VGS-50C-36 [CUI]
INTERNAL AC-DC POWER SUPPLY;型号: | VGS-50C-36 |
厂家: | CUI INC |
描述: | INTERNAL AC-DC POWER SUPPLY |
文件: | 总5页 (文件大小:727K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
date 09/28/2020
page 1 of 5
SERIES: VGS-50C │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
• universal input range (85 ~ 264 VAC)
• UL/EN/IEC 62368 certified
• designed to meet IEC/EN 61558, IEC/EN 60335, and GB 4943 system requirements
• short-circuit, over-current, over-voltage protections
• CISPR/EN55032 Class B radiated/conducted emissions
• output adjustable via trimpot +/- 10%
output
voltage
output
current
max
output
power
max
ripple
efficiency2
MODEL
and noise1
typ
typ
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
VGS-50C-5
VGS-50C-12
VGS-50C-15
VGS-50C-24
VGS-50C-36
VGS-50C-48
10.0
4.2
50.0
50.4
51.0
52.8
52.2
52.8
80
86
87
88
89
89
90
12
15
24
36
48
120
120
150
200
200
3.4
2.2
1.45
1.1
Notes:
1. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
2. Measured at 230 Vac
PART NUMBER KEY
VGS-50C - XX - X
A - with terminal cover
B - with conformal coating
Output Voltage
Base Number
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-50C │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/28/2020 │ page 2 of 5
INPUT
parameter
conditions/description
min
typ
max
units
ac input
dc input
85
120
264
373
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac
at 230 Vac
1.2
0.8
A
A
at 115 Vac, cold start
at 230 Vac, cold start
30
50
A
A
inrush current
leakage current
at 240 Vac
0.75
0.3
mA
W
no load power consumption
OUTPUT
parameter
conditions/description
min
typ
max
units
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
36 Vdc output
48 Vdc output
8,500
2,000
1,500
1,000
800
μF
μF
μF
μF
μF
μF
capacitive load
680
5 Vdc output, full load
other outputs, full load
±2
±1
%
%
initial set point accuracy
line regulation
±0.5
%
0%~100% load
5 Vdc output
other outputs
load regulation
±1
±0.5
%
%
adjustability
hold-up time
built in trim pot
±10
%
at 115 Vac
at 230 Vac
8
30
ms
ms
switching frequency
65
kHz
temperature coefficient
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
units
5 Vdc output, clamp
12 Vdc output, clamp
15 Vdc output, clamp
24 Vdc output, clamp
36 Vdc output, clamp
48 Vdc output, clamp
6.3
16.2
21.75
33.6
48.6
60.0
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
over voltage protection
over current protection
short circuit protection
auto-recovery
110
200
%
hiccup, continuous, auto-recovery
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to ground
input to output
output to ground
2,000
4,000
1,250
Vac
Vac
Vac
isolation voltage
safety approvals
certified to:
62368: IEC/EN/UL
designed to meet: 60335: IEC/EN
designed to meet: 61558: IEC/EN
designed to meet: 4943: GB
safety class
EMI/EMC
ESD
Class I
CISPR32/EN55032 Class B, IEC/EN61000-3-2 Class A
IEC/EN 61000-4-2 Contact ±6KV /Air ±8KV, perf. Criteria A
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-50C │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/28/2020 │ page 3 of 5
SAFETY & COMPLIANCE
radiated immunity
IEC/EN 61000-4-3 10V/m, perf. Criteria A
IEC/EN 61000-4-4 ±2KV, perf. Criteria A
EFT/burst
surge
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV, perf. Criteria A
IEC/EN61000-4-6 10 Vr.m.s, perf. Criteria A
conducted immunity
voltage dips and interruptions
IEC/EN61000-4-11 0%, 70%, perf. Criteria B
MTBF
RoHS
as per MIL-HDBK-217F at 25°C
yes
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
-30
-40
20
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
85
°C
non-condensing
non-condensing
90
%
0
95
%
MECHANICAL
parameter
dimensions
weight
conditions/description
min
typ
max
units
mm
g
99.00 x 82.00 x 30.00
180
cooling
natural convection
case material
metal (AL1100, SGCC)
MECHANICAL DRAWING
units: mm [inch]
tolerance: ±1.0 [±0.039]
wire range: 22-12 AWG
connector tightening torque: M3.5, 0.8 N·m
PIN CONNECTIONS
PIN
1
Function
AC(L)
2
AC(N)
3
4
-Vo
5
+Vo
Position
Screw
spec.
L (max)
Torque
(max)
2 - 3
6 - 7
M3
5 mm
3 mm
0.4 N·m
M3
0.4 N·m
Note: At least one hole position, 1 ~ 8, must be securely connected
to Protective Earth (PE)
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-50C │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/28/2020 │ page 4 of 5
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-50C │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/28/2020 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
09/28/2020
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明