SERIES: VGS-350C │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
• selectable input range (90 ~ 132 Vac / 180 ~ 264 Vac)
• UL/EN/IEC 62368 certified
• designed to meet IEC/EN 60335, and GB4943 system requirements
• short-circuit, over-current, over-voltage, over-temperature protections
• integrated cooling fan
• output adjustable via trimpot +/- 10%
output
voltage
output
current
max
output
power
max
ripple
efficiency2
MODEL
and noise1
typ
typ
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
VGS-350C-5
VGS-350C-12
VGS-350C-15
VGS-350C-24
VGS-350C-36
VGS-350C-48
60.0
29.0
23.2
14.6
9.7
300.0
348.0
348.0
350.4
349.2
350.4
150
150
150
150
200
200
84
85
87
88
88
89
12
15
24
36
48
7.3
Notes:
1. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
2. Measured at 230 Vac
PART NUMBER KEY
VGS-350C - XX - X
Output Voltage
Base Number
A - with terminal cover
B - with conformal coating
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-350C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2020 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
ac input (low voltage, switch at 115V)
ac input (high voltage, switch at 230V)
dc input (switch at 230V)
90
180
240
132
264
373
Vac
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac
at 230 Vac
8
4
A
A
at 115 Vac, cold start
at 230 Vac, cold start
60
60
A
A
inrush current
leakage current
at 240 Vac
0.75
0.75
mA
W
no load power consumption
at 230 Vac, 25°C
OUTPUT
parameter
conditions/description
min
typ
max
units
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
36 Vdc output
48 Vdc output
10,000
4,000
3,300
1,500
1,500
470
μF
μF
μF
μF
μF
μF
capacitive load
5 Vdc output, full load
12 Vdc ouput, full load
other outputs, full load
±3
±1.5
±1
%
%
%
initial set point accuracy
line regulation
±0.5
%
5 Vdc output, 0%~100% load
12 Vdc ouput, 0%~100% load
other outputs, 0%~100% load
±2
±1
±0.5
%
%
%
load regulation
adjustability
hold-up time
built in trim pot
±10
%
at 115 Vac
at 230 Vac
12
16
ms
ms
switching frequency
65
kHz
temperature coefficient
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
units
5 Vdc output, hiccup, auto-recovery
12 Vdc output, hiccup, auto-recovery
15 Vdc output, hiccup, auto-recovery
24 Vdc output, hiccup, auto-recovery
36 Vdc output, hiccup, auto-recovery
48 Vdc output, hiccup, auto-recovery
5.75
13.8
18.0
28.8
41.4
55.2
6.75
16.2
21.0
33.6
46.8
59.5
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
over voltage protection
over current protection
short circuit protection
auto-recovery
110
180
%
hiccup, continuous, auto-recovery
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to ground
input to output
output to ground
2,000
3,000
500
Vac
Vac
Vac
isolation voltage
certified to:
62368: IEC/EN/UL
designed to meet: 60335: IEC/EN
designed to meet: 61558: IEC/EN
designed to meet: 4943: GB
safety approvals
safety class
Class I
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-350C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2020 │ page 3 of 6
SAFETY & COMPLIANCE
EMI/EMC
CISPR32/EN55032 Class A
ESD
IEC/EN 61000-4-2 Contact ±6KV /Air ±8KV, perf. Criteria A
IEC/EN 61000-4-3 10V/m, perf. Criteria A
radiated immunity
EFT/burst
IEC/EN 61000-4-4 ±2KV, perf. Criteria A
surge
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV, perf. Criteria A
IEC/EN61000-4-6 10 Vr.m.s, perf. Criteria A
conducted immunity
voltage dips and interruptions
IEC/EN61000-4-11 0%, 70%, perf. Criteria B
MTBF
RoHS
as per MIL-HDBK-217F at 25°C
yes
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
-30
-40
20
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
85
°C
non-condensing
non-condensing
90
%
0
95
%
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-350C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2020 │ page 4 of 6
MECHANICAL
parameter
dimensions
weight
conditions/description
min
typ
max
units
mm
g
215.00 x 115.00 x 30.00
700
cooling
forced air cooling
case material
metal (AL1100, SGCC)
MECHANICAL DRAWING
units: mm [inch]
tolerance: ±1.0 [±0.039]
wire range: 22-12 AWG
connector tightening torque: M3.5, 0.8 N·m
PIN CONNECTIONS
PIN
1
Function
+Vo
+Vo
+Vo
-Vo
2
3
4
5
-Vo
6
-Vo
7
8
AC(N)
AC(L)
9
Position
Screw
spec.
L (max)
Torque
(max)
ac input
(Vac)
dc input
(Vdc)
Switch
1 - 4
5 - 8
M4
5 mm
3 mm
0.9 N·m
90~132
-
M4
0.9 N·m
Note: At least one hole position, 1 ~ 8 , must be securely connected
to Protective Earth (PE)
180~264
240~373
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-350C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2020 │ page 5 of 6
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-350C │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2020 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
12/10/2020
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
VGS-350C-48
INTERNAL AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-350C-5
INTERNAL AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-35B
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-35B-12
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-35B-24
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-35B-48
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-50
SWITCHING POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-50-12
SWITCHING POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-50-15
SWITCHING POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-50-24
SWITCHING POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-50-33
SWITCHING POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VGS-50-48
SWITCHING POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
©2020 ICPDF网 联系我们和版权申明