SERIES: VF-D250-DXXA DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• up to 250 W continuous power w/ 16 CFM forced air  
• 600 W peak power within 500 µs duty duration  
• passive power correction  
• dual outputs  
• power good signal  
• remote on/off control  
• 3,000 Vac isolation voltage  
• over load, over voltage, over temperature, and short circuit protections  
• UL/cUL, and TUV 60950-1 safety approvals  
• efficiency up to 70%  
RoHS  
output  
voltage  
output  
current  
output  
power1  
ripple and  
noise  
efficiency  
MODEL  
3,4  
max w/  
max w/  
max  
(A)  
airflow2  
max  
(W)  
airflow2  
max  
(mVp-p)  
typ  
(%)  
(Vdc)  
(A)  
(W)  
3.3  
12  
12  
7
24  
12  
50  
120  
VF-D250-D312A  
VF-D250-D324A  
VF-D250-D512A  
VF-D250-D524A  
VF-D250-D548A  
VF-D250-D1224A  
100  
100  
100  
100  
100  
135  
200  
200  
200  
200  
200  
250  
70%  
70%  
70%  
70%  
70%  
70%  
3.3  
24  
12  
4
24  
6
50  
240  
5
12  
12  
7
24  
12  
50  
120  
5
24  
12  
4
24  
6
50  
240  
5
48  
12  
2
24  
3
50  
480  
12  
24  
7
4
12  
6
120  
240  
Notes:  
1. Maximum total combined power  
2. With external 16 CFM fan  
3. 10% minimum load is required to maintain the ripple and regulation.  
4. Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel.  
PART NUMBER KEY  
VF - D250 - DXX A - X X  
Base Number  
Output Voltage  
Low leakage option:  
“blank” = standard specification  
L = low leakage (contact factory)  
Input/Output connector:  
“blank” = Terminal block input / Terminal block output  
1 = Molex input / Molex output  
2 = Molex input / Terminal block output  
3 = Terminal block input / Molex output  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VF-D250-DXXA DESCRIPTION: AC-DC POWER SUPPLY  
date 03/29/2013 page 2 of 5  
INPUT  
parameter  
voltage  
conditions/description  
min  
90/180  
47  
typ  
max  
132/264  
63  
units  
Vac  
90-132/180-264 auto selectable  
frequency  
Hz  
at 110~120 Vac, cold start  
at 200~240 Vac, cold start  
6
3
A
A
current  
at 115 Vac, full load, cold start  
at 230 Vac, full load, cold start  
35  
70  
A
A
inrush current  
power factor  
remote on/off  
compliant to EN 61000-3-2 class A  
designated as RMSW on the CN1, requires a low signal to inhibit output, hiccup mode  
OUTPUT  
parameter  
conditions/description  
low line to high line  
all other outputs  
min  
typ  
±5  
max  
units  
%
line regulation  
load regulation  
temperature coefficient  
±5  
%
0.25  
mV/°C  
Output voltage returns to within 1% in less than 2.5 ms for a 50% load change.  
Peak transient does not exceed 5%.  
transient response  
start-up time  
rise time  
at 120 Vac  
1
s
0.2  
20  
20  
ms  
ms  
%
hold-up time  
adjustability  
at 120 Vac and 80% of rated maximim load  
±5  
Designated as PG on the CN1.  
This signal goes high 100-500 mS after the output reaches regulation.  
It goes low at least 1 mS before loss of regulation.  
power good  
fan drive  
12 Vdc / 400 mA for external fan  
PROTECTIONS  
parameter  
conditions/description  
over voltage protection  
over current protection  
short circuit protection  
over temperature protection  
AC input needs to be reset to restart the power supply  
130  
140  
%
%
automatically recovers  
110  
short circuit can be continuous, recovers automatically upon removal of short  
auto recovery  
85  
°C  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
