DS1050/DS1052
5-Bit Programmable
Pulse Width Modulator
www.dalsemi.com
FEATURES
ꢀ Single 5-bit programmable pulse width
modulator (PWM)
PIN ASSIGNMENT
DS1050
SCL
SDA
A0
1
2
3
4
8
7
6
5
VCC
A1
ꢀ Adjustable Duty Cycle: 0% to 100%
ꢀ 2.5V to 5.5V Operation
ꢀ Standard Frequency Values:
1 kHz, 5 kHz, 10 kHz, and 100 kHz
ꢀ 2-Wire Addressable Interface
ꢀ Packages: 8-Pin DIP, 8-Pin (150 mil) SOIC
and 8-Pin (118 mil) µSOP
A2
GND
PWMο
8L-DIP
ꢀ Operating Temperature: -40oC to +85oC
8L-(150 mil) SOIC
8L-(118 mil) µSOP
Ordering Information
PIN DESCRIPTION
Part Number
Frequency Package
VCC
2.5V to 5.5V Power Supply
DS1050M-001 1 kHz
DS1050M-005 5 kHz
DS1050M-010 10 kHz
8-P 300 mil DIP
8-P 300 mil DIP
8-P 300 mil DIP
PWMO
A0,A1,A2
SDA
PWM Ouput
Device Address
Serial Data I/O
Serial Clock Input
Ground
DS1052M-100 100 kHz 8-P 300 mil DIP
SCL
DS1050Z-001
DS1050Z-005
DS1050Z-010
DS1052Z-100
1 kHz
5 kHz
10 kHz
8-P 150-mil SOIC
8-P 150-mil SOIC
8-P 150-mil SOIC
GND
100 kHz 8-P 150-mil SOIC
DS1050U-001
DS1050U-005
DS1050U-010
DS1052U-100
1 kHz
5 kHz
10 kHz
8-P 118-mil µSOP
8-P 118-mil µSOP
8-P 118-mil µSOP
100 kHz 8-P 118-mil µSOP
DESCRIPTION
The DS1050/DS1052 is a programmable 5-bit pulse width modulator featuring a 2-wire addressable
controlled interface. The DS1050/DS1052 provides operation from power supplies ranging from
2.5 volts up to 5.5 volts. The PWM output provides a signal that swings from 0 volt to VCC (power
supply). The DS1050 requires a typical operating current of 500 µA and a programmable shutdown
supply current of 1 µA. The DS1052 requires a typical operating current of 500 µA and a programmable
shutdown supply current of 1 µA.
Four standard PWM output frequencies are offered and include 1 kHz, 5 kHz, 10 kHz, and 100 kHz. The
2-wire addressable interface allows operation of multiple devices on a single 2-wire bus and provides
compatibility with other Dallas Semiconductor 2-wire devices: including real-time clocks (RTCs), digital
thermometers, and digital potentiometers.
1 of 11
081800
DS1050/DS1052
The device is ideal for low cost LCD contrast and/or brightness control, power supply voltage adjustment,
battery charging or current adjustment. The DS1050/DS1052 is offered in standard integrated circuit
packaging including the 8-L DIP, 8-L (150 mil) SOIC, and the space saving 8-L (118 mil) µSOP.
OPERATION
Interface protocol is simplified to an 8-bit control byte and 8-bit data-byte. Information can be read or
written to the DS1050/DS1052 including a commanded shutdown operation.
Power-up Configuration
The DS1050/DS1052 powers-up to half-scale (10000B) providing 50% duty-cycle. Once powered, the
PWM output can be changed via the 2-wire addressable serial port.
Pin Description
Vcc- Power supply terminal. The DS1050/DS1052 will support operation from power supply voltages
ranging from +2.5 volts to +5.5 volts.
GND - Ground terminal.
PWMO – Pulse-width modulated output. This output is a square-wave having amplitudes from 0 volt to
VCC. The duty cycle of this output is governed by a 5-bit control register. Output duty cycles range from
0% to 96.88%. An additional command sequence will provide a 100% duty cycle or “full-on”.
SCL – Serial clock input.
SDA – Serial bi-directional data I/O.
A0,A1,A2 - Device address (chip selects).
2-Wire Addressable Serial Port Control.
The 2-wire serial port interface supports a bi-directional data transmission protocol with device
addressing. A device that sends data on the bus is defined as a transmitter, and a device receiving data as
a receiver. The device that controls the message is called a "master". The devices that are controlled by
the master are "slaves". The bus must be controlled by a master device which generates the serial clock
(SCL), controls the bus access, and generates the START and STOP conditions. The DS1050/DS1052
operates as a slave on the 2-wire bus. Connections to the bus are made via the open-drain I/O lines SDA
and SCL.
The following I/O terminals control the 2-wire serial port: SDA, SCL, A0, A1, A2. A 2-wire serial port
overview and timing diagrams for the 2-wire serial port can be found in Figures 2 and 3, respectively.
Timing information for the 2-wire serial port is provided in the “AC Electrical Characteristics” table for
2-wire serial communications.
The following bus protocol has been defined (See Figure 2).
•
•
Data transfer may be initiated only when the bus is not busy.
During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in
the data line while the clock line is high will be interpreted as control signals.
2 of 11
DS1050/DS1052
Accordingly, the following bus conditions have been defined:
Bus not busy: Both data and clock lines remain HIGH.
Start data transfer: A change in the state of the data line, from HIGH to LOW, while the clock is HIGH,
defines a START condition.
Stop data transfer: A change in the state of the data line, from LOW to HIGH, while the clock line is
HIGH, defines the STOP condition.
Data valid: The state of the data line represents valid data when, after a START condition, the data line
is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed
during the LOW period of the clock signal. There is one clock pulse per bit of data. Figure 2 details how
data transfer is accomplished on the 2-wire bus. Depending upon the state of the R/W bit, two types of
data transfer are possible.
Each data transfer is initiated with a START condition and terminated with a STOP condition. The
number of data bytes transferred between START and STOP conditions is not limited, and is determined
by the master device. The information is transferred byte-wise and each receiver acknowledges with a
ninth bit.
Within the bus specifications, a regular mode (100 kHz clock rate) and a fast mode (400 kHz clock rate)
are defined. The DS1050/DS1052 works in both modes.
Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the
reception of each byte. The master device must generate an extra clock pulse which is associated with
this acknowledge bit.
A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a
way that the SDA line is stable LOW during the HIGH period of the acknowledge related clock pulse. Of
course, setup and hold times must be taken into account. A master must signal an end of data to the slave
by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this case,
the slave must leave the data line HIGH to enable the master to generate the STOP condition.
1. Data transfer from a master transmitter to a slave receiver. The first byte transmitted by the
master is the command/control byte. Next follows a number of data bytes. The slave returns an
“acknowledge” bit after each received. byte.
2. Data transfer from a slave transmitter to a master receiver. The first byte (the command/control
byte) is transmitted by the master. The slave then returns an acknowledge bit. Next follows a number
of data bytes transmitted by the slave to the master. The master returns an acknowledge bit after all
received bytes other than the last byte. At the end of the last received byte, a 'not acknowledge' is
returned.
The master device generates all serial clock pulses and the START and STOP conditions. A transfer is
ended with a STOP condition or with a repeated START condition. Since a repeated START condition is
also the beginning of the next serial transfer, the bus will not be released.
3 of 11
DS1050/DS1052
The DS1050/DS1052 may operate in the following two modes:
1. Slave receiver mode: Serial data and clock are received through SDA and SCL, respectively. After
each byte is received, an acknowledge bit is transmitted. START and STOP conditions are
recognized as the beginning and end of a serial transfer. Address recognition is performed by
hardware after reception of the slave (device) address and direction bit.
2. Slave transmitter mode: The first byte is received and handled as in the slave receiver mode.
However, in this mode the direction bit will indicate that the transfer direction is reversed. Serial data
is transmitted on SDA by the DS1050/DS1052 while the serial clock is input on SCL. START and
STOP conditions are recognized as the beginning and end of a serial transfer.
SLAVE ADDRESS
A command/control byte is the first byte received following the START condition from the master
device. The command/control byte consists of a four bit control code. For the DS1050/DS1052, this is
set as 0101 binary for read/write operations. The next three bits of the command/control byte are the
device select bits or slave address (A2, A1, A0). They are used by the master device to select which of
eight possible devices is to be accessed. When reading or writing the DS1050/DS1052, the device select
bits must match the device select pins (A2,A1,A0). The last bit of the command/control byte (R/W)
defines the operation to be performed. When set to a one a read operation is selected, and when set to a
zero a write operation is selected. The command control byte is presented in Figure 3.
Following the START condition, the DS1050/DS1052 monitors the SDA bus checking the device type
identifier being transmitted. Upon receiving the 0101 control code, the appropriate device address bits,
and the read/write bit, the slave device outputs an “acknowledge” signal on the SDA line.
COMMAND AND PROTOCOL
The command and protocol structure of the DS1050/DS1052 allows the user to read or write the PWM
configuration register or place the device in a low-current state (shut-down mode) and recall the device
from a low-current state.. Additionally, the 2-wire command/protocol structure of the DS1050/DS1052
will support eight different devices that can be uniquely controlled.
Figure 4a,b,c,d, & e show the five different command and protocol bytes for the DS1050/DS1052. These
include the following command operations: 1) Set PWM Duty Cycle, 2) Set PWM Duty Cycle 100%, 3)
Set shutdown mode, 4) Set recall mode, 5) Read PWM configuration register.
The command operation “Set PWM Duty Cycle” is used to configure the output duty cycle of the
device. The DS1050/DS1052 has a 5-bit resolution and is capable of setting the duty cycle output from
0% up to 96.88% in steps of 3.125%. A binary value of (00000B) sets the duty cycle output at 0% while
a binary value of (11111B) sets the duty cycle output at 96.88%.
The command operation “Set PWM Duty Cycle 100%” is used to configure the output duty cycle of the
device to a “full-on”. This command is provided in addition to the Set PWM Duty Cycle command for
flexibility and convenience in total duty cycle coverage. It allows the user to provide a total duty cycle
range from 0% to 100%.
The command operation “Set shutdown mode” is used to provide a low-current (inactive state) state for
the DS1050/DS1052. When in a low-current state the DS1050/DS1052 will draw currents less than or
equal to 1 µA. The PWMO output will be high impedance.
4 of 11
DS1050/DS1052
The command operation “Set Recall Mode” is used to recall the DS1050/DS1052 from a low-current
state. The value of the PWMO output is recalled to that prior to initiating a “Set shutdown mode”
command.
The “Read PWM Duty Cycle” command is used to read the current setting of the PWM configuration
register. Information returned by this command includes PWM output value, as well as, whether the
device is in a shutdown configuration.
PWM data values and control/ command values are always transmitted most significant bit (MSB) first.
During communications, the receiving unit always generates the “acknowledge”.
Reading the DS1050/DS1052
As shown in Figure 4e, the DS1050/DS1052 provides one read command operation. This operation
allows the user to read the current setting of the PWM configuration register. Specifically, the R/W bit of
the command/control byte is set equal to a 1 for a read operation. Communication to read the
DS1050/DS1052 begins with a START condition which is issued by the master device. The
command/control byte from the master device will follow the START condition. Once the
command/control byte has been received by the DS1050/DS1052, the part will respond with an
ACKNOWLEDGE. The read/write bit of the command/control byte, as stated, should be set equal to '1'
for reading the DS1050/DS1052.
When the master has received the ACKNOWLEDGE from the DS1050/DS1052, the master can then
begin to receive the PWM configuration register data. As mentioned this data will be transmitted MSB
first. Once the eight bits of the PWM configuration register have been transmitted, the master will need
to issue an ACKNOWLEDGE, unless it is the only byte to be read, in which case the master issues a
NOT ACKNOWLEDGE. If desired the master may stop the communication transfer at this point by
issuing the STOP condition. Final communication transfer is terminated by issuing the STOP command.
Again, the flow of the read operation is presented in Figure 4e.
Writing the DS1050/DS1052
A data flow diagram for writing the DS1050/DS1052 is shown in Figure 4a,b,c, & d. The
DS1050/DS1052 has three write commands that are used to change the PWM configuration register or
the shutdown and recall mode of the device.
All the write operations begin with a START condition. Following the START condition, the master
device will issue the command/control byte. The read/write bit of the command/control byte will be set
to '0' for writing the DS1050/DS1052. Once the command/control byte has been issued and the master
receives the acknowledgment from the DS1050/DS1052, PWM configuration data is transmitted to the
DS1050/DS1052 by the master device.
A data byte for the DS1050/DS1052 will contain PWM configuration data and shutdown/recall command
data. The five least significant bits of data specify the PWM configuration value while the three most
significant bits specify the whether the device is to be shutdown or recalled. When the DS1050/DS1052
has received the data byte, it will respond with an ACKNOWLEDGE. At this point, the new PWM
configuration register
value and shutdown/recall command value will be updated in the
DS1050/DS1052. The master device, after the receipt of the ACKNOWLEDGE, can continue to transmit
additional data bytes or if the transaction is complete respond with the STOP condition. The 2-wire serial
timing diagram is presented in Figure 5.
5 of 11
DS1050/DS1052
ABSOLUTE MAXIMUM RATINGS*
Voltage on Any Pin Relative to Ground
Operating Temperature
-1.0V to +6.0V
-40oC to +85oC
Storage Temperature
-55oC to +125oC
Soldering Temperature
See J-STD-020A specification
* This is a stress rating only and functional operation of the device at these or any other conditions above
those conditions indicated in the operation section of the specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
(-40°C to +85°C; VCC = 2.5V to 5.5V)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Supply voltage
VCC
+2.5
+5.5
V
1
DC ELECTRICAL CHARACTERISTICS
(-40°C to +85°C; VCC = 2.5V to 5.5V)
PARAMETER
Supply Current
Active
SYMBOL CONDITION
MIN
TYP
50
500
MAX
UNITS NOTES
ICC
DS1050
DS1052
2
2
µA
µA
µA
V
V
V
Input Leakage
Input Logic 1
Input Logic 0
Input Logic Levels
A0, A1, A2
ILI
VIH
VIL
+1
VCC+0.5
0.3 VCC
0.3 VCC
1,3
1,3
4
Input Logic 1
0.7 VCC
Input Logic 0
0.4<VI/O<0.9
VCC
GND-0.5
-10
0.3 VCC
10
Input Current each
I/O pin
Standby Current
3V
µA
µA
Istby
0.5
10
1
5
5V
LOW level ouput
voltage
VOL1
VOL2
3 mA sink
current
3 mA sink
current
0.0
0.0
0.4
0.6
V
V
I/O Capacitance
Pulse width of spikes
which must be
CI/O
tSP
pF
ns
0
50
suppressed by the
input filter
6 of 11
DS1050/DS1052
AC ELECTRICAL CHARACTERISTICS
(-40°C to +85°C; VCC = 2.5V to 5.5V)
PARAMETER
SYMBOL CONDITION
MIN
0
TYP
MAX
400
UNITS NOTES
SCL clock frequency
fSCL
kHz
*,6
**
0
100
Bus free time
between STOP and
START condition
Hold time (repeated)
START condition
Low period of SCL
clock
tBUF
1.3
4.7
*,6
**
µs
tHD:STA
tLOW
0.6
4.0
1.3
4.7
0.6
4.0
0
0
*,7,6
**
*,6
**
*,6
**
*,6,8,9
**
*,6
**
µs
µs
µs
µs
ns
ns
High period of SCL
clock
tHIGH
tHD:DAT
tSU:DAT
tR
Data hold time
0.9
Data set-up time
100
250
20+0.1CB
Rise time of both
SDA and SCL
signals
300
1000
*,10
**
Fall time of both
SDA and SCL
signals
tF
20+0.1CB
300
300
ns
*,10
**
Set-up time for
STOP condition
Capacitive load for
each bus line
PWM Output
Change
tSU:STO
CB
0.6
4.0
*
**
10
µs
pF
400
2
periods
11
tPWMο
*fast mode
**standard mode
AC ELECTRICAL CHARACTERISTICS
(-40°C to +85°C; VCC = 2.5V to 5.5V)
PARAMETER
Output Frequency
Tolerance
SYMBOL CONDITION
MIN
TYP
MAX
UNITS NOTES
-20
+20
%
12
Output Impedance
Full-scale duty cycle
Zero-scale duty
cycle
200
Ω
%
%
96.88
0
13
13
Absolute Linearity
Relative Linearity
Resolution
-0.5
-0.25
+0.5
+0.25
LSB
LSB
Bits
14
15
13
5
7 of 11
DS1050/DS1052
NOTES:
1. All voltages are referenced to ground.
2. ISTBY specified for VCC between 3.0V and 5.0V. control port logic pins are driven to the appropriate
logic levels. Appropriate logic levels specify that logic inputs are within a 0.5V of ground or VCC for
the corresponding inactive state.
3. I/O pins of fast mode devices must not obstruct the SDA and SCL lines if VCC is switched off.
4. Address Inputs, A0, A1, and A2, should be tied to either VCC or GND depending on the desired
address selections.
5.
ISTBY specified for VCC between 3.0V and 5.0V, control port logic pins are driven to the appropriate
logic levels.
