27CP-R-PC-CF [DDK]

75 Ω SMB Style Coaxial Connector;
27CP-R-PC-CF
型号: 27CP-R-PC-CF
厂家: DDK LTD.    DDK LTD.
描述:

75 Ω SMB Style Coaxial Connector

文件: 总5页 (文件大小:786K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
75 Ω SMB Style Coaxial Connector  
27CP Series  
FEATURE  
・27CP series is a SMB connector which  
corresponding to 75 Ω .  
・Low profile coaxial connector with push on lock  
mechanism. It is suitable to the applications of  
internal equipments.  
Frequency  
Range  
DC to 500MHz  
・Push-on locking mechanism provides quick and  
reliable connection.  
・Incompatible to 27DPseries(50 Ω SMB connector)  
Characteristic  
Impedance  
APPLICATIONS  
Measurement equipments, Broadcasting, CATV, HDTV  
75 Ω  
Lock Type  
SPECIFICATIONS  
Push On  
Characteristic Impedance  
Rated Voltage  
ꢀ75 Ω  
500VAC(r.m.s.)  
Dielectric Withstanding Voltage 1000V AC(r.m.s.)for1 minute  
Insulation Resistance  
Contact Resistance  
V.S.W.R.  
1000M Ω Mim. at 500V DC  
6m Ω Max.  
1.5 max. at DC to 500MHz  
-40 〜 +85℃  
Operating Temperature  
* The specifications are typical but may not apply to all connectors. Please check ꢀ  
the specifications on each item with its drawing from us when you use.  
RRooHHSS  
MATERIAL/FINISH  
CCoommpplliiaanntt  
Item  
Material / Finish  
Copper Alloy / Ni or Au Plating  
Copper Alloy / Au Plating  
Shell (Body)  
Contact (Male)  
Contact (Female) Copper Alloy / Au Plating  
Insulator  
PTFE  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
121226  
http://www.ddknet.co.jp  
27CP Series  
Unit:mm  
○ Straight Cable Plug  
Finish  
Center  
Conductor Conductor  
Applicable  
Cable  
Assembly  
Part Number  
Crimp Tool  
Outer  
Instruction  
27CP-P-1.5-CF  
27CP-P-1.5W-CF  
27CP-P-2.5-CF  
1.5C−2V  
1.5C−2W  
2.5C−2V  
Ni  
Ni  
Ni  
Au  
Au  
Au  
1
1
CR-H-1100  
CR-H-1100  
CR-H-1100  
16.5  
○ Right Angle Cable Plug  
7.9  
Finish  
Applicable  
Cable  
Assembly  
Part Number  
φA  
L1  
L2  
Crimp Tool  
Outer  
Center  
Instruction  
Conductor Conductor  
27CP-LP-1.5-CF  
1.5C−2V  
5.5 14.40 15.5  
5.5 14.35 15.5  
Ni  
Au  
2
CR-H-1100  
CR-H-1100  
1.5C−2W  
1.5C−2WX  
27CP-LP-1.5W-CF  
Ni  
Au  
27CP-LP-2.5W-CF 2.5C−2W  
6.0 14.35 15.5  
5.5 14.40 15.5  
Ni  
Ni  
Au  
Au  
CR-H-15285  
CR-H-1100  
φA  
L2  
27CP-LP-2.5-CF 2.5C−2V  
2
○ Straiught Balkhead Cable Jack  
1.2  
6.5  
9.5  
L
Mounting Panel Thickness:2.4mm max.  
φ8.4  
Panel Mounting Dimensions  
Finish  
Applicable  
Cable  
Assembly  
Part Number  
φA  
L
Crimp Tool  
Outer  
Center  
Instruction  
Conductor Conductor  
27CP-BJ-1.5-CF  
27CP-BJ-1.5W-CF  
27CP-BJ-2.5-CF  
27CP-BJ-2.5W-CF  
1.5C−2V  
1.5C−2W  
2.5C−2V  
2.5C−2W  
5.5  
5.5  
5.5  
6.0  
17.10  
17.07  
17.10  
17.00  
Ni  
Ni  
Ni  
Ni  
Au  
Au  
Au  
Au  
CR-H-1100  
CR-H-1100  
CR-H-1100  
CR-H-15285  
1
Straiught Bulkhead Receptacle  
1.2  
0.5  
10.7  
9.5  
φ8.4  
Mounting Panel Thickness:2.4mm max.  
14.8  
Panel Mounting Dimensions  
Finish  
Outer  
Conductor  
Ni  
Center  
Part Number  
27CP-BR-CF  
Conductor  
Au  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
2
27CP Series  
Unit:mm  
○ Right Angle Receptacle Jack  
Finish  
Part Number  
Outer  
Center  
Conductor  
Ni  
Conductor  
Au  
27CP-LR-PC-CF  
15.5  
5.08  
□8  
2.54±0.05  
+0.1  
5.08±0.1  
5-φ1.3 0  
Panel Mounting Dimensions  
○ Receptacle Jack  
□0.8  
Finish  
Part Number  
27CP-R-PC-CF  
Outer  
Conductor  
Ni  
Center  
Conductor  
Au  
1.27  
5.08  
8.0  
7.5  
10.4  
2.54±0.05  
+0.1  
5-φ1.3 0  
5.08±0.1  
Panel Mounting Dimensions  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
3
27CP Series  
Unit:mm  
Assembly Instruction(1)  
Cut the cable as fig.1.  
The cable length require for the cable assembly  
L=L1+A+3  
L1  
A
3
Part Number  
27CP-P-1.5-CF  
27CP-P-2.5-CF  
A
6.4mm  
6.4mm  
8.0mm  
27CP-BJ-1.5W-CF  
Ferule  
Ferule  
② Insert the ferule between outer conductor and  
sheath when the cable is 2.5C-2V.  
Insert the ferule until ferule contacts with the  
sheath when the cable is 1.5C-2V.  
2.5C-2V  
1.5C-2V  
③ Pick the outer conductor and turn down to the  
ferule. Cut the extra outer conductor along the  
ferule. Cut the center conductor as fig.3.  
B
C
Please be careful to not damage the center  
conductor. Pre-solder the center conductor.  
B
C
Part Number  
27CP-P-1.5-CF  
27CP-P-2.5-CF  
B
C
2.0mm  
2.0mm  
2.0mm  
1.6mm  
1.6mm  
3.0mm  
27CP-BJ-1.5W-CF  
④ Insert the contact and solder from side hole.  
Please be careful to not make gap between  
contact and center conductor of the cable and  
not damage the insulator by heat. When the  
solder is stick out, please shave the extra solder  
along the contact. Insert the heat-shrinkable  
tube.  
Soldering  
Heat-shrinkable tube  
and  
⑤ Insert the above contact into the body  
crimp the root of the body as fig.5.  
Same level  
Cover the heat shrinkable tube on the root of the  
body and heat up.  
Finish  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
4
27CP Series  
Unit:mm  
Assembly Instruction(2)  
① Cut the cable as fig.1.  
The cable length require for the cable assembly  
L=L1+15+3  
L1  
15.0  
3
Ferule  
Ferule  
② Insert the ferule between outer conductor and  
sheath when the cable is 2.5C-2V.  
Insert the ferule until ferule contacts with the  
sheath when the cable is 1.5C-2V.  
2.8  
③ Pick the outer conductor and turn down to the  
ferule. Cut the extra outer conductor along the  
ferule. Cut the center conductor as fig.3.  
Please be careful to not damage the center  
conductor. Pre-solder the center conductor.  
2.8  
and insert the  
center conductor into the body as fig.4.  
Crimp the root of the body.  
④ Insert the boot into the cable  
Rear Insulator  
⑤ Insert the rear insulator into the center  
conductor.  
Soldering  
Cut the center conductor in 1.6mm and pre-  
soldering.  
Insert the contact and solder.  
Front Insulator  
⑥ Insert the front insulator into the contact and  
twist in the interface.  
Cover the heat-shrinkable tube and heat up.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
5

相关型号:

27CP-SP-2.5C2V-CR1

75Ω SMB Type Connectors
DDK

27CP-SP-2.5C2V-CR1-2

75Ω SMB Type Connectors
DDK

27CP-SP-2.5C2W-CR1

75Ω SMB Type Connectors
DDK

27CP-SP-2.5C2W-CR1-2

75Ω SMB Type Connectors
DDK

27CP-SP-3C2V-CR1

75Ω SMB Type Connectors
DDK

27CP-SP-3C2W-CR1

75Ω SMB Type Connectors
DDK
ETC
ETC
ETC
ETC
ETC
ETC