MDU12H-150M [DATADELAY]
DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H); DUAL , ECL -接口固定的延时线(系列MDU12H )型号: | MDU12H-150M |
厂家: | DATA DELAY DEVICES, INC. |
描述: | DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H) |
文件: | 总4页 (文件大小:33K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MDU12H
Ò
DUAL, ECL-INTERFACED
FIXED DELAY LINE
(SERIES MDU12H)
data
delay
3
devices, inc.
FEATURES
PACKAGES
GND
GND
O1
1
16
15
14
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
GND
O1
O2
N/C
N/C
N/C
N/C
N/C
GND
N/C
N/C
N/C
I1
I2
N/C
VEE
·
·
·
·
Two independent delay lines
Fits standard 16-pin DIP socket
Auto-insertable
O2
I1
I2
5
6
Input & outputs fully 10KH-ECL interfaced & buffered
VEE
8
MDU12H-xx DIP
MDU12H-xxC3 SMD
MDU12H-xxM Military DIP MDU12H-xxMC3 Mil SMD
PIN DESCRIPTIONS
FUNCTIONAL DESCRIPTION
I1-I2
O1-O2 Signal Outputs
VEE -5 Volts
GND Ground
Signal Inputs
The MDU12H-series device is a 2-in-1 digitally buffered delay line. The
signal inputs (I1-I2) are reproduced at the outputs (O1-O2), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
DASH NUMBER SPECIFICATIONS
SERIES SPECIFICATIONS
Part
Number
Delay Per
Line (ns)
3 ± 1.0
4 ± 1.0
5 ± 1.0
·
·
·
·
·
·
Minimum input pulse width: 50% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 200mw typical (no load)
Operating temperature: -30° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
MDU12H-3
MDU12H-4
MDU12H-5
MDU12H-10
MDU12H-15
MDU12H-20
MDU12H-25
MDU12H-30
MDU12H-35
MDU12H-40
MDU12H-45
MDU12H-50
MDU12H-60
MDU12H-75
MDU12H-100
MDU12H-125
MDU12H-150
MDU12H-200
MDU12H-250
10 ± 1.0
15 ± 1.0
20 ± 1.0
25 ± 2.0
30 ± 2.0
35 ± 2.0
40 ± 2.0
45 ± 2.2
50 ± 2.5
60 ± 3.0
75 ± 3.7
100 ± 5.0
125 ± 6.2
150 ± 7.5
200 ± 10.0
250 ± 12.5
O1
100%
I1
O2
100%
I2
VCC
GND
* Total delay is referenced to first tap output
Input to first tap = 1.5ns ± 1ns
Functional block diagram
NOTE: Any dash number between 3 and 50
not shown is also available.
Ó1997 Data Delay Devices
Doc #97038
12/12/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
MDU12H
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The MDU12H tolerances are guaranteed for
input pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 50% of the total delay and periods as
small as 100% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The MDU12H relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VEE
VIN
TSTRG
TLEAD
MIN
-7.0
VEE - 0.3
-55
MAX
0.3
0.3
150
300
UNITS NOTES
V
V
C
C
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 75C)
PARAMETER
SYMBOL
VOH
VOL
VIH
MIN
-1.020
-1.950
TYP
MAX
-0.735
-1.600
-1.070
UNITS
NOTES
VIH = MAX,50W to -2V
VIL = MIN, 50W to -2V
High Level Output Voltage
Low Level Output Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
V
V
V
V
mA
mA
VIL
IIH
IIL
-1.480
0.5
475
VIH = MAX
VIL = MIN
Doc #97038
12/12/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
2
MDU12H
PACKAGE DIMENSIONS
16 15 14
.400
TYP.
1
5
6
8
.800 TYP.
.320
MAX.
.020
TYP.
.150
±.030
.010 TYP.
.100
.018
TYP.
TYP.
.300
TYP.
.700 TYP.
MDU12H-xx (Commercial DIP)
MDU12H-xxM (Military DIP)
.020 TYP.
.040
.010±.002
TYP.
16 15 14 13 12 11 10
9
.882
±.005
.710 .590
MAX.
±.005
.007
±.005
1
2
3
4
5
6
7
8
.090
.100
.280
MAX.
.050
±.010
.700
.880±.020
MDU12H-xxC3 (Commercial SMD)
MDU12H-xxMC3 (Military SMD)
Doc #97038
12/12/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
MDU12H
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
OUTPUT:
Ambient Temperature: 25oC ± 3oC
Supply Voltage (Vcc): -5.0V ± 0.1V
Load:
Cload
50W to -2V
5pf ± 10%
:
Input Pulse:
Standard 10KH ECL
Threshold: (VOH + VOL) / 2
levels
(Rising & Falling)
Source Impedance:
Rise/Fall Time:
50W Max.
2.0 ns Max. (measured
between 20% and 80%)
PWIN = 1.5 x Total Delay
PERIN = 10 x Total Delay
Pulse Width:
Period:
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
REF
PULSE
GENERATOR
OUT
I1
I2
O1
O2
IN
OSCILLOSCOPE
TRIG
DEVICE UNDER
TEST (DUT)
TRIG
Test Setup
PERIN
PWIN
VIH
TRISE
TFALL
INPUT
SIGNAL
80%
50%
20%
80%
50%
20%
VIL
TRISE
TFALL
OUTPUT
SIGNAL
VOH
50%
50%
VOL
Timing Diagram For Testing
Doc #97038
12/12/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
4
相关型号:
©2020 ICPDF网 联系我们和版权申明