀreasonablyꢀexpectedꢀtoꢀcauseꢀtheꢀfailureꢀofꢀtheꢀlifeꢀsupportꢀdeviceꢀorꢀsystem,ꢀorꢀtoꢀaffectꢀitsꢀsafetyꢀorꢀeffectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明