VYC30W-Q48-S12-T [CUI]
DC-DC CONVERTER;型号: | VYC30W-Q48-S12-T |
厂家: | CUI INC |
描述: | DC-DC CONVERTER DC-DC转换器 |
文件: | 总6页 (文件大小:379K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date 08/31/2012
page 1 of 6
SERIES: VYC30W-T │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• chassis mount with screw terminal connectors
• up to 30 W output
• compact size
• 4:1 input range (9~36 V, 18~75 V)
• single and dual outputs
• 1,500 V isolation
• short circuit, over current, and over voltage protection
• wide temperature operation (-40~85°C)
• efficiency up to 88%
RoHS
input
voltage
range
output
voltage
outu
current
max
tput
poer
max
ripple and
noise1
efficiency
MODEL
max
typ
(Vdc)
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
VYC30W-Q24-S5-T
VYC30W-Q24-S12-T
VYC30W-Q24-S15-T
VYC30W-Q24-D5-T
VYC30W-Q24-D12-T
VYC30W-Q24-D15-T
VYC30W-Q48-S5-T
VYC30W-Q48-S12-T
VYC30W-Q48-S15-T
VYC30W-Q48-D5-T
VYC30W-Q48-D12-T
VYC30W-Q48-D15-T
9 ~ 36
9 ~ 36
6
5
2
30
30
30
30
30
30
30
30
30
30
30
30
120
120
120
120
120
120
120
120
120
120
120
120
87
88
87
86
88
87
87
88
87
86
88
87
12
9 ~ 36
15
9 ~ 36
±5
±12
15
5
±3
±1.25
±1
6
9 ~ 36
9 ~ 36
18 ~ 75
18 ~
18 ~
18 ~
18 ~ 75
18 ~ 75
12
2.5
2
5
±5
±12
±15
±3
±1.25
±1
Notes:
1. Ripple and noise are meaed at 20 MHz BW wh 10μF tantalum capacitor and 1μF ceramic capacitor across output
PART NUMBER KEY
VYC30W - QXX - X XX - X - T
Base Number
Output
S = single output
D = dual output
Heatsink
"blank" = No
H = Yes
Input Voltage
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VYC30W-T │ DESCRIPTION: DC-DC CONVERTER
date 08/31/2012 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
9
18
24
48
36
75
operating input voltage
start-up time
10
power up 24 V input
.0
17.8
V
Vdc
power up 48 V input
power down 24 V input
power down 48 V input
under voltage lockout
8
16.0
module off
module on (or open circuit)
0
3.5
.2
2
Vdc
Vdc
Remote on/off1
filter
PI type
Notes:
1. The on/off pin voltage is referenced to GND
OUTPUT
parameter
conditions/description
min
typ
0.2
±0.5
±1
max
±0.5
±1
units
%
line regulation
measured from low line to high line
measured from 10% to full load
refer to recommended circuit
25% step load charge
load regulation
%
voltage accuracy
transient recovery time
transient peak deviation
±3
%
300
300
500
μs
25% rated load
μs
main outut 50%
supplemental outpfrom
10~10% load
±5
%
cross regulation
dual output models
adjustability
±10%
400
Vdc
kHz
switching frequency
temperature coefficient
100% load, input vogange
±0.02
%/°C
PROTECTIONS
parameter
conditi
min
typ
max
units
short circuit protection
over current protection
hiccups, ry
all models
nput voltage range
130
%
5 V
12 V
15 V
6.1
15
18
Vdc
Vdc
Vdc
single and dual
output modes
over voltage protection
SAFETY AND COMPLIANCE
parameter
conditions/description
min
typ
max
units
Vdc
MΩ
isolation voage
isolation retance
isolation capacnce
Rmpliant
tested for 1 minute at 1 mA max.
at 500 Vdc
1,500
1,000
input to output, 100 kHz / 0.1 V
yes
2,000
pF
M1L-HDBK-217F
1,000,000
hours
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VYC30W-T │ DESCRIPTION: DC-DC CONVERTER
date 08/31/2012 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
during operation
min
typ
max
85
units
case operating temperature
maximum case temperature
storage temperature
storage humidity
-40
105
125
95
-40
5
non-condensing
DERATING CURVES
output power vs. ambient temperature
100
80
2
2
Vo ≤ 5
Vo > 5
1
60
40
20
0
55 60
85
-40
Ambient Teperature (°C)
MECHANICAL
parameter
dimensions
conditioon
min
typ
max
units
2.17 x 255.0 x 67.5 x 19.1 mm)
aluminu
case material
weight
83.5
g
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VYC30W-T │ DESCRIPTION: DC-DC CONVERTER
date 08/31/2012 │ page 4 of 6
MECHANICAL DRAWING
20.32 0.800
0.010 (2 PLCS)
4.75 0.187
(2 PLCS)
3.51 0.138
(2 PLCS)
2.01 X 3.99
[0.079 X 0.157]
(2 PLCS)
34.01 1.339
50.11 1.973
67.51 2.658
22.23 0.875
0.010
8
7
6
5
4
3
2
1
5.31 0.209
(5 PLCS)
5.05
(2 PLC
54.99 2.165
33.02 1.300
0.010 (2 PLCS)
0ꢀꢁ;ꢁꢂ
ꢃꢄꢁ3/&6ꢅ
10.99 0.4
0.010 (2 PLCS)
1.00 0.039
52.99 2.086
4.01 0.158
0.010 (TYP)
PIN CONNECTIONS
Pin
Single
+Vo
Dual
1
2
3
4
5
6
7
8
+Vo
0V
-Vo
Trim
-Vo
No Pin
Case
On/Off
GND
Vin
Trim
Case
On/Off
GND
Vin
Unit: mm[inch]
TOLERANCE: ±0.5mm [±0.020 inch] UNLESS OTHERWISE SPECIFIED
Screw terminals: Degson Electronics terminal block part number
DG301-5.0-04P-12 or equivalent (4 pin, M2.5 screw) 5.0 mm spacing
*DIN rail mounting kit available (part # STK-DIN)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VYC30W-T │ DESCRIPTION: DC-DC CONVERTER
date 08/31/2012 │ page 5 of 6
APPLICATION NOTES
1. EMI & EMS recommended external circuit
Single output, 18 ~ 75 Vin
SMCJ90A,1500W(Bringtking)
Single output, 9 ~ 36 Vin
Dual output, 18 ~ 75 Vin
Dual output, 9
TVS
LCM
SMCJ48A,1500W(Bringtking)
SMCJ90A,1500W(Bringtking) SMCJ48A,1500
232uH(0.1V 100KHz) 15T
core: N5 T12*6*4
232uH(0.1V 100KHz) 15T
core: N5 T12*6*4
232uH(0.1V 100KHz) 15T
core: N5 T12*6*4
232uH(0.V 100K
cor: N5 T12*6
C0
C1
C2
C3
C4
680ꢀF/1000V (CapXon)
105K/100V 1210(TDK)
225K/100V 1210(TDK)
No component
1000ꢀF/50V(CapXon)
105K/100V 1210(TDK)
225K/100V 1210(TDK)
No component
680ꢀF/100V (CapXon)
105K/100V 1210(TDK)
225K/100V 1210(TDK)
102K/2000V 1206 (TDK)
102K/2000V 1206 (TK)
100ꢀF/50VCapXon)
105/10V 1210(TDK)
225K/10V 1210(DK)
1K/200010 (TDK)
102K2000V 1206 (TDK)
No component
No component
Figure 1 (Single output)
C3
LCM
+INPUT
Vin
+Vo
0V
+C0
TVS
C1
C2
LOAD
GND
CASE
-INPUT
C
Figure 2 (Dual output)
C3
+Vo
0V
LCM
+INPUT
VIN
LOAD 1
LOAD 2
+C0
TVS
C1
C2
GND
-VO
CASE
C4
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VYC30W-T │ DESCRIPTION: DC-DC CONVERTER
date 08/31/2012 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
08/23/2011
03/08/012
08/9/2012
1.01
1.02
added VYC30W-Q24-D5-T and VYC30W-Q48-D5-T
V-Infinity branding removed
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号: