VF-S250-XXA [CUI]
passive power factor correction;型号: | VF-S250-XXA |
厂家: | CUI INC |
描述: | passive power factor correction |
文件: | 总5页 (文件大小:221K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date 08/13/2013
page 1 of 5
SERIES: VF-S250-XXA │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 250 W continuous power
• 600 W peak power within 500 μs duty duration
• passive power factor correction
• power good signal
• remote on/off control
• 3000 Vac isolation voltage
• over load, over voltage, over temperature, and short circuit protections
• UL, cUL, and TUV 60950-1 safety approvals
• efficiency up to 85%
RoHS
output
voltage
output
current
max
output1
power
ripple and
noise
efficiency
MODEL
2,3
max
max
typ
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
VF-S250-05A
VF-S250-09A
VF-S250-12A
VF-S250-15A
VF-S250-18A
VF-S250-24A
VF-S250-28A
VF-S250-36A
VF-S250-48A
VF-S250-54A
40
200
225
250
250
250
250
250
250
250
250
50
75%
83%
80%
83%
83%
83%
83%
83%
83%
83%
9
25
90
12
15
18
24
28
36
48
54
20.83
16.67
13.89
10.42
8.93
6.93
5.21
4.63
120
150
180
240
280
360
480
540
Notes:
1. Maximum power must not exceed 135 W with convection cooling or 250 W for forced air. 5 and 9 V models maximum current listed.
2. 1% minimum load is required to maintain the ripple and regulation.
3. Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 ꢀF ceramic capacitor and a 22 ꢀF electrolytic capacitor in parallel.
PART NUMBER KEY
VF - S250 - XX A - X X
Base Number
Output Voltage
Low leakage option:
“blank” = standard specification
L = low leakage (contact factory)
Input/Output connector:
“blank” = Terminal block input / Terminal block output
1 = Molex input / Molex output
2 = Molex input / Terminal block output
3 = Terminal block input / Molex output
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2013 │ page 2 of 5
INPUT
parameter
voltage
conditions/description
min
90/180
47
typ
max
132/264
63
units
Vac
90-132/180-264 auto selectable
frequency
Hz
at 110~120 Vac, cold start
at 200~240 Vac, cold start
6
3
A
A
current
at 115 Vac, cold start
at 230 Vac, cold start
35
70
A
A
inrush current
power factor
remote on/off
compliant to EN 61000-3-2 class A
designated as RMSW on the CN1, requires a low signal to inhibit output, hiccup mode
OUTPUT
parameter
conditions/description
low line to high line
all other outputs
min
typ
±1
max
units
%
line regulation
load regulation
temperature coefficient
±1
%
0.25
mV/°C
output voltage returns to within 1% in less than 2.5 ms for a 50% load change
peak transient does not exceed 5%.
transient response
start-up time
rise time
at 120 Vac
1
s
0.2
20
20
ms
ms
%
hold-up time
adjustability
at 120 Vac and 80% of rated maximim load
±5
designated as PG on the CN1, signal goes high 100~500 ms after the output
reaches regulation, signal goes low at least 1 ms before loss of regulation
power good
fan drive
12 Vdc / 300 mA for external fan
PROTECTIONS
parameter
conditions/description
min
typ
max
130
140
units
%
over voltage protection
over current protection
short circuit protection
over temperature protection
AC input needs to be reset to restart the power supply
automatically recovers
110
%
short circuit can be continuous, recovers automatically upon removal of short
auto recovery
85
°C
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
for 3 seconds at 10 mA max
primary to secondary:
primary to transformer core:
primary to earth chassis:
3,000
1,500
1,500
Vac
Vac
Vac
isolation voltage
safety approvals
EMI/EMC
UL 60950-1, CSA C22.2 No. 60950-1, TUV EN 60950-1 and CB
CISPR 22/EN 55022 class B, EN 61000-3-2, 3,
EN 61000-4-2, 3, 4, 5, 6, 8, 11, EN 55024 CE marked (LVD)
at 240 Vac, (optional for 500 ꢀA at 240 Vac,
300 ꢀA at 120 Vac)
leakage current
1.5
mA
hrs
MTBF
according to MIL-HDBK-217 at 30ºC
yes
100,000
RoHS compliant
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2013 │ page 3 of 5
ENVIRONMENTAL
parameter
conditions/description
min
0
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
vibration
-20
5%
5%
5
85
°C
non-condensing
90%
95%
50
%
non-condensing
%
acceleration ±7.35 M/(SxS), on X, Y and Z Axis
Hz
DERATING CURVE
output power vs. ambient temperature
100
80
60
50
40
20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2013 │ page 4 of 5
MECHANICAL
parameter
dimensions
weight
conditions/description
min
typ
max
units
mm
g
127.00 x 81.28 x 38.10 (5 x 3.2 x 1.5 inch)
400
MECHANICAL DRAWING
50.80 2.000
6.35 0.250
6.35 0.250
19.05 0.750
13.90 0.547
(2 PLCS)
68.58 2.700
(2 PLCS)
44.52 1.753
(2 PLCS)
mounting hole
M3x0.5 (7 PLCS)
LED
81.28 3.200
FAN
64.76 2.550
RTN
CN1
CN3
CN2
RMSW
P.G
1
2
3
ground
ac neutral
ac line
VO-
FG
NEUTRAL
LINE
VO+
CN1
CN2
Vo+
Vo+
Vo+
Vo-
1
2
3
4
5
6
molex part no.
molex part no.
26-48-1061
(6 pins)
8.26 0.325
26-48-1051
(5 pins, 3 used)
terminal block
terminal block
M3 screw
M3 screw
3pins 6.35mm center
4pins 6.35mm center
Vo-
Vo-
CN3
1
2
3
Power Good
remote switch
RTN
38.10 1.500
127.00 5.000
Notes:
1. CN1 mates with molex part no. 09-93-0500 and molex 2478, 2578, 8818 crimp pins.
2. CN2 mates with molex part no. 09-93-0600 and molex 2478, 2578, 8818 crimp pins.
3. CN3 mates with JST part no. XHP-3 or equivalent (Chyao Shiunn JS-2001-03) and JST SXH-002T-P0.6 mating pins
4. Fan drive connector mates with JST part no. XHP-2 or equivalent.
5. Mounting hole maximum M3 screw depth 3.8mm
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/13/2013 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
new template applied
05/5/2009
12/16/2011
08/28/2012
07/11/2013
08/13/2013
1.01
1.02
1.03
1.04
V-Infinity branding removed
updated Molex mating connector part numbers
updated spec
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明