VPF-S600-24R [CUI]

Switching Power Supply; 开关电源
VPF-S600-24R
型号: VPF-S600-24R
厂家: CUI INC    CUI INC
描述:

Switching Power Supply
开关电源

开关
文件: 总5页 (文件大小:308K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1 / 5  
VPF-S600 Switching Power Supply  
Rev. 12-2006  
Features  
·Built-in active PFC function  
·Short Circuit, overload, over voltage,  
over temperature protected  
·Current Sharing (Available)  
·Current Monitoring  
·Power Good Signal  
·Built-in Remote Inhibit  
·Built-in Remote Sense  
·Extended temperature range: -40 ~ +75 ºC  
available  
7, 8  
Preset  
Output Current  
Ripple & Noise  
1
2, 3, 4  
5, 6  
7
Model  
Voltage Output  
Minimum  
0 A  
Maximum  
90 A  
Max. Power  
297 W  
Regulation  
+/- 1%  
+/- 1%  
+/- 1%  
+/- 1%  
+/- 1%  
+/- 1%  
+/- 1%  
(Vpp)  
VPF-S600-03R(I)  
VPF-S600-05R(I)  
VPF-S600-12R(I)  
VPF-S600-16R(I)  
VPF-S600-24R(I)  
VPF-S600-36R(I)  
VPF-S600-48R(I)  
3.3V  
5V  
2 - 3.3 V  
5 - 6 V  
50 mV  
50 mV  
1%  
0 A  
90 A  
450 W  
12V  
16V  
24V  
36V  
48V  
12 - 15 V  
16 - 21 V  
22 - 30 V  
31 - 47 V  
48 - 56 V  
0 A  
50 A  
600 W  
0 A  
37.5 A  
27.27 A  
19.35 A  
12.5 A  
600 W  
1%  
0 A  
600 W  
1%  
0 A  
600 W  
1%  
0 A  
600 W  
1%  
Notes:  
1 Adding “I” Indicates Current sharing model.  
2 Customer must specify output voltage.  
3 Output is fully isolated.  
4 Output voltage is measured at output power connector.  
5 Provides peak power of 900 W within 500 µS for all models. For longer duty duration please contact us.  
6 Must use external forced airflow min. 30 CFM to achieve maximum power.  
7 1% minimum load is required to maintain the ripple and regulation.  
8 Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 µF ceramic capacitor and  
a 22 µF electrolytic capacitor in parallel.  
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062  
www.v-infinity.com  
1-866-372-1258  
2 / 5  
VPF-S600 Switching Power Supply  
Rev. 12-2006  
Input  
Parameter  
Conditions/Description  
Min  
47  
Nom  
Max  
Units  
Hz  
Input Frequency  
Input Voltage  
Input Current  
Inrush Current  
Power Factor  
63  
264  
10  
90  
VAC  
A
At 90-264 VAC  
Peak measured at 230 VAC at full load, cold start  
Active power factor correction meets EN61000-3-2 class D  
70  
A
Output  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Transient response Output voltage returns to within 1% in less than  
2.5 mS for a 50% load change. Peak  
transient does not exceed 5%.  
Overshoot  
Efficiency  
Turn-on and turn-off overshoot shall not exceed  
5% over nominal voltage.  
Measured at 230 V and full load  
12 V model:  
80%  
82%  
All other models:  
Turn on delay  
Hold up time  
Adjustability  
Remote sense  
At 120 VAC  
1
second  
mS  
At 120 VAC and 80% of rated maximim load  
Adjustable with built-in trim pot.  
20  
+/- 5%  
Designated as RS+ and RS- on the CN3. Total voltage compensation for cable losses with  
respect to the main output. (NOT available for current sharing models.)  
Designated as RSW on the CN3. Requires a low signal to inhibit the output.  
Green - the power supply is operating normally.  
Remote Inhibit  
LED display  
(LED 1)  
Orange - when any protection occurs or when Remote Inhibit is in effect.  
Designated as PG on the CN3. This signal  
Power Good  
goes high 100-500 mS after the output reaches regulation.  
It goes low at least 1 mS before loss of regulation.  
Current Sharing  
Current Monitor  
Designated as CSH on (CN3), use in parallel for forced current sharing function.  
Accuracy of shared current with up to 4 parallel units is within 10% at full load.  
Disignated as CMN on (CN3) for current sense purpose. CMN is a 0.5 to 3VDC output  
voltage to represent a linear 0% to 100% output current.  
Protection Circuit  
Parameter  
Conditions/Description  
Input Fuse  
Built-in ac fuse. A blown fuse usually indicates permanent  
damage to the power supply serviceable by factory only.  
Power supply shuts down when ac input is under  
Input under-voltage  
Overload  
80 VAC. When ac line reappears over 86 +/- 5 VAC,  
the power supply restarts automatically.  
Current limiting starts at 110-140% of the rated output current and  
recovers automatically.  
Short circuit  
Short circuit can be continuous. Recovers automatically upon removal of short.  
Output is protected agaist overvoltage. Unit shuts down and latches  
when voltage at output terminals exceeds 130%. AC input needs to be  
reset to restart the power supply.  