6. A fast mode device can be used in a standard mode system, but the requirement tSU:DAT > 250 ns
must then be met. This will automatically be the case if the device does not stretch the LOW period
of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output
the next data bit to the SDA line tRMAX + tSU:DAT = 1000+250=1250 ns before the SCL line is
released.
7. After this period, the first clock pulse is generated.
8. The maximum tSU:DAT has only to be met if the device does not stretch the LOW period (tLOW) of the
SCL signal.
9. A device must internally provide a hold time of at least 300 ns for the SDA signal (referred to the
V
IH MIN of the SCL signal) in order to bridge the undefined region of the falling edge of SCL.
10. CB - total capacitance of one bus line in picofarads, timing referenced to (0.9)(VCC) and (0.1)(VCC).
11. A PWM output duty cycle change will occur with 2 periods of the output frequency when a change is
initiated.
12. The absolute frequency output of the PWM can be expected to fall within a ±20% range from the
nominal specified value of the device.
13. The DS1050/DS1052 is a 5-Bit PWM. The output duty cycles of the device range from 0% to 100%
in step sizes of 3.125%. The “Set PWM Duty Cycle 100%, allows the PWM output to be set to
“full-on”.
14. Absolute Linearity is used to compare measured duty cycle against expected duty cycle as
determined by the DAC setting. The DS1050/DS1052 is specified to provide an absolute linearity of
±0.5 LSB.
15. Relative Linearity is used to determine the change in duty cycle between adjacent or successive DAC
settings. The DS1050/DS1052 is specified to provide a relative linearity specification of ±0.25 LSB.
8 of 11
DS1050/DS1052
Figure 1 BLOCK DIAGRAM
vcc
OSCILLATOR
DRIVER
PWMΟ
CONTROL LOGIC
SCL
SDA
SHUTDOWN
CONTROL
CIRCUITRY
Serial Port
A0
A1
A2
GND
Figure 2 2-WIRE ADDRESSABLE SERIAL PORT OVERVIEW
SDA
msb
slave address
r/w
direction
bit
acknowledgement
signal fromreceiver
acknowledgement
signal fromreceiver
SCL
3-7
1
1
2
6
7
8
9
2
8
9
ACK
ACK
Start
Condition
Stop Condition
or repeated
Start Condition
repeatedif more bytes
are transferred
Figure 3 COMMAND/CONTROL BYTE
msb
lsb
r/w
A0
0
1
0
1 A2 A1
Device
Identifier
Device
Address
Read/Write
Bit
9 of 11
DS1050/DS1052
Figure 4 DS1050/DS1052 COMMANDS AND PROTOCOL
CONTROL
BYTE
PWM
DATABYTE
MSB
LSB
MSB
0
LSB
TS
S
T
A
C
K
SET PWM DUTY CYCLE
S
A
T 0 1
0
0
0
0
0
1 A2 A1 A0 0
0 0
PWM Data
O
P
R
A
T
(a)
R
T
R/W=0
CONTROL
BYTE
PWM
DATABYTE
MSB
LSB
MSB
0
LSB
S
T
A
R
T
S
T
O
P
A
C
K
0 1
1 A2 A1 A0 0
0 1
Don't Care
(b)
R/W=0
CONTROL
BYTE
PWM
DATABYTE
MSB
LSB
MSB
1
LSB
SET SHUT-DOWN MODE
S
S
T
T
A
R
T
A
C
K
S
T
A
R
T
0 1
1 A2 A1 A0 0
0
1
Don't Care
O
P
(c)
R/W=0
CONTROL
BYTE
PWM
DATABYTE
MSB
0 1
LSB
MSB
1
LSB
RECALL MODE
S
T
A
R
T
S
T
A
C
K
1 A2 A1 A0 0
0 0
Don't Care
O
P
(d)
R/W=0
CONTROL
BYTE
PWM
DATABYTE
MSB
0 1
LSB
MSB
0
LSB
READ PWM DUTY CYCLE
S
T
A
R
T
S
T
A
C
K
1 A2 A1 A0 1
0 0
PWM-DATA
O
P
(e)
R/W=1
10 of 11
DS1050/DS1052
Figure 5 2-WIRE SERIAL DIAGRAMS
SDA
t
t
t
t
SP
F
BUF
HD:STA
t
R
t
LOW
SCL
t
t
HIGH
t
HD:STA
t
SU:STO
SU:STA
t
t
HD:STA
SU:DAT
STOP
START
REPEATED
START
11 of 11