V36SE3R315PNFA [DELTA]

Delphi Series V36SE, 1/16th Brick DC/DC Power Modules: 18~75Vin, 3.3Vo, 50W; 德尔福系列V36SE , 1 / 16号砖DC / DC电源模块: 18 〜 75Vin , 3.3Vo , 50W
V36SE3R315PNFA
型号: V36SE3R315PNFA
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

Delphi Series V36SE, 1/16th Brick DC/DC Power Modules: 18~75Vin, 3.3Vo, 50W
德尔福系列V36SE , 1 / 16号砖DC / DC电源模块: 18 〜 75Vin , 3.3Vo , 50W

电源电路
文件: 总13页 (文件大小:725K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
High efficiency: 90.5% @ 3.3V/15A, 48Vin  
88.5% @ 3.3V/12A, 24Vin  
Size: 33.0x22.8x9.3mm (1.30x0.90”x0.37)  
Industry standard 1/16th brick size & pinout  
Input UVLO  
OTP and output OCP, OVP (default is  
auto-recovery)  
Output voltage trim: -20%, +10%  
Monotonic startup into normal and pre-biased  
loads  
2250V isolation and basic insulation  
No minimum load required  
SMD and Through-hole versions  
ISO 9001, TL 9000, ISO 14001, QS 9000,  
OHSAS 18001 certified manufacturing facility  
UL/cUL 60950-1 (US & Canada) Recognized  
Delphi Series V36SE, 1/16th Brick DC/DC  
Power Modules: 18~75Vin, 3.3Vo, 50W  
OPTIONS  
SMD pins  
The Delphi Series V36SE, 1/16th Brick, 18~75V wide input, single  
output, isolated DC/DC converter, is the latest offering from a world  
leader in power systems technology and manufacturing ― Delta  
Electronics, Inc. This product family provides up to 50 watts of power  
in the industry standard 1/16th brick form factor (1.30”x0.90”) and  
pinout. With creative design technology and optimization of component  
placement, these converters possess outstanding electrical and  
thermal performance, as well as extremely high reliability under highly  
stressful operating conditions. For the 3.3V output module, it delivers  
50W (15A) output with 36 to 75V input and delivers 40W (12A) output  
while the input is 18 to 36V to the same module. Typical efficiency of  
the 3.3V/15A module is greater than 90.5%. All modules are protected  
from abnormal input/output voltage, current, and temperature  
conditions. For lower power needs, but in a similar small form factor,  
please check out Delta S48SP (36W or 10A) and S36SE (17W or 5A)  
series standard DC/DC modules.  
Positive remote On/Off  
APPLICATIONS  
Optical Transport  
Data Networking  
Communications  
Servers  
DS_V36SE3R315_10252013  
TECHNICAL SPECIFICATIONS  
(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)  
PARAMETER  
NOTES and CONDITIONS  
V36SE3R315 (Standard)  
Min.  
Typ.  
Max.  
Units  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Continuous  
Transient (100ms)  
Operating Temperature  
Storage Temperature  
Vdc  
Vdc  
Vdc  
°C  
°C  
Vdc  
0
0
-40  
-55  
80  
100  
118  
125  
2250  
100ms  
Refer to figure 19 for measuring point  
Input/Output Isolation Voltage  
INPUT CHARACTERISTICS  
Operating Input Voltage  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Hysteresis Voltage  
Maximum Input Current  
No-Load Input Current  
Off Converter Input Current  
Inrush Current (I2t)  
Input Reflected-Ripple Current  
Input Voltage Ripple Rejection  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Load  
18  
48  
75  
Vdc  
16  
15  
0.5  
17  
16  
1
18  
17  
1.8  
3.9  
Vdc  
Vdc  
Vdc  
A
mA  
mA  
A2s  
mA  
dB  
100% Load, 18Vin  
30  
8
1
P-P thru 12µH inductor, 5Hz to 20MHz  
120 Hz  
10  
50  
Vin=48V, Io=Io.max, Tc=25°C  
3.267  
3.20  
3.300  
3.333  
Vdc  
Io=Io, min to Io, max  
Vin=36V to 75V  
Tc=-40°C to 85°C  
±3  
±3  
±33  
3.30  
±10  
±10  
mV  
mV  
mV  
V
Over Line  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
Over sample load, line and temperature  
5Hz to 20MHz bandwidth  
Full Load, 1µF ceramic, 100µF tantalum  
Full Load, 1µF ceramic, 100µF tantalum  
Vin = 18V-36V  
3.40  
60  
10  
mV  
mV  
A
RMS  
Operating Output Current Range  
0
0
12  
15  
Vin = 36V-75V  
A
Output Over Current Protection  
DYNAMIC CHARACTERISTICS  
Output Voltage Current Transient  
Positive Step Change in Output Current  
Negative Step Change in Output Current  
Settling Time (within 1% Vout nominal)  
Turn-On Transient  
Output Voltage 10% Low  
110  
140  
%
48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs  
25% Io.max to 50% Io.max  
100  
100  
200  
mV  
mV  
µs  
50% Io.max to 25% Io.max  
Start-Up Time, From On/Off Control  
Start-Up Time, From Input  
Maximum Output Capacitance (note1)  
EFFICIENCY  
100% Load  
100% Load  
60% Load  
ISOLATION CHARACTERISTICS  
Input to Output  
Isolation Resistance  
Isolation Capacitance  
30  
30  
ms  
ms  
µF  
Full load; 5% overshoot of Vout at startup  
10000  
2250  
Vin = 48V  
Vin = 24V  
Vin = 48V  
90.5  
88.5  
90.0  
%
%
%
Vdc  
MΩ  
pF  
10  
1000  
580  
FEATURE CHARACTERISTICS  
Switching Frequency  
KHz  
ON/OFF Control, Negative Remote On/Off logic  
Logic Low (Module On)  
Logic High (Module Off)  
ON/OFF Control, Positive Remote On/Off logic  
Logic Low (Module Off)  
Von/off  
Von/off  
0.8  
18  
V
V
2.4  
2.4  
Von/off  
Von/off  
0.8  
18  
1
V
V
mA  
Logic High (Module On)  
ON/OFF Current (for both remote on/off logic)  
Leakage Current (for both remote on/off logic)  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
GENERAL SPECIFICATIONS  
MTBF  
Ion/off at Von/off=0.0V  
Logic High, Von/off=15V  
Pout max rated power,Io Io.max  
Pout max rated power,Io Io.max  
Over full temp range; % of nominal Vout  
-20  
10  
10  
140  
%
%
%
115  
Io=80% of Io, max; Ta=25°C, airflow rate=300FLM  
Refer to figure 19 for measuring point  
5.8  
12.1  
128  
M hours  
grams  
°C  
Weight  
Over-Temperature Shutdown  
Note1: For applications with higher output capacitive load, please contact Delta  
V36SE3R315_10252013  
2
ELECTRICAL CHARACTERISTICS CURVES  
91  
88  
7
6
5
4
3
2
1
0
85  
24Vin  
18Vin  
48Vin  
82  
79  
18Vin  
75Vin  
76  
24Vin  
48Vin  
60  
75Vin  
40  
73  
70  
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
10  
20  
30  
50  
70  
80  
90  
100  
OUTPUT CURRENT(A%)  
OUTPUT CURRENT(A%)  
Figure 1: Efficiency vs. load current for minimum, nominal, and  
maximum input voltage at 25°C  
Figure 2: Power dissipation vs. load current for minimum,  
nominal, and maximum input voltage at 25°C  
18V~36Vin, Io,max is 12A, 36V~75Vin, Io,max is 15A  
18V~36Vin, Io,max is 12A, 36V~75Vin, Io,max is 15A  
3
2.7  
2.4  
2.1  
1.8  
1.5  
1.2  
0.9  
0.6  
0.3  
0
15 20 25 30 35 40 45 50 55 60 65 70 75  
INPUT VOLTAGE(V)  
Figure 3: Typical full load input characteristics at room  
temperature  
V36SE3R315_10252013  
3
ELECTRICAL CHARACTERISTICS CURVES  
For Negative Remote On/Off Logic  
Figure 4: Turn-on transient at full rated load current (resistive  
load) (10 ms/div). Vin=48V. Top Trace: Vout, 1.0V/div; Bottom  
Trace: ON/OFF input, 2V/div  
Figure 5: Turn-on transient at zero load current (10 ms/div).  
Vin=48V. Top Trace: Vout: 1.0V/div, Bottom Trace: ON/OFF  
input, 2V/div  
Figure 6: Output voltage response to step-change in load  
current (50%-25%-50% of Io, max; di/dt = 0.1A/µs; Vin is 24v).  
Load cap: 10µF tantalum capacitor and 1µF ceramic capacitor.  
Top Trace: Vout (50mV/div, 200us/div), Bottom Trace: Iout  
(5A/div). Scope measurement should be made using a BNC  
cable (length shorter than 20 inches). Position the load  
between 51 mm to 76 mm (2 inches to 3 inches) from the  
module.  
Figure 7: Output voltage response to step-change in load  
current (50%-25%-50% of Io, max; di/dt = 0.1A/µs; Vin is 48v).  
Load cap: 10µF tantalum capacitor and 1µF ceramic capacitor.  
Top Trace: Vout (50mV/div, 200us/div), Bottom Trace: Iout  
(5A/div). Scope measurement should be made using a BNC  
cable (length shorter than 20 inches). Position the load  
between 51 mm to 76 mm (2 inches to 3 inches) from the  
module.  
V36SE3R315_10252013  
4
ELECTRICAL CHARACTERISTICS CURVES  
Figure 8: Test set-up diagram showing measurement points for  
Input Terminal Ripple Current and Input Reflected Ripple  
Current.  
Note: Measured input reflected-ripple current with a simulated  
source Inductance (LTEST) of 12 μH. Capacitor Cs offset  
possible battery impedance. Measure current as shown above  
Figure 9: Input Terminal Ripple Current, ic, at full rated output  
current and nominal input voltage (Vin=48v) with 12µH source  
impedance and 33µF electrolytic capacitor (200 mA/div,  
1us/div)  
Copper Strip  
Vo(+)  
SCOPE  
RESISTIVE  
LOAD  
10u  
1u  
Vo(-)  
Figure 10: Input reflected ripple current, is, through a 12µH  
source inductor at nominal input voltage (vin=48v) and rated  
load current (20 mA/div, 1us/div)  
Figure 11: Output voltage noise and ripple measurement test  
setup  
3.5  
3
2.5  
2
1.5  
1
0.5  
0
0
2
4
6
8
10  
12  
14  
16  
18  
20  
LOAD CURRENT (A)  
Figure 12: Output voltage ripple at nominal input voltage  
(vin=48v) and rated load current (Io=15A) (50 mV/div,  
1us/div).Load capacitance: 1µF ceramic capacitor and 100µF  
tantalum capacitor. Bandwidth: 20 MHz. Scope measurements  
should be made using a BNC cable (length shorter than 20  
inches). Position the load between 51 mm to 76 mm (2 inches  
to 3 inches) from the module  
Figure 13: Output voltage vs. load current showing typical  
current limit curves and converter shutdown points (Vin=48v)  
V36SE3R315_10252013  
5
DESIGN CONSIDERATIONS  
Input Source Impedance  
The input source must be insulated from the ac  
mains by reinforced or double insulation.  
The impedance of the input source connecting to the  
DC/DC power modules will interact with the modules and  
affect the stability. A low ac-impedance input source is  
recommended. If the source inductance is more than a  
few μH, we advise adding a 10 to 100 μF electrolytic  
capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the  
input of the module to improve the stability.  
The input terminals of the module are not operator  
accessible.  
If the metal baseplate / heatspreader is grounded  
the output must be also grounded, one Vi pin and  
one Vo pin shall also be grounded.  
Layout and EMC Considerations  
A SELV reliability test is conducted on the system  
where the module is used, in combination with the  
module, to ensure that under a single fault,  
hazardous voltage does not appear at the module’s  
output.  
Delta’s DC/DC power modules are designed to operate in  
a wide variety of systems and applications. For design  
assistance with EMC compliance and related PWB layout  
issues, please contact Delta’s technical support team. An  
external input filter module is available for easier EMC  
compliance design. Customers could refer to the Delta  
Filter Module datasheets (for example, FL75L07A) for  
application needs or contact Delta’s technical support  
team.  
When installed into a Class II equipment (without  
grounding), spacing consideration should be given to  
the end-use installation, as the spacing between the  
module and mounting surface have not been evaluated.  
Safety Considerations  
The power module has extra-low voltage (ELV) outputs  
when all inputs are ELV.  
The power module must be installed in compliance with  
the spacing and separation requirements of the  
end-user’s safety agency standard, i.e., UL60950-1,  
CAN/CSA-C22.2, No. 60950-1 and EN60950-1+A11 and  
IEC60950-1, if the system in which the power module is to  
be used must meet safety agency requirements.  
This power module is not internally fused. To achieve  
optimum safety and system protection, an input line fuse  
is highly recommended. The safety agencies require a  
normal-blow fuse with 5A maximum rating to be installed  
in the ungrounded lead. A lower rated fuse can be used  
based on the maximum inrush transient energy and  
maximum input current.  
Basic insulation based on 75 Vdc input is provided  
between the input and output of the module for the  
purpose of applying insulation requirements when the  
input to this DC-to-DC converter is identified as TNV-2 or  
SELV. An additional evaluation is needed if the source  
is other than TNV-2 or SELV.  
Soldering and Cleaning Considerations  
Post solder cleaning is usually the final board assembly  
process before the board or system undergoes electrical  
testing. Inadequate cleaning and/or drying may lower the  
reliability of a power module and severely affect the  
finished circuit board assembly test. Adequate cleaning  
and/or drying is especially important for un-encapsulated  
and/or open frame type power modules. For assistance  
on appropriate soldering and cleaning procedures,  
please contact Delta’s technical support team.  
When the input source is SELV circuit, the power module  
meets SELV (safety extra-low voltage) requirements. If the  
input source is a hazardous voltage which is greater than  
60 Vdc and less than or equal to 75 Vdc, for the module’s  
output to meet SELV requirements, all of the following  
must be met:  
V36SE3R315_10252013  
6
Remote On/Off  
FEATURES DESCRIPTIONS  
The remote on/off feature on the module can be either  
negative or positive logic. Negative logic turns the  
module on during a logic low and off during a logic high.  
Positive logic turns the modules on during a logic high  
and off during a logic low.  
Over-Current Protection  
The modules include an internal output over-current  
protection circuit, which will endure current limiting for an  
unlimited duration during output overload. If the output  
current exceeds the OCP set point, the modules will  
automatically shut down, and enter hiccup mode or latch  
mode, which is optional.  
Remote on/off can be controlled by an external switch  
between the on/off terminal and the Vi(-) terminal. The  
switch can be an open collector or open drain.  
For hiccup mode, the module will try to restart after  
shutdown. If the over current condition still exists, the  
module will shut down again. This restart trial will continue  
until the over-current condition is corrected.  
For negative logic if the remote on/off feature is not  
used, please short the on/off pin to Vi(-). For positive  
logic if the remote on/off feature is not used, please  
leave the on/off pin floating.  
For latch mode, the module will latch off once it shutdown.  
The latch is reset by either cycling the input power or by  
toggling the on/off signal for one second.  
Vi(+)  
Vo(+)  
Sense(+)  
ON/OFF  
Over-Voltage Protection  
trim  
Rload  
The modules include an internal output over-voltage  
protection circuit, which monitors the voltage on the output  
terminals. If this voltage exceeds the over-voltage set point,  
the module will shut down, and enter in hiccup mode or  
latch mode, which is optional.  
Sense(-)  
Vo(-)  
Vi(-)  
Figure 14: Remote on/off implementation  
For hiccup mode, the module will try to restart after  
shutdown. If the over voltage condition still exists, the  
module will shut down again. This restart trial will continue  
until the over-voltage condition is corrected.  
Remote Sense  
Remote sense compensates for voltage drops on the  
output by sensing the actual output voltage at the point  
of load. The voltage between the remote sense pins  
and the output terminals must not exceed the output  
voltage sense range given here:  
For latch mode, the module will latch off once it shutdown.  
The latch is reset by either cycling the input power or by  
toggling the on/off signal for one second.  
[Vo(+) Vo()] [SENSE(+) SENSE(–)] ≤ 10% ×  
Vout  
Over-Temperature Protection  
The over-temperature protection consists of circuitry that  
provides protection from thermal damage. If the  
temperature exceeds the over-temperature threshold the  
module will shut down, and enter in hiccup mode or latch  
mode, which is optional.  
This limit includes any increase in voltage due to  
remote sense compensation and output voltage set  
point adjustment (trim).  
Conduct resistance  
Vi(+)  
Vo(+)  
For hiccup mode, the module will try to restart after  
shutdown. If the over temperature condition still exists, the  
module will shut down again. This restart trial will continue  
until the over-temperature condition is corrected.  
Sense(+)  
ON/OFF  
trim  
Rload  
Sense(-)  
Vo(-)  
For latch mode, the module will latch off once it shutdown.  
The latch is reset by either cycling the input power or by  
toggling the on/off signal for one second.  
Vi(-)  
Figure 15: Effective circuit configuration for remote sense  
operation  
V36SE3R315_10252013  
7
FEATURES DESCRIPTIONS (CON.)  
If the remote sense feature is not used to regulate the output  
at the point of load, please connect SENSE(+) to Vo(+) and  
SENSE() to Vo() at the module.  
The output voltage can be increased by both the remote  
sense and the trim; however, the maximum increase is the  
larger of either the remote sense or the trim, not the sum of  
both.  
When using remote sense and trim, the output voltage  
of the module is usually increased, which increases the  
power output of the module with the same output  
current.  
Care should be taken to ensure that the maximum  
output power does not exceed the maximum rated  
power.  
Figure 17: Circuit configuration for trim-up (increase output  
voltage)  
If the external resistor is connected between the TRIM  
and SENSE (+) the output voltage set point increases  
(Fig. 19). The external resistor value required to obtain  
a percentage output voltage change % is defined  
as:  
Output Voltage Adjustment (TRIM)  
To increase or decrease the output voltage set point,  
connect an external resistor between the TRIM pin and  
either the SENSE(+) or SENSE(-). The TRIM pin  
should be left open if this feature is not used.  
5.11Vo (100  ) 511  
Rtrim up   
10.22  
K  
1.24  
Ex. When Trim-up +10% (3.3V×1.1=3.63V)  
5.113.3(10010) 511  
Rtrim up   
10.22 88.27  
K  
1.2410  
10  
The output voltage can be increased by both the remote  
sense and the trim, however the maximum increase is  
the larger of either the remote sense or the trim, not the  
sum of both.  
When using remote sense and trim, the output voltage  
of the module is usually increased, which increases the  
power output of the module with the same output  
current.  
Figure 16: Circuit configuration for trim-down (decrease  
output voltage)  
If the external resistor is connected between the TRIM  
and SENSE (-) pins, the output voltage set point  
decreases (Fig. 18). The external resistor value  
required to obtain a percentage of output voltage  
change % is defined as:  
Care should be taken to ensure that the maximum  
output power of the module remains at or below the  
maximum rated power.  
511  
Rtrim down   
10.22  
K  
Ex. When Trim-down -20% (3.30V×0.8=2.64V)  
511  
20  
Rtrim down   
10.22  
K  
15.33  
K  
V36SE3R315_10252013  
8
THERMAL CURVES  
THERMAL CONSIDERATIONS  
Thermal management is an important part of the system  
design. To ensure proper, reliable operation, sufficient  
cooling of the power module is needed over the entire  
temperature range of the module. Convection cooling is  
usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
Thermal Testing Setup  
Delta’s DC/DC power modules are characterized in  
heated vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
Figure 19: Temperature measurement location  
* The allowed maximum hot spot temperature is defined at 118.  
V36SE3R315 (standard) Output Current vs. Ambient Temperature and Air Velocity  
Output Current (A)  
@Vin=24V (Either Orientation)  
12  
The following figure shows the wind tunnel  
characterization setup. The power module is mounted  
on a test PWB and is vertically positioned within the  
wind tunnel. The space between the neighboring PWB  
and the top of the power module is constantly kept at  
6.35mm (0.25’’).  
Natural  
Convection  
10  
8
100LFM  
200LFM  
6
4
PWB  
MODULE  
FACING PWB  
2
0
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 20: Output current vs. ambient temperature and air velocity  
@ Vin=24V (Either Orientation)  
V36SE3R315 (standard) Output Current vs. Ambient Temperature and Air Velocity  
Output Current (A)  
@Vin=48V (Either Orientation)  
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
MEASURED BELOW  
THE MODULE  
15  
50.8 (2.0”)  
Natural  
Convection  
12  
AIR FLOW  
100LFM  
9
6
3
0
200LFM  
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)  
Figure 18: Wind tunnel test setup  
Thermal Derating  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Heat can be removed by increasing airflow over the  
module. To enhance system reliability, the power  
module should always be operated below the maximum  
operating temperature. If the temperature exceeds the  
maximum module temperature, reliability of the unit may  
be affected.  
Figure 21: Output current vs. ambient temperature and air velocity  
@ Vin=48V (Either Orientation)  
V36SE3R315_10252013  
9
PICK AND PLACE LOCATION  
RECOMMENDED PAD LAYOUT (SMD)  
SURFACE-MOUNT TAPE & REEL  
V36SE3R315_10252013  
10  
LEADED (Sn/Pb) PROCESS RECOMMENDED TEMPERATURE PROFILE  
Note: The temperature refers to the pin of V36SE, measured on the pin +Vout joint.  
LEAD FREE (SAC) PROCESS RECOMMENDED TEMPERATURE PROFILE  
Temp.  
Peak Temp. 240 ~ 245  
217  
200℃  
Ramp down  
max. 4/sec.  
Preheat time  
100~140 sec.  
150℃  
25℃  
Time Limited 90 sec.  
above 217℃  
Ramp up  
max. 3/sec.  
Time  
Note: The temperature refers to the pin of V36SE, measured on the pin +Vout joint.  
V36SE3R315_10252013  
11  
MECHANICAL DRAWING  
Surface-mount module  
Through-hole module  
Pin No.  
Name  
Function  
1
2
3
4
5
6
7
8
+Vin  
ON/OFF  
-Vin  
-Vout  
-SENSE  
TRIM  
Positive input voltage  
Remote ON/OFF  
Negative input voltage  
Negative output voltage  
Negative remote sense  
Output voltage trim  
+SENSE  
+Vout  
Positive remote sense  
Positive output voltage  
V36SE3R315_10252013  
12  
PART NUMBERING SYSTEM  
V
36  
S
E
3R3  
15  
N
R
F
A
Type of  
Product Voltage Outputs  
V - 1/16  
Brick  
Input  
Number of Product  
Series  
Output  
Voltage  
Output  
Current Logic  
ON/OFF  
Pin  
Length/Type  
N- Negative M - SMD  
Option Code  
36 -  
18V~75V  
S - Single  
E - Regular 3R3 - 3.3V 15 - 15A  
A - Standard  
Functions  
Space - RoHS 5/6  
P- Positive N - 0.145"  
R - 0.170”  
F - RoHS 6/6  
(Lead Free)  
K 0.110”  
MODEL LIST  
MODEL NAME  
V36SE3R315NRFA  
V36SE3R315NMFA  
V36SE3R315NNFA  
INPUT  
OUTPUT  
EFF @ 100% LOAD  
18V~75V  
18V~75V  
18V~75V  
3.9A  
3.9A  
3.9A  
3.3V  
3.3V  
3.3V  
12A (18~36Vin) & 15A (36~75Vin) 88.5% @ 24Vin, 90.5% @ 48Vin  
12A (18~36Vin) & 15A (36~75Vin) 88.5% @ 24Vin, 90.5% @ 48Vin  
12A (18~36Vin) & 15A (36~75Vin) 88.5% @ 24Vin, 90.5% @ 48Vin  
Default remote on/off logic is negative and pin length is 0.170”  
CONTACT: www.deltaww.com/dcdc  
USA:  
Telephone:  
East Coast: 978-656-3993  
West Coast: 510-668-5100  
Fax: (978) 656 3964  
Email: DCDC@delta-corp.com  
Asia & the rest of world:  
Telephone: +886 3 4526107  
Ext 6220~6224  
Fax: +886 3 4513485  
Email: DCDC@delta.com.tw  
Europe:  
Phone: +31-20-655-0967  
Fax: +31-20-655-0999  
Email: DCDC@delta-es.com  
WARRANTY  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon  
request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its  
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted  
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications  
at any time, without notice.  
V36SE3R315_10252013  
13  

相关型号:

V36SE3R315PRFA

Delphi Series V36SE, 1/16th Brick DC/DC Power Modules: 18~75Vin, 3.3Vo, 50W
DELTA

V36ZA20P

Radial Lead Varistors
LITTELFUSE

V36ZA80

Radial Lead Metal-Oxide Varistors for Low to Medium Voltage Operation
HARRIS

V36ZA80

Varistor Products - Low to Medum Voltage, Radial Lead
LITTELFUSE

V36ZA80P

Varistor Products - Low to Medum Voltage, Radial Lead
LITTELFUSE

V36ZA80PX10

VARISTOR 36V 2KA DISC 20MM
LITTELFUSE

V36ZA80PX1347

VARISTOR 36V 2KA DISC 20MM
LITTELFUSE

V36ZA80PX2855

VARISTOR 36V 2KA DISC 20MM
LITTELFUSE

V36ZA80X10

RESISTOR, VOLTAGE DEPENDENT, 31V, 160J, THROUGH HOLE MOUNT
RENESAS

V36ZA80X1347

RESISTOR, VOLTAGE DEPENDENT, 31V, 160J, THROUGH HOLE MOUNT, RADIAL LEADED
LITTELFUSE

V36ZC80

RESISTOR, VOLTAGE DEPENDENT, 31V, 160J, THROUGH HOLE MOUNT
RENESAS

V36ZC80

RESISTOR, VOLTAGE DEPENDENT, 31V, 160J, THROUGH HOLE MOUNT, RADIAL LEADED
LITTELFUSE