VSK-S3 [CUI]
AC-DC POWER SUPPLY; AC- DC电源供应器型号: | VSK-S3 |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总4页 (文件大小:196K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
date 08/15/2012
page 1 of 4
SERIES: VSK-S3 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 3 W continuous power
• compact board mount design
• universal input (85~264 Vac / 110~370 Vdc)
• single output from 3.3~24 V
• over voltage, over temperature, and short circuit protections
• UL/cUL safety approvals
• efficiency up to 78%
RoHS
output
voltage
output
current
max
(A)
output
power
max
(W)
ripple
efficiency
MODEL
and noise1
typ
(mVp-p)
typ
(%)
(Vdc)
3.3
5
VSK-S3-3R3U
VSK-S3-5U
VSK-S3-9U
VSK-S3-12U
VSK-S3-15U
VSK-S3-24U
0.7
0.6
2.3
3
30
30
30
30
30
30
63
72
74
76
76
78
9
0.33
0.25
0.2
3
12
15
24
3
3
0.125
3
Notes:
1. Ripple and noise measured at 20 MHz bandwidth
PART NUMBER KEY
VSK-S3 - XXU
Base Number
Output Voltage
cui.com
CUI Inc │ SERIES: VSK-S3 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/15/2012 │ page 2 of 4
INPUT
parameter
conditions/description
min
typ
max
units
85
110
264
370
Vac
Vdc
voltage
frequency
current
47
440
Hz
at 110 Vac
at 230 Vac
65
30
mA
mA
at 110 Vac
at 230 Vac
10
20
A
A
inrush current
external input fuse
(recommended)
slow blow, 250 V
0.5
A
OUTPUT
parameter
conditions/description
10 ~ 100%
min
typ
±0.5
±1
max
units
%
line regulation
load regulation
temperature coefficient
hold-up time
%
0.02
50
%/°C
ms
at 230 Vac
3.3 V model
all other models
±3
±2
%
%
voltage accuracy
switching frequency
100
kHz
units
°C
PROTECTIONS
parameter
conditions/description
min
typ
max
150
over voltage protection
short circuit protection
over temperature protection
chip lock up
auto recovery with no damage from a short on any output
SAFETY & COMPLIANCE
parameter
conditions/description
primary to secondary (for 1 minute)
IEC 60950-1, EN 60950-1, UL 60950-1
class II
min
3,000
typ
max
units
isolation voltage
Vac
safety approvals
safety class
EN 55022 (level A), IEC/EN 61000-4-2 (level 4, 8kV/15kV), IEC/EN 61000-4-3, IEC/EN 61000-4-4
(level 3, 2kV), IEC/EN 61000-4-5 (level 3, 1kV/2kV)
EMI/EMC
RoHS compliant
MTBF
yes
25°C
300,000
hrs
ENVIRONMENTAL
parameter
conditions/description
min
-25
-40
typ
max
70
units
°C
operating temperature
storage temperature
case temperature
operating humidity
105
95
°C
°C
non-condensing
95
%
cui.com
CUI Inc │ SERIES: VSK-S3 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/15/2012 │ page 3 of 4
DERATING CURVES
1. output power vs. ambient temperature
2. output power vs. input voltage
100
80
100
80
60
50
40
60
50
40
20
20
-40
-30 -25 -20
-10
0
10
50
60
70
70
85
110
125
210
225
240
264
Ambient Temperature (°C)
Input Voltage (Vac)
MECHANICAL
parameter
dimensions
conditions/description
1.457 x 0.908 x 0.591 (37.0 x 23.0 x 15.0 mm)
UL94V-0
min
typ
max
units
inch
case material
weight
25
g
MECHANICAL DRAWING
units: mm [inches]
tolerance: ±0.5 [±0.02]
pin section tolerance: ±0.10 [±0.004]
PIN CONNECTIONS
PIN
1
FUNCTION
L
N
37.00 1.457
3
13
14
16
22
N/C
0V
15.00 0.591
+Vo
+Vin(DC)
26
-Vin(DC)
4.10 0.161
0.80 0.031
(7 PLCS)
(TYP)
3.26 0.128
(2 PLCS)
2.61 0.103
(TYP)
8.34 0.328
2.54
1
3
13
14
1.2 0.047
(7 PLCS)
26
22
16
14
13
23.00 0.906
17.78 0.700
26
22
16
1
3
5.08 0.200
(TYP)
3.26 0.128
(2 PLCS)
BOTTOM VIEW
RECOMMENDED FOOTPRINT
TOP VIEW
13.42 0.528
cui.com
CUI Inc │ SERIES: VSK-S3 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/15/2012 │ page 4 of 4
TYPICAL APPLICATION CIRCUIT
* NTC
*F USE *NT C
* FUSE
C2 Tvs
C1
C1 C2 Tvs
+V0
L
L
L
L
+V0
C7
C8
NF
C3
+
C3
+
+
22
26
22
26
RL
+
C6
R L
MOV
MOV
-V0
-V0
N
N
N
N
Figure1
Figure 2 VSK-S3 EMC Filtering Circuit
EXTERNAL CAPACITORS TYPICAL VALUE (Unit: μF)
MODEL
C1
C2
0.1
0.1
0.1
0.1
0.1
0.1
C3
TVS
VSK-S3-3R3U
VSK-S3-5U
VSK-S3-9U
VSK-S3-12U
VSK-S3-15U
VSK-S3-24U
150
150
150
150
150
150
4.7/400V
4.7/400V
4.7/400V
4.7/400V
4.7/400V
4.7/400V
P4KE6.8A
P4KE6.8A
P4KE12A
P4KE20A
P4KE20A
P4KE30A
Notes:
1. Output filtering capacitors C1, C3 is electrolytic capacitors, It is recommended to use high frequency
and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to
manufacture’s datasheet. Voltage derating of apacitor should be 80% or above. C2, C4 is ceramic
capacitors , it is used to filter high frequency noise. TVS is a recommended component to protect
post-circuits (when converter fails).
2. MOV is required for VSK-S3 models. Model: 471KD05, it is used to protect the device under surge.
3. It is recommended to connect FUSE, the parameter is 0.5A/250V slow blow. External input NTC is
recommended to use D -14 or 10Ω/2W wire-round resistor.
4. If EMC performance is required, recommended to add “EMC filter” at the input end(see figure 2)
C6:X capacitor, recommended parameter 0.1uF/275V; C7,C8:Y capacitor, recommended parameter
220pF/275V; NF: common model choke, recommended inductance is about 10mH-30mH.
5. Terminals 22 and 26 are internal rectification and filtering terminals. To protect the models further, it
is recommended to connect an electrolytic capacitor C3 (it is recommended to be 4.7uF/400V). If
operation voltage of the module is between 160~264VAC, C3 can be removed.
REVISION HISTORY
rev.
description
date
1.0
initial release
02/27/2009
04/10/2012
08/15/2012
1.01
1.02
new template applied
V-Infinity branding removed
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号: