AB60S2400A [DELTA]
AC/DC Power Module 60W, Industrial & Medical Safety;型号: | AB60S2400A |
厂家: | DELTA ELECTRONICS, INC. |
描述: | AC/DC Power Module 60W, Industrial & Medical Safety 输入元件 光电二极管 |
文件: | 总5页 (文件大小:393K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AB60S Series
AC/DC Power Module 60W, Industrial & Medical Safety
FEATURES
Fully encapsulated Plastic Case
3 Mounting Versions:
- PCB Mounting with Solder Pins
- Chassis Mounting with Screw Terminals
- DIN-Rail Mounting
Package Dimension 88.9x67.5x34.2 mm (PCB
Mounting Version)
Universal Input 85-264VAC, 47-440 Hz
Protection Class ll
Extended Operating Temp.Range -40°C to +60°C
at full Load
LED Output Indicator (Chassis Version Models)
Industrial Safety to UL/cUL/IEC/EN 60950-1 and
UL508
Medical Safety Approval to UL/cUL/IEC/EN
60601-1 3rd Edition
Over Load Protection
3 Year Product Warranty
The new AB60S series is a range of fully encapsulated AC/DC power modules. These high performance products feature an
extended operating temperature range of -40°C to +80°C. Universal input voltage 85-264VAC and UL/IEC/EN safety approvals
including medical safety and UL508 listing qualify these power supplies modules for applications in products with worldwide
markets.EMI-filter meets EN55022, class B and FCC,part15, class B.
The AB60S series power modules provide an economical solution for many space critical applications in commercial, medical and
industrial electronic equipment.
Model Selection Guide
Model Number PCB Mounting
Output
Output Current
Input Current
115VAC, 60Hz 230VAC, 50Hz
@Max. Load
Max. capacitive
Load
Efficiency
Voltage
(typ.)
Max.
mA
@Max. Load, 115VAC
VDC
5.1
12
mA(typ.)
μF
%
84
87
87
87
88
AB60S0500A
AB60S1200A
AB60S1500A
AB60S2400A
AB60S4800A
10000
5000
4000
2500
1250
880
1000
1000
1000
988
528
600
600
600
593
8000
3900
3300
1500
680
15
24
48
DS_AB60S_06162014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P1
Input Specifications
Parameter
Model
Min.
85
Typ.
---
Max.
264
440
370
---
Unit
VAC
Hz
AC Voltage Input Range
Input Frequency Range
DC Voltage Input Range
No-Load Power Consumption
47
---
All Models
120
---
---
VDC
W
0.5
---
115VAC
230VAC
---
30
A
Inrush Current (Cold Start at 25℃)
---
---
60
A
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Conditions
Min.
---
Typ.
±1.0
±0.2
±0.5
Max.
±2.0
±1.0
±1.0
Unit
%
%
%
Vin=Min. to Max.
Iout=Min. to Max.
---
Load Regulation
Min.Load
---
No minimum Load Requirement
(5.1VDC Output Models)
(Other Output Models)
---
---
---
---
---
2.0
1.0
3.0
1.5
---
---
5
%VPP of Vo
%VPP of Vo
% of Vo
%/℃
Ripple & Noise
0-20 MHz Bandwidth
Over Voltage Protection
Temperature Coefficient
Overshoot
Zener diode clamp
120
±0.02
---
%
85VAC, Hiccup Mode, auto-recovery
Current Limitation
105
---
---
%Inom.
(long term overload condition may cause damage)
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
General Specifications
Parameter
I/O Isolation Voltage (reinforced)
Leakage Current
Conditions
500 VDC
Min.
4000
---
Typ.
---
Max.
---
Unit
VACrms
μA
80
---
I/O Isolation Resistance
Switching Frequency
1000
---
---
---
MΩ
100
20
---
KHz
ms
115VAC, 60Hz
230VAC, 50Hz
---
---
Hold-up Time
---
80
---
ms
MIL-HDBK-217F@25℃, Ground
Benign
MTBF (calculated)
Protection Class II
Safety Approvals
125,000
---
---
Hours
According IEC/EN 60536
IEC/EN 60950-1, 60601-1 3rd, 2XMOPP
cUL/UL 60950-1, 60601-1 3rd, 2XMOPP, UL 508 listed
EMC Specifications
Parameter
Conducted and radiated EMI
ESD
Standards & Level
Performance
Class B
EN55011, EN55022, FCC part 15
EN61000-4-2 air ± 8kV , Contact ± 4kV
EN61000-4-3 10V/m
A
A
A
A
A
A
A
B
Radiated immunity
Fast transient
Surge
EN61000-4-4 ± 2kV
EN61000-4-5 ±1kV
EN61000-4-6 10Vrms
Conducted immunity
PFMF
EN61000-4-8 30A/m
EN61000-4-11 30% 10ms
EN61000-4-11 >95% 5000ms
Dips
Interruption
DS_AB60S_06162014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P2
Environmental Specifications
Parameter
Temperature Range (operational)
Power Derating
Conditions
Ambient
Min.
Max.
+80℃
2.3W / ℃
+95℃
-40℃
Above +60℃
-40℃
---
Storage Temperature Range
Humidity (non condensing)
Cooling
95% rel. H
Free-Air convection
Notes
1
This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control
systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage, after warm-up time rated output current unless
otherwise noted.
2
3
4
5
6
7
8
9
Safety approvals cover frequency 47-63 Hz.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
To order the module with chassis mount package, please add a suffix C (e.g. AB60S1500C).
To order the module in chassis mount with DIN-Rail kit, please add a suffix D (e.g. AB60S1500D).
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications PCB Mounting
Mechanical Dimensions
Pin Connections
Pi
n
25.4 [1.00]
Function
1
2
4
6
AC (N)
AC (L)
+Vout
-Vout
6
4
17.75
[0.70]
Mounting M4 Thread
Bottom View
2
1
►All dimensions in mm (inches)
►Tolerance: ±1.0 (±0.04)
►Pin diameter 1.0 ±0.1
(0.04±0.004)
55.88 [2.20]
67.5 [2.66]
0.7 [0.03]
34.2 [1.35]
6.0 [0.24]
Physical Characteristics
Case Size
Case Material
Pin Material
Weight
:
:
:
:
88.9x67.5x34.2mm (3.50x2.66x1.35 inches)
Plastic resin (flammability to UL 94V-0 rated)
Copper Alloy with Gold Plate Over Nickel Subplate
360g
DS_AB60S_06162014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P3
Package Specifications Chassis Mounting (order code suffix C)
Mechanical Dimensions
Connections
Pi
n
4x 3.5
Function
1
2
3
4
5
6
7
AC (N)
AC (L)
NC
7
6
5
4
3
2
1
Top View
+Vout
NC
Indication LED
DC-
ON
-Vout
NC
POWER"GOOD"INDICATOR
100.0 [3.94]
112.0 [4.41]
NC: No Connection
90.0 [3.54]
11.0 [0.43]
►All dimensions in mm (inches)
►Tolerance: ±1.0 (±0.04)
Physical Characteristics
Case Size
Case Material
Weight
:
:
:
112.0x67.8x38.0mm (4.41x2.67x1.50 inches)
Plastic resin (flammability to UL 94V-0 rated)
380g
Package Specifications with DIN Rail Mounting Bracket (order code suffix D)
Mechanical Dimensions
4x 3.5
7
6
2
5
Top View
1
4
Indication LED
3
DC-
ON
POWER"GOOD"INDICATOR
100.0 [3.94]
112.0 [4.41]
90.0 [3.54]
11.0 [0.43]
DS_AB60S_06162014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P4
Physical Characteristics
Case Size
Case Material
Weight
:
:
:
112.0x67.8x38.0mm (4.41x2.67x1.50 inches)
Plastic resin (flammability to UL 94V-0 rated)
433g
DIN-Rail Mounting Bracket
Part Numbering System
A
B
60
S
05
00
A
Number of
Outputs
Output
Voltage I
Output
Voltage II
Product type
Family series
Watt
Option Code
Medical
00 - not
A - PCB Mount
AC/DC Power Module
60 – 60W
S - Single
05 - 5.1V
application
applicable
12 - 12V
15 - 15V
24 - 24V
48 - 48V
C - Chassis Mount
D - Din Rail Mount
CONTACT: www.deltaww.com/dcdc
USA:
Europe:
Asia & the rest of world:
Telephone:
Phone: +31-20-655-0967
Fax: +31-20-655-0999
Email: DCDC@delta-es.com
Telephone: +886 3 4526107
ext 6220~6224
Fax: +886 3 4513485
Email: DCDC@delta.com.tw
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: DCDC@delta-corp.com
WARRANTY
Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request
from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor
for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice
DS_AB60S_06162014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P5
相关型号:
©2020 ICPDF网 联系我们和版权申明