CY7C09279V-9AI [CYPRESS]
3.3V 16K/32K/64K x 16/18 Synchronous Dual-Port Static RAM; 3.3V 16K / 32K / 64K X 16/18同步双端口静态RAM型号: | CY7C09279V-9AI |
厂家: | CYPRESS |
描述: | 3.3V 16K/32K/64K x 16/18 Synchronous Dual-Port Static RAM |
文件: | 总19页 (文件大小:348K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
25/0251
CY7C09269V/79V/89V
CY7C09369V/79V/89V
3.3V 16K/32K/64K x 16/18
Synchronous Dual-Port Static RAM
• High-speed clock to data access 6.5[1, 2]/7.5[2]/9/12 ns
(max.)
Features
• True Dual-Ported memory cells which allow simulta-
neous access of the same memory location
• 3.3V low operating power
—Active = 115 mA (typical)
• 6 Flow-Through/Pipelined devices
— 16K x 16/18 organization (CY7C09269V/369V)
— 32K x 16/18 organization (CY7C09279V/379V)
— 64K x 16/18 organization (CY7C09289V/389V)
• 3 Modes
—Standby = 10 µA (typical)
• Fully synchronous interface for easier operation
• Burst counters increment addresses internally
—Shorten cycle times
—Minimize bus noise
— Flow-Through
—Supported in Flow-Through and Pipelined modes
• Dual Chip Enables for easy depth expansion
• Upper and Lower Byte Controls for Bus Matching
• Automatic power-down
• Commercial and Industrial temperature ranges
• Available in 100-pin TQFP
— Pipelined
— Burst
• Pipelined output mode on both ports allows fast
100-MHz operation
• 0.35-micron CMOS for optimum speed/power
Logic Block Diagram
R/WL
UBL
R/WR
UBR
CE0L
CE0R
1
1
CE1L
LBL
CE1R
LBR
0
0
0/1
0/1
OEL
OER
1b 0b 1a 0a
0a 1a 0b 1b
0/1
0/1
b
a
a
b
FT/PipeL
FT/PipeR
8/9
8/9
8/9
8/9
[3]
[3]
I/O8/9L–I/O15/17L
I/O8/9R–I/O15/17R
I/O
Control
I/O
Control
[4]
[4]
I/O0L–I/O
I/O0R–I/O
7/8L
7/8R
14/15/16
14/15/16
[5]
[5]
A0L–A
A
–A
13/14/15L
0R
13/14/15R
CLKR
Counter/
Address
Register
Decode
Counter/
Address
Register
Decode
CLKL
ADSL
True Dual-Ported
RAM Array
ADSR
CNTENL
CNTENR
CNTRSTL
CNTRSTR
Notes:
1. Call for availability.
2. See page 6 for Load Conditions.
3. I/O8–I/O15 for x16 devices; I/O9–I/O17 for x18 devices.
4. I/O0–I/O7 for x16 devices. I/O0–I/O8 for x18 devices.
5. A0–A13 for 16K; A0–A14 for 32K; A0–A15 for 64K devices.
For the most recent information, visit the Cypress web site at www.cypress.com
Cypress Semiconductor Corporation
•
3901 North First Street
•
San Jose
•
CA 95134
•
408-943-2600
Document #: 38-06056 Rev. **
Revised September 21, 2001
CY7C09269V/79V/89V
CY7C09369V/79V/89V
A HIGH on CE0 or LOW on CE1 for one clock cycle will power
down the internal circuitry to reduce the static power consump-
tion. The use of multiple Chip Enables allows easier banking
of multiple chips for depth expansion configurations. In the
pipelined mode, one cycle is required with CE0 LOW and CE1
HIGH to reactivate the outputs.
Functional Description
The CY7C09269V/79V/89V and CY7C09369V/79V/89V are
high-speed 3.3V synchronous CMOS 16K, 32K, and 64K x
16/18 dual-port static RAMs. Two ports are provided, permit-
ting independent, simultaneous access for reads and writes to
any location in memory.[6] Registers on control, address, and
data lines allow for minimal set-up and hold times. In pipelined
output mode, data is registered for decreased cycle time.
Clock to data valid tCD2 = 6.5 ns[1, 2] (pipelined). Flow-through
mode can also be used to bypass the pipelined output register
to eliminate access latency. In flow-through mode data will be
available tCD1 = 18 ns after the address is clocked into the
device. Pipelined output or flow-through mode is selected via
the FT/Pipe pin.
Counter enable inputs are provided to stall the operation of the
address input and utilize the internal address generated by the
internal counter for fast interleaved memory applications. A
port’s burst counter is loaded with the port’s Address Strobe
(ADS). When the port’s Count Enable (CNTEN) is asserted,
the address counter will increment on each LOW to HIGH tran-
sition of that port’s clock signal. This will read/write one word
from/into each successive address location until CNTEN is
deasserted. The counter can address the entire memory array
and will loop back to the start. Counter Reset (CNTRST) is
used to reset the burst counter.
Each port contains a burst counter on the input address regis-
ter. The internal write pulse width is independent of the LOW
to HIGH transition of the clock signal. The internal write pulse
is self-timed to allow the shortest possible cycle times.
All parts are available in 100-pin Thin Quad Plastic Flatpack
(TQFP) packages.
Pin Configurations
100-Pin TQFP (Top View)
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76
A9L
A10L
A11L
A12L
A13L
A14L
A15L
NC
1
75
74
73
72
71
70
69
68
67
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
A9R
2
A10R
A11R
A12R
A13R
A14R
A15R
NC
3
4
5
[7]
[8]
[7]
[8]
6
7
8
NC
9
NC
LBL
10
11
12
13
14
15
16
17
18
19
20
21
22
23
LBR
UBL
UBR
CE0R
CE1R
CY7C09289V (64K x 16)
CY7C09279V (32K x 16)
CY7C09269V (16K x 16)
CE0L
CE1L
CNTRSTL
VCC
CNTRSTR
GND
R/WL
R/WR
OEL
OER
[9]
[9]
FT/PIPEL
GND
FT/PIPER
GND
I/O15L
I/O14L
I/O13L
I/O12L
I/O15R
I/O14R
I/O13R
I/O12R
I/O11R
I/O10R
I/O11L
I/O10L
24
25
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Notes:
6. When writing simultaneously to the same location, the final value cannot be guaranteed.
7. This pin is NC for CY7C09269V.
8. This pin is NC for CY7C09269V and CY7C09279V.
9. For CY7C09269V and CY7C09279V, pin #18 connected to VCC is pin compatible to an IDT 5V x16 pipelined device; connecting pin #18 and #58 to GND is pin
compatible to an IDT 5V x16 flow-through device.
Document #: 38-06056 Rev. **
Page 2 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Pin Configurations (continued)
100-Pin TQFP (Top View)
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76
A9L
A10L
A11L
A12L
A13L
A14L
A15L
LBL
1
75
74
73
72
71
70
69
68
67
66
65
64
63
62
61
60
59
58
57
56
55
54
53
A8R
2
A9R
3
A10R
A11R
A12R
A13R
A14R
A15R
LBR
4
5
[10]
[11]
6
[10]
[11]
7
8
UBL
9
CE0L
CE1L
10
11
12
13
14
15
16
17
18
19
20
21
22
23
UBR
CE0R
CE1R
CY7C09389V (64K x 18)
CY7C09379V (32K x 18)
CY7C09369V (16K x 18)
CNTRSTL
R/WL
CNTRSTR
R/WR
OEL
VCC
GND
FT/PIPEL
I/O17L
I/O16L
GND
OER
FT/PIPER
I/O17R
GND
I/O15L
I/O14L
I/O13L
1/012L
I/O16R
I/O15R
I/O14R
I/O13R
I/O11L
I/O10L
24
25
52
51
I/O12R
I/O11R
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Selection Guide
CY7C09269V/79V/89V CY7C09269V/79V/89V CY7C09269V/79V/89V CY7C09269V/79V/89V
CY7C09369V/79V/89V CY7C09369V/79V/89V CY7C09369V/79V/89V CY7C09369V/79V/89V
-6[1, 2]
100
-7[2]
83
-9
67
9
-12
fMAX2 (MHz) (Pipelined)
50
Max. Access Time (ns)
(Clock to Data,
Pipelined)
6.5
7.5
12
Typical Operating
Current ICC (mA)
175
25
155
25
135
20
115
20
TypicalStandbyCurrent
for ISB1 (mA) (Both
Ports TTL Level)
TypicalStandbyCurrent
for ISB3 (µA) (Both Ports
CMOS Level)
10 µA
10 µA
10 µA
10 µA
Notes:
10. This pin is NC for CY7C09369V.
11. This pin is NC for CY7C09369V and CY7C09379V.
Document #: 38-06056 Rev. **
Page 3 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Pin Definitions
Left Port
A0L–A15L
ADSL
Right Port
Description
A0R–A15R
Address Inputs (A0–A14 for 32K, A0–A13 for 16K devices).
ADSR
Address Strobe Input. Used as an address qualifier. This signal should be asserted LOW to
access the part using an externally supplied address. Asserting this signal LOW also loads the
burst counter with the address present on the address pins.
CE0L,CE1L
CE0R,CE1R
Chip Enable Input. To select either the left or right port, both CE0 AND CE1 must be asserted
to their active states (CE0 ≤ VIL and CE1 ≥ VIH).
CLKL
CLKR
Clock Signal. This input can be free running or strobed. Maximum clock input rate is fMAX.
CNTENL
CNTENR
Counter Enable Input. Asserting this signal LOW increments the burst address counter of its
respective port on each rising edge of CLK. CNTEN is disabled if ADS or CNTRST are asserted
LOW.
CNTRSTL
CNTRSTR
Counter Reset Input. Asserting this signal LOW resets the burst address counter of its respec-
tive port to zero. CNTRST is not disabled by asserting ADS or CNTEN.
I/O0L–I/O17L
I/O0R–I/O17R Data Bus Input/Output (I/O0–I/O15 for x16 devices).
LBL
LBR
Lower Byte Select Input. Asserting this signal LOW enables read and write operations to the
lower byte. (I/O0–I/O8 for x18, I/O0–I/O7 for x16) of the memory array. For read operations both
the LB and OE signals must be asserted to drive output data on the lower byte of the data pins.
UBL
OEL
UBR
OER
Upper Byte Select Input. Same function as LB, but to the upper byte (I/O8/9L–I/O15/17L).
Output Enable Input. This signal must be asserted LOW to enable the I/O data pins during read
operations.
R/WL
R/WR
Read/Write Enable Input. This signal is asserted LOW to write to the dual port memory array.
For read operations, assert this pin HIGH.
FT/PIPEL
FT/PIPER
Flow-Through/Pipelined Select Input. For flow-through mode operation, assert this pin LOW.
For pipelined mode operation, assert this pin HIGH.
GND
NC
Ground Input.
No Connect.
Power Input.
VCC
Output Current into Outputs (LOW)............................. 20 mA
Maximum Ratings
Static Discharge Voltage ........................................... >1100V
Latch-Up Current...................................................... >200mA
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature................................. –65°C to +150°C
Operating Range
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Ambient
Supply Voltage to Ground Potential............... –0.5V to +4.6V
Range
Commercial
Industrial
Temperature
0°C to +70°C
–40°C to +85°C
VCC
DC Voltage Applied to
Outputs in High Z State ...........................–0.5V to VCC+0.5V
3.3V ± 300 mV
3.3V ± 300 mV
DC Input Voltage......................................–0.5V to VCC+0.5V
Document #: 38-06056 Rev. **
Page 4 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Electrical Characteristics Over the Operating Range
CY7C09269V/79V/89V
CY7C09369V/79V/89V
-6[1, 2]
-7[2]
-9
-12
Parameter
Description
VOH
Output HIGH Voltage (VCC = Min.
lOH = –4.0 mA)
2.4
2.4
2.0
2.4
2.4
2.0
V
V
VOL
Output LOW Voltage (VCC = Min.
lOH = +4.0 mA)
0.4
0.8
0.4
0.8
0.4
0.8
0.4
0.8
VIH
VIL
IOZ
ICC
Input HIGH Voltage
Input LOW Voltage
2.0
2.0
V
V
Output Leakage Current
–10
10 –10
10 –10
10 –10
10 µA
Operating Current
Com’l.
175 320
155 275
275 390
135 230
185 300
115 180 mA
mA
(VCC = Max, IOUT = 0 mA)
Outputs Disabled
Indust.
ISB1
ISB2
ISB3
ISB4
Standby Current (Both
Ports TTL Level)[12] CEL &
CER ≥ VIH, f = fMAX
Com’l.
25 95
25 85
85 120
20
35
75
85
20
70 mA
mA
Indust.
Standby Current (One Port Com’l.
115 175
10 250
105 135
105 165
165 210
95 155
105 165
85 140 mA
mA
TTL Level)[12] CEL | CER
VIH, f = fMAX
≥
Indust.
Standby Current (Both
Com’l.
10 250
10 250
10 250
10 250
10 250 µA
µA
Ports CMOS Level)[12] CEL
Indust.
& CER ≥ VCC – 0.2V, f = 0
Standby Current (One Port Com’l.
95 125
125 170
85 115
95 125
75 100 mA
mA
CMOS Level)[12] CEL | CER
Indust.
≥ VIH, f = fMAX
Capacitance
Parameter
Description
Input Capacitance
Output Capacitance
Test Conditions
Max.
10
Unit
pF
CIN
TA = 25°C, f = 1 MHz,
VCC = 3.3V
COUT
10
pF
Note:
12. CEL and CER are internal signals. To select either the left or right port, both CE0 and CE1 must be asserted to their active states (CE0 ≤ VIL and CE1 ≥ VIH).
Document #: 38-06056 Rev. **
Page 5 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
AC Test Loads
3.3V
3.3V
R
TH
= 250Ω
R1 = 590Ω
OUTPUT
C = 30 pF
OUTPUT
R1 = 590Ω
OUTPUT
C = 5 pF
C = 30 pF
R2 = 435Ω
R2 = 435Ω
V
TH
= 1.4V
(a) Normal Load (Load 1)
(c) Three-State Delay(Load 2)
(b) Thévenin Equivalent (Load 1)
(Used for tCKLZ, tOLZ, & tOHZ
including scope and jig)
AC Test Loads (Applicable to -6 and -7 only)[13]
ALL INPUTPULSES
90%
Z0 = 50
Ω
R = 50Ω
OUTPUT
3.0V
GND
90%
10%
C
10%
3 ns
3 ns
≤
V
TH
= 1.4V
≤
(a) Load 1 (-6 and -7 only)
0.60
0.50
0.40
0.30
0.20
0. 1 0
0.00
1 0
1 5
20
25
30
35
Capacitance (pF)
(b) Load Derating Curve
Note:
13. Test Conditions: C = 10 pF.
Document #: 38-06056 Rev. **
Page 6 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Characteristics Over the Operating Range
CY7C09269V/79V/89V
CY7C09369V/79V/89V
-6[1, 2]
-7[2]
-9
-12
Parameter
Description
fMax Flow-Through
fMAX1
fMAX2
tCYC1
tCYC2
tCH1
tCL1
tCH2
tCL2
tR
53
45
83
40
67
33
50
MHz
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
fMax Pipelined
100
Clock Cycle Time - Flow-Through
Clock Cycle Time - Pipelined
Clock HIGH Time - Flow-Through
Clock LOW Time - Flow-Through
Clock HIGH Time - Pipelined
Clock LOW Time - Pipelined
Clock Rise Time
19
10
6.5
6.5
4
22
12
7.5
7.5
5
25
15
12
12
6
30
20
12
12
8
4
5
6
8
3
3
3
3
3
3
3
3
tF
Clock Fall Time
tSA
Address Set-Up Time
Address Hold Time
3.5
0
4
0
4
1
4
1
4
1
4
1
4
1
5
1
4
1
4
1
4
1
4
1
4
1
4
1
5
1
4
1
tHA
tSC
Chip Enable Set-Up Time
Chip Enable Hold Time
R/W Set-Up Time
3.5
0
4
tHC
0
tSW
3.5
0
4
tHW
R/W Hold Time
0
tSD
Input Data Set-Up Time
Input Data Hold Time
3.5
0
4
tHD
0
tSAD
tHAD
tSCN
tHCN
tSRST
tHRST
tOE
ADS Set-Up Time
3.5
0
4
ADS Hold Time
0
CNTEN Set-Up Time
3.5
0
4.5
0
CNTEN Hold Time
CNTRST Set-Up Time
CNTRST Hold Time
3.5
0
4
0
Output Enable to Data Valid
OE to Low Z
8
9
10
12
[14,15]
tOLZ
2
1
2
1
2
1
2
1
[14,15]
tOHZ
OE to High Z
7
7
7
20
9
7
tCD1
tCD2
tDC
Clock to Data Valid - Flow-Through
Clock to Data Valid - Pipelined
Data Output Hold After Clock HIGH
Clock HIGH to Output High Z
Clock HIGH to Output Low Z
15
6.5
18
7.5
25
12
2
2
2
2
2
2
2
2
2
2
2
2
[14,15]
tCKZ
9
9
9
9
[14,15]
tCKZ
Port to Port Delays
tCWDD Write Port Clock HIGH to Read Data Delay
tCCS Clock to Clock Set-Up Time
30
9
35
10
40
15
40
15
ns
ns
Notes:
14. Test conditions used are Load 2.
15. This parameter is guaranteed by design, but it is not production tested.
Document #: 38-06056 Rev. **
Page 7 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Waveforms
Read Cycle for Flow-Through Output (FT/PIPE = VIL)[16, 17, 18, 19]
t
CYC1
t
t
CL1
CH1
CLK
CE
CE
0
1
t
t
t
t
HC
SC
HC
SC
R/W
t
t
t
t
SW
SA
HW
HA
A
A
A
A
n+3
n
n+1
n+2
ADDRESS
t
CKHZ
t
t
DC
CD1
DATA
OUT
Q
Q
t
Q
n
n+1
n+2
DC
t
t
CKLZ
t
OHZ
OLZ
OE
t
OE
Read Cycle for Pipelined Operation (FT/PIPE = VIH)[16, 17, 18, 19]
t
CYC2
t
t
CL2
CH2
CLK
CE
CE
0
1
t
t
t
t
HC
SC
HC
SC
R/W
t
t
t
t
SW
SA
HW
HA
ADDRESS
A
A
A
A
n+3
n
n+1
n+2
t
1 Latency
t
DC
CD2
DATA
OUT
Q
Q
Q
n+2
n
n+1
t
OHZ
t
t
CKLZ
OLZ
OE
tOE
Notes:
16. OE is asynchronously controlled; all other inputs are synchronous to the rising clock edge.
17. ADS = VIL, CNTEN and CNTRST = VIH
18. The output is disabled (high-impedance state) by CE0=VIH or CE1 = VIL following the next rising edge of the clock.
19. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK. Numbers are for reference only.
.
Document #: 38-06056 Rev. **
Page 8 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Waveforms (continued)
Bank Select Pipelined Read[20, 21]
t
CYC2
t
t
CL2
CH2
CLK
L
t
t
t
HA
SA
ADDRESS
A
A
A
5
A
A
A
(B1)
3
4
0
1
2
t
HC
SC
CE
0(B1)
t
t
t
t
t
CKHZ
t
t
CD2
CD2
CD2
HC
CKHZ
SC
D
D
D
3
DATA
1
0
OUT(B1)
t
t
HA
SA
t
t
t
CKLZ
DC
DC
A
A
A
5
ADDRESS
A
0
A
A
3
4
(B2)
1
2
t
t
HC
SC
CE
0(B2)
t
t
t
CD2
t
CD2
CKHZ
t
SC
HC
DATA
OUT(B2)
D
D
4
2
t
t
CKLZ
CKLZ
Left Port Write to Flow-Through Right Port Read[22, 23, 24, 25]
CLK
R/W
L
L
t
t
HW
SW
t
t
HA
SA
NO
MATCH
ADDRESS
MATCH
VALID
L
t
t
HD
SD
DATA
INL
t
CCS
CLK
R
R
R
t
CD1
t
t
t
t
SW
SA
HW
HA
R/W
NO
MATCH
MATCH
ADDRESS
t
t
CWDD
CD1
DATA
VALID
VALID
OUTR
t
DC
t
DC
Notes:
20. In this depth expansion example, B1 represents Bank #1 and B2 is Bank #2; Each Bank consists of one Cypress dual-port device from this datasheet.
ADDRESS(B1) = ADDRESS(B2)
.
21. UB, LB, OE and ADS = VIL; CE1(B1), CE1(B2), R/W, CNTEN, and CNTRST = VIH
.
22. The same waveforms apply for a right port write to flow-through left port read.
23. CE0, UB, LB, and ADS = VIL; CE1, CNTEN, and CNTRST = VIH
.
24. OE = VIL for the Right Port, which is being read from. OE = VIH for the Left Port, which is being written to.
25. It tCCS ≤ maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS>maximum specified, then data is not valid
until tCCS + tCD1. tCWDD does not apply in this case.
Document #: 38-06056 Rev. **
Page 9 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Waveforms (continued)
Pipelined Read-to-Write-to-Read (OE = VIL)[19, 26, 27, 28]
t
CYC2
t
t
CL2
CH2
CLK
CE
0
1
t
t
HC
SC
CE
t
t
HW
SW
R/W
t
t
HW
SW
A
A
A
A
A
A
n+4
n
n+1
n+2
n+2
n+3
ADDRESS
t
t
SD HD
t
t
HA
SA
DATA
D
IN
n+2
t
t
t
t
CD2
CD2
CKHZ
CKLZ
Q
Q
n+3
n
DATA
OUT
READ
NO OPERATION
WRITE
READ
Pipelined Read-to-Write-to-Read (OE Controlled)[19, 26, 27, 28]
t
CYC2
t
t
CL2
CH2
CLK
CE
0
1
t
t
HC
SC
CE
t
t
HW
SW
R/W
t
t
HW
SW
A
A
A
A
A
A
n+5
n
n+1
n+2
n+3
n+4
ADDRESS
t
t
HA
t
t
SA
SD HD
D
DATA
D
n+2
IN
n+3
t
t
t
CD2
CD2
CKLZ
DATA
Q
Q
n+4
OUT
n
t
OHZ
OE
READ
WRITE
READ
Notes:
26. Output state (High, LOW, or high impedance) is determined by the previous cycle control signals.
27. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH
.
28. During “No Operation”, data in memory at the selected address may be corrupted and should be rewritten to ensure data integrity.
Document #: 38-06056 Rev. **
Page 10 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Waveforms (continued)
Flow-Through Read-to-Write-to-Read (OE = VIL)[17, 19, 27, 28]
t
CYC1
t
t
CH1
CL1
CLK
CE
CE
0
1
t
t
HC
SC
t
t
HW
SW
R/W
t
t
HW
SW
A
A
A
A
D
A
A
n+4
n
n+1
n+2
n+2
n+3
ADDRESS
t
t
HD
SD
t
t
HA
SA
n+2
DATA
IN
t
t
t
t
CD1
CD1
CD1
CD1
DATA
Q
Q
Q
n+3
OUT
n
n+1
t
t
t
t
DC
DC
CKHZ
CKLZ
NO
OPERATION
READ
WRITE
READ
Flow-Through Read-to-Write-to-Read (OE Controlled)[17, 19, 26, 27, 28]
t
CYC1
t
t
CH1
CL1
CLK
CE
CE
0
1
t
t
HC
SC
t
t
HW
SW
R/W
t
t
HW
SW
A
A
A
A
D
A
A
n+5
n
n+1
n+2
n+3
n+4
ADDRESS
t
t
HD
SD
t
t
HA
SA
D
n+2
n+3
t
DATA
t
OE
IN
DC
t
t
CD1
CD1
t
CD1
Q
Q
n+4
n
DATA
OUT
t
OHZ
t
t
DC
CKLZ
OE
READ
WRITE
READ
Document #: 38-06056 Rev. **
Page 11 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Waveforms (continued)
Pipelined Read with Address Counter Advance[29]
t
CYC2
t
t
CH2
CL2
CLK
t
t
HA
SA
ADDRESS
A
n
t
t
t
t
SAD
HAD
ADS
t
t
t
t
SAD
HAD
CNTEN
SCN
HCN
SCN
HCN
t
CD2
DATA
OUT
Q
Q
Q
Q
Q
Q
n+3
x-1
x
n
n+1
n+2
t
READ
DC
COUNTER HOLD
READ WITH COUNTER
READ WITH COUNTER
EXTERNAL
ADDRESS
Flow-Through Read with Address Counter Advance[29]
t
CYC1
t
t
CH1
CL1
CLK
t
t
HA
SA
A
n
ADDRESS
t
t
t
SAD
HAD
ADS
t
t
t
t
SAD
HAD
CNTEN
t
SCN
HCN
SCN
HCN
t
CD1
Q
Q
Q
Q
Q
n+3
DATA
x
n
n+1
n+2
OUT
t
DC
READ
READ
WITH
COUNTER HOLD
READ WITH COUNTER
EXTERNAL
ADDRESS
COUNTER
Note:
29. CE0 and OE = VIL; CE1, R/W and CNTRST = VIH
.
Document #: 38-06056 Rev. **
Page 12 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Waveforms (continued)
Write with Address Counter Advance (Flow-Through or Pipelined Outputs)[30, 31]
t
CYC2
t
t
CH2
CL2
CLK
t
t
HA
SA
A
ADDRESS
n
INTERNAL
ADDRESS
A
A
A
A
A
n+4
n
n+1
n+2
n+3
t
t
HAD
SAD
ADS
CNTEN
t
t
HCN
SCN
D
D
D
D
D
D
n+4
DATA
n
n+1
n+1
n+2
n+3
IN
t
t
HD
SD
WRITE EXTERNAL
ADDRESS
WRITE WITH WRITE COUNTER
COUNTER HOLD
WRITE WITH COUNTER
Notes:
30. CE0, UB, LB, and R/W = VIL; CE1 and CNTRST = VIH
.
31. The “Internal Address” is equal to the “External Address” when ADS = VIL and equals the counter output when ADS = VIH
.
Document #: 38-06056 Rev. **
Page 13 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Switching Waveforms (continued)
Counter Reset (Pipelined Outputs)[19, 26, 32, 33]
t
CYC2
t
t
CH2
CL2
CLK
t
t
HA
SA
A
A
ADDRESS
n
n+1
INTERNAL
ADDRESS
A
0
1
A
A
n+1
X
n
t
t
HW
SW
R/W
ADS
t
t
SAD
HAD
t
t
SCN
HCN
CNTEN
t
t
HRST
SRST
CNTRST
t
t
HD
SD
DATA
D
IN
0
DATA
Q
Q
Q
n
OUT
0
1
COUNTER
RESET
WRITE
ADDRESS 0
READ
ADDRESS 0
READ
ADDRESS 1
READ
ADDRESS n
Notes:
32. CE0, UB, and LB = VIL; CE1 = VIH
.
33. No dead cycle exists during counter reset. A READ or WRITE cycle may be coincidental with the counter reset.
Document #: 38-06056 Rev. **
Page 14 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Read/Write and Enable Operation[34, 35, 36]
Inputs
Outputs
I/O0–I/O17
High-Z
OE
CLK
CE0
CE1
R/W
Operation
X
H
X
X
Deselected[37]
X
X
L
X
L
L
L
L
X
L
High-Z
DIN
Deselected[37]
Write
H
H
H
H
X
DOUT
High-Z
Read[35]
H
X
Outputs Disabled
Address Counter Control Operation[34, 38, 39, 40]
Previous
Address Address CLK ADS CNTEN CNTRST
I/O
Mode
Operation
X
An
X
X
X
X
X
H
L
H
H
Dout(0)
Reset
Counter Reset to Address 0
X
L
Dout(n)
Dout(n)
Load
Hold
Address Load into Counter
An
H
External Address Blocked—Counter
Disabled
X
An
H
L
H
Dout(n+1) Increment Counter Enabled—Internal Address
Generation
Notes:
34. “X” = “Don’t Care”, “H” = VIH, “L” = VIL.
35. ADS, CNTEN, CNTRST = “Don’t Care”.
36. OE is an asynchronous input signal.
37. When CE changes state In the pipelined mode, deselection and read happen in the following clock cycle.
38. CE0 and OE = VIL; CE1 and R/W = VIH
.
39. Data shown for flow-through mode; pipelined mode output will be delayed by one cycle.
40. Counter operation is independent of CE0 and CE1.
Document #: 38-06056 Rev. **
Page 15 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Ordering Information
16K x16 3.3V Synchronous Dual-Port SRAM
Speed (ns)
6.5[1, 2]
7.5[2]
Ordering Code
CY7C09269V-6AC
CY7C09269V-7AC
CY7C09269V-9AC
CY7C09269V-9AI
CY7C09269V-12AC
Package Name
A100
Package Type
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
Operating Range
Commercial
Commercial
Commercial
Industrial
A100
9
A100
A100
12
A100
Commercial
32K x16 3.3V Synchronous Dual-Port SRAM
Speed (ns)
6.5[1, 2]
7.5[2]
Ordering Code
CY7C09279V-6AC
CY7C09279V-7AC
CY7C09279V-9AC
CY7C09279V-9AI
CY7C09279V-12AC
Package Name
A100
Package Type
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
Operating Range
Commercial
Commercial
Commercial
Industrial
A100
9
A100
A100
12
A100
Commercial
64K x16 3.3V Synchronous Dual-Port SRAM
Speed (ns)
6.5[1, 2]
7.5[2]
Ordering Code
CY7C09289V-6AC
CY7C09289V-7AC
CY7C09289V-9AC
CY7C09289V-9AI
CY7C09289V-12AC
Package Name
A100
Package Type
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
Operating Range
Commercial
Commercial
Commercial
Industrial
A100
9
A100
A100
12
A100
Commercial
16K x18 3.3V Synchronous Dual-Port SRAM
Speed (ns)
6.5[1, 2]
7.5[2]
Ordering Code
CY7C09369V-6AC
CY7C09369V-7AC
CY7C09369V-7AI
CY7C09369V-9AC
CY7C09369V-9AI
CY7C09369V-12AC
Package Name
A100
Package Type
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
Operating Range
Commercial
Commercial
Industrial
A100
7.5[2]
A100
9
A100
Commercial
Industrial
A100
12
A100
Commercial
32K x18 3.3V Synchronous Dual-Port SRAM
Speed (ns)
6.5[1, 2]
7.5[2]
Ordering Code
CY7C09379V-6AC
CY7C09379V-7AC
CY7C09379V-9AC
CY7C09379V-9AI
CY7C09379V-12AC
Package Name
A100
Package Type
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
Operating Range
Commercial
Commercial
Commercial
Industrial
A100
9
A100
A100
12
A100
Commercial
Document #: 38-06056 Rev. **
Page 16 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
64K x18 3.3V Synchronous Dual-Port SRAM
Speed (ns)
6.5[1, 2]
7.5[2]
Ordering Code
CY7C09389V-6AC
CY7C09389V-7AC
CY7C09389V-9AC
CY7C09389V-9AI
CY7C09389V-12AC
Package Name
A100
Package Type
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
100-Pin Thin Quad Flat Pack
Operating Range
Commercial
Commercial
Commercial
Industrial
A100
9
A100
A100
12
A100
Commercial
Document #: 38-06056 Rev. **
Page 17 of 19
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Package Diagram
100-Pin Thin Plastic Quad Flat Pack (TQFP) A100
51-85048-B
Document #: 38-06056 Rev. **
Page 18 of 19
© Cypress Semiconductor Corporation, 2001. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.
CY7C09269V/79V/89V
CY7C09369V/79V/89V
Document Title: CY7C09269V/79V/89V CY7C09369V/79V/89V 3.3V 16K/32K/64K X 16/18 Synchronous Dual Port Static
RAM
Document Number: 38-06056
Issue
Date
Orig. of
Change
REV.
ECN NO.
Description of Change
**
110215
12/18/01
SZV
Change from Spec number: 38-00668 to 38-06056
Document #: 38-06056 Rev. **
Page 19 of 19