SERIES: VHB150R DESCRIPTION: DC-DC CONVERTER  
FEATURES  
• up to 150 W isolated output  
• industry standard half brick package  
• 3:1 input range (66~160 V)  
• single output from 5~24 V  
• 1,500 V isolation  
• over current, over temperature, over voltage,  
and short circuit protections  
• remote on/off  
• efficiency up to 92.5%  
input  
voltage  
range  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efficiency  
MODEL  
and noise1  
max  
typ  
(Vdc)  
(Vdc)  
5
(A)  
(W)  
(mVp-p)  
(%)  
VHB150R-T110-S5  
VHB150R-T110-S12  
VHB150R-T110-S24  
66 ~ 160  
66 ~ 160  
66 ~ 160  
30  
12.5  
6.5  
150  
150  
150  
100  
150  
240  
92.5  
92.5  
92  
12  
24  
Notes:  
1. ripple and noise are measured at 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output  
PART NUMBER KEY  
VHB150R-T110 - SXX  
Base Number  
Input Voltage  
Output Voltage  
cui.com  
CUI Inc SERIES: VHB150R DESCRIPTION: DC-DC CONVERTER  
date 01/29/2013 page 2 of 4  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
160  
180  
units  
Vdc  
operating input voltage  
input surge voltage  
66  
110  
100 ms max.  
Vdc  
power up  
power down  
62  
56  
Vdc  
Vdc  
under voltage lockout  
positive logic remote on/off1  
filter  
PI type  
Notes:  
1. logic compatibility, open collector ref to -input  
Module ON, >3.5 ~ 75 Vdc or open circuit  
Module OFF, <1.8 Vdc  
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
±0.2  
±0.2  
units  
%
line regulation  
load regulation  
start-up time  
voltage accuracy  
measured from high line to low line  
measured from full load to zero load  
%
45  
ms  
%
±1.5  
error band  
25% step load change  
recover time  
±5  
200  
% Vout  
µs  
transient response  
adjustability2  
±10  
200  
%
switching frequency  
temperature coefficient  
100% load, input voltage range  
kHz  
±0.03  
%/°C  
Notes:  
2. trim-up: connect a resistor between the trim pin and -Sense  
trim-down: connect a resistor between the trim pin and +Sense  
PROTECTIONS  
parameter  
conditions/description  
%Vo  
min  
typ  
max  
units  
over voltage protection  
short circuit protection  
current limit  
115  
140  
%
continuous  
% nominal output current  
110  
180  
%
thermal shutdown case temp.  
105  
°C  
SAFETY AND COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to output  
input to case  
output to case  
2,250  
2,250  
1,500  
Vdc  
Vdc  
Vdc  
isolation voltage  
isolation resistance  
isolation capacitance  
safety approvals  
EMI/EMC  
10  
MΩ  
1,000  
pF  
UL 60950-1  
EN 50155 (EN 50121-3-2) with external filter  
RoHS compliant  
yes  
cui.com  
CUI Inc SERIES: VHB150R DESCRIPTION: DC-DC CONVERTER  
date 01/29/2013 page 3 of 4  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-55  
typ  
max  
100  
105  
95  
units  
°C  
case operating temperature  
storage temperature  
humidity  
°C  
non-condensing  
%
MECHANICAL  
parameter  
dimensions  
conditions/description  
min  
typ  
max  
units  
2.28 x 2.40 x 0.5 (57.9 x 61.0 x 12.7 mm)  
aluminum baseplate with plastic case  
inch  
case material  
weight  
90  
g
MECHANICAL DRAWING  
units: inches [mm]  
tolerance: x.xx ± 0.2inches [±0.5mm]  
x.xxx ± 0.1inches [±0.25mm]  
0.18 min  
[4.6]  
0.50  
Mounting Inserts  
M3*0.5 Through 4pl.  
[12.7]  
BOTTOM VIEW  
PIN CONNECTIONS  
PIN FUNCTION  
4
5
1
2
3
4
5
6
7
8
9
+Vin  
On/Off  
CASE  
-Vin  
-Vo  
3
6
7
8
2
1
-S  
TRIM  
+S  
9
+Vo  
1.900  
[48.30]  
2.28  
[57.9]  
cui.com  
CUI Inc SERIES: VHB150R DESCRIPTION: DC-DC CONVERTER  
date 01/29/2013 page 4 of 4  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
06/20/2012  
11/13/2012  
01/29/2013  
1.01  
1.02  
misc. updates, added product photo  
updated input voltage range  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

VHB150W

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q24-S12

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q24-S15

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q24-S24

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q24-S3R3

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q24-S5

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q48-S12

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q48-S15

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q48-S24

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q48-S3R3

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB150W-Q48-S5

half-brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHB200W

half brick dc-dc converter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI