PMC24V150W1BA [DELTA]

24V 300W 1 Phase; 24V 300W 1期
PMC24V150W1BA
型号: PMC24V150W1BA
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

24V 300W 1 Phase
24V 300W 1期

文件: 总14页 (文件大小:929K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
24V 300W 1 Phase  
Features:  
Full aluminium casing for  
lightweight and corrosion resistant  
handling  
Ease of wire connection to  
Terminals  
Remote On/Off function  
Remote Sense Function  
Built-In 12V STANDBY  
Active PFC Function, PF> 0.96  
Universal AC input  
Overload protection  
Over voltage protection  
Thermal protection  
MTBF:>700,000hrs  
Efficiency> 87%typ.  
Expected life time: 10 years  
2 year warranty  
RoHS compliant  
PMC-24V300W1BA  
Summary  
Delta’s Panel Mount Power Supply also offers  
overvoltage and overload protection. Using a  
wide input voltage range design, it is  
compatible worldwide. The input also includes  
DC operating voltage from 120-375Vdc. Best  
of all, this excellent design and quality does  
not come with a big price tag.  
The new Hi-End series with Remote Sense  
Function & 12V STANDBY / 0.5A Enclosed  
Power Supply is the latest offering from one of  
the  
world’s  
largest  
power  
supply  
manufacturers and solution providers - Delta.  
The product range offers a nominal output  
voltage of 24V, a wide temperature range  
from -10°C to +70°C and a highly dependable  
minimum holdup time.  
The state-of-the-art design is made to  
withstand harsh industrial environments. What  
makes the product stands out from the crowd  
is its lightweight full aluminum body design  
which can withstand shock and vibration  
according to IEC60068-2.  
1/1  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Technical Data  
PMC-24V300W1BA  
1.) Input Data  
Nominal AC Input Voltage  
Input Voltage range  
100 - 240VAC  
85 - 264VAC  
Nominal AC Input Frequency  
AC Input Frequency  
50Hz  
47 - 63Hz  
DC Input Voltage Range  
120 375VDC  
Max. Input Current  
Efficiency  
5.0A Max.(4.0A @ 115VAC, 2.0A @ 230VAC)  
> 87% @ 230VAC, > 86% @ 115VAC  
< 35A @ 115VAC, < 70A @ 230VAC  
< 1.0mA @ 240VAC  
VARISTOR  
Max. Inrush current limitation.(Cold Start)  
Leakage Current  
Transient surge voltage protection  
Input fuse, internal (device protection)  
Recommended backup fuse: Power circuit-breaker characteristic  
T 6.3 AH / 250V  
10A,16A : B  
2.) Output Data (24VDC)  
Max. Output Power  
300W  
Nominal Output Voltage  
24 VDC  
Tolerance  
Output Voltage Adjust Range  
Nominal Output Current  
+/- 2% (Initial Set Point tolerance)  
22 28 VDC  
12.5 A  
Line Regulation  
Load Regulation  
< 0.5% Typical @ 85 to 264VAC input, 100% load  
< 0.5% Typical @ rated input, 0 to 100% load  
Startup with capacitive loads  
Max 8,000µF (@ Nominal Input Voltage & Nominal O/P Voltage,25°C)  
Residual Ripple Voltage (20MHz BW @ 25°C)  
Total PARD (Peak switching 20MHz BW @ nominal values)  
Power Derating above +50°C ambient Temp.  
Rise Time  
< 100mVpp.  
< 150mVpp.  
Derated Linearly 2.5% / °C  
< 30 ms @ full load, 25°C  
Start-Up Time  
< 1.0 s @ full load, 25°C  
Main Buffering (Hold-Up Time ,Power failure bypass)  
Dynamic Response (Overshoot & Undershoot O/P Voltage)  
Parallel connection (Redundancy)  
Surge voltage protection against internal surge voltages  
> 15ms @ 115VAC & 230Vac, 25°C  
+/-5% of 0% - 100% load.  
YES ,with External Diode or Redundancy module (DRR-20A or DRR-40A)  
YES  
3.) Protection (24VDC)  
Over Voltage Protection  
Over load Protection  
Over current Protection  
Over Temperature Protection  
Short Circuit Protection  
> 32V +/-10%, SELV output, Non-Latching (Auto recovery).  
> 120% of rated load current, Auto Recovery (Hicc-up Mode).  
> 120% of rated load current, Auto Recovery (Hicc-up Mode).  
