TNC-J-2.5D2W-CR10-CF [DDK]

TNC Style Connector;
TNC-J-2.5D2W-CR10-CF
型号: TNC-J-2.5D2W-CR10-CF
厂家: DDK LTD.    DDK LTD.
描述:

TNC Style Connector

文件: 总15页 (文件大小:447K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TNC Style Connector  
TNC Series  
FEATURE  
・TNC series is a thread coupling coaxial  
connector which is modified BNC style  
connector.  
Characteristic  
Impedance  
50 Ω  
・Due to the thread coupling, it is superior to  
BNC style connector in vibration load.  
・Other electrical and mechanical characteristics  
are same as BNC style connector.  
・Recommended toque of coupling is  
45 〜 68.6N・cm.  
Frequency  
Range  
DC to 2GHz  
Lock Type  
Screw  
CONFORMING STANDARD  
MIL-PRF-39012  
SPECIFICATIONS  
Characteristic Impedance  
Rated Voltage  
50 Ω  
500VAC(r.m.s.)  
Dielectric Withstanding Voltage 500V AC(r.m.s) / 1 minute  
Insulation Resistance  
Contact Resistance  
V.S.W.R.  
1,000M Ω min. at 500V DC  
3m Ω max.  
1.3 max. (DC 〜 2GHz)  
-55 〜 +85℃  
Operating Temperature  
* The specifications are typical but may not apply to all  
connectors. Please check the specifications on each item with  
its drawing from us when you use.  
RRooHHSS  
MATERIAL/FINISH  
CCoommpplliiaanntt  
Item  
Shell  
Contact (Female)  
Contact (Male)  
Insulator  
Material / Finish  
Copper Alloy / Ni or Ag Plating  
Copper Alloy / Ag or Au Plating  
Copper Alloy /Ag or Au Plating  
PTFE  
Gasket  
Silicon Rubber  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
150424  
http://www.ddknet.co.jp  
TNCꢀSeries  
Unit:mm  
Straight Cable Plug  
Clamp Type  
Finish  
Center  
ConductorConductor  
Assembly  
Part Number  
Applicable Cable  
Outer  
L
Instruction  
3D-2V  
TNC-P-3-CF  
25.0  
Ag Ag  
6
3D-QEV  
L
Crimp Type  
Finish  
Center  
ConductorConductor  
Assembly  
Crimp  
Tool  
Part Number  
Applicable Cable  
φA  
Outer  
L
Instruction  
1.5D-2W  
1.5D-QEW  
2.5D-2W  
TNC-P-1.5DQEW-CF  
TNC-P-2.5D2W-CR10-CF  
TNC-P-3D2W-CR10-CF  
5.5 22.3  
6.3 24.3  
7.9 24.3  
Ni  
Ni  
Ni  
Au  
Ag  
Ag  
1
2
2
CR-H-1100  
CR-H-1115  
CR-H-1135  
L
2.5D-QEW  
3D-2W  
3D-QEW  
Finish  
Center  
ConductorConductor  
Ni Au  
Assembly  
Outer  
Part Number  
Applicable Cable  
2D-FB  
Crimp Tool  
φA  
L
Instruction  
TNC-P-2DFB-1-CF  
6.2 29.7  
3
CR-H-1105  
L
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
2
TNCꢀSeries  
Unit:mm  
Straight Cable Jack  
Crimp Type  
Finish  
Center  
Conductor Conductor  
Applicable  
Cable  
Assembly  
Outer  
Part Number  
Crimp Tool  
φA φB  
L
Instruction  
TNC-J-1.5DXW-CR10-120-CF  
TNC-J-2.5D2W-CR10-CF  
2D-FB  
5.5 12.0 26.8  
Ni  
Ag  
4
CR-H-1142  
CR-H-1105  
2.5D-2W  
2.5D-QEW  
6.25 14.6 25.0  
Ni  
Ag  
4
L
Finish  
Center  
Conductor Conductor  
Assembly  
Applicable  
Cable  
Outer  
Part Number  
Crimp Tool  
CR-H-1135  
φA φB  
L
Instruction  
3D-2W  
TNC-J-3D2W-CR10-CF  
7.9 14.6 25.42  
Ni Ag  
4
3D-QEW  
5.0  
17.0  
L
○ Straight Bulkhead Cable Jack  
Finish  
Center  
Conductor Conductor  
Applicable  
Cable  
Assembly  
Outer  
Part Number  
Crimp Tool  
φA φB  
L
Instruction  
2.5D-2W  
TNC-BJ-2.5D-QEW-CF  
14.0 6.25 27.9  
Ni Ag  
4
CR-H-1105  
2.5D-QEW  
※ Mounting Panel Thickness:2.7mm max.  
+0.1  
13  
φ11.2 0ꢀ  
(Flat Diameter)  
10.4+0.1  
0
2
16.8  
10.2  
(Detent Diameter)  
L
Panel Mounting Dimensions  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
3
TNCꢀSeries  
Unit:mm  
Straight Panel Cable Jack  
Finish  
Center  
Conductor Conductor  
Applicable  
Cable  
Assembly  
