IWPTU Series
Industrial Wireless Pressure Transducer
Pressure ranges from -15 to +5800 psi gauge
Up to 2500ft line-of-site range (depending on receiver)
Piezo-resistive thick film ceramic sensor with stainless steel body
Five year battery life at 10 second transmission update rate
Simple DIL switch pairing with the single or five channel receiver
Single or five channel receivers available
User-selectable transmission update rates
User-selectable 1-5V or 4-20mA receiver outputs
Receiver clean contacts provide process alarm functions
DESCRIPTION
The IWPTU Wireless Pressure Transducer is a cost effective replacement to a traditionally
wired pressure transducer that offers the advantages of a low-cost installation in
inaccessible and expensive installation environments.
It is easily paired to the compatible IWR family of single- or five-channel wireless
receivers thus offering a “plug and play” solution to your pressure measurement
applications.
TYPICAL APPLICATIONS INCLUDE:-
- Simple cable replacement installation –
dispense with expensive cable runs
- Environmental monitoring – pumping stations,
sewage plants, water treatment
The instrument uses a piezo-resistive ceramic sensor mounted within a stainless steel
housing giving excellent media compatibility for the harshest of applications.
- Facilities management – boiler rooms, plant
hydraulics, plant pneumatics
- Asset monitoring – tanks farms, process
plants, HVAC and building management
- Service Contract – temporary installation for
servicing and field trials
A line-of-sight range of up to 2500ft is possible depending on the wireless receiver used
(refer to datasheets IWR-1 & IWR-5 for further information).
Each device is temperature compensated, calibrated and supplied with a traceable
serial number and calibration certificate.
Transmitter Pressure Ranges
Nominal Pressure, Gauge, psi
Compound range psi
Permissible Overpressure psi
15
-15 to 0 -15 to 30 -15 to 75 -15 to 1235 -15 to 285 -15 to 360
30
75
150
300
750
1500
3750
6000
30
60
75
150
180
300
375
600
750
1500
1800
3000
3750
6000
7500
9750
9750
Burst Pressure
psi
60
Transmitter Output
*Transmission Frequency
Transmit Power
System Performance
Accuracy (Non-Linearity & Hysteresis) < 0.25% / FS (BFSL)
2.4 Ghz
18 dBm
User selectable via DIL switch
Setting Errors (offsets)
Zero & Full Scale, < 0.5% / FS
System Channel
Antenna
Integral 0dBi
Instrument Power Source
Battery Type
Battery Life
*Compliant with EN 300 328, V1.8.1
User replaceable Lithium C cell
Five years at 10 second update
rate
10 years
Cynergy3 Components Ltd.
Ferndown Industrial Estate
7 Cobham Road
Wimborne, Dorset BH21 7PE
Battery Shelf Life
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
www.cynergy3.com
ISO9001CERTIFIED
IWPTU 2016
© 2016 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
IWPTU Series
Industrial Wireless Pressure Transducer
Material Specifications
Pressure Housing
“O” ring seals
Diaphragm
Wireless Enclosure Material Plastic
Temperatures & Thermal Effects
Media Temperature
Ambient Temperature
Storage Temperature
Thermal Zero Shift
303 Stainless Steel
Viton
Ceramic Al2O3 96%
-20ºC to +135ºC
-20ºC to +80ºC
-20ºC to +80ºC
< 0.04% /FS/ºC
< 0.02% /ºC typical
Weight
310g including battery
Thermal Span Shift
**Installation position
Any
** Consult installation manual to ensure adequate signal path between transmitter and receiver
Receiver Output Signals
Outputs
Single Channel Receiver
Five Channel receiver
Alarm Output
Mechanical Stability
See user manual
Ordering Codes:-
Pressure Transducer
1-5V or 4-20mA per channel
IWR-1 (see data sheet)
IWR-5 (see data sheet)
See table below
IBAT-1
IWR-1
IWR-5
IWR-Set
5 Amp rated changeover contacts
Spare battery
***Transmission Update Rate 1, 5, 10 and 30 seconds
Single Channel Receiver
Five Channel Receiver
Five Channel Configuration Software
*** Consult installation manual for set-up:
- single channel system is DIL switch configurable
- five channel system requires set-up using “IWR Set” user software
*Download user configuration software here: - www.cyneregy3.com/????????
Part Number
Pressure Rating Receiver Output
1-5Vdc or 4-20mA
1-5Vdc or 4-20mA
IWPTU-C0446-00 -14.5 to +150 psi G1-5Vdc or 4-20mA
IWPTU-GP075-00 0-75 psi G 1-5Vdc or 4-20mA
IWPTU-GP100-00 0-100 psi G 1-5Vdc or 4-20mA
IWPTU-C0447-00 -14.5 to +350 psi G1-5Vdc or 4-20mA
IWPTU-GP015-00 0-15 psi G
IWPTU-GP030-00 0-30 psi G
IWPTU-GP150-00 0-150 psi G
IWPTU-GP300-00 0-300 psi G
IWPTU-GP750-00 0-750 psi G
IWPTU-GP1K5-00 0-1500 psi G
IWPTU-GP3K6-00 0-3600 psi G
IWPTU-GP5K8-00 0-5800 psi G
1-5Vdc or 4-20mA
1-5Vdc or 4-20mA
1-5Vdc or 4-20mA
1-5Vdc or 4-20mA
1-5Vdc or 4-20mA
1-5Vdc or 4-20mA
Mechanical Dimensions
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
1/4" NPT
ISO9001CERTIFIED
© 2016 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.