FL75L07-A

更新时间:2024-09-18 12:41:14
品牌:DELTA
描述:Small size: 25.4mm x 25.4mm x 12.0mm

FL75L07-A 概述

Small size: 25.4mm x 25.4mm x 12.0mm 体积小: 25.4毫米X 25.4毫米X 12.0毫米

FL75L07-A 数据手册

通过下载FL75L07-A数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
FEATURES  
Š
RoHS Compliant  
Š
Small size: 25.4mm x 25.4mm x 12.0mm  
(1.0” x 1.0” x 0.47”)  
Š
Š
Š
Industry standard footprint and pin-out  
Surface mount or through hole pins  
Optimized for use with high frequency  
board mounted DC/DC converters  
Printed-circuit board mountable  
Š
Š
ISO 9001, TL 9000, ISO 14001, QS 9000,  
OHSAS 18001 certified manufacturing facility  
UL/cUL 60950 (US & Canada) Recognized,  
VDE 0805 (IEC60950) Licensed  
Š
Delphi Series Filter Module - FL75L07  
0~75Vdc input, 7A Current Rating  
The Delphi series FL75L07 filter module is the latest offering from a  
world leader in power systems technology and manufacturing – Delta  
Electronics, Inc. This filter module is designed to reduce the conducted  
common-mode and differential-mode noise on input or output lines of  
high-frequency switching power supplies and has a maximum current  
rating of 7A. It has the industry standard footprint and pin-out. With  
creative design technology and optimization of component placement,  
Delphi FL75L07 filter module possesses outstanding electrical and  
thermal performance, as well as extremely high reliability under highly  
stressful operating conditions.  
APPLICATIONS  
Š
Common-mode and differential-mode  
filtering of power supply dc input and  
output line  
Š
Š
Computer application  
Communications equipment  
DATASHEET  
DS_FL75L07_ 02162012  
SPECIFICATIONS  
GENERAL SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
Input voltage, operation  
Typical  
0~75V  
Common-mode Insertion Loss  
50Ω circuit, 500 kHz (Typ)  
40dB  
70dB  
Input voltage, continuous Typical  
0~100V  
Differential-mode Insertion Loss 50Ω circuit, 500 kHz (Typ)  
Operating temperature  
Storage temperature  
Size  
Typical  
Typical  
-40~ 115℃  
-55~ 125℃  
(1.0”. x 1.0”x 0.47”). 25.4 x 25.4 x 12.0 mm  
ELECTRICAL CHARACTERISTICS CURVES  
Figure 2: Typical differential-mode insertion loss in a 50Ω  
Figure 1: Typical common-mode insertion loss in a 50Ω circuit  
circuit  
Internal Schematics  
Figure 3: Internal schematics  
DS_FL75L07_02162012  
2
THERMAL CURVES  
THERMAL CONSIDERATIONS  
Thermal management is an important part of the system  
design. To ensure proper, reliable operation, sufficient  
cooling of the power module is needed over the entire  
temperature range of the module. Convection cooling is  
usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
Thermal Testing Setup  
Delta’s filter modules are characterized in heated  
vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
Figure 5: Temperature measurement location  
The allowed maximum hot spot temperature is defined at 115  
FL75L07 A (Standard) Output Current vs. Ambient Temperature and Air Velocity  
@ Vin = 48V (Either Orientation)  
Output Current (A)  
8
7
6
5
The following figure shows the wind tunnel  
characterization setup. The filter module is mounted on  
a test PWB and is vertically positioned within the wind  
tunnel. The space between the neighboring PWB and  
the top of the power module is 6.35mm (0.25”).  
Natural  
Convectio  
4
100LFM  
3
Thermal Derating  
200LFM  
2
300LFM  
1
Heat can be removed by increasing airflow over the  
module. Figure 4 shows maximum output is a function of  
ambient temperature and airflow rate. To enhance  
system reliability, the power module should always be  
operated below the maximum operating temperature. If  
the temperature exceeds the maximum module  
temperature, reliability of the unit may be affected.  
0
25  
35  
45  
55  
65  
75  
85  
Ambient Temperature (  
)
Figure 6: Output Current vs. Ambient Temperature and Air  
Velocity @ Vin = 48V (Either Orientation)  
PWB  
MODULE  
FACING PWB  
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
MEASURED BELOW  
THE MODULE  
50.8 (2.0”)  
AIR FLOW  
10 (0.4”)  
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)  
Figure 4: Wind tunnel test setup  
DS_FL75L07_02162012  
3
APPLICATION  
Note: C2 & C3 can be 0.01μF to 0.1μF. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended value  
suggested in the power module data sheet.  
Figure 7. Recommended schematic when used as the input filter to a high-frequency with open-frame dc-to-dc converter  
Note: Avoid routing signals or planes under the power module or the filter module. Please ensure all connections are low impedance.  
Figure 8. Recommended layout when used as the input filter to a high-frequency with open-frame dc-to-dc converter  
DS_FL75L07_02162012  
4
APPLICATION (Continued)  
Note: C2 through C5 can be 0.01μF to 0.1μF. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended  
value suggested in the power module data sheet.  
Figure 9. Recommended schematic when used as the input filter to a high-frequency with metal-cased dc-to-dc converter  
Note: Avoid routing signals or planes under the power module or the filter module. Please ensure all connections are low impedance.  
Figure10. Recommended layout when used as the input filter to a high-frequency with metal-cased dc-to-dc converter  
DS_FL75L07_02162012  
5
APPLICATION (Continued)  
Note: : C2 through C5 and C6 through C9 can be 0.01μF to o.1μF. Select the voltage rating to meet input-to-output isolation requirements. C1 should be  
the recommended value suggested in the power module datasheet.  
Figure 11. Recommended schematic of filter module with two power modules ( metal -cased )  
DS_FL75L07_02162012  
6
Figure 12 shows the experimental result obtained by using this filter module, together with the recommended external  
components shown in Figures 7 and 8. The Q48SB12025NR A module is one of the Delphi series quarter brick 12V, 25A  
DCDC converters. Measured noise is greatly dependent on layout, grounding, cable orientation, and load characteristics  
and the variation is possible from various application conditions.  
Figure 13. Q48SB12025NR A conducted noise with FL75L07A input filter  
MECHANICAL DRAWING(SMD)  
Top View  
Side View  
Bottom View  
Dimensions are in millimeter  
Tolerances : x.xx ± 0.5 mm (0.02 in), x.xxx ± 0.25 mm (0.010 in)  
DS_FL75L07_02162012  
7
MECHANICAL DRAWING(Through hole)  
12.2(0.48)  
25.4(1.00)  
19.80(0.780)  
2.8(0.11)  
2.6(0.10)  
Vo-  
Vin-  
G
Vin-  
Vo-  
L
I
L
O
A
G
N
E
D
0.75x0.6 (5x)  
(0.030x0.024)  
Vo+  
Vin+  
Vin+  
Vo+  
4.8(0.19)  
NOTES:  
DIMENSIONS ARE IN MILLIMETERS AND (INCHES)  
TOLERANCES: X.Xmm±0.5mm(X.XX in.±0.02 in.)  
X.XXmm±0.25mm(X.XXX in.±0.010 in.)  
1.20(0.047)  
Vin-  
Vo-  
G
Vin+  
Vo+  
19.80(0.780)  
25.4(1.00)  
2.8(0.11)  
RECOMMAMD PWB PAD LAYOUT  
DS_FL75L07_02162012  
8
PICK AND PLACE LOCATION(SMD)  
SURFACE-MOUNT TAPE & REEL  
RECOMMENDED PAD PATTERN (SMD)  
Note: Inside this filter module, the components have no  
voltage polarity. Hence, the input positive (Vin+) and input  
negative (Vin-) labels could be swaped for the  
convenience of layout and matching with power module  
input connected to the filter module, just remember to  
swap the output labels accordingly as well. Please refer to  
Figures 8 and 10 for how it is applied.  
DS_FL75L07_02162012  
9
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE  
Peak temp.  
2nd Ramp-up temp.  
210~230°C 5sec.  
1.0~3.0°C /sec.  
250  
Pre-heat temp.  
140~180°C 60~120 sec.  
200  
Cooling down rate <3°C /sec.  
Ramp-up temp.  
0.5~3.0°C /sec.  
150  
100  
50  
Over 200°C  
40~50sec.  
0
60  
120  
Time ( sec. )  
180  
240  
300  
Note: The temperature refers to the pin of filter 7A, measured on the pin 1 (+Vout ) joint.  
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE  
.
Temp  
Peak Temp. 240 ~ 245  
217  
200℃  
Ramp down  
max. 4/sec.  
Preheat time  
100~140 sec.  
150℃  
25℃  
Time Limited 90 sec.  
above 217℃  
Ramp up  
max. 3 /sec.  
Time  
Note: The temperature refers to the pin of filter 7A, measured on the pin 1 (+Vout ) joint.  
DS_FL75L07_02162012  
10  
PART NUMBERING SYSTEM  
FL  
75  
L
07  
Output Current  
7A  
A
Product Family  
FL- Filter  
Input Voltage  
0 ~ 75V  
Product Series  
L – standard  
Option Code  
A - Standard, SMD pins (7A only)  
B - Standard, through hole pins  
MODEL LIST  
Module Name  
FL75L05 A  
FL75L07 A  
FL75L10 A  
FL75L20 A  
Input Voltage (max.)  
Current Rating (max.)  
Size (metric)  
Size (English unit)  
1.0 in. x 1.0 in. x 0.4 in.  
1.0 in. x 1.0 in. x 0.47 in  
2.0 in. x 1.1 in. x 0.5 in.  
2.0 in. x 1.6 in. x 0.5 in.  
75V  
75V  
75V  
75V  
5A  
7A  
25.4 x 25.4 x 10.2 mm  
25.4 x 25.4 x 12.0 mm  
50.8 x 27.9 x 12.5 mm  
50.8 x 40.6 x 12.7 mm  
10A  
20A  
CONTACT: www.delta.com.tw/dcdc  
USA:  
Europe:  
Asia & the rest of world:  
Telephone:  
Telephone: +41 31 998 53 11  
Fax: +41 31 998 53 53  
Email: DCDC@delta-es.tw  
Telephone: +886 3 4526107 ext 6220  
Fax: +886 3 4513485  
Email: DCDC@delta.com.tw  
East Coast: (888) 335 8201  
West Coast: (888) 335 8208  
Fax: (978) 656 3964  
Email: DCDC@delta-corp.com  
WARRANTY  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for  
any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise  
under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.  
DS_FL75L07_02162012  
11  

FL75L07-A 相关器件

型号 制造商 描述 价格 文档
FL75L07A DELTA Delphi Series Filter Module 0~75Vdc input, 7A Current Rating 获取价格
FL75L07A_12 DELTA Small size: 25.4mm x 25.4mm x 12.0mm 获取价格
FL75L10 DELTA Industry standard footprint and pin-out 获取价格
FL75L10-A DELTA Small size: 25.4mm x 25.4mm x 12.0mm 获取价格
FL75L10A DELTA Delphi Series Filter Module 75Vdc input, 5A current Rating 获取价格
FL75L10B DELTA Industry standard footprint and pin-out 获取价格
FL75L20-A DELTA Small size: 25.4mm x 25.4mm x 12.0mm 获取价格
FL75L20A DELTA Delphi Series Filter Module 75Vdc input, 5A current Rating 获取价格
FL75L20A_12 DELTA Delphi Series Filter Module - FL75L20 75Vdc max input, 20A max output current 获取价格
FL7701 FAIRCHILD Single-Stage Primary-Side-Regulation PWM Controller for PFC and LED Dimmable Driving 获取价格

FL75L07-A 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6