applied for 3 seconds at 10 mA max.  
primary to secondary  
primary to transformer core  
primary to earth chassis  
3,000  
1,500  
1,500  
Vac  
Vac  
Vac  
isolation voltage  
safety approvals  
UL 60950-1, CSA C22.2 No. 60950-1, TUV EN 60950-1 and CB  
CISPR 22/EN 55022 class B, EN 61000-3-2, 3,  
EN 61000-4-2, 3, 4, 5, 6, 8, 11, EN 55024 CE marked (LVD)  
EMI/EMC  
at 240 Vac  
at 120 Vac  
500  
300  
μA  
μA  
leakage current  
RoHS compliant  
MTBF  
yes  
according to MIL-HDBK-217 at 30 ºC  
100,000  
hrs  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VF-D250-DXXA DESCRIPTION: AC-DC POWER SUPPLY  
date 03/29/2013 page 3 of 5  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
0
typ  
max  
50  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
storage humidity  
vibration  
-20  
5%  
5%  
5
85  
°C  
non-condensing  
90%  
95%  
50  
%
%
acceleration ± 7.35 M/(SxS), on X, Y and Z Axis  
Hz  
DERATING CURVES  
output power vs. ambient temperature  
100  
80  
60  
50  
40  
20  
-25  
0
10  
20  
30  
40  
50  
60  
70  
Ambient Temperature (°C)  
MECHANICAL  
parameter  
dimensions  
weight  
conditions/description  
min  
typ  
max  
units  
inches  
g
5(L) x 3.2(W) x 1.5(H)  
450  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VF-D250-DXXA DESCRIPTION: AC-DC POWER SUPPLY  
date 03/29/2013 page 4 of 5  
MECHANICAL DRAWING  
CN1  
1
2
3
ground  
ac neutral  
ac line  
CN3  
1
2
3
Power Good  
remote switch  
RTN  
OUTPUT  
INPUT  
CN2  
Vo2  
1
2
3
4
5
6
7
8
RTN  
RTN  
RTN  
RTN  
Vo1  
Vo1  
Vo1  
Notes:  
1. CN1 mates with molex part no. 09-91-0500 or equivalent and molex 2478, 2578, 8818 crimp pins.  
2. CN2 mates with molex part no. 09-91-0800 and molex 2478, 2578, 8818 crimp pins.  
3. CN3 mates with JST part no. XHP-3 or equivalent (CHYAO SHIUNN JS-2001-03) and JST SXH-002T-P0.6 mating pins  
4. Fan drive connector mates with JST part no. XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02).  
5. Mounting hole max depth 2.30mm  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VF-D250-DXXA DESCRIPTION: AC-DC POWER SUPPLY  
date 03/29/2013 page 5 of 5  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
new template applied  
V-Infinity branding removed  
updated spec  
05/05/2009  
12/17/2011  
08/28/2012  
03/29/2013  
1.01  
1.02  
1.03  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

VF-D250-D1224A-CF

over load, over voltage, over temperature, and short circuit protections
CUI

VF-D250-D312A

up to 250 W continuous power w/ 16 CFM forced air
CUI

VF-D250-D312A-CF

over load, over voltage, over temperature, and short circuit protections
CUI

VF-D250-D324A

up to 250 W continuous power w/ 16 CFM forced air
CUI

VF-D250-D324A-CF

over load, over voltage, over temperature, and short circuit protections
CUI

VF-D250-D512A

up to 250 W continuous power w/ 16 CFM forced air
CUI

VF-D250-D512A-CF

over load, over voltage, over temperature, and short circuit protections
CUI

VF-D250-D524A

up to 250 W continuous power w/ 16 CFM forced air
CUI

VF-D250-D524A-CF

over load, over voltage, over temperature, and short circuit protections
CUI

VF-D250-D548A

up to 250 W continuous power w/ 16 CFM forced air
CUI

VF-D250-D548A-CF

over load, over voltage, over temperature, and short circuit protections
CUI

VF-D250-DXXA

up to 250 W continuous power w/ 16 CFM forced air
CUI