SERIES: VSK-S2 DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• up to 2 W continuous power  
• compact board mount design  
• universal input (85~305 Vac / 120~430 Vdc)  
• single output from 3.3~24 V  
• over current and short circuit protection  
• UL/cUL and CE safety approvals  
• efficiency up to 78%  
RoHS  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efciency  
MODEL  
and noise1  
max  
typ  
(Vdc)  
3.3  
5
(A)  
(W)  
(mVp-p)  
(%)  
VSK-S2-3R3U  
VSK-S2-5U  
VSK-S2-9U  
VSK-S2-12U  
VSK-S2-15U  
VSK-S2-24U  
0.6  
2
2
2
2
2
2
200  
200  
200  
200  
200  
200  
65  
70  
72  
76  
76  
78  
0.4  
9
0.222  
0.167  
0.133  
0.083  
12  
15  
24  
Notes:  
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors.  
2. All specications are measured at rated input voltage, rated output load, TA=25°C, and humidity < 75% unless otherwise specied  
PART NUMBER KEY  
VSK-S2 - XX U  
Base Number  
Output Voltage  
cui.com  
CUI Inc SERIES: VSK-S2 DESCRIPTION: AC-DC POWER SUPPLY  
date 08/16/2012 page 2 of 4  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
120  
305  
430  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 110 Vac  
at 230 Vac  
44  
25  
mA  
mA  
at 110 Vac  
at 230 Vac  
5
11  
A
A
inrush current  
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
±2  
units  
%
line regulation  
load regulation  
ripple and noise  
10 ~ 100%  
±5  
%
mVp-p  
100  
200  
3.3 V model  
all other models  
±6  
±5  
%
%
voltage accuracy  
switching frequency  
100  
kHz  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
typ  
max  
units  
over current protection  
short circuit protection  
110  
%
auto recovery with no damage from a short on any output  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
for 1 minute  
min  
max  
units  
isolation voltage  
safety approvals  
safety class  
3,000  
Vac  
UL 60950-1, EN 60950-1/IEC 60950-1  
class II  
EMI/EMC  
EN 55022 Class B, IEC/EN 61000-4-(2,3,4,5,6)  
leakage current  
RoHS compliant  
MTBF  
0.15  
mA  
hrs  
yes  
25°C  
300,000  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-25  
-40  
30  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
storage humidity  
85  
°C  
non-condensing  
90  
%
20  
95  
%
cui.com  
CUI Inc SERIES: VSK-S2 DESCRIPTION: AC-DC POWER SUPPLY  
date 08/16/2012 page 3 of 4  
DERATING CURVES  
1. output power vs. ambient  
temperature  
2. efciency vs. output power  
(Vin=220Vac)  
3. efciency vs. input voltage  
(load=100%)  
80  
75  
70  
80  
75  
70  
65  
60  
65  
60  
100  
80  
60  
55  
55  
50  
45  
40  
20  
50  
45  
40  
-40  
-20  
0
20  
40  
55  
70 80  
100  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
85  
120  
220  
Load (%)  
240  
264  
305  
Ambient Temperature (°C)  
Input Voltage (Vac)  
MECHANICAL  
parameter  
dimensions  
conditions/description  
min  
typ  
max  
units  
1.327 x 0.874 x 0.708 (33.70 x 22.20 x 18.00 mm)  
UL94V-0  
inch  
case material  
weight  
20  
g
MECHANICAL DRAWING  
units: mm [inches]  
tolerance: ±0.5 [±0.02]  
pin section tolerance: ±0.10 mm [±0.004]  
PIN CONNECTIONS  
PIN  
1
FUNTION  
AC(N)  
AC(L)  
-Vo  
(Front view)  
2
3
4
+Vo  
ꢃꢂꢅꢃ>ꢃꢂꢃꢆꢉ@  
ꢀꢁꢂꢃꢃ  
>ꢃꢂꢄꢃꢈ@  
ꢇꢇꢂꢄꢃ>ꢀꢂꢇꢆꢄ@  
1.10[0.43]  
ꢇꢇꢂꢄꢃ>ꢀꢂꢇꢆꢄ@  
2
1
2
3
4
(Side view)  
(Bottom view)  
4
1
3
ꢆꢁꢂꢃꢃ>ꢀꢂꢀꢃꢆ@  
ꢆꢁꢂꢃꢃ>ꢀꢂꢀꢃꢆ@  
cui.com  
CUI Inc SERIES: VSK-S2 DESCRIPTION: AC-DC POWER SUPPLY  
date 08/16/2012 page 4 of 4  
TYPICAL APPLICATION CIRCUIT  
FUSE NTC  
C1  
C2  
TVS  
+Vo  
-Vo  
L
L
C3  
NF  
+
C5  
RL  
MOV  
C4  
N
N
EXTERNAL CAPACITORS TYPICAL VALUE (Unit: μF)  
MODEL  
C1  
C2  
TVS  
VSK-S2-3R3U  
VSK-S2-5U  
VSK-S2-9U  
VSK-S2-12U  
VSK-S2-15U  
VSK-S2-24U  
220 μF  
220 μF  
120 μF  
120 μF  
120 μF  
68 μF  
0.1 μF/50 V  
0.1 μF/50 V  
0.1 μF/50 V  
0.1 μF/50 V  
0.1 μF/50 V  
0.1 μF/50 V  
P4KE6.8A  
P4KE6.8A  
P4KE12A  
P4KE20A  
P4KE20A  
P4KE30A  
Notes: 1. Output ltering capacitor C1 is an electrolytic capacitor. It is recommended to use high frequency  
and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer  
to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C2 is ceramic  
capacitor, it is used to lter high frequency noise. TVS is a recommended component to protect  
post-circuits (if converter fails).  
2. It is recommended to use a 2A/250V slow blow FUSE.  
3. MOV is required to protect the device under surge. Varistor model: 561KD14  
C3,C4: Y capacitor, recommended parameter 2,200~4,700pF/400V;  
C5: X capacitor, recommended parameter 0.1~0.33F/300V;  
NF: common model choke, recommended inductance is about 15mH~30mH.  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
updated features  
04/19/2012  
06/04/2012  
08/16/2012  
1.01  
1.02  
V-Innity branding removed  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

VSK-S2-24U

AC-DC POWER SUPPLY
CUI

VSK-S2-3R3U

SERIES: VSK-S2 DESCRIPTION: AC-DC POWER SUPPLY
CUI

VSK-S2-5U

AC-DC POWER SUPPLY
CUI

VSK-S2-9U

SERIES: VSK-S2 DESCRIPTION: AC-DC POWER SUPPLY
CUI

VSK-S20

AC-DC POWER SUPPLY
CUI

VSK-S20-12U

AC-DC POWER SUPPLY
CUI

VSK-S20-12U-T

AC-DC POWER SUPPLY
CUI

VSK-S20-15U

AC-DC POWER SUPPLY
CUI

VSK-S20-15U-T

AC-DC POWER SUPPLY
CUI

VSK-S20-24U

AC-DC POWER SUPPLY
CUI

VSK-S20-24U-T

AC-DC POWER SUPPLY
CUI

VSK-S20-3R3U

AC-DC POWER SUPPLY
CUI