VSK-S2-15U [CUI]
AC-DC POWER SUPPLY; AC- DC电源供应器型号: | VSK-S2-15U |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总4页 (文件大小:173K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
date 08/16/2012
page 1 of 4
SERIES: VSK-S2 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 2 W continuous power
• compact board mount design
• universal input (85~305 Vac / 120~430 Vdc)
• single output from 3.3~24 V
• over current and short circuit protection
• UL/cUL and CE safety approvals
• efficiency up to 78%
RoHS
output
voltage
output
current
max
output
power
max
ripple
efficiency
MODEL
and noise1
max
typ
(Vdc)
3.3
5
(A)
(W)
(mVp-p)
(%)
VSK-S2-3R3U
VSK-S2-5U
VSK-S2-9U
VSK-S2-12U
VSK-S2-15U
VSK-S2-24U
0.6
2
2
2
2
2
2
200
200
200
200
200
200
65
70
72
76
76
78
0.4
9
0.222
0.167
0.133
0.083
12
15
24
Notes:
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors.
2. All specifications are measured at rated input voltage, rated output load, TA=25°C, and humidity < 75% unless otherwise specified
PART NUMBER KEY
VSK-S2 - XX U
Base Number
Output Voltage
cui.com
CUI Inc │ SERIES: VSK-S2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/16/2012 │ page 2 of 4
INPUT
parameter
conditions/description
min
typ
max
units
85
120
305
430
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 110 Vac
at 230 Vac
44
25
mA
mA
at 110 Vac
at 230 Vac
5
11
A
A
inrush current
OUTPUT
parameter
conditions/description
min
typ
max
±2
units
%
line regulation
load regulation
ripple and noise
10 ~ 100%
±5
%
mVp-p
100
200
3.3 V model
all other models
±6
±5
%
%
voltage accuracy
switching frequency
100
kHz
PROTECTIONS
parameter
conditions/description
min
typ
typ
max
units
over current protection
short circuit protection
110
%
auto recovery with no damage from a short on any output
SAFETY & COMPLIANCE
parameter
conditions/description
for 1 minute
min
max
units
isolation voltage
safety approvals
safety class
3,000
Vac
UL 60950-1, EN 60950-1/IEC 60950-1
class II
EMI/EMC
EN 55022 Class B, IEC/EN 61000-4-(2,3,4,5,6)
leakage current
RoHS compliant
MTBF
0.15
mA
hrs
yes
25°C
300,000
ENVIRONMENTAL
parameter
conditions/description
min
-25
-40
30
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
85
°C
non-condensing
90
%
20
95
%
cui.com
CUI Inc │ SERIES: VSK-S2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/16/2012 │ page 3 of 4
DERATING CURVES
1. output power vs. ambient
temperature
2. efficiency vs. output power
(Vin=220Vac)
3. efficiency vs. input voltage
(load=100%)
80
75
70
80
75
70
65
60
65
60
100
80
60
55
55
50
45
40
20
50
45
40
-40
-20
0
20
40
55
70 80
100
120
10
20
30
40
50
60
70
80
90
100
85
120
220
Load (%)
240
264
305
Ambient Temperature (°C)
Input Voltage (Vac)
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
1.327 x 0.874 x 0.708 (33.70 x 22.20 x 18.00 mm)
UL94V-0
inch
case material
weight
20
g
MECHANICAL DRAWING
units: mm [inches]
tolerance: ±0.5 [±0.02]
pin section tolerance: ±0.10 mm [±0.004]
PIN CONNECTIONS
PIN
1
FUNTION
AC(N)
AC(L)
-Vo
(Front view)
2
3
4
+Vo
ꢃꢂꢅꢃ>ꢃꢂꢃꢆꢉ@
ꢀꢁꢂꢃꢃ
>ꢃꢂꢄꢃꢈ@
ꢇꢇꢂꢄꢃ>ꢀꢂꢇꢆꢄ@
∅1.10[0.43]
ꢇꢇꢂꢄꢃ>ꢀꢂꢇꢆꢄ@
2
1
2
3
4
(Side view)
(Bottom view)
4
1
3
ꢆꢁꢂꢃꢃ>ꢀꢂꢀꢃꢆ@
ꢆꢁꢂꢃꢃ>ꢀꢂꢀꢃꢆ@
cui.com
CUI Inc │ SERIES: VSK-S2 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/16/2012 │ page 4 of 4
TYPICAL APPLICATION CIRCUIT
FUSE NTC
C1
C2
TVS
+Vo
-Vo
L
L
C3
NF
+
C5
RL
MOV
C4
N
N
EXTERNAL CAPACITORS TYPICAL VALUE (Unit: μF)
MODEL
C1
C2
TVS
VSK-S2-3R3U
VSK-S2-5U
VSK-S2-9U
VSK-S2-12U
VSK-S2-15U
VSK-S2-24U
220 μF
220 μF
120 μF
120 μF
120 μF
68 μF
0.1 μF/50 V
0.1 μF/50 V
0.1 μF/50 V
0.1 μF/50 V
0.1 μF/50 V
0.1 μF/50 V
P4KE6.8A
P4KE6.8A
P4KE12A
P4KE20A
P4KE20A
P4KE30A
Notes: 1. Output filtering capacitor C1 is an electrolytic capacitor. It is recommended to use high frequency
and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer
to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C2 is ceramic
capacitor, it is used to filter high frequency noise. TVS is a recommended component to protect
post-circuits (if converter fails).
2. It is recommended to use a 2A/250V slow blow FUSE.
3. MOV is required to protect the device under surge. Varistor model: 561KD14
C3,C4: Y capacitor, recommended parameter 2,200~4,700pF/400V;
C5: X capacitor, recommended parameter 0.1~0.33ꢀF/300V;
NF: common model choke, recommended inductance is about 15mH~30mH.
REVISION HISTORY
rev.
description
date
1.0
initial release
updated features
04/19/2012
06/04/2012
08/16/2012
1.01
1.02
V-Infinity branding removed
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明