N-J-58U-CF [DDK]

RF N Connector, 1 Contact(s), Locking, Plug;
N-J-58U-CF
型号: N-J-58U-CF
厂家: DDK LTD.    DDK LTD.
描述:

RF N Connector, 1 Contact(s), Locking, Plug

文件: 总15页 (文件大小:299K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
N Style Coaxial Connector  
N Series  
FEATURE  
Characteristic  
Impedance  
N series is a thread coupling coaxial connector  
which isꢀthe most popular as a 7mm type 50 Ω  
impedance.  
50 Ω  
・N series is available for various cable type.  
・It is incompatible to NC series(75 Ω impedance N  
Style connector).  
Frequency  
Range  
DC to 3GHz  
Lock Type  
Screw  
CONFORMING STANDARD  
JIS-C5411,MIL-PRF-39012  
SPECIFICATIONS  
Characteristic Impedance  
50 Ω  
Dielectric Withstanding Voltage 1,500V AC(r.m.s) / 1 minute  
Insulation Resistance  
Contact Resistance  
V.S.W.R.  
1,000M Ω min. at 500V DC  
3m Ω max.  
1.3 max. (DC ~ 3GHz)  
* The specifications are typical but may not apply to all connectors.  
Please check the specifications on each item with its drawing from us when you use.  
Also, the performance is diffrenet by using cable.  
RRooHHSS  
CCoommpplliiaanntt  
MATERIAL/FINISH  
Item  
Shell  
Contact (Female)  
Contact (Male)  
Insulator  
Material / Finish  
Copper Alloy / Ni or Ag Plating  
Copper Alloy / Ag or Au Plating  
Copper Alloy /Ag or Au Plating  
PTFE  
Gasket  
Silicon Rubber  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
111021  
http://www.ddknet.co.jp  
Unit:mm  
NꢀSeries  
○ Straight Cable Plug  
Finish  
Applicable  
Cable  
Clamp Type  
Assembly  
Instruction  
Part Number  
φAL)  
Outer  
Center  
Conductor Conductor  
3C-2V  
3D-2V  
N-P-3-CF  
6.2 44.6  
6.2 44.6  
6.2 44.6  
7.2 44.6  
7.2 44.6  
7.2 44.6  
Ag  
Ag  
Ag  
Au  
Ag  
Ag  
Au  
1
1
1
1
1
1
3C-2V  
N-P-3-Ni-CF  
Ni  
3D-2V  
3C-2V  
N-P-3-NiCAu-CF  
N-P-3W-CF  
Ni  
3D-2V  
(L)  
3C-2W  
3D-2W  
3C-2W  
3D-2W  
3C-2W  
3D-2W  
RG-55/U  
RG-55/U  
RG-58/U  
RG-58/U  
RG-58/U  
Ag  
Ni  
N-P-3W-Ni-CF  
N-P-3W-D1-CF  
Ni  
N-P-55U-CF  
5.4 44.6  
5.4 44.6  
5.4 44.6  
5.4 44.6  
5.4 44.6  
Ag  
Ni  
Ag  
Ag  
Ag  
Ag  
Au  
1
1
1
1
1
N-P-55U-Ni-CF  
N-P-58U-CF  
Ag  
Ni  
N-P-58U-Ni-1-CF  
N-P-58U-NiCAu-CF  
Ni  
Finish  
Center  
Conductor Conductor  
Applicable  
Cable  
Assmbly  
Instruction  
Part Number  
φA (L)  
Outer  
3.5D-FE  
3.5D-QEFA  
5C-2V  
N-SP-3.5DFE-CF  
N-P-5-CF  
6.2 41.5  
8.6 44.0  
8.6 44.0  
9.1 45.0  
9.1 45.0  
9.1 45.0  
Ni  
Ag  
Ni  
Au  
Ag  
Ag  
Ag  
Ag  
Au  
1
1
1
1
1
(L)  
5D-2V  
5C-2V  
N-P-5-Ni-CF  
5D-2V  
5C-2W  
5D-2W  
5C-2W  
5D-2W  
5C-2W  
5D-2W  
5D-FB  
N-P-5W-CF  
Ag  
Ni  
N-P-5W-Ni-CF  
N-P-5W-NiCAu-CF  
Ni  
N-P-5DFB-1-CF  
N-SP-5DSFA-CF  
8.1 44.0  
8.6 41.5  
Ni  
Ni  
Ag  
Au  
1
5D-SFA  
RG-8/U  
RG-9/U  
RG-8/U  
RG-9/U  
RG-8/U  
RG-9/U  
N-P-8U-CF  
11.2 44.0  
11.2 44.0  
11.25 38.0  
Ag  
Ni  
Ag  
Ag  
Ag  
1
1
2
N-P-8U-Ni-CF  
UG-21D/U-CF  
Ag  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
2
Unit:mm  
NꢀSeries  
○ Straight Plug  
Clamp Type  
Finish  
Outer  
Applicable  
Cable  
Assembly  
Part Number  
N-P-8-1-CF  
φA  
Center  
Instruction  
Conductor Conductor  
8D-2V  
8D-2V  
8D-FB  
12.6  
12.6  
11.8  
Ag  
Ag  
Ag  
Ag  
4
4
N-P-8-1-Ni-CF  
Ni  
(38.0)  
N-P-8DFB-1-CF  
Ni  
Finish  
Applicable  
Cable  
Assembly  
Part Number  
N-P-10-CF  
φA  
Outer  
Center  
Instruction  
Conductor Conductor  
10C-2V  
10D-2V  
10C-2V  
10D2V  
10D-FB  
14.2  
Ag  
Ag  
4
N-P-Ni-CF  
14.2  
14.2  
Ni  
Ni  
Ag  
Ag  
4
4
(51.7)  
N-P-10DFB-1-CF  
Crimp Type  
Finish  
Applicable  
Cable  
Assembly Crimp  
Part Number  
φA (L)  
Outer  
Center  
Instruction  
Tool  
ConductorConductor  
3D-2V  
3D-LFV  
5D-2V  
N-P-3D2V-CR20-CF  
N-P-5D2V-CR20-CF  
7.1 35.0  
9.5 37.2  
Ni  
Ni  
Ag  
Ag  
6
7
CR-H-1152  
CR-H-1130  
(L)  
Above drawing is N-P-5D2V-CR20-CF.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
3
Unit:mm  
NꢀSeries  
○ Right Angle Cable Plug  
Clamp Type  
φ21  
Finish  
Center  
ConductorConductor  
Applicable  
Cable  
Assembly  
Part Number  
φA (L1)(L2)  
Outer  
Instruction  
N-LP-58U-CF  
RG-58/U  
RG-58/U  
5.4 52.9 36.6  
5.4 52.9 36.6  
Ag  
Ag  
N-LP-58U-Ni-CF  
Ni  
Ag  
(L1)  
Finish  
Center  
ConductorConductor  
φ21  
Applicable  
Cable  
Assembly  
Part Number  
φAL1)(L2)  
Outer  
Instruction  
N-LP-5-CF  
5D-2V  
5D-2V  
8.6 53.0 36.6  
8.6 53.0 36.6  
Ag  
Ag  
N-LP-5-Ni-CF  
Ni  
Ag  
(L1)  
Finish  
Applicable  
Cable  
Assembly  
Instruction  
φ21  
Part Number  
Outer  
Center  
Conductor Conductor  
RG-8U  
RG-9/U  
RG-8U  
RG-9/U  
N-LP-8U-CF  
Ag  
Ag  
N-LP-8U-Ni-CF  
Ni  
Ag  
(47.0)  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
4
Unit:mm  
NꢀSeries  
Straight Cable Jack  
Clamp Type  
Finish  
Applicable  
Cable  
Assembly  
Instruction  
Part Number  
φA  
Outer  
Center  
Conductor Conductor  
3C-2V  
3D-2V  
N-J-3-CF  
6.2  
6.2  
Ag  
Ag  
2
2
(46)  
3C-2V  
N-J-3-Ni-CF  
Ni  
Ag  
3D-2V  
N-J-58U-CF  
RG-58/U  
RG-58/U  
5.4  
5.4  
Ag  
Ni  
Ag  
Ag  
2
2
N-J-58U-Ni-CF  
Finish  
Applicable  
Cable  
Assembly  
Part Number  
φA (L)  
Outer  
Center  
Instruction  
Conductor Conductor  
N-J-5-CF  
5D-2V  
5D-2V  
8.6  
8.6  
47.0  
47.0  
Ag  
Ag  
2
2
(L)  
N-J-5-Ni-CF  
Ni  
Ag  
RG-8/U  
RG-9/U  
RG-8/U  
RG-9/U  
N-J-8U-CF  
11.2 47.0  
11.2 47.0  
Ag  
Ni  
Ag  
Ag  
2
2
N-J-8U-Ni-CF  
Finish  
Applicable  
Cable  
Assembly  
Part Number  
φA φB (L)  
Outer  
Center  
Instruction  
Conductor Conductor  
N-J-8-1-CF  
8D-2V  
8D-2V  
12.7 19.1 41.2  
12.7 19.1 41.2  
Ag  
Ag  
5
5
N-J-8-1-Ni-CF  
Ni  
Ag  
(L)  
RG-8/U  
RG-9/U  
UG-23D/U-CF  
11.2 19.0 40.0  
Ag  
Ag  
5
Finish  
Applicable  
Cable  
Assembly  
Part Number  
N-J-10-CF  
φA φB  
14.2 22.2  
Outer  
Center  
Instruction  
Conductor Conductor  
10C-2V  
10D-2V  
10C-2V  
10D-2V  
10D-FB  
Ag  
Ag  
5
(52.7)  
N-J-10-Ni-CF  
14.2 22.2  
14.2 22.2  
Ni  
Ni  
Ag  
Ag  
5
5
N-J-10DFB-1-CF  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
5
Unit:mm  
NꢀSeries  
○ Straight Panel Cable Jack  
4-φ3.2  
Finish  
2.0  
B
Applicable  
Cable  
Assembly  
Instruction  
Part Number  
φA  
B
C
Outer  
Center  
Conductor Conductor  
3C-2V  
3D-2V  
N-PJ-3-CF  
6.2  
6.2  
16.7 18.2  
16.7 18.2  
Ag  
Ag  
3
3C-2V  
C
N-PJ-3-Ni-CF  
Ni  
Ag  
3
(46)  
□25.4  
3D-2V  
N-PJ-55U-CF  
RG-55/U  
RG-55/U  
RG-58/U  
RG-58/U  
5.4  
5.4  
5.4  
5.4  
16.6 18.2  
16.6 18.2  
16.6 18.2  
16.6 18.2  
Ag  
Ni  
Ag  
Ag  
Ag  
Ag  
3
3
3
3
+0.1  
0
N-PJ-55U-Ni-CF  
N-PJ-58U-CF  
4-φ3.2  
Ag  
Ni  
N-PJ-58U-Ni-CF  
+0.1  
0
φ17.8  
±0.05  
18.2  
Panel Mounting Dimensions  
Finish  
Applicable  
Cable  
Assembly  
Instruction  
4-φ3.2  
2.0  
C
Part Number  
φA  
B
C
D
Outer  
Center  
Conductor Conductor  
5C-2V  
5D-2V  
5D-2V  
N-PJ-5-CF  
8.6  
8.6  
17.5 16.7 18.24  
17.5 16.7 18.24  
Ag  
Ni  
Ag  
Ag  
3
3
N-PJ-5-Ni-CF  
D
(47)  
□25.4  
+0.1  
0
4-φ3.2  
+0.1  
0
φ18.0  
±0.05  
18.24  
Panel Mounting Dimensions  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
6
Unit:mm  
NꢀSeries  
Receptacle Jack  
4-φA  
Finish  
Part Number  
N-R-CF  
L
φ A  
Outer  
Center  
Conductor Conductor  
29  
29  
29  
29  
Ag  
Ag  
Ag  
Au  
Ag  
φ 3.2  
φ 3.2  
φ 3.2  
φ 3.2  
N-R-Ni-CF  
Ni  
N-R-NiCAu-CF  
UG-58A/U-CF  
Ni  
2
18.2  
Ag  
18.7  
□25.4  
L
+0.1  
0
4-φ3.2  
+0.1  
0
φ15.0  
±0.05  
18.2  
Panel Mounting Dimensions  
Dust Cap  
5/8-24UNEF-2B  
(φ3.5)  
Part Number  
Finish  
Ni  
N-RC-5  
N-RC-5-D1  
Ag  
(60)  
(71)  
5/8-24UNEF-2B  
Part Number  
N-RC-3-CF  
Finish  
Ni  
11.1  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
7
Unit:mm  
NꢀSeries  
Assembly Instruction(1) Straight Cable Plug  
Parts Configulration  
Contact  
Insulator  
Ring  
Nut  
Washer  
Gasket  
Clamp  
Body  
The Cable length require for the single-ended  
cable assembly.  
① L=  
L=L1-10  
L1  
Outer  
Sheath  
Conductor  
Insert the nut, washer and gasket into the cable.  
ꢀ Cut the sheath 15mm from the end of the cable  
and insert the clamp.  
Please be careful to not damage the outer  
conductor.  
15mm  
Gasket  
Washer  
Clamp  
Nut  
Pick the outer conductor and turn  
down to the clamp equally.  
Pick the outer conductor and turn down to the  
clamp. Cut the outer conductor along the clamp.  
Cut the insulator and center conductor as fig.3.  
Please be careful to not damage the center  
conductor.  
Insulator  
Canter Conductor  
(Pre-soldering)  
5.0mm  
3.5~4.0mm  
3.5mm  
Solder up the contact with the center conductor.  
Please be careful to not deform the  
insulator by heat.  
When the solder is stick out, please shave  
the extra solder.  
No gap between contact and insulator of  
the cable.  
Soldering  
Contact  
No gap  
Insert the ring and insulator as fig. 5.  
Ring  
Insulator  
Insert the above assembly into the body and screw  
up by wrench.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
8
Unit:mm  
NꢀSeries  
Assembly Instruction(2) Straight Cable Jack  
Parts Configulration  
Washer  
Body  
Washer  
Clamp  
Insulator  
Contact  
Gasket  
Nut  
The Cable length require for the single-ended  
cable assembly.  
① L=  
L=L1-12  
L
1
Nut  
Gasket  
Outer  
Conductor  
Insert the nut, washer and gasket into the cable.  
ꢀCut the sheath 15mm from the end of the cable  
and insert the calmp.  
Please be careful to not damage the outer conductor .  
Cable  
15mm  
Washer  
Center Conductor  
(Pre-soldering)  
Insulator  
Pick the outer conductor and turn down to the  
clamp. Cut the outer conductor along the clamp.  
Cut the insulator and center conductor as fig.3.  
Please be careful to not damage the center  
conductor.  
Clamp  
3.5~4mm  
3.5mm  
mm  
5
Contact  
Soldering  
Solder up the contact with the center conductor.  
Please be careful to not deform the  
insulator by heat.  
When the solder is stick out, please shave the  
extra solder.  
No gap between contact and insulator of  
the cable.  
No gap  
Washer  
Inser the washer and insulator as fig.5.  
Insulator  
Insert the above assembly into the body and screw  
up by wrench.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
9
Unit:mm  
NꢀSeries  
Assmbly Instruction(3Straight Panel Jack  
Parts Configulration  
Washer  
Body  
Washer  
Clamp  
Insulator  
Contact  
Gasket  
Nut  
The Cable length require for the single-ended  
① L=  
cable assembly.  
1
L=L -6.7  
L
1
ꢀꢀ L=-L -1.2  
2
L
2
Nut  
Gasket  
Outer  
Conductor  
Insert the nut, washer and gasket into the cable.  
ꢀ Cut the sheath 15mm from the end of the cable  
and insert the clamp.  
Please be careful to not damage the outer  
conductor.  
mm  
15  
Cable  
Washer  
Insulator Center Conductor  
(Pre-soldering)  
Pick the outer conductor and turn down to the  
clamp. Cut the outer conductor along the clamp.  
Cut the insulator and center conductor as fig.3.  
Please be careful to not damage the center  
conductor.  
Clamp  
3.5~4mm  
3.5mm  
5mm  
Contact  
Soldering  
Solder up the contact with the center conductor.  
ꢀ Please be careful to not deform the insulator  
by heat.  
When the solder is stick out, please shave the extra  
solder.  
No gap  
No gap between contact and insulator of the cable.  
Washer  
Insert the washer and insulator as fig. 5.  
Insulator  
Insert the above assembly into the body and screw  
up by wrench.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
10  
Unit:mm  
NꢀSeries  
Assembly Instruction(4MIL Clamp Straigh Cable Plug  
Parts Configulration  
Nut  
Gasket  
※Washer  
Clamp  
Body  
Contact  
※ As for N-P-8-1-CF, N-P-8-1-Ni-CF and UG-21D/U-CF,  
washer is not attached. The washer is not inserted into the cable.  
The cable length require for the single-ended  
cable assembly as following table.  
Part Number  
ꢀN-P-8-1-CF  
ꢀN-P-8-1-Ni-CF  
ꢀUG-21D/U-CF  
ꢀN-P-10-CF  
L(mm)  
L
1
ꢀꢀꢀL ー11.4  
1
ꢀN-P-10-Ni-CF  
ꢀN-P-10DFB-1-CF  
ꢀꢀꢀL ー21.5  
1
Outer  
Washer  
Sheath  
Conductor  
Insert the nut, washer and gasket into the cable.  
ꢀ Cut the sheath 10mm from the end of the cable  
and insert the clamp.  
Please be careful to not damage the outer  
conductor.  
10mm  
Clamp  
Gasket  
Nut  
Pick the outer conductor and turn down to the  
clamp. Cut the outer conductor along the clamp.  
Cut the insulator and center conductor as fig.3.  
Please be careful to not damage the center  
conductor.  
Tip the outer conductor and  
turn down to the clamp equally.  
Insulator  
Center Conductor  
(Pre-soldering)  
Part Number  
A(mm)  
B(mm)  
N-P-8-1-CF  
N-P-8-1-Ni-CF  
UG-21D/U-CF  
1.0  
3.5 ~ 4.0  
B
5.0mm  
A
N-P-10-CF  
N-P-10-Ni-CF  
N-P-10DFB-1-CF  
1.8  
4.0 ~ 4.5  
Soldering  
Contact  
Solder up the contact with the center conductor.  
Please be careful to not deform the insulator  
by heat.  
No gap  
When the solder is stick out, please shave  
the extra solder.  
No gap between contact and insulator of  
the cable.  
Insert the above assembly into the body and screw  
up by wrench.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
11  
Unit:mm  
NꢀSeries  
Assembly Instruction(5MIL Clamp Straight Cable Jack  
Parts Configulration  
Nut  
Gasket  
Calmp  
Contact  
Body  
※Washer  
※ As for N-J-8-1-CF, N-J-8-1-Ni-CF and UG-23D/U-CF,  
the washer is not attached. The washer is not inserted into the cable.  
The cable length require for the single-ended  
cable assembly as following table.  
Part Number  
ꢀN-J-8-1-CF  
ꢀN-J-8-1-Ni-CF  
ꢀUG-23D/U-CF  
ꢀN-J-10-CF  
L(mm)  
ꢀꢀꢀL ー13.2  
L
1
1
L ー13.8  
1
Washer  
Sheath  
Outer conductor  
Clamp  
ꢀN-J-10-Ni-CF  
ꢀN-J-10DFB-1-CF  
ꢀꢀꢀL ー23.4  
1
Insert the nut, washer and gasket into the cable.  
ꢀ Cut the sheath 10mm from the end of the cable  
and insert the clamp.  
10mm  
Nut  
Gasket  
Please be careful to not damage the outer  
conductor.  
Pick the outer conductor and  
turn down to the clamp equally/ Insulator  
Pick the outer conductor and turn down to the  
clamp. Cut the outer conductor along the clamp.  
Cut the insulator and center conductor as fig.3.  
Please be careful to not damage the center  
conductor.  
Outer Conductor  
(Pre-soldering)  
mm  
5
Part Number  
A(mm)  
B(mm)  
A
B
N-J-8-1-CF  
N-J-8-1-Ni-CF  
UG-23D/U-CF  
1.0  
3.5 ~ 4.0  
Soldering  
Contact  
N-J-10-CF  
N-J-10-Ni-CF  
N-J-10DFB-1-CF  
1.8  
4.0 ~ 4.5  
No gap  
Solder up the contact with the center conductor.  
Please be careful to not deform the insulator  
by heat.  
When the solder is stick out, please shave  
the extra solder.  
No gap between contact and insulator of  
the cable.  
Insert the above assembly into the body and screw  
up by wrench.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
12  
Unit:mm  
NꢀSeries  
Assembly Instruction(6) Crimp Straight Cable Plug  
Parts Configulration  
Gasket  
Ferule  
Boot  
Body  
Sleeve  
Contact  
Insulator  
Coupling Ring  
The cable length require for the single-ended cable  
assembly.  
L+17mm  
L
as  
Insert the boot into the cable. Cut the cable  
fig.2. Please be careful to not damage the outer  
conductor.  
Sheath  
Boot  
Outer conductor  
12.4mm  
Cable  
Inserting the ferule, tip the outer  
③ After  
Ferule  
conductor and spread the top of the outer  
conductor. Insert the sleeve between outer  
conductor and the insulator.  
Insulator  
Sleeve  
Cut the insulator along the sleeve.  
ꢀ And cut the outer conductor along the sleeve.  
Outer Conductor  
Sleeve  
Put the contact into the center hole of the crimp tool and  
insert the cable assembly and crimp the contact as  
fig.5.ꢀꢀ  
Center hole  
ꢀ ● Crimp Tool : CR-H-1152  
Tool  
Insulator  
Center conductor  
(3mm)  
Contact  
Tool  
Insert the above cable assembly into the body and crimp  
as fig.6. Body end is leveled to the tool end.  
● Crimp Tool : CR-H-1152  
Tool end  
Body end  
Body  
Tool  
Screw up the cable assembly into the body until the  
reverse thread is end and reached hollow .  
After the coupling ring is screwed, fit the gasket into  
the screw clearance. Cover the boot on the root of the  
connector.  
Screw  
clearance  
Reverse thread  
Gasket  
Coupling ring  
Boot  
Hollow  
Interface  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
13  
Unit:mm  
NꢀSeries  
○ Assembly Instruction(7) Crimp Straight Cable Plug  
Parts Configulration  
Contact  
Sleeve  
Ferule  
Boot  
Gasket  
Body  
Coupling Ring  
The cable length require for the single-ended cable  
assembly.  
L+22mm  
L
as  
Insert the boot into the cable. Cut the cable  
fig.2. Please be careful to not damage the outer  
conductor.  
15mm  
Outer Conductor  
Sheath  
Boot  
Cable  
After Inserting the ferule, tip the outer  
Ferule  
conductor and spread the top of the outer  
conductor. Insert the sleeve between outer  
conductor and the insulator. Plunge the sleeve  
by stripper without diging the edge.  
Sleeve  
Insulator  
● Stripper Part No. : 357J-15485  
Pull out the edge  
Stripper  
Push this side  
Cut the insulator by stripper as fig.4.  
Insert the stripper and dig the edge to the  
insulator. Rotate the stripper a few times and pull  
ꢀ off the insulator.  
ꢀ And cut the outer conductor along the sleeve.  
Cut off the round  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
14  
Unit:mm  
NꢀSeries  
Assembly Instruction(7) Crimp Straight Cable Plug  
Put the contact into the center hole of the crimp tool and  
insert the cable assembly and crimp the contact as  
fig.5.ꢀꢀ  
Center hole  
Tool  
● Crimp Tool : CR-H-13970  
Center Conductor  
3.0mm  
5.6mm  
Contact  
Tool  
Insert the above cable assembly into the body and crimp  
as fig.6. Body end is leveled to the tool end.  
Tool end  
Body  
Body end  
Tool  
Screw  
clearance  
Screw up the cable assembly into the body until the  
reverse thread is end and reached hollow .  
After the coupling ring is screwed, fit the gasket into  
the screw clearance. Cover the boot on the root of the  
connector.  
Gasket  
Coupling Ring  
Reverse thread  
Boot  
Interface  
Hollow  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
15  

相关型号:

N-JB-F-25DV

RF N Connector, Female, Panel Mount, Cable Mount, Jack
JAE

N-JB1-F-25DV

RF N Connector, Female, Panel Mount, Cable Mount, Jack
JAE

N-LA-PJ

Conversion Connector
DDK

N-LA-PJ-CF

RF ADAPTERS
DDK

N-LA-PJ-NI

Conversion Connector
DDK

N-LA-PJ-Ni-CF

RF ADAPTERS
DDK

N-LP-58U(40)

RF N Connector
HRS

N-LP-58U-CF

RF N Connector, 1 Contact(s), Locking, Plug
DDK

N-LP-5DW

RFCO-AXIAL CONNECTORS
HRS

N-LP-5DW(40)

RF N Connector
HRS

N-LP-5DW_17

50 ohms wide varieties standard connectors
HRS

N-P-141

RFCO-AXIAL CONNECTORS
HRS