> 50°C Ambient Temp @ Max Load. Non-Latching (Auto-recovery.  
Bouncing mode and recovers automatically when the fault is removed.  
4.) Output Data (12Vaux)  
Max. Output Power  
6W  
Nominal Output Voltage  
12 VDC  
Tolerance  
Output Voltage Adjust Range  
Nominal Output Current  
+/- 5% (Initial Set Point tolerance)  
11.4 12.6 VDC  
0.5 A  
Line Regulation  
Load Regulation  
Total PARD (Peak switching 20MHz BW @ nominal values)  
Power Derating above +50°C ambient Temp.  
Rise Time  
< 0.5% Typical @ 85 to 264VAC input, 100% load  
< 0.5% Typical @ rated input, 0 to 100% load  
< 200mVpp.  
Derated Linearly 2.5% / °C  
< 30 ms @ full load, 25°C  
< 1.0 s @ full load, 25°C  
> 15ms @ 115VAC & 230Vac, 25°C  
+/-5% of 0% - 100% load.  
YES  
Start-Up Time  
Main Buffering (Hold-Up Time ,Power failure bypass)  
Dynamic Response (Overshoot & Undershoot O/P Voltage)  
Surge voltage protection against internal surge voltages  
5.) Protection (12Vaux)  
Over Voltage Protection  
Over load Protection  
Over current Protection  
Over Temperature Protection  
Short Circuit Protection  
> 16V +/-15%, SELV output, Non-Latching (Auto recovery).  
> 120% of rated load current, Auto Recovery (Hicc-up Mode).  
> 120% of rated load current, Auto Recovery (Hicc-up Mode).  
> 50°C Ambient Temp @ Max Load. Non-Latching (Auto-recovery.  
Bouncing mode and recovers automatically when the fault is removed.  
2/2  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
5.) Environmental  
Ambient temperature (Operating)  
-20°C to +50°C, with operation to 70°C possible with a linear derating to  
50% of nominal power from 50°C.  
-25°C to 85°C  
Ambient temperature (Storage)  
Humidity Operation  
Shock Test (in all directions)  
Vibration (in all X,Y,Z direction)  
(Non-Operating)  
< 95% RH non-condensing  
30G (300m/S2) according to IEC60068-2-27  
10 to 150Hz @ 50m/S2 (5G peak) according to IEC 60068-2-6.  
Note: all figures quoted are amplitudes (peak values).  
IEC/EN 60068-2-29; 11ms/ 10gn  
> 700,000 Hours.  
Bump  
MTBF  
Expected Life Time  
RoHS Compliant  
Altitude (Operating)  
Degree of protection  
Class of protection  
Pollution degree  
10 years.  
Yes, RoHS directive, WEEE directive  
@ 3,000 Meters  
IP20  
Class I with PE connection  
2
Climatic class  
3K3 according to EN 60721  
5.) Mechanical Data  
Dimension  
Cooling System  
Input Terminal & Output Terminal  
Mounting Rail  
199 mm X 105 mm X 41 mm (L X W X H)  
Fan Cooling (Built-in DC Fan)  
Terminal Block 7 pin (300VAC, 20A)  
Standard T35 Mounting Rail (35mm) EN60715  
Screw Terminal  
Connection  
Input wire size  
Output wire size  
Indicator  
Type of housing  
Weight  
AWG 20-16  
AWG 20-16  
Green LED “DC OK” LED (Same LED will Flicker upon fault)  
Aluminium  
0.820Kg  
6.) Certification/Safety Standards  
EMI : Immunity to interference according to EN 61000-6-2  
LEVEL 4  
15 KV / 8 KV  
LEVEL 3  
EN 61000-4-2 1)  
Discharge of static electricity (ESD):  
Air Discharge/Contact discharge:  
EN 61000-4-3 1)  
Housing:  
Frequency/Field intensity:  
Fast transients (Burst Immunity):  
Surge voltage Immunity:  
Common Mode/Differential Mode:  
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation.  
Radiate Field Immunity  
LEVEL 3 / 2KV4)  
EN 61000-4-4 1)  
IEC 61000-4-5 1)  
LEVEL 3  
2 KV3) / 1 KV4)  
LEVEL 3  
0.15MHz - 80MHz / 10Vrms.  
LEVEL 3 : 10A/Meter  
100% dip, Input: Main Buffering > 20ms.Self Recoverable  
EN 61000-4-6 1)  
I/O:  
Conducted Immunity  
Frequency / Uo:  
Power frequency magnetic field:  
Voltage dips:  
EN 61000-4-8 1)  
EN 61000-4-11 2)  
EMC : Noise emission according to EN 61000-6-3  
FCC Title 47, Class B / EN55022, CISPR22, CISPR11, CLASS B5  
FCC Title 47, Class B / EN55022, CISPR22, CISPR11, CLASS B5  
Emitted radio interface  
Radio interference voltage  
Galvanic Isolation :  
Input / output  
Input / PE  
output / PE  
type test/routine test :  
type test/routine test :  
type test/routine test :  
3KVAC  
1.5KVAC  
0.5KVAC  
Electrical equipment of machines  
Electronic equipment for use in electrical power Installations  
Safety entry low voltage  
EN60950-1 and IEC60204-1(With overvoltage category III)  
EN50178 and IEC62103  
PELV (EN60204), SELV (EN60950)  
UR/cUR recognize to UL60950-1 and CSA C22.2 No.60950-1,SIQ,CCC  
CB test certificate and report to IEC60950-1/EN60950-1  
CE (EMC and Low Voltage directive)  
DIN 57100-410  
Electrical Safety for Information technology equipment  
Electrical Safety for Industrial Control Equipment  
Protection against electric shock  
Conformance with EMC guideline 2004/108/EC  
and for low voltage guideline 2006/95/EC :  
Compliant with following standards :  
IEC60950-1/EN60950-1 : 2006/95/EC (Low Voltage Directive)  
EN55011 Class B  
: 2004/108/EC (EMC Directive)  
EN55022 Class B  
EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EN 61000 corresponds to IEC 61000  
1) Criterion A:  
2) Criterion B:  
Normal operating behavior within the defined limits.  
Temporary impairment to operational behavior that is corrected by the device itself.  
3) Symmetrical: Conductor to conductor.  
4) Asymmetrical: Conductor to ground.  
5) Class B:  
Area of application industry and residential.  
3/3  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Numbering for Panel Mount Power Supply  
For example: PMC-24V300W1BA  
XX X XXXX XXXX X XX  
XXXX……………Watt  
XX X XXXX XXXX X XX  
XX………………….Product Type  
035W  
050W  
075W  
100W  
150W  
35 Watt  
50 Watt  
75 Watt  
100 Watt  
150 Watt  
PM  
Panel Mount  
XX X XXXX XXXX X XX  
X………………….Model  
C
Enclose Power  
Supply  
XX X XXXX XXXX X XX  
X………………….Phase  
XX X XXXX XXXX X XX  
1
3
1 Phase  
3 Phase  
XXXX………………….Voltage  
24V  
24 Voltage  
XX X XXXX XXXX X XX  
XX………………….Variation (Eg,  
Customer, material,Etc.)  
BA  
Delta standard –  
product With Vsb  
4/4  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Block Diagrams/Connections:  
Block Diagram of Power Supply  
PMC-24V300W1BA  
5/5  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Engineering Data  
Derating Curve  
PMC-24V300W1BA  
Note:  
1. Do not use the Power Supply in areas  
outside the shaded portion as shown in  
the above graph, internal parts may  
Amb is lowered or load is reduced as  
far as necessary to keep device in  
working condition.  
occasionally  
damaged.  
deteriorate  
or  
be  
3. If the power supply has to be mounted  
in any other direction please contact  
your service provider.  
4. In order for the device to function in  
the manner intended, it is also  
necessary to observe lateral spacing of  
2 cm to other modules.  
5. Depending on the ambient temperature  
and load of the device, the temperature  
of the housing can become very high!  
2. For the power derating refer above  
graph ambient temperature > 50°C,  
the output capacity has to be reduced  
by 2.5% per Kelvin increase in  
temperature. If the output capacity is  
not reduced when Amb > 50°C device  
will run into thermal protection by  
switching off i.e. device will go in  
bouncing mode and will recover when  
6/6  
3/21/2011  
Rev: 01,  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Mechanical drawing  
7/7  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
8/8  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Over Load Protection  
The Power Supply is provided with an overload protection (OLP/OCP) function which protects the  
power supply from possible damage by over current. Additionally power supply also has over  
temperature protection (OTP) in case the over load condition persists for a longer duration and is  
below the overload trigger point but > 100% load.  
Typically the over load current (IOL) is > ISURGE (120%) output voltage will start drooping down when  
the power supply reaches max power limit and will run into bouncing mode when the output reaches  
UVLO (under voltage point). The output voltage will recover automatically when the overload  
condition is removed.  
Short Circuit Protection  
The Power Supply also has a short circuit protection which is in line with the overload protection and  
activates whenever there is a short across the output voltage, output goes in bouncing mode and  
remains until the fault is removed.  
Over Temperature Protection  
Additionally power supply also has over temperature protection (OTP) as mentioned above this OTP  
comes into picture when the over load condition persists for a longer duration and the output current  
level is below the overload trigger point but > 100% load.  
Also in the event of a higher ambient operating condition with 100% load the power supply will run  
into OTP when the Ambient temperature is > 55°C. The protection is self recoverable when activated  
output voltage bounces until the operating ambient temperature of the power supply is reduced or  
the power supply is used within its power derating curve.  
9/9  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Over Voltage protection (24V)  
The Power Supply is protected by Over voltage in the event that power supply feedback circuit fails  
the output voltage will not be > 32V, +10% under any Line/Load and operating ambient conditions.  
The unique feature about this over voltage protection (OVP) is that power supply doesn’t shut down  
but goes Hicc-up mode (Auto recovery) which is 32V, +/-10%. The power supply output voltage will  
recover back to 24Vdc once the fault condition is removed.  
Over Voltage protection (12Vsb)  
The Power Supply is protected by Over voltage in the event that power supply feedback circuit fails  
the output voltage will not be > 16V +10% under any Line/Load and operating ambient conditions.  
The unique feature about this over voltage protection (OVP) is that power supply doesn’t shut down  
but goes Hicc-up mode (Auto recovery) which is 16V +10%, -5%. The power supply output voltage  
will recover back to 12Vdc once the fault condition is removed.  
10/10  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Inrush Current, Start Up Time, Output Hold Up Time  
Inrush Current,  
Inrush current is the first surge current seen on the input side when AC input is applied to the power  
supply. It is the first pulse captured; see a typical picture for the Inrush current as seen in the power  
supply.  
Start Up Time,  
Start up time is measured from the point AC input is applied and the o/p voltage reaches within  
90% of its set value. See picture below for a typical start up time characteristic of a power supply.  
Rise Time,  
Rise time is the time needed for o/p voltage to rise from 10% of its set value to 90% of its set  
value. See the picture below for a typical rise time measurement in a power supply.  
Hold Up Time,  
Hold time is the time when the AC input collapses and o/p voltage retains regulation for a certain  
period of time is called as hold up time. See in the picture below a typical hold up time  
characteristic of a power supply. The hold time is measured until the o/p voltage remains in  
regulation hence it measured until the o/p voltage reaches 95% of its set value.  
Output Voltage Adjust  
The 24VDC connection is made using the "+" and "" screw connections. At the time of delivery,  
the output voltage is 24VDC. The output voltage can be set from 22 to 28VDC on the  
potentiometer seen as Adjust on the front panel of each power supply.  
11/11  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Dynamic Load  
Additionally power supply is capable of dynamic change of load from 0% to 100% with o/p voltage  
within +5% of regulation limits. See below the dynamic behavior of the PSU.  
Redundancy & Parallel Operation with Oring Diode  
See below figure for a typical Redundant/Parallel operation of PSU using CliQ series power supplies.  
The 2 power supplies PSU1 & PSU 2 are connected thru a twin diode where Anode1 A1 is connected  
to the +Ve i.e. 24V of PSU1 and Anode2 A2 is connected to the +Ve i.e. 24V of PSU2 and the output  
ground GND are shorted together.  
The output of these 2 power supplies PSU1 & PSU2 is drawn from the Cathode K of the twin diode  
thus making the power supply work in Redundant/Parallel operation.  
Redundant Operation:  
When 2 power supplies are connected in below manner the power supply PSU1 or PSU2 whichever  
has higher output voltage takes the max load and the other PSU is operating in standby (@No Load)  
in case of failure on PSU1, PSU2 takes over the load from PSU1 and supplies the required power to  
end system.  
12/12  
Rev: 01,  
3/21/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Redundant / Parallel Operation with External Oring Diode  
13/13  
3/21/2011  
Rev: 01,  
Panel Mount Power Supply  
Technical Information  
PMC-24V300W1BA  
Parallel Operation:  
When 2 power supplies are also connected in the above manner they can share the Load provided  
following steps are taken.  
Step 1:  
Measure the o/p voltages @ NL measured from A1 to Gnd i.e. VA1 to Gnd of PSU1 and VA2 to Gnd  
of PSU2. If the voltages are not same follow step 2, if the o/p voltages are same skip step 2 and  
move to step 3.  
Step 2:  
Adjust the o/p voltages with the help of VR available on the front panel of the PSU marked as  
ADJUST for both PSU1 and PSU2 at the same level for e.g. if PSU1 o/p is measuring 24.15Vdc and  
PSU2 is measuring 24.25Vdc adjust the o/p voltage of either PSU1 close to 24.25Vdc or adjust the  
o/p voltage of PSU2 close to 24.15Vdc.  
Step 3:  
Connect the PSU to the end system load and measure the o/p voltages from A1 to Gnd i.e. VA1 to  
Gnd of PSU1 and VA2 to Gnd of PSU2. Ensure that o/p voltages are same even after the 2 power  
supplies are connected to load. If not then adjust them with the VR available on Front panel. A  
tolerance of + 25mV would be acceptable.  
Note:  
1. If the o/p voltage of any 1 power supply i.e. PSU1 or PSU2 is higher that power supply will take  
the initial load and also share the maximum load.  
2. If the o/p voltages adjusted are same then an equal load current sharing between the 2 power  
supplies can be achieved.  
3. The Oring diode must be of an appropriate rating, recommended rating of Oring Diode is  
minimum 4 times of the output load current and minimum reverse voltage rating of 45Vrr.  
4. A suitable HS is also advised to ensure that oring Diode is not over heated and damaged.  
14/14  
Rev: 01,  
3/21/2011  

相关型号:

PMC24V150W3AA

24V 150W 1 Phase
DELTA

PMC24V150W3BA

24V 300W 1 Phase
DELTA

PMC271

Field Programmable Processor Array
PADAUK

PMC271-D08

Field Programmable Processor Array
PADAUK

PMC271-D14

Field Programmable Processor Array
PADAUK

PMC271-D16

Field Programmable Processor Array
PADAUK

PMC271-D20

Field Programmable Processor Array
PADAUK

PMC271-S08

Field Programmable Processor Array
PADAUK

PMC271-S14

Field Programmable Processor Array
PADAUK

PMC271-S16

Field Programmable Processor Array
PADAUK

PMC271-S18

Field Programmable Processor Array
PADAUK

PMC271-S20

Field Programmable Processor Array
PADAUK