N-J-58U-CF [DDK]
RF N Connector, 1 Contact(s), Locking, Plug;型号: | N-J-58U-CF |
厂家: | DDK LTD. |
描述: | RF N Connector, 1 Contact(s), Locking, Plug |
文件: | 总15页 (文件大小:299K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
N Style Coaxial Connector
N Series
FEATURE
Characteristic
Impedance
・N series is a thread coupling coaxial connector
which isꢀthe most popular as a 7mm type 50 Ω
impedance.
50 Ω
・N series is available for various cable type.
・It is incompatible to NC series(75 Ω impedance N
Style connector).
Frequency
Range
DC to 3GHz
Lock Type
Screw
CONFORMING STANDARD
JIS-C5411,MIL-PRF-39012
SPECIFICATIONS
Characteristic Impedance
50 Ω
Dielectric Withstanding Voltage 1,500V AC(r.m.s) / 1 minute
Insulation Resistance
Contact Resistance
V.S.W.R.
1,000M Ω min. at 500V DC
3m Ω max.
1.3 max. (DC ~ 3GHz)
* The specifications are typical but may not apply to all connectors.
Please check the specifications on each item with its drawing from us when you use.
Also, the performance is diffrenet by using cable.
RRooHHSS
CCoommpplliiaanntt
MATERIAL/FINISH
Item
Shell
Contact (Female)
Contact (Male)
Insulator
Material / Finish
Copper Alloy / Ni or Ag Plating
Copper Alloy / Ag or Au Plating
Copper Alloy /Ag or Au Plating
PTFE
Gasket
Silicon Rubber
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
111021
http://www.ddknet.co.jp
Unit:mm
NꢀSeries
○ Straight Cable Plug
Finish
Applicable
Cable
Clamp Type
Assembly
Instruction
Part Number
φA(L)
Outer
Center
Conductor Conductor
3C-2V
3D-2V
N-P-3-CF
6.2 44.6
6.2 44.6
6.2 44.6
7.2 44.6
7.2 44.6
7.2 44.6
Ag
Ag
Ag
Au
Ag
Ag
Au
1
1
1
1
1
1
3C-2V
N-P-3-Ni-CF
Ni
3D-2V
3C-2V
N-P-3-NiCAu-CF
N-P-3W-CF
Ni
3D-2V
(L)
3C-2W
3D-2W
3C-2W
3D-2W
3C-2W
3D-2W
RG-55/U
RG-55/U
RG-58/U
RG-58/U
RG-58/U
Ag
Ni
N-P-3W-Ni-CF
N-P-3W-D1-CF
Ni
N-P-55U-CF
5.4 44.6
5.4 44.6
5.4 44.6
5.4 44.6
5.4 44.6
Ag
Ni
Ag
Ag
Ag
Ag
Au
1
1
1
1
1
N-P-55U-Ni-CF
N-P-58U-CF
Ag
Ni
N-P-58U-Ni-1-CF
N-P-58U-NiCAu-CF
Ni
Finish
Center
Conductor Conductor
Applicable
Cable
Assmbly
Instruction
Part Number
φA (L)
Outer
3.5D-FE
3.5D-QEFA
5C-2V
N-SP-3.5DFE-CF
N-P-5-CF
6.2 41.5
8.6 44.0
8.6 44.0
9.1 45.0
9.1 45.0
9.1 45.0
Ni
Ag
Ni
Au
Ag
Ag
Ag
Ag
Au
ー
1
1
1
1
1
(L)
5D-2V
5C-2V
N-P-5-Ni-CF
5D-2V
5C-2W
5D-2W
5C-2W
5D-2W
5C-2W
5D-2W
5D-FB
N-P-5W-CF
Ag
Ni
N-P-5W-Ni-CF
N-P-5W-NiCAu-CF
Ni
N-P-5DFB-1-CF
N-SP-5DSFA-CF
8.1 44.0
8.6 41.5
Ni
Ni
Ag
Au
1
5D-SFA
RG-8/U
RG-9/U
RG-8/U
RG-9/U
RG-8/U
RG-9/U
ー
N-P-8U-CF
11.2 44.0
11.2 44.0
11.25 38.0
Ag
Ni
Ag
Ag
Ag
1
1
2
N-P-8U-Ni-CF
UG-21D/U-CF
Ag
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
2
Unit:mm
NꢀSeries
○ Straight Plug
Clamp Type
Finish
Outer
Applicable
Cable
Assembly
Part Number
N-P-8-1-CF
φA
Center
Instruction
Conductor Conductor
8D-2V
8D-2V
8D-FB
12.6
12.6
11.8
Ag
Ag
Ag
Ag
4
4
N-P-8-1-Ni-CF
Ni
(38.0)
N-P-8DFB-1-CF
Ni
ー
Finish
Applicable
Cable
Assembly
Part Number
N-P-10-CF
φA
Outer
Center
Instruction
Conductor Conductor
10C-2V
10D-2V
10C-2V
10D2V
10D-FB
14.2
Ag
Ag
4
N-P-Ni-CF
14.2
14.2
Ni
Ni
Ag
Ag
4
4
(51.7)
N-P-10DFB-1-CF
Crimp Type
Finish
Applicable
Cable
Assembly Crimp
Part Number
φA (L)
Outer
Center
Instruction
Tool
ConductorConductor
3D-2V
3D-LFV
5D-2V
N-P-3D2V-CR20-CF
N-P-5D2V-CR20-CF
7.1 35.0
9.5 37.2
Ni
Ni
Ag
Ag
6
7
CR-H-1152
CR-H-1130
(L)
Above drawing is N-P-5D2V-CR20-CF.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
3
Unit:mm
NꢀSeries
○ Right Angle Cable Plug
Clamp Type
φ21
Finish
Center
ConductorConductor
Applicable
Cable
Assembly
Part Number
φA (L1)(L2)
Outer
Instruction
N-LP-58U-CF
RG-58/U
RG-58/U
5.4 52.9 36.6
5.4 52.9 36.6
Ag
Ag
ー
ー
N-LP-58U-Ni-CF
Ni
Ag
(L1)
Finish
Center
ConductorConductor
φ21
Applicable
Cable
Assembly
Part Number
φA(L1)(L2)
Outer
Instruction
N-LP-5-CF
5D-2V
5D-2V
8.6 53.0 36.6
8.6 53.0 36.6
Ag
Ag
ー
ー
N-LP-5-Ni-CF
Ni
Ag
(L1)
Finish
Applicable
Cable
Assembly
Instruction
φ21
Part Number
Outer
Center
Conductor Conductor
RG-8U
RG-9/U
RG-8U
RG-9/U
N-LP-8U-CF
Ag
Ag
ー
ー
N-LP-8U-Ni-CF
Ni
Ag
(47.0)
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
4
Unit:mm
NꢀSeries
○Straight Cable Jack
Clamp Type
Finish
Applicable
Cable
Assembly
Instruction
Part Number
φA
Outer
Center
Conductor Conductor
3C-2V
3D-2V
N-J-3-CF
6.2
6.2
Ag
Ag
2
2
(46)
3C-2V
N-J-3-Ni-CF
Ni
Ag
3D-2V
N-J-58U-CF
RG-58/U
RG-58/U
5.4
5.4
Ag
Ni
Ag
Ag
2
2
N-J-58U-Ni-CF
Finish
Applicable
Cable
Assembly
Part Number
φA (L)
Outer
Center
Instruction
Conductor Conductor
N-J-5-CF
5D-2V
5D-2V
8.6
8.6
47.0
47.0
Ag
Ag
2
2
(L)
N-J-5-Ni-CF
Ni
Ag
RG-8/U
RG-9/U
RG-8/U
RG-9/U
N-J-8U-CF
11.2 47.0
11.2 47.0
Ag
Ni
Ag
Ag
2
2
N-J-8U-Ni-CF
Finish
Applicable
Cable
Assembly
Part Number
φA φB (L)
Outer
Center
Instruction
Conductor Conductor
N-J-8-1-CF
8D-2V
8D-2V
12.7 19.1 41.2
12.7 19.1 41.2
Ag
Ag
5
5
N-J-8-1-Ni-CF
Ni
Ag
(L)
RG-8/U
RG-9/U
UG-23D/U-CF
11.2 19.0 40.0
Ag
Ag
5
Finish
Applicable
Cable
Assembly
Part Number
N-J-10-CF
φA φB
14.2 22.2
Outer
Center
Instruction
Conductor Conductor
10C-2V
10D-2V
10C-2V
10D-2V
10D-FB
Ag
Ag
5
(52.7)
N-J-10-Ni-CF
14.2 22.2
14.2 22.2
Ni
Ni
Ag
Ag
5
5
N-J-10DFB-1-CF
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
5
Unit:mm
NꢀSeries
○ Straight Panel Cable Jack
4-φ3.2
Finish
2.0
B
Applicable
Cable
Assembly
Instruction
Part Number
φA
B
C
Outer
Center
Conductor Conductor
3C-2V
3D-2V
N-PJ-3-CF
6.2
6.2
16.7 18.2
16.7 18.2
Ag
Ag
3
3C-2V
C
N-PJ-3-Ni-CF
Ni
Ag
3
(46)
□25.4
3D-2V
N-PJ-55U-CF
RG-55/U
RG-55/U
RG-58/U
RG-58/U
5.4
5.4
5.4
5.4
16.6 18.2
16.6 18.2
16.6 18.2
16.6 18.2
Ag
Ni
Ag
Ag
Ag
Ag
3
3
3
3
+0.1
0
N-PJ-55U-Ni-CF
N-PJ-58U-CF
4-φ3.2
Ag
Ni
N-PJ-58U-Ni-CF
+0.1
0
φ17.8
±0.05
18.2
Panel Mounting Dimensions
Finish
Applicable
Cable
Assembly
Instruction
4-φ3.2
2.0
C
Part Number
φA
B
C
D
Outer
Center
Conductor Conductor
5C-2V
5D-2V
5D-2V
N-PJ-5-CF
8.6
8.6
17.5 16.7 18.24
17.5 16.7 18.24
Ag
Ni
Ag
Ag
3
3
N-PJ-5-Ni-CF
D
(47)
□25.4
+0.1
0
4-φ3.2
+0.1
0
φ18.0
±0.05
18.24
Panel Mounting Dimensions
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
6
Unit:mm
NꢀSeries
○Receptacle Jack
4-φA
Finish
Part Number
N-R-CF
L
φ A
Outer
Center
Conductor Conductor
29
29
29
29
Ag
Ag
Ag
Au
Ag
φ 3.2
φ 3.2
φ 3.2
φ 3.2
N-R-Ni-CF
Ni
N-R-NiCAu-CF
UG-58A/U-CF
Ni
2
18.2
Ag
18.7
□25.4
L
+0.1
0
4-φ3.2
+0.1
0
φ15.0
±0.05
18.2
Panel Mounting Dimensions
○Dust Cap
5/8-24UNEF-2B
(φ3.5)
Part Number
Finish
Ni
N-RC-5
N-RC-5-D1
Ag
(60)
(71)
5/8-24UNEF-2B
Part Number
N-RC-3-CF
Finish
Ni
11.1
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
7
Unit:mm
NꢀSeries
○Assembly Instruction(1) Straight Cable Plug
Parts Configulration
Contact
Insulator
Ring
Nut
Washer
Gasket
Clamp
Body
The Cable length require for the single-ended
cable assembly.
① L=
①
②
L=L1-10
L1
Outer
Sheath
Conductor
Insert the nut, washer and gasket into the cable.
ꢀ Cut the sheath 15mm from the end of the cable
and insert the clamp.
②
Please be careful to not damage the outer
conductor.
15mm
Gasket
Washer
Clamp
Nut
Pick the outer conductor and turn
down to the clamp equally.
Pick the outer conductor and turn down to the
clamp. Cut the outer conductor along the clamp.
Cut the insulator and center conductor as fig.3.
Please be careful to not damage the center
conductor.
③
④
Insulator
Canter Conductor
(Pre-soldering)
③
④
5.0mm
3.5~4.0mm
3.5mm
Solder up the contact with the center conductor.
Please be careful to not deform the
insulator by heat.
When the solder is stick out, please shave
the extra solder.
No gap between contact and insulator of
the cable.
Soldering
Contact
No gap
Insert the ring and insulator as fig. 5.
⑤
⑥
⑤
⑥
Ring
Insulator
Insert the above assembly into the body and screw
up by wrench.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
8
Unit:mm
NꢀSeries
○Assembly Instruction(2) Straight Cable Jack
Parts Configulration
Washer
Body
Washer
Clamp
Insulator
Contact
Gasket
Nut
The Cable length require for the single-ended
cable assembly.
① L=
①
②
L=L1-12
L
1
Nut
Gasket
Outer
Conductor
Insert the nut, washer and gasket into the cable.
②
ꢀCut the sheath 15mm from the end of the cable
and insert the calmp.
Please be careful to not damage the outer conductor .
Cable
15mm
Washer
Center Conductor
(Pre-soldering)
Insulator
Pick the outer conductor and turn down to the
clamp. Cut the outer conductor along the clamp.
Cut the insulator and center conductor as fig.3.
Please be careful to not damage the center
conductor.
③
④
③
④
Clamp
3.5~4mm
3.5mm
mm
5
Contact
Soldering
Solder up the contact with the center conductor.
Please be careful to not deform the
insulator by heat.
When the solder is stick out, please shave the
extra solder.
No gap between contact and insulator of
the cable.
No gap
Washer
Inser the washer and insulator as fig.5.
