page 1 of 4  
SERIES: VMS-40 DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• up to 40 W continuous power  
• compact size  
• universal input (90~264 Vac)  
• single output from 3.3~48 V  
• no load power < 0.3W  
• over voltage and short circuit protections  
• full medical safety approvals  
• efficiency up to 88%  
RoHS  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efciency  
MODEL  
and noise1  
max  
typ  
(Vdc)  
3.3  
5
(A)  
(W)  
(mVp-p)  
(%)  
VMS-40-3.3  
VMS-40-5  
6
19.8  
30  
40  
40  
40  
40  
40  
40  
40  
50  
50  
76  
80  
84  
86  
87  
88  
88  
88  
88  
6
VMS-40-9  
9
4.45  
3.34  
2.67  
1.67  
1.33  
1.11  
0.834  
90  
VMS-40-12  
VMS-40-15  
VMS-40-24  
VMS-40-30  
VMS-40-36  
VMS-40-48  
12  
15  
24  
30  
36  
48  
120  
150  
240  
300  
360  
480  
Notes:  
1. Measured at 20MHz, with 0.1uF ceramic and 10uF electrolytic capacitors  
PART NUMBER KEY  
VMS-40 - XX  
Base Number  
Output Voltage  
cui.com  
For more information, please visit the product page.  
date 08/28/2012 page 2 of 4  
CUI Inc SERIES: VMS-40 DESCRIPTION: AC-DC POWER SUPPLY  
INPUT  
parameter  
voltage  
conditions/description  
min  
90  
typ  
max  
264  
63  
units  
Vac  
frequency  
47  
Hz  
at 100 Vac  
at 240 Vac  
1
0.55  
A
A
input current  
inrush current  
at 240 Vac  
60  
A
OUTPUT  
parameter  
conditions/description  
low line to high line, full load  
10% to 100% full load  
115 Vac  
min  
typ  
±0.5  
±1  
max  
units  
%
line regulation  
load regulation  
hold-up time  
%
10  
ms  
switching frequency  
65  
KHz  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
max  
units  
over voltage protection  
short circuit protection  
TVS component to clamp  
hiccup mode, recovers automatically  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
units  
isolation voltage  
input to output  
5,656  
Vdc  
safety approvals  
UL 60601-1, EN 60601-1, IEC 60601-1, CAN/CSA-C22.2 60601-1, ANSI/AAMI ES 60601-1  
FCC CFR 47 Part 15 Subpart B, CISPR 22 Class B, EN 55011 Class B, EN 61000-3-(2, 3), IEC 61000-4-  
(2, 3, 4, 5, 6, 8, 11)  
EMI/EMC  
leakage current  
RoHS compliant  
MTBF  
0.1  
mA  
yes  
MIL-HDBK-217F, GB, at 25°C, 115 Vac  
200,000  
hrs  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
0
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
see derating curve  
-20  
85  
°C  
non-condensing  
93  
%
DERATING CURVES  
output power vs. ambient temperature  
5 V model  
(Natural Convection)  
All other models (Natural Convection)  
100  
80  
100  
80  
60  
60  
40  
20  
40  
20  
0
10  
20  
30  
40  
50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
cui.com  
For more information, please visit the product page.  
date 08/28/2012 page 3 of 4  
CUI Inc SERIES: VMS-40 DESCRIPTION: AC-DC POWER SUPPLY  
MECHANICAL  
parameter  
dimensions  
weight  
conditions/description  
min  
typ  
max  
units  
inch  
g
3.00 x 2.00 x 0.91 (76.2 x 50.8 x 23.1 mm)  
90  
free air convection  
(see derating curves below)  
cooling method  
MECHANICAL DRAWING  
units: mm[in]  
tolerance: mm: ±0.5  
inch: ±0.02  
3.60 0.142  
68.58 2.700  
3.81 0.150  
(4 PLCS)  
CN1  
CN1  
1
2
3
1
2
3
AC Line  
No pin  
CN2  
50.80 2.000  
CN2  
1
2
3
4
AC Neutral  
1
2
3
4
+Vo  
JST VHR  
Connector  
3 Pin,  
43.18 1.700  
+Vo  
-Vo  
-Vo  
CTR Pin removed  
JST VHR  
3.96 spacing  
Connector  
4 Pin  
3.96 spacing  
76.20 3.000  
3.81 0.150  
19.00 0.748  
MAX  
2.50 0.098  
MAX  
1.60 0.063  
cui.com  
For more information, please visit the product page.  
date 08/28/2012 page 4 of 4  
CUI Inc SERIES: VMS-40 DESCRIPTION: AC-DC POWER SUPPLY  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
10/26/2011  
08/27/2012  
1.01  
V-Innity branding removed  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

VMS-550

AC-DC POWER SUPPLY
CUI

VMS-550-12

AC-DC POWER SUPPLY
CUI

VMS-550-15

AC/DC CONVERTER 15V 120W/500W
CUI

VMS-550-24

Chassis Mount Power Supply, 24 Vdc, 22.92 A, 550 W
CUI

VMS-550-30

AC/DC CONVERTER 30V 150W/550W
CUI

VMS-550-48

AC/DC CONVERTER 48V 150W/550W
CUI

VMS-550-58

Chassis Mount Power Supply, 58 Vdc, 9.48 A, 550 W
CUI

VMS-60-12

AC-DC POWER SUPPLY
CUI

VMS-60-15

AC-DC POWER SUPPLY
CUI

VMS-60-24

AC-DC POWER SUPPLY
CUI

VMS-60-48

AC-DC POWER SUPPLY
CUI

VMS-60-5

AC-DC POWER SUPPLY
CUI