SWI5-N-USB [CUI]
AC-DC POWER SUPPLY;型号: | SWI5-N-USB |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总4页 (文件大小:824K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date 04/30/2015
page 1 of 4
SERIES: SWI5-N-USB │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• 5 W power
•ꢀlevelꢀVIꢀefficiencyꢀ
• universal input (90~264 Vac)
• single regulated 5 Vdc output
• over voltage, over current, and short circuit protections
•ꢀUL/cUL,ꢀPSEꢀsafetyꢀapprovals
output
voltage
output
current
max
output
power
max
ripple
efficiency
MODEL
and noise1
level
max
(Vdc)
5
(A)
(W)
(mVp-p)
SWI5-5-N-I38
1
5
300
VI
Notes:ꢀ
1.ꢀAtꢀfullꢀload,ꢀnominalꢀinput,ꢀ25ꢀ°C,ꢀ20ꢀMHzꢀbandwidthꢀoscilloscope,ꢀeachꢀoutputꢀterminatedꢀwithꢀ0.1ꢀμFꢀceramicꢀandꢀ10ꢀμFꢀelectrolyticꢀcapacitors.
PART NUMBER KEY
SWI5 - 5 - N - I38 - CXX
Base Number
Reserved for Custom
Configurations
Output Voltage
ACꢀInputꢀType:
North America
USBꢀTypeꢀAꢀInlet
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │SERIES: SWI5-N-USB │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/30/2015│ page 2 of 4
INPUT
parameter
conditions/description
min
90
typ
max
264
units
Vac
Hz
voltage
frequency
47
63
current
0.2
A
leakage current
no load power consumption
0.02
0.075
mA
W
at 115/230 Vac, 50/60 Hz
OUTPUT
parameter
conditions/description
min
min
typ
±5
±5
max
units
%
line regulation
load regulation
start-up time
%
3
s
PROTECTIONS
parameter
conditions/description
typ
max
10
units
Vdc
A
over voltage protection
over current protection
short circuit protection
autoꢀrecovery
1.5
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
3,000
4,242
Vac
Vdc
isolation voltage
input to output at 10 mA for 1 minute
safetyꢀapprovals
UL/cUL (UL60950-1), LPS, PSE
EMI/EMC
FCCꢀPartꢀ15ꢀClassꢀB
as per Telcordia SR-332, Issue 2, at 115/230 Vac,
full load, 0~40°C
MTBF
50,000
hours
RoHS
2011/65/EU
ENVIRONMENTAL
parameter
conditions/description
min
0
typ
max
40
units
°C
operating temperature
storage temperature
operatingꢀhumidity
storageꢀhumidity
-20
20
5
60
°C
non-condensing
non-condensing
85
%
95
%
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │SERIES: SWI5-N-USB │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/30/2015│ page 3 of 4
MECHANICAL
parameter
dimensions
input plug
weight
conditions/description
64.92 x 36 x 22.5
min
typ
max
units
mm
North America, 2-pin
80
g
MECHANICAL DRAWING
units: mm
tolerance: ±0.5 mm
PIN
1
Output Voltage
+5V
2
Short
3
Short
4
GND
+5
1
4
GND
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │SERIES: SWI5-N-USB │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/30/2015│ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
04/30/2015
Theꢀrevisionꢀhistoryꢀprovidedꢀisꢀforꢀinformationalꢀpurposesꢀonlyꢀandꢀisꢀbelievedꢀtoꢀbeꢀaccurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Faxꢀ503.612.2383
cui.com
techsupport@cui.com
Thisꢀdeviceꢀcompliesꢀwithꢀpartꢀ15ꢀofꢀtheꢀFCCꢀRules.ꢀOperationꢀisꢀsubjectꢀtoꢀtheꢀfollowingꢀtwoꢀconditions:ꢀ
(1)ꢀThisꢀdeviceꢀmayꢀnotꢀcauseꢀharmfulꢀinterference,ꢀandꢀ
(2)ꢀthisꢀdeviceꢀmustꢀacceptꢀanyꢀinterferenceꢀreceived,ꢀincludingꢀinterferenceꢀthatꢀmayꢀcauseꢀundesiredꢀoperation.
CUIꢀoffersꢀaꢀoneꢀ(1)ꢀyearꢀlimitedꢀwarranty.ꢀꢀCompleteꢀwarrantyꢀinformationꢀisꢀlistedꢀonꢀourꢀwebsite.
CUIꢀreservesꢀtheꢀrightꢀtoꢀmakeꢀchangesꢀtoꢀtheꢀproductꢀatꢀanyꢀtimeꢀwithoutꢀnotice.ꢀꢀInformationꢀprovidedꢀbyꢀCUIꢀisꢀbelievedꢀtoꢀbeꢀaccurateꢀandꢀreliable.ꢀꢀHowever,ꢀnoꢀresponsibilityꢀisꢀ
assumedꢀbyꢀCUIꢀforꢀitsꢀuse,ꢀnorꢀforꢀanyꢀinfringementsꢀofꢀpatentsꢀorꢀotherꢀrightsꢀofꢀthirdꢀpartiesꢀwhichꢀmayꢀresultꢀfromꢀitsꢀuse.
CUIꢀproductsꢀareꢀnotꢀauthorizedꢀorꢀwarrantedꢀforꢀuseꢀasꢀcriticalꢀcomponentsꢀinꢀequipmentꢀthatꢀrequiresꢀanꢀextremelyꢀhighꢀlevelꢀofꢀreliability.ꢀꢀAꢀcriticalꢀcomponentꢀisꢀanyꢀcomponentꢀofꢀaꢀ
lifeꢀsupportꢀdeviceꢀorꢀsystemꢀwhoseꢀfailureꢀtoꢀperformꢀcanꢀbeꢀreasonablyꢀexpectedꢀtoꢀcauseꢀtheꢀfailureꢀofꢀtheꢀlifeꢀsupportꢀdeviceꢀorꢀsystem,ꢀorꢀtoꢀaffectꢀitsꢀsafetyꢀorꢀeffectiveness.
相关型号: