SERIES: VQB100R │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• up to 100 W isolated output
• industry standard quarter brick package
• 3:1 input range (66~160 V)
• single output from 5~24 V
• 1,500 V isolation
• over current, over temperature, over voltage,
and short circuit protections
• remote on/off
• efficiency up to 92%
input
voltage
range
output
voltage
output
current
max
output
power
max
ripple
efficiency
MODEL
and noise1
max
typ
(Vdc)
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
VQB100R-T110-S5
VQB100R-T110-S12
VQB100R-T110-S24
66 ~ 160
66 ~ 160
66 ~ 160
20
8.4
4.2
100
100
100
100
150
240
90
92
91
12
24
Notes:
1. ripple and noise are measured at 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output
PART NUMBER KEY
VQB100R-T110 - SXX
Base Number
Input Voltage
Output Voltage
cui.com
CUI Inc │ SERIES: VQB100R │ DESCRIPTION: DC-DC CONVERTER
date 01/29/2013 │ page 2 of 4
INPUT
parameter
conditions/description
min
typ
max
160
180
units
Vdc
operating input voltage
input surge voltage
66
110
100 ms max.
Vdc
power up
power down
62
56
Vdc
Vdc
under voltage lockout
positive logic remote on/off1
filter
PI type
Notes:
1. logic compatibility, open collector ref to -input
Module ON, >3.5 ~ 75 Vdc or open circuit
Module OFF, <1.8 Vdc
OUTPUT
parameter
conditions/description
min
typ
max
±0.2
±0.2
units
%
line regulation
load regulation
start-up time
voltage accuracy
measured from high line to low line
measured from full load to zero load
%
45
ms
%
±1.5
error band
25% step load change
recover time
±5
200
% Vout
µs
transient response
adjustability2
±10
200
%
switching frequency
temperature coefficient
100% load, input voltage range
kHz
±0.03
%/°C
Notes:
2. trim-up: connect a resistor between the trim pin and -Sense
trim-down: connect a resistor between the trim pin and +Sense
PROTECTIONS
parameter
conditions/description
%Vo
min
typ
max
units
over voltage protection
short circuit protection
current limit
115
140
%
continuous
% nominal output current
110
180
%
thermal shutdown case temp.
105
°C
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to output
input to case
output to case
2,250
2,250
1,500
Vdc
Vdc
Vdc
isolation voltage
isolation resistance
isolation capacitance
safety approvals
EMI/EMC
10
MΩ
1,000
pF
UL 60950-1
EN 50155 (EN 50121-3-2) with external filter
RoHS compliant
yes
cui.com
CUI Inc │ SERIES: VQB100R │ DESCRIPTION: DC-DC CONVERTER
date 01/29/2013 │ page 3 of 4
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
max
100
105
95
units
°C
case operating temperature
storage temperature
humidity
°C
non-condensing
%
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
2.28 x 1.45 x 0.5 (57.9 x 36.8 x 12.7 mm)
aluminum baseplate with plastic case
inch
case material
weight
61.5
g
MECHANICAL DRAWING
units: inches [mm]
tolerance: x.xx ± 0.2inches [±0.5mm]
x.xxx ± 0.1inches [±0.25mm]
2.28
[57.9]
2.000[50.8]
PIN CONNECTIONS
PIN FUNCTION
Mounting Inserts
M3*0.5 Through 2pl.
1
2
3
4
5
6
7
8
+Vin
On/Off
-Vin
-Vo
3
2
1
4
5
6
7
8
-S
TRIM
+S
BOTTOM VIEW
1.86[47.2]
+Vo
0.040[1.02]
0.059[1.50]
DIA 6PLACES
DIA 2PLACES
cui.com
CUI Inc │ SERIES: VQB100R │ DESCRIPTION: DC-DC CONVERTER
date 01/29/2013 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
06/20/2012
11/13/2012
01/29/2013
1.01
1.02
misc. updates, added product photo
updated input voltage range and drawing
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
VQB100R-T110-S12
DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB100R-T110-S24
DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB100R-T110-S5
DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S1
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S12
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S1R2
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S1R5
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S1R8
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S2R5
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S3R3
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VQB125-D48-S5
DC/DC converterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
©2020 ICPDF网 联系我们和版权申明