VMS-100C-24 [CUI]

AC-DC POWER SUPPLY;
VMS-100C-24
型号: VMS-100C-24
厂家: CUI INC    CUI INC
描述:

AC-DC POWER SUPPLY

文件: 总7页 (文件大小:1647K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Additional Resources: Product Page  
|
3D Model  
date 06/15/2021  
page 1 of 7  
SERIES: VMS-100C DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• universal input voltage (85 ~ 264 Vac)  
• wide operating temperature (-40 to +85C)  
• active power factor correction  
• certified to 60601, 60335, and 61558 safety standards  
• suitable for safety class I or class II installations  
• over voltage, over current, over temperature, and short circuit protections  
• adjustable output via trim POT  
• low leakage current (< 0.1 mA)  
• low standby power consumption (0.5 W)  
output  
voltage  
output  
current  
output  
power  
transient2  
output  
power  
ripple  
efficiency4  
MODEL  
and noise3  
range1  
(Vdc)  
max  
(A)  
max  
(W)  
max  
(W)  
max  
(mVp-p)  
typ  
(%)  
(Vdc)  
12  
VMS-100C-12  
VMS-100C-15  
VMS-100C-24  
VMS-100C-27  
VMS-100C-36  
VMS-100C-48  
11.4~12.6  
14.3~15.8  
22.8~25.2  
25.6~28.4  
35.28~37.8  
45.6~50.4  
8.33  
6.66  
4.16  
3.70  
2.78  
2.08  
100  
100  
100  
100  
100  
100  
125  
125  
125  
125  
125  
125  
120  
120  
150  
150  
200  
200  
94.0  
94.0  
95.0  
95.0  
94.0  
94.5  
15  
24  
27  
36  
48  
Notes:  
1. When the output voltage is increased, the total output power cannot exceed the nominal output power.  
2. If the total output power exceeds the nominal output power, it can be maintained for a maximum of 10 seconds, but not repeated for at least 30 minutes. The power  
supply cannot exceed the transient power.  
3. At full load, nominal input, 20 MHz bandwidth oscilloscope, tip & barrel method, output terminated with 47 µF electrolytic and 0.1 µF ceramic capacitors.  
Under light load conditions (<15%) the measurement may double in an effort to maximize converter efficiency.  
4. At 230 Vac.  
PART NUMBER KEY  
VMS-100C - XX - XXX  
Chassis:  
“blank” = open-frame  
CNF = covered  
Base Number  
Output Voltage  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VMS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 06/15/2021 page 2 of 7  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
ac input  
dc input  
85  
120  
264  
370  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 115 Vac  
at 230 Vac  
2.0  
1.0  
A
A
at 115 Vac, cold start  
at 230 Vac, cold start  
40  
75  
A
A
inrush current  
leakage current  
at 240 Vac  
0.1  
mA  
at 115 Vac, full load  
at 230 Vac, full load  
0.98  
0.94  
power factor correction  
no load power consumption  
0.5  
W
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
12 Vdc output model  
15 Vdc output model  
24 Vdc output model  
27 Vdc output model  
36 Vdc output model  
48 Vdc output model  
6,000  
5,000  
3,200  
2,400  
2,000  
1,600  
μF  
μF  
μF  
μF  
μF  
μF  
output capacitance  
at full load, 25°C  
12 & 15 Vdc output models  
24, 27, 36 & 48 Vdc output models  
initial set point accuracy  
±2  
±1  
%
%
line regulation  
load regulation  
hold-up time  
rated load  
±0.5  
±1  
%
%
0 ~ 100% load  
at 230 Vac, 25°C  
15  
ms  
temperature coefficient  
adjustability  
±0.03  
±5  
%/°C  
%
via built-in trimpot  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
output shutdown, latching  
12 Vdc output model  
15 Vdc output model  
24 Vdc output model  
27 Vdc output model  
36 Vdc output model  
48 Vdc output model  
16  
25  
32  
35  
50  
60  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
over voltage protection  
over current protection  
short circuit protection  
over temperature protection  
hiccup, auto recovery  
130  
%
continuous, auto recovery, hiccup  
output shutdown, auto recovery  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VMS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 06/15/2021 page 3 of 7  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to ground for 1 minute; <10 mA  
input to output for 1 minute; <10 mA  
output to ground for 1 minute; <10 mA  
1,500  
4,000  
1,500  
Vac  
Vac  
Vac  
isolation voltage  
safety approvals  
certified to 60601: ES, EN  
certified to 60335: EN  
certified to 61558: EN  
safety class  
class I (with PE), class II (without PE)  
CISPR32/EN55032 CLASS B  
conducted emissionsꢀ  
radiated emissionsꢀ  
harmonic current  
ESD  
CISPR32/EN55032 (Class B for safety class I installations; Class A for safety class II installations)  
IEC/EN61000-3-2 CLASS A  
IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV perf. Criteria A  
IEC/EN 61000-4-3 10V/m perf. Criteria A  
radiated immunity  
EFT/burst  
IEC/EN 61000-4-4 ±2KV perf. Criteria A  
surge  
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV perf. Criteria A  
IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A  
conducted immunity  
voltage dips and interruptions  
MTBF  
IEC/EN61000-4-11 0%, 70% perf. Criteria B  
as per MIL-HDBK-217F at 25°C  
300,000  
hours  
RoHS  
yes  
Notes:  
1. The power supply is considered a component of the end system. All EMC performance has been tested on a metal plate with the dimensions 360 x 360 x 1 mm.  
The power supply must be integrated into the end system for proper electromagnetic compatibility testing.  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-40  
20  
typ  
max  
85  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
storage humidity  
see derating curves  
85  
°C  
non-condensing  
non-condensing  
90  
%
10  
95  
%
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VMS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 06/15/2021 page 4 of 7  
DERATING CURVES  
Note: With an AC input voltage between 85 ~ 115 and a DC input between 120 ~ 160 Vdc the output power must be derated as per the temperature derating curve.  
EFFICIENCY CURVES  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VMS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 06/15/2021 page 5 of 7  
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
open frame models: 76.20 x 50.80 x 31.00 [3.0 x 2.0 x 1.381 inch]  
covered models: 80.0 × 62.0 × 40.0 [3.149 x 2.440 x 1.574 inch]  
mm  
mm  
dimensions  
open frame models  
covered models  
125  
180  
g
g
weight  
cooling  
natural convection (no integrated fan)  
MECHANICAL DRAWING  
Open-frame  
units: mm [inch]  
general tolerance: ±1.00 [±0.039]  
PIN-OUT  
PIN Function  
1
2
AC (N)  
NC  
3
AC (L)  
-Vo  
4, 5  
6, 7  
+Vo  
CONNECTORS  
Product Connector  
Customer Connector  
JST B3P-VH  
or equivalent  
Housing: JST VHR  
Contact: JST SVH-21T-P1.1 or equivalent  
AC CONNECTORS  
DC CONNECTORS  
JST B4P-VH  
or equivalent  
Housing: JST VHR  
Contact: JST SVH-21T-P1.1 or equivalent  
MOUNTING SCREWS  
L
Position  
1 ~ 4  
Screw Spec.  
Torque  
(recommended)  
M3  
6mm  
0.4 N·m  
Note: 1. Class I system 1, 4 positions must be connected to the protective earth ground (  
2. Class II system 1, 4 positions must be connected together.  
3. It is recommended that a minimum distance of 10mm be placed between the PCB  
edge and all other components.  
).  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VMS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 06/15/2021 page 6 of 7  
MECHANICAL DRAWING (CONTINUED)  
Covered  
units: mm [inch]  
general tolerance: ±1.00 [±0.039]  
PIN-OUT  
PIN Function  
1
2
AC (N)  
NC  
3
AC (L)  
-Vo  
4, 5  
6, 7  
+Vo  
CONNECTORS  
Product Connector  
Customer Connector  
Housing: JST VHR  
JST B3P-VH  
AC CONNECTORS  
DC CONNECTORS  
or equivalent  
Contact: JST SVH-21T-P1.1 or equivalent  
JST B4P-VH  
or equivalent  
Housing: JST VHR  
Contact: JST SVH-21T-P1.1 or equivalent  
MOUNTING SCREWS  
L
Position  
Screw Spec.  
Torque  
(recommended)  
1 ~ 2  
3 ~ 4  
M3  
M3  
4mm  
0.4 N·m  
0.4 N·m  
3mm  
Note: 1. Safety Class I integrations require the metal case to be securely fastened to protective  
earth ground ( ).  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: VMS-100C DESCRIPTION: AC-DC POWER SUPPLY  
date 06/15/2021 page 7 of 7  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
OVP updated  
06/08/2021  
06/15/2021  
1.01  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

VMS-100C-27

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-100C-36

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-100C-48

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-100C-CNF

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-120C

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-120C-12

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-120C-15

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-120C-24

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-120C-27

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-120C-36

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-120C-48

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VMS-160

open frame switching power supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI