VHE100W-Q48-S3R3 [CUI]

CONVERTER DC/DC 3.3V 25A 100W;
VHE100W-Q48-S3R3
型号: VHE100W-Q48-S3R3
厂家: CUI INC    CUI INC
描述:

CONVERTER DC/DC 3.3V 25A 100W

文件: 总4页 (文件大小:186K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
date 02/14/2013  
page 1 of 4  
SERIES: VHE100W DESCRIPTION: DC-DC CONVERTER  
FEATURES  
• up to 100 W isolated output  
• industry standard half brick package  
• 4:1 input range (9~36 V, 18~75 V)  
• single output from 3.3~48 V  
• 1,500 V isolation  
• tantalum free capacitors used  
• over current, over temperature, over voltage,  
and short circuit protections  
• remote on/off  
• very high efficiency up to 93%  
RoHS  
input  
voltage  
range  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple and  
efficiency  
MODEL  
noise1  
max  
typ  
(Vdc)  
(Vdc)  
3.3  
5
(A)  
(W)  
(mVp-p)  
(%)  
VHE100W-Q24-S3R3  
VHE100W-Q24-S5  
VHE100W-Q24-S12  
VHE100W-Q24-S15  
VHE100W-Q24-S24  
VHE100W-Q24-S48  
VHE100W-Q48-S3R3  
VHE100W-Q48-S5  
VHE100W-Q48-S12  
VHE100W-Q48-S15  
VHE100W-Q48-S24  
VHE100W-Q48-S48  
9 ~ 36  
9 ~ 36  
25  
20  
82.5  
100  
100  
100  
100  
100  
82.5  
100  
100  
100  
100  
100  
100  
100  
120  
120  
240  
480  
100  
100  
120  
120  
240  
480  
87  
89.5  
90.5  
90.5  
89  
9 ~ 36  
12  
15  
24  
48  
3.3  
5
8.4  
6.7  
4.2  
2.1  
25  
9 ~ 36  
9 ~ 36  
9 ~ 36  
88.5  
88  
18 ~ 75  
18 ~ 75  
18 ~ 75  
18 ~ 75  
18 ~ 75  
18 ~ 75  
20  
92  
12  
15  
24  
48  
8.4  
6.7  
4.2  
2.1  
93  
92.5  
91  
90.5  
Notes:  
1. ripple and noise are measured at 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output  
PART NUMBER KEY  
VHE100W - QXX - SXXX X  
Remote On/Off Control  
"blank" = positive logic  
N = negative logic  
Base Number  
Input Voltage  
Output Voltage  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: VHE100W DESCRIPTION: DC-DC CONVERTER  
date 02/14/2013 page 2 of 4  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
24 V input  
48 V input  
9
18  
24  
48  
36  
75  
Vdc  
Vdc  
operating input voltage  
surge voltage  
24 V input  
100 ms max.  
50  
100  
Vdc  
Vdc  
48 V input  
24 V input  
power up  
8.8  
17  
8
Vdc  
Vdc  
Vdc  
Vdc  
48 V input  
under voltage lockout  
24 V input  
power down  
48 V input  
16  
positive logic remote on/off1  
filter  
PI type  
Notes:  
1. logic compatibility, open collector ref to -input  
Module ON, 3.5 ~ 75 Vdc or open circuit  
Module OFF, <1.2 Vdc  
2. negative logic remote on/off available  
Module ON, <1.2 Vdc current limit, 110~165% nominal output  
Module OFF, 3.5 ~ 75 Vdc or open circuit  
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
±0.2  
±0.2  
±1.5  
500  
units  
%
line regulation  
measured from high line to low line  
measured from full load to zero load  
load regulation  
voltage accuracy  
transient response  
adjustability  
%
%
25% step load change  
µs  
±10  
250  
%
switching frequency  
temperature coefficient  
100% load, input voltage range  
kHz  
%/°C  
±0.03  
PROTECTIONS  
parameter  
conditions/description  
%Vo  
min  
typ  
max  
units  
over voltage protection  
short circuit protection  
current limit  
115  
140  
%
continuous  
% nominal output current  
110  
140  
%
thermal shutdown case temp.  
105  
°C  
SAFETY AND COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to output  
input to case  
output to case  
1,500  
1,500  
1,500  
Vdc  
Vdc  
Vdc  
isolation voltage  
isolation resistance  
isolation capacitance  
safety approvals  
RoHS compliant  
MTBF  
10  
MΩ  
1,000  
TBD  
typ  
pF  
UL 60950-1, CE  
yes  
MIL-STD-217F, GB, 25°C, full load  
hours  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-55  
max  
105  
105  
95  
units  
°C  
case operating temperature  
storage temperature  
humidity  
°C  
non-condensing  
%
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: VHE100W DESCRIPTION: DC-DC CONVERTER  
date 02/14/2013 page 3 of 4  
DERATING CURVE  
100  
80  
60  
with heatsink  
40  
20  
-40  
-20  
0
20  
40  
60  
80  
105 120  
Ambient Temperature (°C)  
MECHANICAL  
parameter  
dimensions  
conditions/description  
min  
typ  
max  
units  
2.28 x 2.40 x 0.50 (57.9 x 61.0 x 12.7 mm)  
aluminum  
inch  
case material  
weight  
95  
g
MECHANICAL DRAWING  
units: inches[mm]  
TOLERANCE:  
inches: X.XX = ±0.02  
X.XXX = ±0.010  
mm: X.XX = ±0.5  
X.XXX = ±0.25  
0.10 min  
[2.5]  
Mounting Inserts  
M3*0.5 Through 4pl.  
0.50  
[12.7]  
Bottom View  
4
3
5
PIN CONNECTIONS  
PIN FUNCTION  
6
7
8
1
2
3
4
5
6
7
8
9
+Vin  
On/Off  
CASE  
-Vin  
-Vo  
2
1
9
-S  
0.48  
[12.3]  
1.90  
TRIM  
+S  
[48.2]  
2.28  
[57.9]  
+Vo  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: VHE100W DESCRIPTION: DC-DC CONVERTER  
date 02/14/2013 page 4 of 4  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
08/22/2012  
02/14/2013  
1.01  
added negative logic option to part number key  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

VHE100W-Q48-S48

CONVERTER DC/DC 48V 2.1A 100W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHE100W-Q48-S5

CONVERTER DC/DC 5V 20A 100W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VHE1401

Fast Rectifier (100-500ns)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VHE1402

Fast Rectifier (100-500ns)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VHE1403

12 AMP SUPER EFFICIENT RECTIFIERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VHE1404

ULTRA FAST RECOVERY RECTIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICROSEMI

VHE1405

Rectifier Diode, 1 Phase, 1 Element, 10A, 300V V(RRM), Silicon, TO-220, 2 PIN

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICROSEMI

VHE1406

Rectifier Diode, 1 Phase, 1 Element, 10A, 400V V(RRM), Silicon, TO-220, 2 PIN

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICROSEMI

VHE205

ULTRA FAST RECOVERY RECTIFIERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICROSEMI

VHE210

Fast Rectifier (100-500ns)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VHE215

ULTRA FAST RECOVERY RECTIFIERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICROSEMI

VHE220

ULTRA FAST RECOVERY RECTIFIERS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICROSEMI