FEATURES
High efficiency: 92.3% @ 3.3V/60A
Size:
58.4x22.8x10.9mm (2.30”x0.90”x0.43”)
(Without heat-spreader)
58.4x22.8x12.7mm (2.30”x0.90”x0.50”)
(With heat-spreader)
Industry standard footprint
Heat dissipation enhancement pinout
Fixed frequency operation
SMD and through-hole versions
Input UVLO
OTP and output OCP, OVP
Output voltage trim: -20%, +10%
Monotonic startup into normal and
pre-biased loads
2250V isolation and basic insulation
No minimum load required
No negative current during power or enable
on/off
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS18001 certified manufacturing facility
UL/cUL 60950-1 (US & Canada) Recognized
Delphi Series E48SP3R360, 1/8th Brick 200W
DC/DC Power Modules: 48V in, 3.3V, 60A out
The Delphi Series E48SP3R360, 1/8th Brick, 48V input, single
output, isolated DC/DC converter, is the latest offering from a world
leader in power systems technology and manufacturing ― Delta
Electronics, Inc. This product family provides up to 200 watts of
power or 60A of output current (3.3V and below) in an industry
standard 1/8th brick form factor (2.30” x 0.90”). The 3.3V output
offers one of the highest output currents available and provides up to
92.3% efficiency at full load. With heat dissipation enhancement
pinout, creative design technology and optimization of component
placement, these converters possess outstanding electrical and
thermal performance, as well as extremely high reliability under
highly stressful operating conditions. All modules are protected from
abnormal input/output voltage, current, and temperature conditions.
OPTIONS
SMD pins
Short pin lengths available
Positive remote On/Off
Heat spreader
APPLICATIONS
Optical Transport
Data Networking
Communications
Servers
DATASHEET
DS_E48SP3R360_06052012
TECHNICAL SPECIFICATIONS
(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
E48SP3R360 (Standard)
Min.
Typ.
Max.
Units
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
80
100
118
Vdc
Vdc
°C
Transient (100ms)
100ms
Operating Case Temperature (Without heat spreader)
Operating Case Temperature (With heat spreader)
Storage Temperature
Refer to figure 20 for measuring point
Refer to figure 22 for measuring point
-40
-40
-55
106
125
2250
°C
°C
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Input Voltage
Vdc
36
75
Vdc
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
32.5
30.5
1.5
34
32
2
35.5
33.5
2.5
Vdc
Vdc
Vdc
A
100% Load, 36Vin
5.9
80
8
6.5
No-Load Input Current
120
12
1
9.0
0.25
30
mA
mA
Off Converter Input Current
Inrush Current (I2t)
Start up Current
With 100uF external input capacitor
Peak, Vin=36V, 100% Load, With 10000uF Co
A2s
A
6.5
Input Terminal Ripple Current
Input Reflected-Ripple Current
Input Voltage Ripple Rejection
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Load
RMS, Vin=48V, With 100uF input cap.
P-P thru 12µH inductor, 5Hz to 20MHz
120 Hz
0.15
20
A
mA
45
dB
Vin=48V, Io=Io.max, Tc=25°C
3.25
3.2
3.3
3.35
Vdc
Io=Io, min to Io, max
Vin=36V to 75V
±5
±5
±10
±10
mV
mV
mV
V
Over Line
Over Temperature
Tc=-40°C to125°C
±33
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
Over sample load, line and temperature
5Hz to 20MHz bandwidth
3.4
Full Load, 1µF ceramic, 10µF tantalum
Full Load, 1µF ceramic, 10µF tantalum
80
30
120
45
mV
mV
A
RMS
Operating Output Current Range
Output Over Current Protection
DYNAMIC CHARACTERISTICS
Output Voltage Current Transient
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time (within 1% Vout nominal)
Turn-On Transient
0
60
Output Voltage 10% Low
110
150
%
48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs
50% Io.max to 75% Io.max
50
50
100
100
200
mV
mV
us
75% Io.max to 50% Io.max
100
Start-Up Time, From On/Off Control
Start-Up Time, From Input
28
28
40
40
ms
ms
Cap ESR>=15mohm;
Maximum Output Capacitance
0
10000
µF
Full load; 5% overshoot of Vout at startup;
EFFICIENCY
100% Load
Vin=48V
Vin=48V
91.3%
92%
92.3%
93%
%
%
60% Load
ISOLATION CHARACTERISTICS
Input to Output
2250
Vdc
MΩ
pF
Isolation Resistance
10
Isolation Capacitance
1500
250
FEATURE CHARACTERISTICS
Switching Frequency
kHz
ON/OFF Control, Negative Remote On/Off logic
Logic Low (Module On)
Logic High (Module Off)
ON/OFF Control, Positive Remote On/Off logic
Logic Low (Module Off)
Logic High (Module On)
Von/off
Von/off
-0.7
2
0.8
15
V
V
Von/off
Von/off
Ion/off at Von/off=0.0V
-0.7
2
0.8
15
0.3
V
V
mA
ON/OFF Current (for both remote on/off logic)
ON/OFF Current (for both remote on/off logic)
Leakage Current (for both remote on/off logic)
Output Voltage Trim Range
Ion/off at Von/off=2V
10
uA
uA
%
Logic High, Von/off=5V
50
10
Pout ≦ max rated power
-20
Pout ≦ max rated power
Output Voltage Remote Sense Range
Output Over-Voltage Protection
GENERAL SPECIFICATIONS
MTBF
10
%
Over full temp range; % of nominal Vout
130
145
%
Io=50% of Io, max; Ta=25°C, airflow rate=400FLM
Without heat-spreader
4.79
27.8
36.8
135
116
M hours
grams
grams
°C
Weight
Weight
With heat-spreader
Over-Temperature Shutdown (Without heat spreader)
Over-Temperature Shutdown (With heat spreader)
Refer to figure 20 for measuring point
Refer to figure 22 for measuring point
°C
2
DS_E48SP3R360_06052012
ELECTRICAL CHARACTERISTICS CURVES
20
18
16
14
12
10
8
96.0
94.0
92.0
90.0
88.0
86.0
84.0
82.0
80.0
78.0
6
4
2
0
12
24
36
48
60
12
24
36
48
60
Output Current (A)
Output Current (A)
36Vin
48Vin
75Vin
36Vin
48Vin
75Vin
Figure 1: Efficiency vs. load current for minimum, nominal, and
Figure 2: Power dissipation vs. load current for minimum,
maximum input voltage at 25°C
nominal, and maximum input voltage at 25°C.
8
7
6
5
4
3
2
1
0
30
35
40
45
50
55
60
65
70
75
INPUT VOLTAGE(V)
Figure 3: Typical full load input characteristics at room
temperature
3
DS_E48SP3R360_06052012
ELECTRICAL CHARACTERISTICS CURVES
For Negative Remote On/Off Start up
Figure 4: Turn-on transient at full rated load current
(4 ms/div). Vin=48V. Top Trace: Vout, 1.0V/div;
Bottom Trace: ON/OFF input, 2V/div
Figure 5: Turn-on transient at zero load current
(4 ms/div). Vin=48V. Top Trace: Vout: 1.0V/div,
Bottom Trace: ON/OFF input, 2V/div
For Input Voltage Start up
Figure 6: Turn-on transient at full rated load current
(4 ms/div). Vin=48V. Top Trace: Vout, 1.0V/div;
Bottom Trace: Vin , 30V/div
Figure 7: Turn-on transient at zero load current
(4 ms/div). Vin=48V. Top Trace: Vout, 1.0V/div;
Bottom Trace: Vin, 30V/div
0
0
0
0
Figure 8: Output voltage response to step-change in
load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs).
Load cap: 10µF tantalum capacitor and 1µF ceramic
capacitor. Top Trace: Vout (100mV/div, 200us/div),
Bottom Trace: Iout (20A/div). Scope measurement
should be made using a BNC cable (length shorter than
20 inches). Position the load between 51 mm to 76 mm
(2 inches to 3 inches) from the module
Figure 9: Output voltage response to step-change in
load current (75%-50%-75% of Io, max; di/dt
=
1.0A/µs). Load cap: 10µF tantalum capacitor and 1µF
ceramic capacitor. Top Trace: Vout (100mV/div,
200us/div), Bottom Trace: Iout (20A/div). Scope
measurement should be made using a BNC cable
(length shorter than 20 inches). Position the load
between 51 mm to 76 mm (2 inches to 3 inches) from
the module
4
DS_E48SP3R360_06052012
ELECTRICAL CHARACTERISTICS CURVES
is
ic
Vin+
Vin-
0
+
+
Cs: 220uF
100uF,
ESR=0.2 ohm @
25oC 100KHz
Figure 10: Test set-up diagram showing measurement points for
Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (LTEST) of 12 µH. Capacitor Cs offset possible
battery impedance. Measure current as shown above
Figure 11: Input Terminal Ripple Current, ic, at full rated
output current and nominal input voltage with 12µH
source impedance and 100µF electrolytic capacitor (200
mA/div, 2us/div)
Copper Strip
Vo(+)
0
SCOPE
RESISTIVE
LOAD
10u
1u
Vo(-)
Figure 12: Input reflected ripple current, is, through a 12µH
source inductor at nominal input voltage and rated load
current (20 mA/div, 2us/div)
Figure 13: Output voltage noise and ripple
measurement test setup
0
Figure 14: Output voltage ripple at nominal input voltage
and rated full load current (100 mV/div, 1us/div)
Load capacitance: 1µF ceramic capacitor and 10µF
tantalum capacitor. Bandwidth: 20 MHz. Scope
measurements should be made using a BNC cable (length
shorter than 20 inches). Position the load between 51 mm
to 76 mm (2 inches to 3 inches) from the module.
5
DS_E48SP3R360_06052012
Safety Considerations
DESIGN CONSIDERATIONS
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950,
CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and
IEC60950-1999, if the system in which the power
module is to be used must meet safety agency
requirements.
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules and
affect the stability. A low ac-impedance input source is
recommended. If the source inductance is more than a
few µH, we advise adding a 33 to 100 µF electrolytic
capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the
input of the module to improve the stability.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2 or
SELV. An additional evaluation is needed if the source
is other than TNV-2 or SELV.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate in
a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB layout
issues, please contact Delta’s technical support team. An
external input filter module is available for easier EMC
compliance design. Below is the reference design for an
input filter tested with E48SP3R3XXXX to meet class B in
CISSPR 22.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If
the input source is a hazardous voltage which is greater
than 60 Vdc and less than or equal to 75 Vdc, for the
module’s output to meet SELV requirements, all of the
following must be met:
The input source must be insulated from the ac
mains by reinforced or double insulation.
The input terminals of the module are not operator
accessible.
Schematic and Components List
Vin(+) Vo( +)
If the metal baseplate is grounded, one Vi pin and
one Vo pin shall also be grounded.
CY1
Cin
DCDC
A SELV reliability test is conducted on the system
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
CX
LOAD
Vin
L1
Module
CY2
Vin(-)
Vo(-)
-
When installed into a Class II equipment (without
grounding), spacing consideration should be given to
the end-use installation, as the spacing between the
module and mounting surface have not been evaluated.
CY
Cin is 100uF*2 low ESR Aluminum cap;
CX is 2.2uF ceramic cap;
CY1 are 10nF ceramic caps;
CY2 are 10nF ceramic caps;
CY is 1nF ceramic cap;
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
L1 is common-mode inductor, L1=0.88mH;
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
Fast-acting fuse with 30A maximum rating to be
installed in the ungrounded lead. A lower rated fuse can
be used based on the maximum inrush transient energy
and maximum input current.
Test Result
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/or drying is especially important for un-encapsulated
and/or open frame type power modules. For assistance
on appropriate soldering and cleaning procedures,
please contact Delta’s technical support team.
48V Vin, Full load,
Yellow line is quasi peak mode;
Blue line is average mode.
6
DS_E48SP3R360_06052012
FEATURES DESCRIPTIONS
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
Over-Current Protection
The modules include an internal output over-current
protection circuit, which will endure current limiting for an
unlimited duration during output overload. If the output
current exceeds the OCP set point, the modules will
automatically shut down, and enter hiccup mode or latch
mode, which is optional.
For negative logic if the remote on/off feature is not used,
please short the on/off pin to Vi(-). For positive logic if the
remote on/off feature is not used, please leave the on/off
pin floating.
Vi(+)
Vo(+)
For hiccup mode, the module will try to restart after
shutdown. If the over current condition still exists, the
module will shut down again. This restart trial will continue
until the over-current condition is corrected.
Sense(+)
ON/OFF
Sense(-)
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Vi(-)
Vo(-)
Over-Voltage Protection
Figure 15: Remote on/off implementation
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. If this voltage exceeds the over-voltage
set point, the module will shut down, and enter in hiccup
mode or latch mode, which is optional.
Remote Sense
Remote sense compensates for voltage drops on the
output by sensing the actual output voltage at the point
of load. The voltage between the remote sense pins and
the output terminals must not exceed the output voltage
sense range given here:
For hiccup mode, the module will try to restart after
shutdown. If the over voltage condition still exists, the
module will shut down again. This restart trial will continue
until the over-voltage condition is corrected.
[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
This limit includes any increase in voltage due to remote
sense compensation and output voltage set point
adjustment (trim).
Over-Temperature Protection
The over-temperature protection consists of circuitry that
provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold the
module will shut down, and enter in auto-restart mode or
latch mode, which is optional.
Vi(+) Vo(+)
Sense(+)
Sense(-)
For auto-restart mode, the module will monitor the module
temperature after shutdown. Once the temperature is
dropped and within the specification, the module will be
auto-restart.
Vi(-) Vo(-)
Contact
Resistance
Contact and Distribution
Losses
Figure 16: Effective circuit configuration for remote sense
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
operation
If the remote sense feature is not used to regulate the
output at the point of load, please connect SENSE(+) to
Vo(+) and SENSE(–) to Vo(–) at the module.
Remote On/Off
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the module
on during a logic low and off during a logic high. Positive
logic turns the modules on during a logic high and off
during a logic low.
The output voltage can be increased by both the remote
sense and the trim; however, the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
7
DS_E48SP3R360_06052012
FEATURES DESCRIPTIONS (CON.)
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Care should be taken to ensure that the maximum
output power does not exceed the maximum rated
power.
Output Voltage Adjustment (TRIM)
Figure 18: Circuit configuration for trim-up (increase output
voltage)
To increase or decrease the output voltage set point,
connect an external resistor between the TRIM pin and
either the SENSE(+) or SENSE(-). The TRIM pin
should be left open if this feature is not used.
If the external resistor is connected between the TRIM
and SENSE (+) the output voltage set point increases
(Fig. 19). The external resistor value required to obtain
a percentage output voltage change △% is defined
as:
5.11Vo (100 + ∆ ) 511
Rtrim − up =
−
−10.2(KΩ)
1.225 ∆
∆
Ex. When Trim-up +10% (3.3V×1.1=3.63V)
5.11×3.3× (100 +10) 511
Rtrim − up =
−
−10.2 = 90.1(KΩ)
Figure 17: Circuit configuration for trim-down (decrease
output voltage)
1.225×10
10
If the external resistor is connected between the TRIM
and SENSE (-) pins, the output voltage set point
decreases (Fig. 18). The external resistor value
required to obtain a percentage of output voltage
change △% is defined as:
Trim resistor can also be connected to Vo+ or Vo- but it
would introduce a small error voltage than the desired
value.
The output voltage can be increased by both the remote
sense and the trim, however the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
511
Rtrim − down =
−10.2
(
KΩ
)
∆
Ex. When Trim-down -10% (3.3V×0.9=2.97V)
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
511
Rtrim − down =
− 10.2
(
KΩ
)
= 40.9
(
KΩ
)
10
Care should be taken to ensure that the maximum
output power of the module remains at or below the
maximum rated power.
8
DS_E48SP3R360_06052012
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
PWB
MODULE
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
50.8 (2.0”)
AIR FLOW
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 19: Wind tunnel test setup
Thermal Derating
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power module
should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.
9
DS_E48SP3R360_06052012
THERMAL CURVES
THERMAL CURVES
(WITHOUT HEAT SPREADER)
(WITH HEAT SPREADER)
Figure 20: Temperature measurement location
Figure 22: Temperature measurement location
* The allowed maximum hot spot temperature is defined at 118℃ * The allowed maximum hot spot temperature is defined at 106℃
E48SP3R360(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Transverse Orientation)
E48SP3R360(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Transverse Orientation,With Heatspreader)
Output Current (A)
Output Current (A)
60
55
50
45
40
35
30
25
20
15
10
5
60
55
50
45
40
35
30
25
20
15
10
5
600LFM
Natural
Convection
Natural
Convection
100LFM
100LFM
200LFM
200LFM
300LFM
400LFM
300LFM
400LFM
500LFM
500LFM
55
600LFM
0
0
25
30
35
40
45
50
60
65
70
75
80
85
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Ambient Temperature (℃)
Figure 21: Output current vs. ambient temperature and air
velocity @Vin=48V(Transverse Orientation, without heat
spreader)
Figure 23: Output current vs. ambient temperature and air velocity
@Vin=48V(Transverse Orientation, with heat spreader)
10
DS_E48SP3R360_06052012
PICK AND PLACE LOCATION
RECOMMENDED PAD LAYOUT (SMD)
SURFACE-MOUNT TAPE & REEL
11
DS_E48SP3R360_06052012
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE
Peak temp.
2nd Ramp-up temp.
210~230°C 5sec.
1.0~3.0°C /sec.
250
Pre-heat temp.
140~180°C 60~120 sec.
200
Cooling down rate <3°C /sec.
Ramp-up temp.
0.5~3.0°C /sec.
150
100
50
Over 200°C
40~50sec.
0
60
120
Time ( sec. )
180
240
300
Note: The temperature refers to the pin of E48SP, measured on the pin +Vout joint.
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE
.
Temp
Peak Temp. 240 ~ 245 ℃
217℃
200℃
Ramp down
max. 4℃/sec.
Preheat time
100~140 sec.
150℃
25℃
Time Limited 90 sec.
above 217℃
Ramp up
max. 3℃/sec.
Time
Note: The temperature refers to the pin of E48SP, measured on the pin +Vout joint.
12
DS_E48SP3R360_06052012
MECHANICAL DRAWING(WITHOUT HEAT-SPREADER)
Surface-mount module
Through-hole module
Pin No.
Name
Function
1
+Vin
Positive input voltage
2
ON/OFF
-Vin
Remote ON/OFF
3
Negative input voltage
Negative output voltage
Negative output voltage
Negative remote sense
Output voltage trim
4
-Vout
5
-Vout
6
-SENSE
TRIM
7
8
+SENSE
+Vout
+Vout
Positive remote sense
Positive output voltage
Positive output voltage
9
10
13
DS_E48SP3R360_06052012
MECHANICAL DRAWING(WITH HEAT-SPREADER)
* For modules with through-hole pins and the optional heatspreader, they are intended for wave soldering
assembly onto system boards; please do not subject such modules through reflow temperature profile.
Pin No.
Name
Function
1
+Vin
Positive input voltage
2
ON/OFF
-Vin
Remote ON/OFF
3
Negative input voltage
Negative output voltage
Negative output voltage
Negative remote sense
Output voltage trim
4
-Vout
5
-Vout
6
-SENSE
TRIM
7
8
+SENSE
+Vout
+Vout
Positive remote sense
Positive output voltage
Positive output voltage
9
10
14
DS_E48SP3R360_06052012
PART NUMBERING SYSTEM
E
48
S
P
3R3
60
N
R
F
A
Type of
Product Voltage Outputs
Input Number of Product
Output
Voltage
Output
Current
ON/OFF
Logic
Pin
Length/Type
Option Code
Series
E - 1/8 Brick
48-
S - Single
P - High
Power
3R3 - 3.3V 60 - 60A
N- Negative
P- Positive
R - 0.170”
N - 0.145”
M-SMD
A - Standard Functions
H - with Heatspreader
F- RoHS 6/6
(Lead Free)
36V~75V
MODEL LIST
MODEL NAME
INPUT
OUTPUT
EFF @ 100% LOAD
E48SP3R360NRFA
36V~75V
7.5A
3.3V
60A
92.3%
Default remote on/off logic is negative and pin length is 0.170”
For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office.
CONTACT: www.delta.com.tw/dcdc
USA:
Telephone:
Asia & the rest of world:
Telephone: +886 3 4526107
Ext 6220~6224
Europe:
Phone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email: DCDC@delta-es.com
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: DCDC@delta-corp.com
Fax: +886 3 4513485
Email: DCDC@delta.com.tw
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications
at any time, without notice.
15
DS_E48SP3R360_06052012
相关型号:
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_2.jpg)
E48SP3R360PMFH
Delphi Series E48SP3R360, 1/8th Brick 200W DC/DC Power Modules: 48V in, 3.3V, 60A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_2.jpg)
E48SP3R360PNFA
Delphi Series E48SP3R360, 1/8th Brick 200W DC/DC Power Modules: 48V in, 3.3V, 60A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_2.jpg)
E48SP3R360PNFH
Delphi Series E48SP3R360, 1/8th Brick 200W DC/DC Power Modules: 48V in, 3.3V, 60A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_2.jpg)
E48SP3R360PRFA
Delphi Series E48SP3R360, 1/8th Brick 200W DC/DC Power Modules: 48V in, 3.3V, 60A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00200/img/page/E48SP3_1131491_files/E48SP3_1131491_2.jpg)
E48SP3R360PRFH
Delphi Series E48SP3R360, 1/8th Brick 200W DC/DC Power Modules: 48V in, 3.3V, 60A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_2.jpg)
E48SR05012
Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 5.0V/12A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_2.jpg)
E48SR05012NCFA
Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 5.0V/12A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_2.jpg)
E48SR05012NKFA
Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 5.0V/12A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_2.jpg)
E48SR05012NMFA
Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 5.0V/12A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_2.jpg)
E48SR05012NNFA
Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 5.0V/12A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012NRFA_613417_files/E48SR05012NRFA_613417_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012NRFA_613417_files/E48SR05012NRFA_613417_2.jpg)
E48SR05012NRFA
Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 1.2V/25A out
DELTA
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_1.jpg)
![](http://pdffile.icpdf.com/pdf1/p00113/img/page/E48SR05012_613420_files/E48SR05012_613420_2.jpg)
E48SR05012PCFA
Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 5.0V/12A out
DELTA
©2020 ICPDF网 联系我们和版权申明