VFSD1-S3.3-S3.3-SIP_12 [CUI]
DC-DC CONVERTER; DC-DC变换器型号: | VFSD1-S3.3-S3.3-SIP_12 |
厂家: | CUI INC |
描述: | DC-DC CONVERTER |
文件: | 总5页 (文件大小:241K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
date 01/27/2012
page 1 of 5
SERIES: VFSD1-SIP Series │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• 1 W isolated output
• industry standard pinout
• unregulated
• single output (3.3~24 V)
• small footprint
• 3,000 V isolation
• short circuit protection
• temperature range (-40~85°C)
• high efficiency to 83%
RoHS
input
voltage
range
(Vdc)
output
voltage
output
current
output
power
max
(W)
ripple
noise
max
efficiency
UL60950
MODEL
min
max
typ
(%)
(Vdc)
3.3
5
(mA)
31
20
30
20
12
9
(mA)
(mVp-p)
VFSD1-S3.3-S3.3-SIP
VFSD1-S3.3-S5-SIP
VFSD1-S5-S3.3-SIP
VFSD1-S5-S5-SIP
VFSD1-S5-S9-SIP
VFSD1-S5-S12-SIP
VFSD1-S5-S15-SIP
VFSD1-S5-S24-SIP
VFSD1-S12-S5-SIP
VFSD1-S12-S9-SIP
VFSD1-S12-S12-SIP
VFSD1-S12-S15-SIP
VFSD1-S12-S24-SIP
VFSD1-S24-S3.3-SIP
VFSD1-S24-S5-SIP
VFSD1-S24-S9-SIP
VFSD1-S24-S12-SIP
3 ~ 3.6
303
200
303
200
111
83
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
100
100
100
100
100
100
100
150
100
100
100
100
150
100
100
100
100
69
74
73
72
76
79
78
79
70
75
78
79
79
70
71
76
78
NO
NO
3.3 ~ 3.6
4.5 ~ 5.5
3.3
5
NO
4.5 ~ 5.5
YES
YES
YES
YES
NO
4.5 ~ 5.5
9
4.5 ~ 5.5
12
15
24
5
4.5 ~ 5.5
7
67
10.8 ~ 13.2
10.8 ~ 13.2
10.8 ~ 13.2
10.8 ~ 13.2
10.8 ~ 13.2
10.8 ~ 13.2
21.6 ~ 26.4
21.6 ~ 26.4
21.6 ~ 26.4
21.6 ~ 26.4
5
42
20
12
9
200
111
83
YES
YES
YES
YES
NO
9
12
15
24
3.3
5
7
67
5
42
31
20
12
9
303
200
111
83
NO
YES
YES
YES
9
12
VFSD1-S24-S15-SIP
VFSD1-S24-S15-SIP-A
VFSD1-S24-S24-SIP
21.6 ~ 26.4
21.6 ~ 26.4
21.6 ~ 26.4
15
15
24
7
7
5
67
67
42
1
1
1
100
150
150
80
83
77
YES
NO
NO
Note:
1. Ripple and noise measured at 20 mHz BW
cui.com
CUI Inc │ SERIES: VFSD1-SIP Series │ DESCRIPTION: DC-DC CONVERTER
date 01/27/2012 │ page 2 of 5
INPUT
parameter
conditions/description
min
typ
max
units
3
4.5
10.8
13.5
21.6
3.3
5
12
15
24
3.6
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
Vdc
operating input voltage
OUTPUT
parameter
conditions/description
min
typ
max
units
3.3 V output
all other models
±1.5
±1.2
%
%
line regulation
load regulation
For Vin change of 1%, full load
10% to 100% full load,
nominal line
VFSD1-S24-S15-SIP-A
all other models
2
±10
3
±15
%
%
voltage accuracy
See tolerance envelope graph
100% load, input voltage range
±1
±3
%
switching frequency
Temperature coefficient
100
kHz
0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
max
units
short circuit protection
Supply voltage must be discontinued at end of
short circuit duration
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
units
Vdc
MΩ
isolation voltage
isolation resistance
isolation capacitance
RoHS compliant
MTBF
tested for 1 minute at 1 mA max.
3,000
1,000
at 500 Vdc
input to output, 100 kHz / 1 V
yes
1,000
pF
3,500,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
max
85
units
°C
case operating temperature
storage temperature
storage humidity
125
95
°C
non-condensing
%
temperature rise
100% load
15
25
°C
lead temperature
1.5 mm from the case for 10 seconds
300
°C
Note:
1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified.
cui.com
CUI Inc │ SERIES: VFSD1-SIP Series │ DESCRIPTION: DC-DC CONVERTER
date 01/27/2012 │ page 3 of 5
DERATING CURVES
100
80
60
40
20
-40
-20
0
20
40
60
85
105 120
Ambient Temperature (°C)
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
0.77 x 0.24 x 0.39 inch (19.6 x 6.0 x 10.0 mm)
Plastic (UL94-V0)
case material
weight
2.1
g
MECHANICAL DRAWING
units: mm
All pins on a 2.54mm pitch
All pin diameters are 0.50mm
Recommended Footprint
19.60
2.54
2.54
1 2
5 7
10.00
4.10
PIN CONNECTIONS
1
2
5
7
+Vin
-Vin
-Vout
+Vout
1.25
2.00
6.00
1 2
5
7
15.24
BOTTOM VIEW
cui.com
CUI Inc │ SERIES: VFSD1-SIP Series │ DESCRIPTION: DC-DC CONVERTER
date 01/27/2012 │ page 4 of 5
APPLICATION NOTES
1. Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum output load could not be less than 10% of
the full load. If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to
increase the load, or use our company’s products with a lower rated output power (E_S-W25&F_S-W25).
2. Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against overload. The simplest method is to
connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
3. Recommended testing and application circuit
If you want to further decrease the input/output ripple, an “LC” filtering network may be connected to the input and output ends
of the DC/DC converter, see (Figure 1). It should also be noted that the inductance and the frequency of the “LC” filtering network
should be staggered with the DC/DC frequency to avoid mutual interference. However, the capacitance of the output filter capacitor
must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and
reliable operation is ensured, the recommended capacitance of its filter capacitor sees (Table 1).
External Capacitor Table (Table 1)
Figure 1
Vin
(Vdc)
Cin
(μF)
Single Vout
(Vdc)
Cout
(ꢀF)
Dual Vout Cout
(Vdc)
(ꢀF)
3.3, 5
12
4.7
2.2
2.2
1.0
3.3, 5
9.0
10
4.7
2.2
1.0
±5
4.7
±9
2.2
15
12
±12
±15
1.0
24
15, 24
0.47
4. Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (Figure 2).
Figure 2
5. No parallel connection or plug and play
cui.com
CUI Inc │ SERIES: VFSD1-SIP Series │ DESCRIPTION: DC-DC CONVERTER
date 01/27/2012 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
10/04/2007
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明