PART NUMBER: VD-120A
DESCRIPTION: dual output switching power supply
Features
·Low cost, high reliability
·105°C output capacitor
·Universal AC input range
·High efficiency, low temperature rise
·Soft-start circuit, limiting AC surge current
·Short circuit, overload, over-voltage protected
·Compact size, light weight
·100% full load burn-in test
·Built-in EMI filter, low ripple noise
CH1
CH2
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise
5V
12V
±2%
±6%
12A
5A
2-12A
60mVp-p
±0.5%
±0.5%
120W
78%
0.5-5A
120mVp-p
±1.0%
±5.0%
Line regulation
Load regulation
DC output power
Efficiency
DC voltage adj.
Input voltage range
AC current
CH1:+10,-5%
88~132VAC/176~264VAC selected by switch, 47~63Hz; or 248~370VDC
2.5A/115V 1.25A/230V
Inrush current
cold start 35A
Leakage current
Overload protection
<3.5mA/240VAC
105%~135% shutoff
AC recycle to restart
Over voltage protection
Temperature coefficient
Set up, rise, hold up time
Vibration
CH1:5.75V~6.75V
±0.03% / ºC (0~50ºC) ON +5V output
200ms, 50ms, 20ms
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
7.83x4.33x1.97inches (199x110x50mm)
1.94lbs. (0.88Kgs)
Weight
Safety standards
EMC standards
UL1950, TUV EN60950
CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 verification
Notes:
1. All parameters are specified at 230VAC input, rated load, 25°C 70% ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 0% to 100% rated load
6. Each output provides up to maximum current, but total load can not exceed max. output power
7. C2, C3, C11 must be removed
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise cus-
tomers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for cus-
tomer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub-
lished specifications. Nothing will be covered outside of standard product warranty.
th
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
2 of 2
page
date
05/2008
PART NUMBER: VD-120A
DESCRIPTION: dual output switching power supply
Block Diagram
Static Characteristics
Output Derating
Dimensions (mm)
th
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
相关型号:
©2020 ICPDF网 联系我们和版权申明