Crimp Type  
Outer  
Part Number  
Crimp Tool  
Instruction  
1.5D-QEW  
1.5D-2W  
TNC-PJ-1.5DQEW-CR10-CF  
Ni  
Ag  
5
CR-H-1142  
4-φ3.0  
4-φ3.0  
φ12.0  
15.8  
26.8  
2.3  
12.7  
□17.5  
12.7  
Panel Mounting Dimensions  
Finish  
Applicable  
Cable  
Assembly  
Outer  
Center  
Part Number  
Crimp Tool  
Instruction  
Conductor Conductor  
1.5D-XW  
TNC-PJ-1.5DXW-CR10-M-CF  
Ni Ag  
7
CR-H-1100  
1.5D-XWTA  
+0.1  
0
4-φ3.0  
4-M2.5×0.45  
+0.1  
φ12.0 0  
15.8  
30.8  
2.3  
18.2  
18.2±0.05  
□25.4  
Panel Mounting Dimensions  
Finish  
Applicable  
Cable  
Assembly  
Outer  
Center  
Part Number  
Crimp Tool  
Instruction  
Conductor Conductor  
1.5D-QEV  
1.5D-2V  
TNC-PJ-2H-1.5D-CR10-CF  
Ni  
Ag  
5
CR-H-1101  
2-φ3.2  
2-φ3.2  
φ6.0  
2.3  
14.7  
24.4  
12  
Panel Mounting Dimensions  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
4
TNCꢀSeries  
Unit:mm  
○ Receptacle Jack  
Finish  
Outer  
Center  
Part Number  
TNC-R-CF  
Conductor  
Conductor  
Ag  
Au  
TNC-R-NiCAu-CF  
Ni  
Au  
4-φ2.8±0.15  
4-M2.6×0.45  
φ11.1+0.2  
0
2.3  
15.8  
26.3  
12.7  
12.7±0.05  
□17.5  
Panel Mounting Dimensions  
Finish  
Outer  
Center  
Part Number  
TNC-R2-CF  
Conductor  
Conductor  
Ag  
Ag  
TNC-R2-Ni-CF  
Ni  
Ni  
Ag  
Au  
TNC-R2-NiCAu-CF  
+0.1  
4-φ3.0  
4-φ3.00  
φ11.1+0.2  
0
2.3  
15.8  
26.3  
12.7  
□17.5  
12.7±0.05  
Panel Mounting Dimensions  
Finish  
Outer  
Center  
Part Number  
TNC-R2-2H-Ni-CF  
Conductor  
Conductor  
Ni  
Ag  
2-φ3.0  
+0.1  
φ9.00  
2.3  
15.8  
2-φ3+00.1  
11  
26.3  
Panel Mounting Dimensions  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
5
TNCꢀSeries  
Unit:mm  
Receptacle Jack  
Finish  
Outer  
Center  
Part Number  
TNC-SR-3-CF  
Conductor  
Conductor  
Ni  
Au  
+0.1  
4-φ3.00  
4-φ3.0  
φ12+0.1  
0
4
2.3  
9.6  
15.8  
12.7  
□17.5  
12.7±0.05  
27.7  
Panel Mounting Dimensions  
Finish  
Outer  
Center  
Part Number  
TNC-SR-6-CF  
Conductor  
Conductor  
Ni  
Au  
+0.1  
4-φ3.10  
4-φ3.0  
(Thru-Hole)  
+0.1  
0
φ4.1  
2
6.8  
2
17.8  
12.7±0.05  
12.7  
26.6  
□17.5  
Panel Mounting Dimensions  
Finish  
Outer  
Center  
Part Number  
TNC-SR-9-CF  
Conductor  
Conductor  
Ni  
Au  
4-φ3.0  
+0.1  
4-φ3.10  
(Thru-Hole)  
+0.1  
0
φ4.1  
12.7  
2
□17.5  
8.5  
2
17.8  
12.7±0.05  
26.6  
Panel Mounting Dimensions  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
6
TNCꢀSeries  
Unit:mm  
Receptacle Plug  
Finish  
Outer  
Center  
Part Number  
Conductor  
Conductor  
TNC-PR-CF  
4-φ3.0  
Ag  
Ag  
+0.1  
4-φ3.20  
+0.1  
φ9.00  
18.0  
28.5  
2.3  
12.7  
□17.5  
12.7±0.05  
Panel Mounting Dimensions  
Right Angle Receptacle Jack  
Finish  
Outer  
Center  
Part Number  
Conductor  
Conductor  
TNC-LR-CF  
TNC-LR-Ni-CF  
Ag  
Au  
Ni  
Ag  
4-φ3+0.1  
23  
0
12.7  
14.3  
2.3  
+0.1  
φ9.00  
4-φ3.0  
12.7±0.05  
Panel Mounting Dimensions  
Finish  
Outer  
Center  
Part Number  
TNC-LR-1-CF  
Conductor  
Conductor  
Ag  
Ag  
21.6  
4-M2.6  
5
14.3  
2.3  
12.7  
□17.5  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
7
TNCꢀSeries  
Unit:mm  
○ Dust Cap  
7/16-28UNEF-2B  
Part Number  
TNC-RC-1  
TNC-RC-1-D1  
Finish  
(φ3.5)  
Ni  
Ag  
(60)  
(75)  
7/16-28UNEF-2B  
Part Number  
Finish  
Ni  
TNC-C-2-CF  
TNC-C-2-D1-CF  
Ag  
15  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
8
TNCꢀSeries  
Unit:mm  
○ Assembly Instruction(1)  
Parts Configulration  
Sleeve  
Contact  
Heat-shrinkable tube  
Ferule  
Insulator  
Body  
Cable length which require for the cable assembly.  
Cable length  
L=L1-3.3  
L
L=L2+19.7  
L2  
L1  
① Insert the heat-shrinkable tube onto the cable.  
Cut the cable as fig.1.  
Heat-shrinkable tube  
Outer Conductor  
Please be careful to not damage the outer conductor.  
±0.5  
14.7  
Sheath  
② Insert the ferule on the outer conductor and  
spread the top of the outer conductor.  
Insulator  
Sleeve  
Insert the sleeve between insulator and outer  
conductor. And cut the outer conductor along the sleeve.  
Ferule  
Cut the insulator as fig. 3.  
Insulator  
ꢀꢀPlease be careful to not damage the center conductor.  
ꢀꢀPre-solder the center conductor and cut the center  
ꢀꢀconductor.  
Outer Conductor  
Center Conductor  
(Pre-soldering)  
ꢀPlease be careful to not damage the insulator by  
ꢀsoldering. Insert the insulator as fig.3.  
0
6.2-0.5  
4+-00.3.2  
Insulator  
Soldering  
④ Solder up the contact with center conductor.  
No gap between insulator and contact.  
No gap  
Contact  
⑤ Insert the body into the above cable assembly.  
And crimp the root of the body.  
Please be careful to meet the crimp height  
as follows.  
5.33~5.84  
(between body and contact)  
A
Measuring point  
(3.1)  
Dies A  
NoteDistance between body and contact must be met.  
Cover the heat-shrinkable tube on the root of the body  
and heat up.  
Heat-shrinkable tube  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
9
TNCꢀSeries  
Unit:mm  
○ Assembly Instruction(2)  
Parts Configulration  
Boot  
Contact  
Ferule  
Sleeve  
Body  
① Insert the boot into the cable and  
cut the cable as fig.1.  
14  
Boot  
Cable  
ꢀPlease be careful to not damage the outer conductor.  
Outer Con  
Sheath  
Ferule  
② Insert the ferule on the outer conductor and  
spread the top of the outer conductor. Press-in rhe  
sleeve between insulator and outer conductor.  
ꢀ Cut the extra outer conductor along the sleeve.  
Sleeve  
Outer Conductor  
Center Conductor  
③ Cut the insulator and center conductor as fig.3.  
Part Number  
TNC-P-2.5D2W-CR10-CF  
TNC-P-3D2W-CR10-CF  
A
B
A
B
5.0mm  
5.5mm  
4.0mm  
3.5mm  
Crimp Tool  
④ Pinch the contact in the crimping hole(center  
and insert the center conductor of the cable.  
hole)  
Crimp the contact (match the side hole of contact  
with the curve of crimping hole of tool.)  
Insulator  
Center Conductor  
Contact  
Part Number  
TNC-P-2.5D2W-CR10-CF  
TNC-P-3D2W-CR10-CF  
Crimp Tool  
CR-H-1115  
CR-H-1135  
No gap  
Crimping Dies  
Contact crimped  
⑤ Insert the above contact into the body.ꢀMatch the  
ꢀ key in the insulator and keyway of the contact.  
Crimp the root of body as fig.5. Cover the boot on the  
root of the connector body.  
Tool Surface  
Body Surface  
Crimp Tool  
Body  
Boot  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
10  
TNCꢀSeries  
Unit:mm  
Assembly Instruction(3)  
Parts Configulration  
Sleeve  
Boot  
Contact assembly  
Body  
① Insert the boot and sleeve into the cable and  
cut the cable as fig.1. Please be careful to not  
damage the outer conductor.  
Boot  
Sleeve  
19  
Outer Conductor  
Sheath  
Cable  
10  
4
7
4
② Cut the cable as fig.2. Cut the center conductor  
after pre-soldering.  
Insulator  
Outer Conductor  
Aluminum foil tape  
Cente Conductor  
(Cut off afterpre-soldering)  
③ Insert the contact between outer conductor and  
aluminum foil tape. Solder the contact with  
center conductor.  
Soldering  
When the solder is stick out, please shave  
the extra solder along the contact.  
Contact assembly  
1
④ Cover the sleeve on the outer conductor and  
Crimp Tool : (CR-H-1105)  
crimp as fig.4.  
Sleeve  
Boot  
⑤ Insert the above contact into the body and  
screw. Cover the boot on the root of the body.  
Body  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
11  
TNCꢀSeries  
Unit:mm  
○ Assembly Instruction(4)  
Parts Configulration  
Contact  
Body  
Heat-shrinkable tube  
Ferule  
Insulator  
Sleeve  
① Insert the heat-shrinkable tube into the cable  
and cut the cable as fig.1. Please be careful to  
not damage the outer conductor.  
Heat-shrinkable tube  
Sheath  
Outer Conductor  
A
Part Number  
TNC-J-1.5DXW-CR10-120-CF  
TNC-J-2.5D2W-CR10-CF  
TNC-J-3D2W-CR10-CF  
TNC-BJ-2.5DQEW-CF  
A
13.0mm  
11.0mm  
11.5mm  
13.0mm  
Cable  
Outer Conductor  
Ferule  
Sleeve  
② Insert the ferule on the outer conductor and  
spread the top of the outer conductor. Press in  
the sleeve between outer conductor and  
insulator.  
Spread the top  
Cut off the extra outer conductor along the sleeve.  
Cut the cable as fig.3. Cut the center conductor  
after pre-soldering. Please be careful to not damage  
the center conductor.  
Sleeve  
Insulator  
Center Conductor  
(Pre-soldering)  
Part Number  
B
C
Outer Conductor  
C
B
TNC-J-1.5DXW-CR10-120-CF  
TNC-J-2.5D2W-CR10-CF  
TNC-J-3D2W-CR10-CF  
TNC-BJ-2.5DQEW-CF  
5.7mm  
3.0mm  
3.1mm  
6.0mm  
2.8mm  
2.5mm  
2.5mm  
2.0mm  
Soldering  
Contact  
Insulator  
Insert the insulator and solder the contact with center  
conductor.  
When the solder is stick out, please  
No gap  
shave the extra solder along the contact.  
⑤ Insert the above contact into the body. Match the  
ꢀ key in the insulator and keyway of the contact.  
Crimp the root of body as fig.5.  
Crimping Dies  
same level  
Part Number  
TNC-J-1.5DXW-CR10-120-CF  
TNC-J-2.5D2W-CR10-CF  
TNC-J-3D2W-CR10-CF  
TNC-BJ-2.5DQEW-CF  
Tool  
CR-H-1100  
CR-H-1105  
CR-H-1135  
CR-H-1105  
at-shrinkable tube  
⑥ Cover the heat-shrinkable tube on the root of  
the body and heat up.  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
12  
TNCꢀSeries  
Unit:mm  
○ Assembly Instruction(5)  
Parts Configulration  
Heat-shrinkable tube  
Ferule  
Contact  
Body  
Insulator  
Sleeve  
① Cut the cable as fig.1.  
Please be careful to not damage the outer  
conductor.  
Sheath  
Outer Conductor  
Part Number  
A
A
TNC-PJ-1.5DQEW-CR10-CF  
TNC-PJ-2H-1.5D-CR10-CF  
13.0mm  
10.0mm  
Ferule  
Insulator  
Spread the top  
② Insert the ferule on the outer conductor and spread  
the top of the outer conductor.  
③ Insert the sleeve and cut the cable as fig.3.  
ꢀPress in the sleeve between outer conductor and  
insulator. Cut off the extra outer conductor along the  
sleeve. Cut the insulator and center conductor as below  
table. Cut the center conductor after pre-soldering.  
Please be careful to not damage the center conductor.  
Sleeve  
Center Conductor  
(Pre-soldering)  
C
B
Cut the center conductor after pre-soldering  
Part Number  
B
C
TNC-PJ-1.5DQEW-CR10-CF  
TNC-PJ-2H-1.5D-CR10-CF  
5.7mm  
4.0mm  
3.0mm  
3.0mm  
④ Insert the insulator on the insulator of the cable  
and solder the contact with center conductor.  
When the solder is stick out, please  
Soldering  
Insulator  
Contact  
shave the extra solder along the contact.  
No gap  
⑤ Insert the above contact into the body. Match the  
ꢀ key in the insulator and keyway of the contact.  
Crimp the root of body as fig.5.  
Body  
same level  
Part Number  
TNC-PJ-1.5DQEW-CR10-CF  
TNC-PJ-2H-1.5D-CR10-CF  
Tool  
CR-H1142  
CR-H1101  
Crimping Dies  
⑥ Cover the heat-shrinkable tube on the root of  
the body and heat up.  
Heat-shrinkable tube  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
13  
TNCꢀSeries  
Unit:mm  
○ Assembly Instruction(6)  
Parts Configulration  
Washer  
Contact  
Nut  
Gasket  
Clamp  
Body  
3D-2V  
① The cable length require for the cable assembly  
L1=L-x  
L1  
L
② Insert nut, washer and gasket into the cable and  
cut the cable as fig.2.  
Sheath  
Outer Conductor  
Please be careful to not damage the outer conductor.  
10  
Nut  
Washer  
Gasket  
③ Insert the clamp on the outer conductor and turn  
down the outer conductor. Cut the outer  
conductor along the clamp.  
Pick the outer conductor  
and turn down to the clamp  
Insulator  
ꢀCenter Conductor  
(Pre-soldering)  
Clamp  
Cut the insulator as fig.3. Please be careful to not  
damage the center conductor.  
Cut the center conductor after pre-soldering.  
Trim the outer conductor  
along the clamp  
0
3+0.5  
-0.5  
3
0
④ Insert the contact and solder the contact with  
center conductor.  
Contact  
Soldering  
Please bee careful to not damage the insulator by  
heat.  
No gap  
Body  
Insulator  
Body assembly  
⑤ Insert the above contact into the body.  
Insert the the gasket and washer into the body and  
screw the nut.  
Recommended torque : 117.5 〜 147N・cm  
ꢀꢀ  
(12 〜 15Kgf・cm)  
Flat Diameter:  
9.5±0.2  
Flat Diameter:9.5±0.2  
0.21+-0.213  
(Gap between body and contact)  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  
14  
TNCꢀSeries  
Unit:mm  
○ Assembly Instruction(7)  
Parts Configulration  
Insulator  
Contact  
Body  
Ferule  
Heat-shrinkable tube  
Cable length which require for the cable assembly.  
ꢀL=L1-10.5  
L1  
Cable  
Outer Conductor  
Insert the heat-shrinkable tube into the cable.  
ꢀCut the cable as fig.1.  
15+1  
0
ꢀ Note)Please be careful to not damage the outer conductor.  
Sheath  
Heat-shrinkable tube  
Ferule  
② Insert the ferule on the outer conductor  
Pick and spread the outer conductor.  
Pick and spread the top  
Insulator  
Center Conductor  
Pre-soldering  
and  
③ Turn down the outer conductor to the ferule  
cut the outer conductor as fig.3.  
ꢀ Cut the insulator as fig. 3 and pre-solder the center  
conductor. And cut the center conductor as fig.3.  
ꢀ Note)Please be careful to not center conductor.  
0
2.9-1  
4±0.5  
(9.7)  
No gap  
Soldering  
Contact  
cable, solder up the  
④ Insert the insulator into the  
contact with center conductor.  
ꢀNote)When the solder is stick out, please shave the  
extra solder along the contact.  
Insulator  
Interface Dimension  
⑤ Insert the body into the above cable assembly and  
crimp the root of the body.  
±0.25  
4.98  
(between contact and washer  
ꢀNote)When inserting the body, match the contact notch  
with projection of insulator.  
Dies:A  
ꢀNote)Crimp the body with same level of body and dies.  
ꢀNote)Meet the interface dimension and crimp heightꢀ  
Cable assembly  
Same level  
Body  
Body Surface  
a
Measurering point  
L/2  
Crimp Height  
L
ꢀaeach sides)  
~50  
on the root of the  
⑥ Cover the heat-shrinkable tube  
body and heat up.  
Heat-shrinkable tube  
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.  
ꢀMoreover, the characteristic and the specification of the published product are the reference values.  
ꢀPlease confirm the content with the latest delivery specifications when you use the product.  
http://www.ddknet.co.jp  

相关型号:

TNC-J-3D2W-CR10-CF

TNC Style Connector
DDK

TNC-J-C-F-ST-BH1

RF TNC Connector, Female, Panel Mount, Cable Mount, Crimp Solder Terminal, Jack, ROHS COMPLIANT
SAMTEC

TNC-J-C-GF-ST-BH2

RF TNC Connector
SAMTEC

TNC-J-C-GN-SR-BH1

RF TNC Connector
SAMTEC

TNC-J-C-GN-SR-BH2

RF TNC Connector
SAMTEC

TNC-J-C-GN-ST-BH1

RF TNC Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Crimp Solder Terminal, Locking, Jack, ROHS COMPLIANT
SAMTEC

TNC-J-C-GN-ST-BH2

RF TNC Connector, Female, Panel Mount, Cable Mount, Crimp Solder Terminal, Jack
SAMTEC

TNC-J-C-H-ST-BH1

RF TNC Connector, Female, Panel Mount, Cable Mount, Jack
SAMTEC

TNC-J-C-HF-ST-BH2

RF TNC Connector
SAMTEC

TNC-J-C-HN-ST-BH1

RF TNC Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Crimp Solder Terminal, Locking, Jack, ROHS COMPLIANT
SAMTEC

TNC-J-C-HN-ST-BH2

RF TNC Connector
SAMTEC

TNC-J-C-MN-ST-BH1

RF TNC Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Crimp Solder Terminal, Locking, Jack, ROHS COMPLIANT
SAMTEC