Output Over-voltage  
Over temp.  
Power supply shuts down when temperature is in excess of 85 ºC. Auto recovery.  
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062  
www.v-infinity.com  
1-866-372-1258  
3 / 5  
VPF-S600 Switching Power Supply  
Rev. 12-2006  
General and Safety  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Operating temp.  
Derates linearly from 100% load at 50 ºC to 50%  
load at 70 ºC.  
0
50  
ºC  
Optional operating  
temp.  
Derates linearly from 100% load at 50 ºC to 37.5%  
load at 75 ºC.  
-40  
75  
ºC  
Storage temp.  
Optional storage  
temp.  
-20  
-40  
85  
85  
ºC  
ºC  
Operating humid.  
Storage humid.  
EMI  
Non-condensing  
Non-condensing  
5%  
5%  
90%  
95%  
RH  
RH  
Pass FCC Part 15 Subject J Class B, CISPR 22 class B, CE Mark  
Safety  
UL60950-1 (E222889), CSA C22.2 No. 950-95, TUV EN60950 and CB  
Leakage Current  
Isolation Voltage  
(HI-POT)  
at 264 VAC  
3.5  
0.1  
mA  
Applied for 3 seconds  
Primary to secondary:  
3000  
1500  
1500  
VAC  
VAC  
VAC  
Ohm  
Primary to transformer core:  
Primary to earth ground:  
Grounding Test  
Allowable resistance measured when 25 A current is  
applied from the ground pin of the three prong plug  
to the farthest earthed connection point.  
Standard warranty length  
Warranty  
MTBF  
2
8
years  
hours  
hours  
According to MIL-HDBK-217 at 30 ºC  
Full load, at 45 +/- 5 ºC, 230 VAC. Burn-in for  
up to 8 hours in early productions. Time  
reduced gradually as product matures.  
150,000  
1
Burn-in  
Note: Customer must specify extended temperature on PO.  
Mechanical  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
grams  
inches  
Weight  
1450  
Enclosure  
Mounting holes  
8.00(L) x 4.33(W) x 2.56(H)  
Two sets of 8 threaded mounting holes available on the enclosure  
B: 6-32, maximum insertion depth of 0.2 inches.  
C: M4, maximum insertion depth of 0.2 inches.  
Input Connector - (CN1)  
Parameter  
Conditions/Description  
AC input (Option 1) Molex Part No. 26-48-1201 or similar (5 pin).  
Suggested mating plug: Molex Part No. 09-91-0500 or equivalent (5 pin, 3 used)  
AC Input (Option 2) Howder Terminal block Part No. HD-121-3P (3 pin, M3 Screw) 9.5mm spacing  
Suggested mating connector: Molex 19198-0045 or similar  
Note: Input connector needs to be specified on the PO.  
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062  
www.v-infinity.com  
1-866-372-1258  
4 / 5  
VPF-S600 Switching Power Supply  
Rev. 12-2006  
Output Connector - (CN2)  
Conditions/Description  
Parameter  
Output (Option 1)  
Molex Part No. 26-48-1201 or similar.(20 pin)  
Output pin assignment, VO+ (Pins 1-10), VO- (Pins 11-20)  
Suggested mating connector: Molex Part No. 09-91-2000, contact:08-50-0106 or similar.  
Howder Terminal block Part No. HD-121-8P (8 pin, M3.5 Screw) 9.5mm spacing  
Output pin assignment, VO+ (Pins 1-4), VO- (Pins 5-8)  
Output (Option 2)  
Suggested mating connector: Molex 19198-0045 or similar.  
Note: Output connector needs to be specified on the PO.  
Logic Connector - (CN3)  
Parameter  
Conditions/Description  
Logic  
JS B7B-XH-A  
Suggested mating connector: JST XHP-7 or equivalent , Contact: SXH-001T-P0.6.  
1. CMN - Current Monitoring  
Pin Assignments:  
2. CSH - Current Sharing  
3. RTN - Return / Output Ground  
4. PG - Power Good Signal  
5. RSW - (Remote On-Off / Remote Inhibit)  
6. RS(-) - Remote Sense  
7. RS(+) - Remote Sense  
Fan  
JST B2B-XH-A  
Suggested mating connector: JST XHP-2 or equivalent, Contact: SXH-001T-P0.6.  
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062  
www.v-infinity.com  
1-866-372-1258  
5 / 5  
VPF-S600 Switching Power Supply  
Rev. 12-2006  
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062  
www.v-infinity.com  
1-866-372-1258  

相关型号:

VPF-S600-36R

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S600-48R

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-12R-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-12RI-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-15R-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-15RI-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-24R-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-24RI-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-36R-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-36RI-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VPF-S800-40R-N

Switching Power Supply

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI