DS1869 [DALLAS]

3V Dallastat Electronic Digital Rheostat; 3V Dallastat电子数字电位器
DS1869
型号: DS1869
厂家: DALLAS SEMICONDUCTOR    DALLAS SEMICONDUCTOR
描述:

3V Dallastat Electronic Digital Rheostat
3V Dallastat电子数字电位器

电位器 电子
文件: 总8页 (文件大小:133K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DS1869  
3V DallastatTM Electronic  
Digital Rheostat  
www.dalsemi.com  
FEATURES  
PIN ASSIGNMENT  
Replaces mechanical variable resistors  
Operates from 3V or 5V supplies  
Electronic interface provided for digital as  
well as manual control  
Internal pull-ups with debounce for easy  
interfacing to mechanical push buttons  
Wiper position is maintained in the absence of  
power  
(RH)  
+V  
1
2
3
4
8
7
6
5
UC  
D
DC  
(RW)  
V-  
(RL)  
8-Pin DIP (300-mil)  
See Mech. Drawings Section  
Low cost alternative to mechanical controls  
Applications include volume, tone, contrast,  
brightness, and dimmer control  
8-pin SOIC and 8-pin DIP packages are  
available  
+V  
(RH)  
1
8
DC  
(RW)  
V-  
UC  
D
2
3
4
7
6
5
Standard resistance values for Dallastat  
(RL)  
-
-
-
DS1869-10 ~ 10 k  
DS1869-50 ~ 50 kΩ  
DS1869-100 ~ 100 kΩ  
8-Pin SOIC (208-mil)  
See Mech. Drawings Section  
Operating temperature range:  
- Industrial: -40°C to +85°C  
3V to 8V differential supply operational range  
PIN DESCRIPTION  
RH  
- High Terminal of Potentiometer  
- Wiper Terminal of Potentiometer  
- Low Terminal of Potentiometer  
- Voltage Supply Inputs  
- Up Contact Input  
RW  
RL  
-V, +V  
UC  
D
- Digital Input  
DC  
- Down Contact Input  
DESCRIPTION  
The DS1869 DallastatTM is a digital rheostat or potentiometer. This device provides 64 possible uniform  
tap points over the entire resistive range. The standard resistive ranges are 10 k, 50 k, and 100 k.  
The Dallastat can be controlled by either a switch contact closure input or a digital source input such as a  
CPU. The DS1869 operates from 3V or 5V supplies. Wiper position is maintained in the absence of  
power through the use of a EEPROM memory cell array. The EEPROM cell array will withstand more  
than 50,000 writes.  
The DS1869 is offered in two standard IC packages which include an 8-pin 300-mil DIP and an 8-pin  
208-mil SOIC. The DS1869 can be configured to operate using a single pushbutton, dual pushbutton or  
digital source input by varying power-on conditions. This is illustrated in Figures 1 and 2. The DS1869  
pinouts allow access to both ends of the potentiometer RL, RH, and the wiper, RW. Control inputs include  
the digital source input, D, the up contact input, UC, and the down contact input, DC. Other pins include  
the positive, +V, and negative, -V, supply inputs. The DS1869 is specified to operate from -40°C to  
+85°C.  
1 of 8  
112099  
DS1869  
OPERATION  
The DS1869 can be configured to operate from a single contact closure, dual contact closure, or a digital  
source input. Figures 1 and 2 illustrate both contact closure configurations. Contact closure is defined as a  
transition from a high level to a low level on the up contact (UC) or down contact (DC) inputs. All three  
control inputs are active when in a low state and are inactive when in a high state.  
The DS1869 interprets input pulse widths as the means of controlling wiper movement. A single pulse  
input on the UC, DC, or D input terminals will cause the wiper position to move 1/64th of the total  
resistance. A transition from a high to low on these inputs is considered the beginning of pulse activity or  
contact closure. A single pulse must be greater than 1 ms but lasting no longer than 1 second. Pulse  
timings are shown in Figure 5.  
Repetitive pulsed inputs can be used to step through each resistive position of the device in a relatively  
fast manner (see Figure 5b). The requirement for repetitive pulsed inputs is that pulses must be separated  
by a minimum time of 1 ms. If the input is not allowed to be inactive (high) for at least 1 ms, the DS1869  
will interpret repetitive pulses as a single pulse.  
Pulse inputs lasting longer than 1 second will cause the wiper to move one position every 100 ms  
following the initial 1-second hold time. The total time to transcend the entire potentiometer using a  
continuous input pulse is given by the formula below:  
1 second + 63 X 100 ms = 7.3 (seconds)  
Single contact closure operation allows the user to control wiper movement in either direction from a  
single pushbutton input. Figure 1 presents a typical single pushbutton configuration. The UC input is used  
to increment and decrement wiper position for single pushbutton mode of operation. The DC input  
provides no functionality in this mode but must be connected to the positive supply voltage (VCC). The  
digital source input (D) can be allowed to float.  
On device power-up, the configuration shown in Figure 1 must exist in order to enter the single contact  
closure mode of operation especially and specifically, the (DC) input’s direct connection to the positive  
supply voltage (VCC).  
The initial direction of wiper movement in single pushbutton operation is determined by prior activity.  
The initial direction of wiper movement will be opposite to that of the previous activity. Changing the  
direction of wiper movement in single pushbutton mode is accomplished by allowing a period of  
inactivity on the UC input of (greater than) 1 second, or by moving the wiper to the end of the  
potentiometer range. This will occur regardless of whether the input is a continuous pulse, a sequence of  
repetitive pulses or a single pulse.  
The digital source input, D, was designed for microprocessor or controlled applications. This control  
input manipulates the device in the same manner as the single pushbutton configuration, controlling  
movement of the wiper position in both upward and downward directions. One added feature over the  
single pushbutton configuration is the ability to increment or decrement wiper position at a faster rate.  
Digital source input control is available regardless of the type of pushbutton configuration.  
Dual pushbutton mode of operation is entered when the DC input is floated on power-up. If interfacing  
contact closure control inputs to digital logic, the DC input must be interfaced to an open drain drive  
which is high impedance during power-up; see Figure 2B. This will prevent the device from entering a  
single pushbutton mode of operation.  
2 of 8  
DS1869  
In dual pushbutton mode, each direction is controlled by the up contact (UC) and down contact (DC)  
inputs, respectively. No wait states are required to change wiper direction in dual pushbutton mode. In  
dual pushbutton mode, as the wiper position reaches the end of the potentiometer, the direction of wiper  
movement will not change. Wiper position will remain at the potentiometers’ end until an opposite  
direction input is given.  
All contact closure control inputs, UC, DC, and D, are internally pulled-up by a 100 k=resistance. The  
UC and DC inputs are internally debounced and require no external components for input signal  
conditioning.  
DS1869 SINGLE PUSHBUTTON CONFIGURATION  
(TYPICAL EXAMPLE) Figure 1  
DS1869 DUAL PUSHBUTTON CONFIGURATION  
(TYPICAL EXAMPLE) Figure 2A  
3 of 8  
DS1869  
DS1869 DUAL PORT CONFIGURATION (TYPICAL EXAMPLE) Figure 2B  
The DS1869 is provided with two supply inputs -V and +V. The maximum voltage difference between  
the two supply inputs is +8.0 volts. The minimum voltage difference is +2.7 volts. All input levels are  
referenced to the negative supply input, -V. The voltage applied to any Dallastat terminal must not exceed  
the negative supply voltage (-V ) by -0.5 or the positive supply voltage (+V) by +0.5 volts. The minimum  
logic high level must be +2.4 volts with reference to the -V supply voltage input for +V=5V. A logic low  
level with reference to the -V supply voltage has a maximum value of +0.8 volts. Dallastats exhibit a  
typical wiper resistance of 400 ohms with a maximum wiper resistance of 1000 ohms. The maximum  
wiper current allowed through the Dallastat is specified at 1 milliamps (see DC Electrical  
Characteristics).  
NONVOLATILE WIPER SETTINGS  
Dallastats maintain the position of the wiper in the absence of power. This feature is provided through the  
use of EEPROM type memory cell arrays. During normal operation the position of the wiper is  
determined by the input multiplexer. Periodically, the multiplexer will update the EEPROM memory  
cells. The manner in which an update occurs has been optimized for reliability, durability, and  
performance. Additionally, the update operation is totally transparent to the user.  
When power is applied to the Dallastat, the wiper setting will be the last recorded in the EEPROM  
memory cells. If the Dallastat setting is changed after power is applied, the new value will be stored after  
a delay of 2 seconds. The initial storage of a new value after power-up occurs when the first change is  
made, regardless of when this change is made.  
After the initial change on power-up all subsequent changes of the wiper position will be recorded only if  
the 4th LSB (out of a 6-bit total for 64 positions) is being changed. Thus any change greater than 12.5% of  
the total resistance range will trigger one EEPROM write cycle.  
Changes or storage to the EEPROM memory cells must allow for a 2-second delay to guarantee that  
updates will occur. The EEPROM memory cells are specified to accept greater that 50,000 writes before a  
wear-out condition. If the EEPROM memory cells do reach a wear-out condition, the Dallastat will still  
function properly while power is applied. However, on power-up the device’s wiper position will be that  
of the position last recorded before memory cell wear-out.  
4 of 8  
DS1869  
FLOWCHART: ONE-BUTTON OPERATION  
AND ELECTRICAL CONTROL Figure 3  
CONTACT OPEN AND CONTACT CLOSURE TIMING IS 1 SECOND ± 15%  
5 of 8  
DS1869  
FLOWCHART: TWO-BUTTON OPERATION Figure 4  
CONTACT OPEN AND CONTACT CLOSURE TIMING IS 1 SECOND ± 15%  
6 of 8  
DS1869  
ABSOLUTE MAXIMUM RATINGS*  
Voltage on Any Pin Relative to -V  
Operating Temperature  
-V -0.5V +8.0V  
-40°C to +85°C  
Storage Temperature  
Soldering Temperature  
-55°C to +125°C  
260°C for 10 seconds  
* This is a stress rating only and functional operation of the device at these or any other conditions  
above those indicated in the operation sections of this specification is not implied. Exposure to  
absolute maximum rating conditions for extended periods of time may affect reliability.  
RECOMMENDED DC OPERATING CONDITIONS  
(-40°C to +85°C)  
PARAMETER  
+ Supply Voltage  
- Supply Voltage  
Resistor Inputs  
Logic Input 1  
SYMBOL  
MIN  
-V + 2.7  
+V - 8.0  
-V - 0.5  
+2.4  
TYP  
MAX  
UNITS NOTES  
+V  
-V  
-V + 8.0  
+V - 2.7  
+V + 0.5  
V
V
V
RH,RW,RL  
VIH  
V
V
1, 2, 10  
1, 2, 10  
5
Logic Input 0  
VIL  
+0.8  
1
Wiper Current  
IW  
mA  
DC ELECTRICAL CHARACTERISTICS  
(-40°C to +85°C; -V to +V = 2.7V to 8.0V)  
PARAMETER  
SYMBOL  
MIN  
TYP  
MAX  
UNITS NOTES  
End to End Resistor Tolerance  
+, - Supply Current  
Supply Current, Idle State  
At 3.3V  
-20  
20  
%
11  
3
ICC1  
ICC2  
1
2
mA  
2
9
µA  
At 8.0V  
10  
Wiper Resistance  
Temperature Coefficient  
RW  
400  
750  
1000  
ppm/°C  
AC ELECTRICAL CHARACTERISTICS  
(-40°C to +85°C; -V to +V = 2.7V to 8.0V)  
PARAMETER  
SYMBOL  
tPW  
MIN  
TYP  
MAX  
UNITS NOTES  
Input Pulse Width (D-input)  
Contact Pulse Width  
(UC, DC inputs)  
1
1
DC  
1, 7, 8  
1, 7, 8  
µs  
tCPW  
DC  
ms  
Capacitance  
CIN  
tHPW  
tCCP  
5
10  
pF  
ms  
s
6
Repetitive Input Pulse High Time  
Continuous Input Pulse  
1
1
DC  
DC  
1, 7, 8  
1, 7, 8  
7 of 8  
DS1869  
TIMING DIAGRAMS Figure 5  
tCPW  
NOTES:  
1. All inputs; UC, DC, and D are internally pulled up with a typical resistance of 100 k.  
2. Input logic levels are referenced to -V.  
3. ICC is the internal current that flows between -V and +V.  
4. Input leakage applies to contact inputs UC and DC and the digital input (D).  
5. Wiper current is the maximum current which can flow through the wipers.  
6. Capacitance values apply at 25°C.  
7. Input pulse width is the minimum time required for an input to cause an increment or decrement. If  
the UC, DC, or D input is held active for longer than 1 second, subsequent increments or decrements  
will occur on 100 ms intervals until the inputs UC, DC, and/or D is released to VIH.  
8. Repetitive pulsed inputs on UC, DC, or D will be recognized as long as the pulse repetition occurs  
within 1 second of each other. Pulses occurring faster than 1 ms apart may not be recognized as  
individual inputs but can be interpreted a constant input. Tolerance for pulse timing is ±15% on  
minimum inputs.  
9. Idle state supply current is measured with no pushbutton pressed and with the wiper RW tied to a  
CMOS load.  
10. For +V referenced to -V = 5V.  
11. Valid at 25°C only.  
8 of 8  

相关型号:

DS1869-010

Digital Potentiometer
ETC

DS1869-050

Digital Potentiometer
ETC

DS1869-10

3V Dallastat Electronic Digital Rheostat
DALLAS

DS1869-100

3V Dallastat Electronic Digital Rheostat
DALLAS

DS1869-100

100K DIGITAL POTENTIOMETER, INCREMENT/DECREMENT CONTROL INTERFACE, 64 POSITIONS, PDIP8, 0.300 INCH, PLASTIC, DIP-8
ROCHESTER

DS1869-100+

Digital Potentiometer, 1 Func, 100000ohm, Increment/decrement Control Interface, 64 Positions, PDIP8, 0.300 INCH, ROHS COMPLIANT, PLASTIC, DIP-8
MAXIM

DS1869-50

3V Dallastat Electronic Digital Rheostat
DALLAS

DS1869-50

50K DIGITAL POTENTIOMETER, INCREMENT/DECREMENT CONTROL INTERFACE, 64 POSITIONS, PDIP8, 0.300 INCH, PLASTIC, DIP-8
ROCHESTER

DS1869-50

Digital Potentiometer, 1 Func, 50000ohm, Increment/decrement Control Interface, 64 Positions, PDIP8, 0.300 INCH, PLASTIC, DIP-8
MAXIM

DS1869-50+

Digital Potentiometer, 1 Func, 50000ohm, Increment/decrement Control Interface, 64 Positions, PDIP8, 0.300 INCH, ROHS COMPLIANT, PLASTIC, DIP-8
MAXIM

DS1869S-010

Digital Potentiometer
ETC

DS1869S-050

Digital Potentiometer
ETC