VSK-S25-12U-T [CUI]

AC-DC POWER SUPPLY up to 25 W continuous output; AC-DC电源提供高达25 W的连续输出
VSK-S25-12U-T
型号: VSK-S25-12U-T
厂家: CUI INC    CUI INC
描述:

AC-DC POWER SUPPLY up to 25 W continuous output
AC-DC电源提供高达25 W的连续输出

文件: 总5页 (文件大小:224K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
date 09/06/2012  
page 1 of 5  
SERIES: VSK-S25-T DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• up to 25 W continuous output  
• encapsulated compact case  
• output short circuit protection  
• over current protection  
• thermal protection  
• CE, UL safety approval  
• regulated output  
• universal input (85~264 Vac)  
• efficiency up to 87%  
RoHS  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
and noise  
efciency  
MODEL  
max  
max  
(Vdc)  
5
(A)  
(W)  
(mVp-p)  
(%)  
VSK-S25-5U-T  
VSK-S25-9U-T  
VSK-S25-12U-T  
VSK-S25-15U-T  
VSK-S25-24U-T  
VSK-S25-48U-T  
4.1  
2.5  
2.1  
1.6  
1.1  
0.5  
20.5  
22.5  
25.2  
24  
100  
100  
100  
100  
100  
100  
74  
78  
82  
83  
85  
87  
9
12  
15  
24  
48  
26.4  
24  
PART NUMBER KEY  
VSK-S25- XX U-T  
Base Number  
Output Voltage  
example of 25 W, single output  
cui.com  
CUI Inc SERIES: VSK-S25-T DESCRIPTION: AC-DC POWER SUPPLY  
date 09/06/2012 page 2 of 5  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
120  
264  
370  
Vac  
Vdc  
voltage  
frequency  
input current  
47  
63  
Hz  
at 110 Vac  
at 230 Vac  
420  
230  
mA  
mA  
at 110 Vac  
at 230 Vac  
16  
30  
A
A
inrush current  
recommended external input  
fuse  
3.15 A / 250 V, slow-blow type  
OUTPUT  
parameter  
conditions/description  
min  
typ  
±2  
max  
units  
%
voltage set accuracy  
line regulation  
±0.5  
±1  
%
load regulation  
minimum load  
at 10~100% load  
at 230 Vac  
%
0
%
hold-up time  
80  
0.02  
65  
ms  
temperature coefcient  
switching frequency  
%/°C  
kHz  
PROTECTIONS  
parameter  
conditions/description  
5 V model  
9 V model  
12 and 15 V models  
24 V model  
48 V model  
7.5  
12  
20  
30  
60  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
over voltage protection  
overload protection  
110  
%
short circuit protection  
shutdown and auto restart  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
isolation voltage  
safety approvals  
safety class  
for 1 minute  
3,000  
Vac  
CISPR22/EN 60950-1, IEC 60950-1, UL 60950-1  
Class I  
EMI/EMC  
EN 55022 class B, IEC/EN 61000-4-(2, 3, 4, 5)  
leakage current  
MTBF  
at 230 Vac, 50 Hz  
at 25°C, max. load  
yes  
0.3  
mA  
300,000  
hours  
RoHS compliant  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-40  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
case temperature  
humidity  
105  
90  
°C  
°C  
non-condensing  
85  
%
cui.com  
CUI Inc SERIES: VSK-S25-T DESCRIPTION: AC-DC POWER SUPPLY  
date 09/06/2012 page 3 of 5  
DERATING CURVES  
1. output power vs. ambient temperature  
2. output power vs. input voltage  
100  
80  
100  
80  
60  
50  
40  
60  
50  
40  
20  
20  
-40  
-30  
-20  
-10  
0
10  
50  
60  
70  
70  
85  
110  
125  
210  
225  
240  
264  
Ambient Temperature (°C)  
Input Voltage (Vac)  
*Note: When input DC, Vdc=1.414 x Vac - 20  
MECHANICAL  
parameter  
dimensions  
weight  
conditions/description  
min  
typ  
max  
units  
inch  
g
3.783 x 2.126 x 1.26 (96.1 x 54 x 32 mm)  
170  
MECHANICAL DRAWING  
units: mm [inches]  
tolerance: ±0.50 [±0.020]  
ꢆꢁꢂꢃꢄ>ꢅꢂꢇꢀꢅ@  
ꢌ ꢅꢂꢊꢄ>ꢄꢂꢃꢅꢀ@  
ꢀꢁꢂꢃꢄ>ꢅꢂꢅꢆꢄ@  
ꢅꢋ  
TopViewꢎ  
PIN CONNECTIONS  
PIN FUNCTION  
1
GND  
AC(N)  
AC(L)  
-Vo  
2
3
4
5
6
7
8
SideViewꢎ  
NC  
TRIM  
NC  
ꢀꢂꢊꢄ>ꢄꢂꢅꢅꢊ@  
ꢋꢄꢂꢁꢄ>ꢄꢂꢀꢃꢃ@  
+Vo  
cui.com  
CUI Inc SERIES: VSK-S25-T DESCRIPTION: AC-DC POWER SUPPLY  
date 09/06/2012 page 4 of 5  
TYPICAL APPLICATION CIRCUIT  
EXTERNAL CAPACITORS  
TYPICAL VALUE Unit: µF)  
EMC Filter (see note 3)  
NTC  
FUSE  
(
C1 C2 TVS1 RL  
+V o  
-Vo  
L
L
MODEL  
C1  
330  
330  
330  
330  
120  
68  
FUSE NTC  
L
L
C7  
C8  
VSK-S25-5U-T  
VSK-S25-9U-T  
VSK-S25-12U-T  
VSK-S25-15U-T  
VSK-S25-24U-T  
VSK-S25-48U-T  
NF  
N
N
C9  
MOV  
LOAD  
N
N
Notes:  
1. Output ltering capacitors C1, C2 and C3 are electrolytic capacitors, It is recommended to use high frequency and low impedance electrolytic capacitors. For  
capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. TVS is recommended component  
to protect post-circuits (if converter fails).  
2. 0.1 μF is recommended for C1.  
3. If a higher requirement to EMC performance is required it is recommended to add and ”EMC lter” at the input end, recommended parameter are as follows:  
MOV: Varistor is used to protect the device under surge.  
C7,C8:Y capacitor, recommended parameter 2200pF/400V;  
C9:X capacitor, recommended parameter 0.1F/275V;  
NF: common model choke, recommended inductance is about 10mH-30mH.  
PARALLEL LINES  
Copper Sheet  
Fuse  
L
3
2
+Vo  
-Vo  
C1  
Connect  
Oscillograph Probe  
C2  
Load  
VSK  
N
25.4mm  
25.4mm  
C1:10µF  
C2:0.1µF  
TRIM APPLICATION AND CALCULATION  
cui.com  
CUI Inc SERIES: VSK-S25-T DESCRIPTION: AC-DC POWER SUPPLY  
date 09/06/2012 page 5 of 5  
REVISION HISTORY  
rev.  
description  
initial release  
date  
1.0  
09/06/2012  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

VSK-S25-15U

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-15U-T

AC-DC POWER SUPPLY up to 25 W continuous output

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-24U

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-24U-T

AC-DC POWER SUPPLY up to 25 W continuous output

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-48U

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-48U-T

AC-DC POWER SUPPLY up to 25 W continuous output

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-5U

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-5U-T

AC-DC POWER SUPPLY up to 25 W continuous output

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-9U

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-9U-T

AC-DC POWER SUPPLY up to 25 W continuous output

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25-T

AC-DC POWER SUPPLY up to 25 W continuous output

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI

VSK-S25_15

AC-DC POWER SUPPLY

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI