PART NUMBER: VD-120A  
DESCRIPTION: dual output switching power supply  
Features  
·Low cost, high reliability  
·105°C output capacitor  
·Universal AC input range  
·High efficiency, low temperature rise  
·Soft-start circuit, limiting AC surge current  
·Short circuit, overload, over-voltage protected  
·Compact size, light weight  
·100% full load burn-in test  
·Built-in EMI filter, low ripple noise  
CH1  
CH2  
DC output voltage  
Output V. tolerance  
Output rated current  
Output current range  
Ripple & noise  
5V  
12V  
±2%  
±6%  
12A  
5A  
2-12A  
60mVp-p  
±0.5%  
±0.5%  
120W  
78%  
0.5-5A  
120mVp-p  
±1.0%  
±5.0%  
Line regulation  
Load regulation  
DC output power  
Efficiency  
DC voltage adj.  
Input voltage range  
AC current  
CH1:+10,-5%  
88~132VAC/176~264VAC selected by switch, 47~63Hz; or 248~370VDC  
2.5A/115V 1.25A/230V  
Inrush current  
cold start 35A  
Leakage current  
Overload protection  
<3.5mA/240VAC  
105%~135% shutoff  
AC recycle to restart  
Over voltage protection  
Temperature coefficient  
Set up, rise, hold up time  
Vibration  
CH1:5.75V~6.75V  
±0.03% / ºC (0~50ºC) ON +5V output  
200ms, 50ms, 20ms  
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes  
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.  
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.  
-10°C~+60% (refer to output derating curve), 20%-90% RH  
-20°C~+85°C, 10%-95% RH  
Withstand voltage  
Isolation resistance  
Working temp., humidity  
Storage temp., humidity  
Dimensions  
7.83x4.33x1.97inches (199x110x50mm)  
1.94lbs. (0.88Kgs)  
Weight  
Safety standards  
EMC standards  
UL1950, TUV EN60950  
CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 verification  
Notes:  
1. All parameters are specified at 230VAC input, rated load, 25°C 70% ambient  
2. Tolerance includes set up tolerance, line regulation, load regulation  
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor  
4. Line regulation is measured from low line to high line at rated load  
5. Load regulation is measured from 0% to 100% rated load  
6. Each output provides up to maximum current, but total load can not exceed max. output power  
7. C2, C3, C11 must be removed  
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise cus-  
tomers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for cus-  
tomer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub-  
lished specifications. Nothing will be covered outside of standard product warranty.  
th  
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382  
2 of 2  
page  
date  
05/2008  
PART NUMBER: VD-120A  
DESCRIPTION: dual output switching power supply  
Block Diagram  
Static Characteristics  
Output Derating  
Dimensions (mm)  
th  
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382  

相关型号:

VD-120B

Dual Output Switching Power Supply
CUI

VD-3733

VDSL TRANSFORMER
BOTHHAND

VD-4008

VDSL TRANSFORMER
BOTHHAND

VD-4025

VDSL TRANSFORMER
BOTHHAND

VD-4025A

VDSL TRANSFORMER
BOTHHAND

VD-60A

Metal Enclosed Switching Power Supply
CUI

VD-60B

Metal Enclosed Switching Power Supply
CUI

VD-7008

HPF OVER VDSL
BOTHHAND

VD-7010

ISDN SPLITTER
BOTHHAND

VD-7010A

ISDN SPLITTER
BOTHHAND

VD-7010B

ISDN SPLITTER
BOTHHAND

VD-7012

VDSL BANDPASS FILTER
BOTHHAND