SERIES: VGS-100W DESCRIPTION: INTERNAL AC-DC POWER SUPPLY  
FEATURES  
• wide input range (85 ~ 305 VAC)  
• available with conformal coating or terminal cover options  
• UL/EN/IEC 62368 certified  
• designed to meet IEC/EN 61558 and IEC/EN 60335 system requirements  
• short-circuit, over-current, over-voltage protections  
• CISPR/EN55032 Class B radiated/conducted emissions  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efficiency²  
MODEL  
and noise1  
typ  
typ  
(Vdc)  
5
(A)  
(W)  
(mVp-p)  
(%)  
VGS-100W-5  
VGS-100W-12  
VGS-100W-15  
VGS-100W-24  
VGS-100W-36  
VGS-100W-48  
18.0  
8.5  
7.0  
4.5  
2.8  
2.3  
90  
100  
120  
120  
150  
200  
200  
85.5  
87.0  
87.0  
89.5  
89.5  
90.5  
12  
15  
24  
36  
48  
102  
105  
108  
100  
110  
Notes:  
1. Ripple & noiswe are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.  
2. Measured at 230 Vac.  
PART NUMBER KEY  
VGS-100W-XX-X  
Base Number  
Output Voltage  
A - with terminal cover  
B - with conformal coating  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100W DESCRIPTION: AC-DC POWER SUPPLY  
date 06/04/2021 page 2 of 5  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
ac input  
dc input  
85  
120  
305  
431  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 115 Vac  
at 230 Vac  
3
1.5  
A
A
inrush current  
at 115 Vac, cold start  
at 230 Vac, cold start  
35  
65  
A
A
leakage current  
at 277 Vac  
0.75  
mA  
no load power consumption  
at 230 Vac, 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc output  
at 230 Vac, 36 Vdc, 48 Vdc output  
0.3  
0.5  
W
W
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
5 Vdc output  
12 Vdc output  
15 Vdc output  
24 Vdc output  
36 Vdc output  
48 Vdc output  
10,000  
6,800  
3,300  
2,200  
1,000  
470  
μF  
μF  
μF  
μF  
μF  
μF  
capacitive load  
line regulation  
load regulation  
hold-up time  
rated load  
±0.5  
%
0% ~ 100%, 5 Vdc output  
0% ~ 100%, other outputs  
±1  
±0.5  
%
%
at 115 Vac  
at 230 Vac  
10  
55  
ms  
ms  
switching frequency  
temperature coefficient  
adjustability  
65  
kHz  
%/°C  
%
±0.03  
±10  
built in trim pot  
5 Vdc output  
other outputs  
±2  
±1  
%
%
initial set point accuracy  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
5 Vdc output, clamp, auto recovery  
12 Vdc output, clamp, auto recovery  
15 Vdc output, clamp, auto recovery  
24 Vdc output, clamp, auto recovery  
36 Vdc output, clamp, auto recovery  
48 Vdc output, clamp, auto recovery  
7.5  
19.2  
24  
38.4  
57.6  
60  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
over voltage protection  
over current protection  
short circuit protection  
auto recovery  
110  
160  
%
continuous, hiccup, auto recovery  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to ground, 1 min. <10mA  
input to output, 1 min. <10mA  
output to ground, 1 min. <10mA  
2,000  
4,000  
1,250  
Vac  
Vac  
Vac  
isolation voltage  
safety approvals  
certified to  
62368: IEC, EN, UL  
designed to meet 60335: IEC, EN  
designed to meet 61558: IEC, EN  
safety class  
EMI/EMC  
class I  
CISPR 32/EN 55032 Class B, IEC 61000-3-2 Class A  
ESD  
IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV perf. criteria A  
IEC/EN 61000-4-3 10 V/m perf. criteria A  
radiated immunity  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100W DESCRIPTION: AC-DC POWER SUPPLY  
date 06/04/2021 page 3 of 5  
SAFETY & COMPLIANCE  
EFT/burst  
IEC/EN 61000-4-4 ±2KV perf. criteria A  
surge  
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV perf. criteria A  
IEC/EN 61000-4-6 10 Vr.m.s perf. criteria A  
conducted immunity  
voltage dips and interruption  
IEC/EN 61000-4-11 0%, 70% perf. criteria B  
MTBF  
RoHS  
as per MIL-HDBK-217F at 25°C  
yes  
300,000  
hours  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-30  
-40  
20  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
storage humidity  
85  
°C  
non-condensing  
non-condensing  
90  
%
10  
95  
%
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
dimensions  
129.00 x 97.00 x 30.00 mm  
mm  
5 Vdc output  
other outputs  
325  
305  
g
g
weight  
cooling  
free air convection  
case material  
Metal (AL1100, SGCC)  
MECHANICAL DRAWING  
units: mm  
tolerance: ±1 [±0.039]  
PIN CONNECTIONS  
PIN  
1
Function  
AC(L)  
2
AC(N)  
3
4
-Vo  
-Vo  
Screw  
spec.  
Torque  
(max)  
5
Position  
2 - 4  
7 - 8  
L (max)  
5 mm  
6
+Vo  
+Vo  
M3  
M3  
0.4N·m  
7
3 mm  
0.4N·m  
Note: At least one hole position, 1 ~ 9, must be  
securely connected to Protective Earth (PE)  
wire range: 22-12 AWG  
connector tightening torque: M3.5, 0.8 N·m  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100W DESCRIPTION: AC-DC POWER SUPPLY  
date 06/04/2021 page 4 of 5  
DERATING CURVE  
EFFICIENCY CURVES  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VGS-100W DESCRIPTION: AC-DC POWER SUPPLY  
date 06/04/2021 page 5 of 5  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
09/02/2020  
06/04/2021  
1.01  
derating and efficiency curves updated  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

VGS-150B

AC-DC POWER SUPPLY
CUI

VGS-150B-12

AC-DC POWER SUPPLY
CUI

VGS-150B-24

AC-DC POWER SUPPLY
CUI

VGS-150B-48

AC-DC POWER SUPPLY
CUI

VGS-150W

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-150W-12

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-150W-15

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-150W-24

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-150W-36

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-150W-48

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-200B

AC-DC POWER SUPPLY
CUI

VGS-200B-12

AC-DC POWER SUPPLY
CUI