⑤
⑥
⑤
⑥
Insulator
Insert the above assembly into the body and screw
up by wrench.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
9
Unit:mm
NꢀSeries
○Assmbly Instruction(3)Straight Panel Jack
Parts Configulration
Washer
Body
Washer
Clamp
Insulator
Contact
Gasket
Nut
The Cable length require for the single-ended
① L=
cable assembly.
①
②
1
L=L -6.7
L
1
ꢀꢀ L=-L -1.2
2
L
2
Nut
Gasket
Outer
Conductor
Insert the nut, washer and gasket into the cable.
②
ꢀ Cut the sheath 15mm from the end of the cable
and insert the clamp.
Please be careful to not damage the outer
conductor.
mm
15
Cable
Washer
Insulator Center Conductor
(Pre-soldering)
Pick the outer conductor and turn down to the
clamp. Cut the outer conductor along the clamp.
Cut the insulator and center conductor as fig.3.
Please be careful to not damage the center
conductor.
③
③
④
Clamp
3.5~4mm
3.5mm
5mm
Contact
Soldering
Solder up the contact with the center conductor.
④
ꢀ Please be careful to not deform the insulator
by heat.
When the solder is stick out, please shave the extra
solder.
No gap
No gap between contact and insulator of the cable.
Washer
Insert the washer and insulator as fig. 5.
⑤
⑥
⑤
⑥
Insulator
Insert the above assembly into the body and screw
up by wrench.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
10
Unit:mm
NꢀSeries
○Assembly Instruction(4)MIL Clamp Straigh Cable Plug
Parts Configulration
Nut
Gasket
※Washer
Clamp
Body
Contact
※ As for N-P-8-1-CF, N-P-8-1-Ni-CF and UG-21D/U-CF,
washer is not attached. The washer is not inserted into the cable.
The cable length require for the single-ended
cable assembly as following table.
①
①
Part Number
ꢀN-P-8-1-CF
ꢀN-P-8-1-Ni-CF
ꢀUG-21D/U-CF
ꢀN-P-10-CF
L(mm)
L
1
ꢀꢀꢀL ー11.4
1
ꢀN-P-10-Ni-CF
ꢀN-P-10DFB-1-CF
ꢀꢀꢀL ー21.5
1
Outer
Washer
Sheath
Conductor
②
③
Insert the nut, washer and gasket into the cable.
②
ꢀ Cut the sheath 10mm from the end of the cable
and insert the clamp.
Please be careful to not damage the outer
conductor.
10mm
Clamp
Gasket
Nut
Pick the outer conductor and turn down to the
clamp. Cut the outer conductor along the clamp.
Cut the insulator and center conductor as fig.3.
Please be careful to not damage the center
conductor.
③
Tip the outer conductor and
turn down to the clamp equally.
Insulator
Center Conductor
(Pre-soldering)
Part Number
A(mm)
B(mm)
N-P-8-1-CF
N-P-8-1-Ni-CF
UG-21D/U-CF
1.0
3.5 ~ 4.0
B
5.0mm
A
N-P-10-CF
N-P-10-Ni-CF
N-P-10DFB-1-CF
1.8
4.0 ~ 4.5
Soldering
Contact
④
⑤
Solder up the contact with the center conductor.
④
⑤
Please be careful to not deform the insulator
by heat.
No gap
When the solder is stick out, please shave
the extra solder.
No gap between contact and insulator of
the cable.
Insert the above assembly into the body and screw
up by wrench.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
11
Unit:mm
NꢀSeries
○Assembly Instruction(5)MIL Clamp Straight Cable Jack
Parts Configulration
Nut
Gasket
Calmp
Contact
Body
※Washer
※ As for N-J-8-1-CF, N-J-8-1-Ni-CF and UG-23D/U-CF,
the washer is not attached. The washer is not inserted into the cable.
The cable length require for the single-ended
cable assembly as following table.
①
①
②
Part Number
ꢀN-J-8-1-CF
ꢀN-J-8-1-Ni-CF
ꢀUG-23D/U-CF
ꢀN-J-10-CF
L(mm)
ꢀꢀꢀL ー13.2
L
1
1
L ー13.8
1
Washer
Sheath
Outer conductor
Clamp
ꢀN-J-10-Ni-CF
ꢀN-J-10DFB-1-CF
ꢀꢀꢀL ー23.4
1
Insert the nut, washer and gasket into the cable.
ꢀ Cut the sheath 10mm from the end of the cable
and insert the clamp.
②
10mm
Nut
Gasket
Please be careful to not damage the outer
conductor.
Pick the outer conductor and
turn down to the clamp equally/ Insulator
Pick the outer conductor and turn down to the
clamp. Cut the outer conductor along the clamp.
Cut the insulator and center conductor as fig.3.
Please be careful to not damage the center
conductor.
③
③
④
Outer Conductor
(Pre-soldering)
mm
5
Part Number
A(mm)
B(mm)
A
B
N-J-8-1-CF
N-J-8-1-Ni-CF
UG-23D/U-CF
1.0
3.5 ~ 4.0
Soldering
Contact
N-J-10-CF
N-J-10-Ni-CF
N-J-10DFB-1-CF
1.8
4.0 ~ 4.5
No gap
Solder up the contact with the center conductor.
Please be careful to not deform the insulator
by heat.
④
⑤
When the solder is stick out, please shave
the extra solder.
No gap between contact and insulator of
the cable.
⑤
Insert the above assembly into the body and screw
up by wrench.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
12
Unit:mm
NꢀSeries
○Assembly Instruction(6) Crimp Straight Cable Plug
Parts Configulration
Gasket
Ferule
Boot
Body
Sleeve
Contact
Insulator
Coupling Ring
①
②
The cable length require for the single-ended cable
①
②
assembly.
L+17mm
L
as
Insert the boot into the cable. Cut the cable
fig.2. Please be careful to not damage the outer
conductor.
Sheath
Boot
Outer conductor
12.4mm
Cable
Inserting the ferule, tip the outer
③ After
③
④
Ferule
conductor and spread the top of the outer
conductor. Insert the sleeve between outer
conductor and the insulator.
Insulator
Sleeve
Cut the insulator along the sleeve.
④
ꢀ And cut the outer conductor along the sleeve.
Outer Conductor
Sleeve
Put the contact into the center hole of the crimp tool and
insert the cable assembly and crimp the contact as
fig.5.ꢀꢀ
⑤
⑤
Center hole
ꢀ ● Crimp Tool : CR-H-1152
Tool
Insulator
Center conductor
(3mm)
Contact
Tool
Insert the above cable assembly into the body and crimp
as fig.6. Body end is leveled to the tool end.
⑥
⑥
⑦
● Crimp Tool : CR-H-1152
Tool end
Body end
Body
Tool
Screw up the cable assembly into the body until the
reverse thread is end and reached hollow .
After the coupling ring is screwed, fit the gasket into
the screw clearance. Cover the boot on the root of the
connector.
⑦
Screw
clearance
Reverse thread
Gasket
Coupling ring
Boot
Hollow
Interface
ꢀ
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
13
Unit:mm
NꢀSeries
○ Assembly Instruction(7) Crimp Straight Cable Plug
Parts Configulration
Contact
Sleeve
Ferule
Boot
Gasket
Body
Coupling Ring
The cable length require for the single-ended cable
①
①
assembly.
L+22mm
L
as
Insert the boot into the cable. Cut the cable
fig.2. Please be careful to not damage the outer
conductor.
②
③
②
③
15mm
Outer Conductor
Sheath
Boot
Cable
After Inserting the ferule, tip the outer
Ferule
conductor and spread the top of the outer
conductor. Insert the sleeve between outer
conductor and the insulator. Plunge the sleeve
by stripper without diging the edge.
Sleeve
ꢀ
Insulator
● Stripper Part No. : 357J-15485
Pull out the edge
Stripper
Push this side
Cut the insulator by stripper as fig.4.
④
④
Insert the stripper and dig the edge to the
insulator. Rotate the stripper a few times and pull
ꢀ off the insulator.
ꢀ And cut the outer conductor along the sleeve.
Cut off the round
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
14
Unit:mm
NꢀSeries
○Assembly Instruction(7) Crimp Straight Cable Plug
Put the contact into the center hole of the crimp tool and
⑤
ꢀ
insert the cable assembly and crimp the contact as
fig.5.ꢀꢀ
⑤
Center hole
Tool
● Crimp Tool : CR-H-13970
Center Conductor
3.0mm
5.6mm
Contact
Tool
Insert the above cable assembly into the body and crimp
as fig.6. Body end is leveled to the tool end.
⑥
Tool end
⑥
⑦
Body
Body end
Tool
Screw
clearance
Screw up the cable assembly into the body until the
reverse thread is end and reached hollow .
After the coupling ring is screwed, fit the gasket into
the screw clearance. Cover the boot on the root of the
connector.
⑦
ꢀ
Gasket
Coupling Ring
Reverse thread
Boot
Interface
Hollow
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
ꢀMoreover, the characteristic and the specification of the published product are the reference values.
ꢀPlease confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp