VSUU-150-48 [CUI]
AC-DC POWER SUPPLY;型号: | VSUU-150-48 |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总4页 (文件大小:361K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date 02/12/2013
page 1 of 4
SERIES: VSUU-150 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• wide input voltage range: 90~264 V ac, 47~63 Hz
• internal EMI filter
• single output
• input connector mates with Molex housing 09-50-3051
and Molex 2478 series crimp terminal
• output connector mates with Molex housing 09-50-3061
(or 09-50-3081) and Molex 2478 series crimp terminal
• output voltage available from 9 to 48 V dc
• input surge current and over load protection
• over voltage protection (crowbar design)
• size: 3 x 5 x 1.09 inches
• class I insulation
• 2 year warranty
RoHS
output
voltage
output
current
max
(A)
output
power
max
(W)
ripple and
noise
max
(mVp-p)
efficiency
MODEL
typ
(%)
(Vdc)
9
VSUU-150-9
VSUU-150-12
VSUU-150-15
VSUU-150-18
VSUU-150-24
VSUU-150-30
VSUU-150-36
VSUU-150-48
16
12.5
10
144
150
150
150
150
150
150
150
90
80
80
80
80
80
80
80
80
12
15
18
24
30
36
48
120
150
180
240
300
360
480
8.33
6.25
5
4.17
3.13
PART NUMBER KEY
VSBU-150 - XX - X
Base Number
Output Voltage
Power Fail Detect
“Blank” = No
P = Yes
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUU-150 │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/12/2013 │ page 2 of 4
INPUT
parameter
voltage
conditions/description
min
90
typ
max
264
63
units
Vac
frequency
47
Hz
at 115 Vac, full load
at 230 Vac, full load
2.0
0.8
A
A
current
at 115 Vac, 25°C, full load, cold start
at 230 Vac, 25°C, full load, cold start
16
56
20
63
A
A
inrush current
power factor correction
full load at 90 ~ 240 Vac
0.95
min
0.97
1.0
OUTPUT
parameter
conditions/description
full load
typ
0.5
3
max
units
%
line regulation
load regulation
temperature coefficient
transient response
start-up
1
5
at 230 Vac
%
all output
-0.04
0.04
4
%/°C
ms
s
full load to half load at 100 Vac
full load at 100 Vac
full load at 110 Vac
0.3
16
1
2
hold-up
ms
PROTECTIONS
parameter
conditions/description
min
112
110
typ
max
132
150
units
%
over voltage protection
over current protection
%
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
primary to secondary
primary to earth ground
4,242
2,121
Vdc
Vdc
isolation voltage
isolation resistance
safety approvals
EMI/EMC
test voltage of 500 Vdc
50
MΩ
UL/cUL, TUV-Baurart, CE, CISPR-22 class B, FCC part 15 class B, CB
CISPR 22 class B, FCC part-15 class B
leakage current
RoHS compliant
MTBF
full load at 240 Vac
yes
0.4
0.75
mA
hrs
100,000
ENVIRONMENTAL
parameter
conditions/description
min
0
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
-40
5
85
°C
95
%
5
95
%
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUU-150 │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/12/2013 │ page 3 of 4
DERATING CURVES
output power vs. ambient temperature
100
80
60
50
40
20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
MECHANICAL DRAWING
CN2
1
2
V1
V1
3
V1
4
V1
5
V1
6
V1
7
com
com
com
com
com
com
n/c
8
9
10
11
12
13
*pin 13 for optional
power fail detect
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUU-150 │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/12/2013 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
11/19/2010
07/13/2011
08/22/2012
02/12/2013
1.01
1.02
1.03
new template applied
V-Infinity branding removed
updated derating curve
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明