VMS-275-12 [CUI]
Chassis Mount Power Supply, 12 Vdc, 22.92 A, 275 W;型号: | VMS-275-12 |
厂家: | CUI INC |
描述: | Chassis Mount Power Supply, 12 Vdc, 22.92 A, 275 W 局域网 输出元件 |
文件: | 总6页 (文件大小:627K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page
|
If your application requires forced air, view our Dc Fans
date 09/05/2017
page 1 of 6
SERIES: VMS-275 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 275 W continuous power
• -40°C to 70°C operating temperature
• industry standard foot print 3” x 5”
• low profile 0.75”
• power factor correction
• 12 V/0.5 A fan output
• standby power <0.5 W
• efficiency up to 92%
• long life electrolytic capacitors
• complying with the latest EMI standard
IEC 60601-1-2: 2014 (4th edition)
output
voltage
output
current
max
output
ripple
efficiency
MODEL
power1,2
and noise3,4
max
max
typ
(Vdc)
12
(A)
(W)
(mVp-p)
(%)
VMS-275-12
VMS-275-15
VMS-275-24
VMS-275-30
VMS-275-48
VMS-275-58
22.92
18.33
11.46
9.17
275
275
275
275
275
275
240
300
240
300
480
580
88
88
90
90
92
92
15
24
30
48
5.73
58
4.74
Notes:
1. Maximum output power of 275 W with 13 CFM forced air cooling, and 160 W with natural convection cooling at 100 to 264 Vac.
2. Combined output power of main output and fan supply shall not exceed the max power rating.
3. Ripple is peak to peak with 20 MHz bandwidth and 10 µF tantalum capacitor in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Output ripple can be more than 10% of the output voltage at -40°C.
5. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
VMS-275 - XX - X
Output Connections:
“blank” = screw type
1 = header type
Base Number
Output Voltage
cui.com
For more information, please visit the product page
|
If your application requires forced air, view our Dc Fans
CUI Inc │SERIES: VMS-275 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/05/2017 │ page 2 of 6
INPUT
parameter
voltage
conditions/description
min
80
typ
max
264
63
units
Vac
frequency
47
Hz
at 115 Vac, full load
at 230 Vac, full load
2.6
1.3
A
A
current
inrush current
at 230 Vac, cold start
at 230 Vac
45
0.1
0.5
A
leakage current
touch current
0.3
mA
mA
power factor
at full load
0.95
no load power consumption
input fuse
W
6.3 A/250 V time delay fuse (included)
OUTPUT
parameter
conditions/description
min
typ
±1
±0.5
±1
2
max
units
%
initial set point accuracy
line regulation
load regulation
start-up delay time
rise time
%
from 100% to 10% load
%
s
at 115/230 Vac
at 115/230 Vac
built in trim pot
55
ms
ms
%
hold-up time
adjustability1
8
±3
switching frequency
50
300
kHz
25% step load change, at 0.1 A/µS slew rate, 50%
duty cycle, 50/60 Hz, max excursion 4%, recovery
time 5 ms
transient response
temperature coefficient
at 0~50°C
±0.05
%/°C
fan output2
12 Vdc / 500 mA
Notes:
1. Adjustment potentiometer is located on the SMT side of the PCB.
2. Fan supply output voltage tolerance including set point accuracy, line and load regulation is ±10% and ripple and noise is less than 10%.
