VOF-65C-S5 [CUI]

AC-DC POWER SUPPLY;
VOF-65C-S5
型号: VOF-65C-S5
厂家: CUI INC    CUI INC
描述:

AC-DC POWER SUPPLY

文件: 总6页 (文件大小:412K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Additional Resources: Product Page  
date 10/28/2019  
page 1 of 6  
SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• universal input voltage range (85~264 VAC)  
• 3 × 2 x 1.2 in (76.2 x 50.8 x 30 mm)  
• class B EMI performance, meets CISPR32 / EN55032  
• output short circuit, overcurrent & overvoltage protection  
• safety certified: IEC/EN/UL 62368  
output  
voltage  
output  
current  
output  
power  
max  
ripple  
efficiency2  
MODEL  
and noise1  
min  
max  
max  
typ  
(Vdc)  
5
(mA)  
(mA)  
(W)  
(mVp-p)  
(%)  
VOF-65C-S5  
VOF-65C-S9  
VOF-65C-S12  
VOF-65C-S15  
VOF-65C-S24  
VOF-65C-S48  
0
0
0
0
0
0
10000  
6600  
5420  
4340  
2710  
1360  
50  
60  
65  
65  
65  
65  
150  
150  
150  
150  
150  
150  
80  
83  
85  
85  
87  
87  
9
12  
15  
24  
48  
Notes:  
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 1 µF ceramic and 10 µF electrolytic capacitors on the output.  
2. At 230 Vac input.  
3. All specifications are measured at Ta=25°C, humidity <75%, nominal input voltage, and rated output load unless otherwise specified.  
PART NUMBER KEY  
VOF-65C - SXX  
Base Number  
Output Voltage  
cui.com  
Additional Resources: Product Page  
CUI Inc SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY  
date 10/28/2019 page 2 of 6  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
100  
264  
370  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 115 Vac  
at 230 Vac  
1600  
900  
mA  
mA  
at 115 Vac  
at 230 Vac  
35  
50  
A
A
inrush current  
no load power consumption  
0.5  
W
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
40,000  
12,000  
8,000  
7,000  
1,500  
1,000  
5 Vdc output models  
9 Vdc output models  
12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
48 Vdc output models  
capacitive load  
µF  
initial set point accuracy  
line regulation  
±2  
±0.5  
±1  
%
%
%
at full load  
load regulation  
from 5~100% load  
hold-up time  
at 230 Vac, full load  
35  
ms  
switching frequency  
65  
kHz  
temperature coefficient  
±0.02  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
output voltage clamp, auto recovery  
5 Vdc output models  
9 Vdc output models  
12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
48 Vdc output models  
7.5  
9
16  
20  
24  
35  
60  
over voltage protection  
Vdc  
over current protection  
hiccup, auto-recovery  
120  
300  
%
short circuit protection  
hiccup, continuous, auto-recovery  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to output electric strength test for 1 minute,  
leakage current <5 mA  
isolation voltage  
3,000  
Vac  
safety approvals  
safety class  
IEC/UL/EN 62368-1 certified  
Class II  
conducted emissions  
radiated emissions  
ESD  
CISPR32/EN55032, Class B  
CISPR32/EN55032, Class B  
IEC/EN61000-4-2, Contact ±6KV, Perf. Criteria B  
IEC/EN61000-4-3 10V/m perf. Criteria A  
radiated immunity  
cui.com  
Additional Resources: Product Page  
CUI Inc SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY  
date 10/28/2019 page 3 of 6  
(
)
SAFETY & COMPLIANCE CONTINUED  
parameter  
conditions/description  
min  
typ  
max  
units  
EFT/burst  
IEC/EN61000-4-4, ±2 kV, perf. Criteria B  
IEC/EN61000-4-5, line to line ±1KV, perf. Criteria B  
IEC/EN61000-4-6, 10 Vrms, Perf. Criteria A  
IEC/EN61000-4-11 , 0%,70%, perf. Criteria B  
as per MIL-HDBK-217F at 25°C  
surge  
conducted immunity  
voltage dips & interruptions  
MTBF  
300,000  
hours  
RoHS  
yes  
Notes:  
4. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-25  
-25  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
see derating curves  
85  
°C  
non-condensing  
90  
%
cui.com  
Additional Resources: Product Page  
CUI Inc SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY  
date 10/28/2019 page 4 of 6  
DERATING CURVES  
Load vs. Ambient Temperature  
(at 85~264 Vac / 100~370 Vdc Input Voltage)  
Load vs. Input Voltage  
(at 25°C Ambient Temperature)  
100  
100  
80  
70  
60  
80  
70  
60  
40  
20  
40  
20  
-25  
-10  
50  
70  
85  
100  
165  
230  
240  
340  
264 Vac  
370 Vdc  
Ambient Temperature (°C)  
EFFICIENCY CURVES  
Efficiency vs. Input Voltage  
Efficiency vs. Load Current  
(at full load)  
(at 230 Vac)  
cui.com  
Additional Resources: Product Page  
CUI Inc SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY  
date 10/28/2019 page 5 of 6  
MECHANICAL  
parameter  
dimensions  
weight  
conditions/description  
min  
typ  
max  
units  
mm  
g
76.20 x 50.80 x 30.00  
95  
MECHANICAL DRAWING  
units: mm[inch]  
tolerance: ±0.50[±0.020]  
In CON1 model: VH-3A, Recommended terminal: VH-3Y  
Out CON2 model: VH-4A, recommended terminal: VH-4Y  
Mounting hole screwing torque: Max 0.4 N·m  
PIN-Out  
PIN  
1
Function  
AC(L)  
NoPin  
AC(N)  
-Vo  
Connector  
Terminal  
VH-3A  
or B2P3-VH  
or the same Spec. or the same Spec.  
VH-3Y  
or VHR-3N  
2
3
4
5
-Vo  
VH-4A  
VH-4Y  
or B4P-VH  
or the same Spec. or the same Spec.  
or VHR-4N  
6
7
+Vo  
+Vo  
cui.com  
Additional Resources: Product Page  
CUI Inc SERIES: VOF-65C DESCRIPTION: AC-DC POWER SUPPLY  
date 10/28/2019 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
10/17/2019  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

VOF-65C-S9

AC-DC Regulated Power Supply Module

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-65_11

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-65_12

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6B

short circuit, over voltage protection, over current protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6B-S12

Board Mount AC-DC Power Supply, 12 Vdc, 0.5 A, 6 W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6B-S15

short circuit, over voltage protection, over current protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6B-S24

Board Mount AC-DC Power Supply, 24 Vdc, 0.25 A, 6 W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6B-S5

Board Mount AC-DC Power Supply, 5 Vdc, 1.2 A, 6 W

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6B-S9

short circuit, over voltage protection, over current protection

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6_10

SWITCHING POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6_11

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VOF-6_15

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI