SERIES: SWI24-SC │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• 24 W power
• universal input (90~264 Vac)
• single regulated 12~24 Vdc output
• short circuit, over current, and over voltage protections
• UL 60950 & UL 1310 safety approvals
• level VI efficiency
output
voltage
output
current
max
output
power
max
ripple
efficiency
MODEL
and noise1
level
max
(Vdc)
12
(A)
(W)
(mVp-p)
SWI24-12-N-SC
SWI24-15-N-SC
SWI24-24-N-SC
2
1.6
1
24
24
24
120
150
240
VI
VI
VI
15
24
Notes:ꢀ
1.ꢀAtꢀfullꢀload,ꢀnominalꢀinput,ꢀ20ꢀMHzꢀbandwidthꢀoscilloscope,ꢀeachꢀoutputꢀterminatedꢀwithꢀ0.1ꢀμFꢀmultilayerꢀceramicꢀandꢀ10ꢀμFꢀlowꢀESRꢀelectrolyticꢀcapacitors.
PART NUMBER KEY
SWI24 - XX - N - SC - CXX
Reserved for Custom
Base Number
Configurations
Output Voltage
DC Output Type:
Screw Terminals
AC Input Type
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │SERIES: SWI24-SC │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/12/2015 │ page 2 of 4
INPUT
parameter
conditions/description
min
90
typ
max
264
63
units
Vac
Hz
voltage
frequency
47
current
at full load
0.6
30
A
inrush current
leakage current
no load power consumption
at 115 Vac, full load, 25°C, cold start
A
0.25
0.1
mA
W
at 230 Vac
OUTPUT
parameter
regulation
conditions/description
min
typ
max
units
%
±5
start-up time
hold-up time
at 110 Vac/50 Hz, 80% load
at 110 Vac/50 Hz, 80% load
3
s
10
ms
PROTECTIONS
parameter
conditions/description
output shutdown
min
typ
max
200
200
units
%
over voltage protection
over current protection
short circuit protection
output shut down, auto recovery
output shut down, auto recovery
%
SAFETY & COMPLIANCE
parameter
conditions/description
input to output at 10 mA for 1 minute
input to output at 500 Vdc
UL/cUL (UL 60950, UL 1310), LPS
FCCꢀPartꢀ15BꢀClassꢀB
min
typ
max
units
Vac
isolation voltage
isolation resistance
safety approvals
EMI/EMC
3,000
10
MΩ
MTBF
as per Telcordia SR-332, 25°C
2011/65/EU
300,000
hours
RoHS
ENVIRONMENTAL
parameter
conditions/description
min
0
typ
max
40
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
-25
10
85
°C
non-condensing
non-condensing
95
%
10
95
%
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │SERIES: SWI24-SC │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/12/2015 │ page 3 of 4
MECHANICAL
parameter
dimensions
input plug
conditions/description
98 x 49 x 32.5
min
typ
max
units
mm
US 2-pin
MECHANICAL DRAWING
units: mm
tolerance: ±1 mm
MAXIMUM RECOMMENDED CABLE LENGTH TO MAINTAIN
±5% OUTPUT VOLTAGE TOLERANCE
MODELꢀNO.
CABLEꢀGAUGE
18ꢀAWG
20ꢀAWG
22ꢀAWG
24ꢀAWG
18ꢀAWG
20ꢀAWG
22ꢀAWG
24ꢀAWG
18ꢀAWG
20ꢀAWG
22ꢀAWG
24ꢀAWG
MAXꢀCABLEꢀLENGTH
6.5 m
SWI24-12-N-SC
SWI24-12-N-SC
SWI24-12-N-SC
SWI24-12-N-SC
SWI24-15-N-SC
SWI24-15-N-SC
SWI24-15-N-SC
SWI24-15-N-SC
SWI24-24-N-SC
SWI24-24-N-SC
SWI24-24-N-SC
SWI24-24-N-SC
4.5 m
3.0 m
2.0 m
8.0 m
5.5 m
4.0 m
2.5 m
13.0 m
9.0 m
6.5 m
3.5 m
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │SERIES: SWI24-SC │ DESCRIPTION: AC-DC POWER SUPPLY
date 10/12/2015 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
added max cable length information
updated datasheet
12/04/2014
02/10/2015
10/12/2015
1.01
1.02
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Faxꢀ503.612.2383
cui.com
techsupport@cui.com
Thisꢀdeviceꢀcompliesꢀwithꢀpartꢀ15ꢀofꢀtheꢀFCCꢀRules.ꢀOperationꢀisꢀsubjectꢀtoꢀtheꢀfollowingꢀtwoꢀconditions:ꢀ
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明