PROTECTIONS
parameter
conditions/description
hiccup, auto recovery
hiccup, auto recovery
hiccup, auto recovery
min
110
110
typ
max
units
%
over voltage protection
over current protection
short circuit protection
140
%
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to output (2 x MOPP)
input to ground (1 x MOPP)
output to ground
4,200
1,500
1,500
Vac
Vac
Vac
isolation voltage
IEC 60601-1: 2005 +CORR1:2006
+CORR2:2007 +AM1:2012, EN 60601-1:2006
+A11:2011 +A1:2013, ANSI/AAMI ES 60601-1
(2005+CI:09+A2:10), AMD1:2012 CAN/CSA-
C22.2 No 60601-1 (2008) 60601-1:14 ISO 14971,
2nd edition complies with LVD directive
safety approvals
safety class
class I
conducted emissions
EN 55011 Class B
Notes:
3. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
cui.com
For more information, please visit the product page
|
If your application requires forced air, view our Dc Fans
CUI Inc │SERIES: VMS-275 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/05/2017 │ page 3 of 6
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
EN 55011 Class B (to be controlled in end system with external
core (King core K5B RC 25 x 12 x 15-M in input cable (5 turns))
radiated emissions
input current harmonics
voltage fluctuation and flicker
ESD immunity
EN 61000-3-2, class D
EN 61000-3-3, pass
EN 61000-4-2, level 4, criterion A
EN 61000-4-3, level 4, criterion A
radiated field immunity
electrical fast transient
immunity
EN 61000-4-4, level 4, criterion A
surge immunity
conducted immunity
magnetic field immunity
voltage dips, interruptions
MTBF
EN 61000-4-5, level 4, criterion A
EN 61000-4-6, level 4, criterion A
EN 61000-4-8, level 4, criterion A
EN 61000-4-11, criterion B
as per Telcordia-SR332-issue 3
2011/65/EU
3,370,000
hours
RoHS
Notes:
1. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
ENVIRONMENTAL
parameter
conditions/description
min
-40
-40
20
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
see derating curves
85
°C
non-condensing
non-condensing
90
%
20
90
%
operating altitude
16,000
ft
DERATING CURVES
Output Power vs. Input Voltage
Output Power vs. Ambient Temperature
280
260
Forced Air (13 CFM)
275
250
225
200
Forced Air (13 CFM)
240
220
200
180
160
140
120
100
80
175
150
Natural Convection
Natural Convection
125
100
75
60
50
40
25
0
20
0
80
85
90
95 100
105 110
255 260
264
-40 -30 -20 -10
0
10 20 30 40 50 60 70
Input Voltage (Vac)
Ambient Temperature (°C)
cui.com
For more information, please visit the product page
|
If your application requires forced air, view our Dc Fans
CUI Inc │SERIES: VMS-275 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/05/2017 │ page 4 of 6
MECHANICAL
parameter
dimensions
weight
conditions/description
min
typ
max
units
inch
g
5.00 x 3.00 x 0.75 (127.00 x 76.20 x 19.05 mm)
200
cooling
external fan
J1 input connector
Mates with JST housing VHR-3M; pins SVH-41T-P1.1 or equivalent
Screw Type: Accepts 28 ~ 16 AWG wire
Header Type: Mates with JST housing VHR-6M; pins SVH-41T-P1.1 or equivalent
J2 output connector
J3 fan connector
Mates with Tyco 640440-2
MECHANICAL DRAWINGS
Screw Type
units: inch [mm]
tolerance: ±0.04 [±1.0]
5.000 [127.00]
J1
0.225 [5.70]
4.551 0.008 [115.60 0.2]
PIN
1
Function
L
NC
N
DIRECTION OF AIRFLOW
2
40x40x15 MM
EARTH
CONNECTION
EARTH
CONNECTION
RECOMMENDED FAN SIZE
3
0.094 [2.40]
0.225 [5.70]
COMPONENT
HEIGHT BELOW PCB
J2
PIN
1
Function
+VE
+VE
+VE
-VE
2
3
4
5
-VE
6
-VE
J3
PIN
1
Function
+FAN
0.593 [15.05]
MOUNTING HOLES
DIA 0.157[DIA 4.0]
4-PLS
COMPONENT
HEIGHT ABOVE
PCB
2
-FAN
0.75 [19.05]
cui.com
For more information, please visit the product page
|
If your application requires forced air, view our Dc Fans
CUI Inc │SERIES: VMS-275 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/05/2017 │ page 5 of 6
MECHANICAL DRAWINGS (CONTINUED)
Header Type
units: inch [mm]
tolerance: ±0.04 [±1.0]
5.000 [127.00]
J1
0.225 [5.70]
4.551 0.008 [115.60 0.2]
PIN
1
Function
L
NC
N
DIRECTION OF AIRFLOW
2
40x40x15 MM
EARTH
CONNECTION
EARTH
CONNECTION
RECOMMENDED FAN SIZE
3
0.094 [2.40]
0.225 [5.70]
COMPONENT
HEIGHT BELOW PCB
J2
PIN
1
Function
+VE
+VE
+VE
-VE
2
3
4
5
-VE
6
-VE
J3
PIN
1
Function
+FAN
0.593 [15.05]
MOUNTING HOLES
DIA 0.157[DIA 4.0]
4-PLS
COMPONENT
HEIGHT ABOVE
PCB
2
-FAN
0.75 [19.05]
cui.com
For more information, please visit the product page
|
If your application requires forced air, view our Dc Fans
CUI Inc │SERIES: VMS-275 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/05/2017 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
09/05/2017
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明