VWRAT2-D12-D5-SMT [CUI]
dc-dc converter; DC-DC变换器型号: | VWRAT2-D12-D5-SMT |
厂家: | CUI INC |
描述: | dc-dc converter |
文件: | 总3页 (文件大小:245K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
page
1 of 3
date 05/2010
PART NUMBER: VWRAT2
DESCRIPTION: dc-dc converter
description
features
Designed to convert a wide input
voltage range into an isolated
regulated voltage, the
·wide (2:1) input range
·regulated
·dual voltage output
·I/O isolation: 1500 V dc
·no heatsink required
·short circuit protection
·MTBF >1,000,000 hours
VWRAT2-SMT series is well
suited for providing board-mount
local supplies in a wide range of
applications, including mixed
analog/digital circuits, test &
measurement equip.,
·temperature range: -40°C~+85°C
process/machine controls,
datacom/telecom fields, etc...
MODEL
input voltage
output voltage
(V dc)
output current
efficiency
typ.
nominal
(V dc)
range
(V dc)
max.
max.
min.
(mA)
(V dc)
(mA)
200
111
83
(%)
76
78
80
79
77
79
80
79
VWRAT2-D12-D5-SMT
VWRAT2-D12-D9-SMT
VWRAT2-D12-D12-SMT
VWRAT2-D12-D15-SMT
VWRAT2-D24-D5-SMT
VWRAT2-D24-D9-SMT
VWRAT2-D24-D12-SMT
VWRAT2-D24-D15-SMT
12
12
12
12
24
24
24
24
9.0~18.0
9.0~18.0
9.0~18.0
9.0~18.0
18.0~36.0
18.0~36.0
18.0~36.0
18.0~36.0
22
22
22
22
40
40
40
40
5
9
12
15
5
9
12
15
20
11
8
67
7
200
111
83
20
11
8
67
7
notes:
1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless otherwise specified.
INPUT
parameter
conditions/description
conditions/description
min
12
24
nom
9~18
18~36
max
22
40
units
V dc
V dc
input voltage range
OUTPUT
parameter
min
0.2
nom
max
2
2
units
W
%
2W output power
voltage accuracy
ripple & noise
refer to recommended circuit
@ 20MHz Bandwidth
1
35
75
mVpp
line regulation
input voltage from low to high
10% to 100% full load
refer to recommended circuit
100% load, nominal input
0.2
0.5
0.5
1.0
0.03
%
%
%/°C
KHz
load regulation
temperature coefficient
switching frequency
300
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-
date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
th
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com
page
2 of 3
date 05/2010
PART NUMBER: VWRAT2
DESCRIPTION: dc-dc converter
GENERAL SPECIFICATIONS
parameter
conditions/description
output short circuit protection
temperature rise at full load
cooling
operating temp. range
storage temp. range
reflow soldering temp.
storage humidity range
MTBF
Hiccup, automatic recovery
15°C typ., 35°C max.
free air convection
-40°C ~ +85°C
-55°C ~ +125°C
245°C (for 10 seconds)
≤95%
>1,000,000 hours
ISOLATION SPECIFICATIONS
parameter
conditions/description
min
1500
1000
nom
max
units
V dc
MΩ
isolation voltage
isolation resistance
isolation capacitance
flash tested for 1 minute
test at 500 V dc
Input/Output
85
PF
OUTLINE DIMENSIONS & FOOTPRINT
FOOTPRINT DETAILS
Pin
(Side View)
9
8
16
1
10
7
-Vin
NC
1
7
1.02[0.040]
0.50[0.020]
8
0V
+Vo
9
23.86[0.939]
15.24[0.600]
10
-Vo
3.04[0.120]
2.54[0.100]
+Vin
16
NC: No connection
2.54[0.100]
1.00[0.039]
9
8
16
10
7
(Top View)
1
Note:
Unit:mm[inch]
Pin section tolerances: 0.10mm[ 0.004inch]
General tolerances: 0.25mm[ 0.010inch]
0.25[0.010]
1.40 0.20
[0.055 0.008]
18.10[0.713]
RECOMMENDED REFLOW PROFILE
th
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com
page
date 05/2010
3 of 3
PART NUMBER: VWRAT2
DESCRIPTION: dc-dc converter
- Input current
Application Notes:
Nominal input voltage range. The input
current of the power supply must be sufficient
to the startup current (Ip) of the DC/DC module
(Figure 2)
- All of the VWRAT2-SMT Series have been tested
according to the following recommended testing
circuit before leaving the factory. This series should
be tested under load (Figure 1). If you want to
further decrease the input/output ripple, you can
increase capacitance properly or choose capacitors
with low ESR. However, the capacitance should not
be too high(Table 1).
Figure 2
Figure 1
+Vout
+Vin
-Vin
Cout
Cout
Cin
Com
- Output Load
DC DC
In order to ensure the product operates
efficiently and reliably, make sure the specified range
of input voltage is not exceeded.
-Vout
- Recommended circuit
No parallel connection or plug and play.
It is best to test with full load and not to test without load. To
further reduce output ripple, you may increase the external
capacitor, choose a capacitor with low ESR, or add external
inductor to the circuit as shown above.
- NC Terminals
Unless otherwise specified, NC terminals of all series
are used for converter's interior circuit
connection, and are not allowed connection of any
external circuit.
General:
Cin: 12V 100μF
24V 10μF to 47μF
Cout:see Table 1
Temperature Derating Curve
Table 1
Dual
Vout
(VDC)
Cout
(uF)
5
560
470
330
220
9
12
15
th
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com
相关型号: