V48SC12007PMFA [DELTA]

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out; 德尔福系列V48SC , 1 / 16号砖90W DC / DC电源模块: , 12V , 7.5A 48V出来
V48SC12007PMFA
型号: V48SC12007PMFA
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out
德尔福系列V48SC , 1 / 16号砖90W DC / DC电源模块: , 12V , 7.5A 48V出来

电源电路
文件: 总13页 (文件大小:793K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FEATURES  
High efficiency: 92.0% @ 12V/7.5A  
Size: 33.0x22.8x9.5mm  
(1.30”x0.90”x0.37)  
Industry standard footprint and pinout  
Fixed frequency operation  
SMD or through-hole versions  
Input UVLO  
OTP and output OCP, OVP  
Output voltage trim: -20%, +10%  
Monotonic startup into normal and  
pre-biased loads  
1500V isolation and basic insulation  
No minimum load required  
No negative current during power or  
enable on/off  
ISO 9001, TL 9000, ISO 14001, QS 9000,  
OHSAS18001 certified manufacturing  
facility  
UL/cUL 60950-1 (US & Canada)  
Recognized  
Delphi Series V48SC, 1/16th Brick 90W  
DC/DC Power Modules: 48V in, 12V, 7.5A out  
The Delphi Series V48SC, 1/16th Brick, 48V input, single output,  
isolated DC/DC converters, are the latest offering from a world leader  
in power systems technology and manufacturing ― Delta Electronics,  
Inc. This product family provides up to 90 watts of power or 30A of  
output current in the 1/16th brick form factor (1.3”x0.90”) and pinout.  
With creative design technology and optimization of component  
placement, these converters possess outstanding electrical and  
thermal performance, as well as extremely high reliability under highly  
stressful operating conditions. Typical efficiency of the 12V/7.5A  
module is greater than 92.0%. All modules are protected from  
abnormal input/output voltage, current, and temperature conditions.  
For lower power needs, but in a similar small form factor, please check  
out Delta V36SE (50W), S48SP (36W or 10A) and S36SE (17W or 5A)  
series standard DC/DC modules.  
OPTIONS  
SMD pins  
Short pin lengths available  
Positive remote On/Off  
Heat spreader  
APPLICATIONS  
Optical Transport  
Data Networking  
Communications  
Servers  
DS_V48SC12007_08212013  
TECHNICAL SPECIFICATIONS  
(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)  
PARAMETER  
NOTES and CONDITIONS  
V48SC12007 (Standard)  
Min.  
Typ.  
Max.  
Units  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Continuous  
Transient (100ms)  
Operating Ambient Temperature  
Storage Temperature  
Input/Output Isolation Voltage  
INPUT CHARACTERISTICS  
Operating Input Voltage  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Hysteresis Voltage  
Maximum Input Current  
No-Load Input Current  
80  
100  
85  
125  
1500  
Vdc  
Vdc  
°C  
°C  
Vdc  
100ms  
-40  
-55  
36  
48  
75  
Vdc  
32.5  
29.5  
1.5  
34.5  
31.5  
3
35.5  
33.5  
4
Vdc  
Vdc  
Vdc  
A
mA  
mA  
A2s  
100% Load, 36Vin  
4
60  
8
Off Converter Input Current  
Inrush Current (I2t)  
12  
1
With 100uF external input capacitor  
Input Reflected-Ripple Current  
Input Voltage Ripple Rejection  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Load  
Over Line  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
P-P thru 12µH inductor, 5Hz to 20MHz  
120 Hz  
20  
mA  
dB  
-60  
12  
Vin=48V, Io=Io.max, Tc=25°C  
11.82  
11.64  
12.18  
12.36  
Vdc  
Io=Io, min to Io, max  
Vin=36V to 75V  
Tc=-40°C to125°C  
±5  
±5  
±180  
mV  
mV  
mV  
V
Over sample load, line and temperature  
5Hz to 20MHz bandwidth  
max load on output, 20MHz bandwidth  
10uF tantalum + 1uF ceramic capacitor  
max load on output, 20MHz bandwidth  
10uF tantalum + 1uF ceramic capacitor  
Peak-to-Peak  
RMS  
100  
30  
mV  
mV  
Operating Output Current Range  
Output Over Current Protection  
DYNAMIC CHARACTERISTICS  
0
110  
7.5  
140  
A
%
Output Voltage 10% Low  
load capacitor10uF tantalum + 1u ceramic 0.1A/uS  
Frequency= 250Hz  
Output Voltage Current Transient  
Positive Step Change in Output Current  
Negative Step Change in Output Current  
Settling Time (within 1% Vout nominal)  
Turn-On Transient  
50% Io.max to 75% Io.max  
75% Io.max to 50% Io.max  
300  
300  
200  
mV  
mV  
us  
Start-Up Delay Time, From On/Off Control or Input  
Start-Up Rise Time, From On/Off Control or Input  
Maximum Output Capacitance  
EFFICIENCY  
From On/Off Control or Input to 10%Vo  
From 10%Vo to 90% Vo  
Full load; 5% overshoot of Vout at startup;  
15  
40  
3300  
ms  
ms  
µF  
0
100% Load  
60% Load  
Vin=48V  
Vin=48V  
92.0  
92.0  
%
%
ISOLATION CHARACTERISTICS  
Input to Output  
Isolation Resistance  
Isolation Capacitance  
FEATURE CHARACTERISTICS  
Switching Frequency  
1500  
Vdc  
MΩ  
pF  
10  
1000  
420  
kHz  
ON/OFF Control, Negative Remote On/Off logic  
Logic Low (Module On)  
Von/off  
Von/off  
0
2.4  
0.7  
5
V
V
Logic High (Module Off)  
ON/OFF Control, Positive Remote On/Off logic  
Logic Low (Module Off)  
Von/off  
Von/off  
0
2.4  
0.7  
5
V
V
Logic High (Module On)  
ON/OFF Current (for both remote on/off logic)  
Ion/off at Von/off=0.0V  
1
mA  
ON/OFF Current (for both remote on/off logic)  
Leakage Current (for both remote on/off logic)  
Output Voltage Trim Range  
Ion/off at Von/off=2.4V  
Logic High, Von/off=5V  
Max rated current guaranteed at full trim range  
Max rated current guaranteed at full remote sense  
range  
uA  
uA  
%
-20  
10  
10  
Output Voltage Remote Sense Range  
%
%
Output Over-Voltage Protection  
Over full temp range; % of nominal Vout  
110  
140  
GENERAL SPECIFICATIONS  
Per Telecordia SR-332, 80% load, 25°C, 48Vin,  
300LFM  
MTBF  
4.9  
15  
M hours  
grams  
Weight  
Open frame  
Refer to Figure 22 for Hot spot location  
(48Vin,80%Io, 200LFM,Airflow from Vout+ to Vin+)  
Refer to Figure 22 for NTC resistor location  
Over-Temperature Shutdown (Hot Spot)  
127  
120  
132  
125  
137  
130  
°C  
°C  
Over-Temperature Shutdown (NTC Resistor)  
Note: Please attach thermocouple on NTC resistor to test OTP function, the hot spot’s temperature is just for reference.  
2
DS_V48SC12007_08212013  
ELECTRICAL CHARACTERISTICS CURVES  
Figure 1: Efficiency vs. load current for minimum, nominal, and  
maximum input voltage at 25°C  
Figure 2: Power dissipation vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 3: Typical full load input characteristics at room  
temperature  
3
DS_V48SC12007_08212013  
ELECTRICAL CHARACTERISTICS CURVES  
For Negative Remote On/Off Start up  
Figure 4: Turn-on transient at full rated load current (10  
ms/div). Vin=48V. Top Trace: Vout, 5.0V/div; Bottom Trace:  
ON/OFF input, 5V/div  
Figure 5: Turn-on transient at zero load current (10 ms/div).  
Vin=48V. Top Trace: Vout: 5.0V/div, Bottom Trace: ON/OFF  
input, 5V/div  
For Input Voltage Start up  
Figure 6: Turn-on transient at full rated load current (10  
ms/div). Vin=48V. Top Trace: Vout, 5.0V/div; Bottom Trace: Vin,  
50V/div  
Figure 7: Turn-on transient at zero load current (10 ms/div).  
Vin=48V. Top Trace: Vout, 5.0V/div; Bottom Trace: Vin, 50V/div  
Figure 8: Output voltage response to step-change in load  
current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap:  
10µF tantalum capacitor and 1µF ceramic capacitor. Top Trace:  
Vout (0.15V/div, 200us/div), Bottom Trace: Iout (5A/div). Scope  
measurement should be made using a BNC cable (length  
shorter than 20 inches). Position the load between 51 mm to 76  
mm (2 inches to 3 inches) from the module  
4
DS_V48SC12007_08212013  
ELECTRICAL CHARACTERISTICS CURVES  
is  
ic  
Vin+  
Vin-  
+
+
Cs: 220uF  
100uF,  
ESR=0.2 ohm @  
25oC 100KHz  
Figure 9: Test set-up diagram showing measurement points for  
Input Terminal Ripple Current and Input Reflected Ripple  
Current.  
Figure 10: Input Terminal Ripple Current, ic, at full rated output  
current and nominal input voltage with 12µH source impedance  
and 33µF electrolytic capacitor (200 mA/div, 1us/div)  
Note: Measured input reflected-ripple current with a simulated  
source Inductance (LTEST) of 12 μH. Capacitor Cs offset  
possible battery impedance. Measure current as shown above  
Copper Strip  
Vo(+)  
SCOPE  
RESISTIVE  
LOAD  
10u  
1u  
Vo(-)  
Figure 11: Input reflected ripple current, is, through a 12µH  
source inductor at nominal input voltage and rated load current  
(20 mA/div, 2us/div)  
Figure 12: Output voltage noise and ripple measurement test  
setup  
Figure 13: Output voltage ripple at nominal input voltage and  
rated load current (Io=7.5A)(50 mV/div, 1us/div)  
Load capacitance: 1µF ceramic capacitor and 10µF tantalum  
capacitor. Bandwidth: 20 MHz. Scope measurements should be  
made using a BNC cable (length shorter than 20 inches).  
Position the load between 51 mm to 76 mm (2 inches to 3  
inches) from the module.  
5
DS_V48SC12007_08212013  
DESIGN CONSIDERATIONS  
Input Source Impedance  
The impedance of the input source connecting to the  
DC/DC power modules will interact with the modules and  
affect the stability. A low ac-impedance input source is  
recommended. If the source inductance is more than a  
few μH, we advise adding a 100 μF electrolytic capacitor  
(ESR < 0.7 Ω at 100 kHz) mounted close to the input of  
the module to improve the stability.  
Layout and EMC Considerations  
Figure 15 - EMI test negative line  
Delta’s DC/DC power modules are designed to operate in  
a wide variety of systems and applications. For design  
assistance with EMC compliance and related PWB layout  
issues, please contact Delta’s technical support team. An  
external input filter module is available for easier EMC  
compliance design. Below is the reference design for an  
input filter tested with V48SC120XXX to meet EN55022  
(VDE0878) class A(both q. peak and average)  
Schematic and Components List  
Figure 16 - EMI test positive line  
Safety Considerations  
The power module must be installed in compliance with  
the spacing and separation requirements of the  
end-user’s safety agency standard, i.e., UL60950-1,  
CSA C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd :  
2005 and EN 60950-1 2nd: 2006+A11+A1: 2010, if the  
system in which the power module is to be used must  
meet safety agency requirements.  
Figure 14 - EMI test schematic  
C1= 3.3uF/100 V  
C2= 47uF/100 V  
C3= 47uF/100 V  
Basic insulation based on 75 Vdc input is provided  
between the input and output of the module for the  
purpose of applying insulation requirements when the  
input to this DC-to-DC converter is identified as TNV-2  
or SELV. An additional evaluation is needed if the  
source is other than TNV-2 or SELV.  
C4=C5=1nF/250Volt  
T1=1mH, type P53910(Pulse)  
Test Result:  
At T = +25C , Vin = 48 V and full load  
Yellow line is quasi peak mode; Blue line is average mode.  
When the input source is SELV circuit, the power module  
meets SELV (safety extra-low voltage) requirements. If  
the input source is a hazardous voltage which is greater  
than 60 Vdc and less than or equal to 75 Vdc, for the  
module’s output to meet SELV requirements, all of the  
following must be met:  
6
DS_V48SC12007_08212013  
For hiccup mode, the module will try to restart after  
shutdown. If the over voltage condition still exists, the  
module will shut down again. This restart trial will  
continue until the over-voltage condition is corrected.  
The input source must be insulated from the ac mains  
by reinforced or double insulation.  
The input terminals of the module are not operator  
accessible.  
For latch mode, the module will latch off once it  
shutdown. The latch is reset by either cycling the input  
power or by toggling the on/off signal for one second.  
A SELV reliability test is conducted on the system  
where the module is used, in combination with the  
module, to ensure that under a single fault, hazardous  
voltage does not appear at the module’s output.  
Over-Temperature Protection  
The over-temperature protection consists of circuitry that  
provides protection from thermal damage. If the  
temperature exceeds the over-temperature threshold the  
module will shut down, and enter in auto-restart mode or  
latch mode, which is optional, the default is auto-restart  
mode.  
When installed into a Class II equipment (without  
grounding), spacing consideration should be given to the  
end-use installation, as the spacing between the module  
and mounting surface have not been evaluated.  
The power module has extra-low voltage (ELV) outputs  
when all inputs are ELV.  
For auto-restart mode, the module will monitor the  
module temperature after shutdown. Once the  
temperature is dropped and within the specification, the  
module will be auto-restart.  
This power module is not internally fused. To achieve  
optimum safety and system protection, an input line fuse  
is highly recommended. The safety agencies require a  
Fast-acting fuse with 20A maximum rating to be installed  
in the ungrounded lead. A lower rated fuse can be used  
based on the maximum inrush transient energy and  
maximum input current.  
Remote On/Off  
The remote on/off feature on the module can be either  
negative or positive logic. Negative logic turns the  
module on during a logic low and off during a logic high.  
Positive logic turns the modules on during a logic high  
and off during a logic low.  
Soldering and Cleaning Considerations  
Remote on/off can be controlled by an external switch  
between the on/off terminal and the Vi(-) terminal. The  
switch can be an open collector or open drain.  
For negative logic if the remote on/off feature is not used,  
please short the on/off pin to Vi(-). For positive logic if the  
remote on/off feature is not used, please leave the on/off  
pin floating.  
Post solder cleaning is usually the final board assembly  
process before the board or system undergoes electrical  
testing. Inadequate cleaning and/or drying may lower the  
reliability of a power module and severely affect the  
finished circuit board assembly test. Adequate cleaning  
and/or drying is especially important for un-encapsulated  
and/or open frame type power modules. For assistance on  
appropriate soldering and cleaning procedures, please  
contact Delta’s technical support team.  
Vi(+)  
Vo(+)  
Sense(+)  
Over-Current Protection  
ON/OFF  
Vi(-)  
The modules include an internal output over-current  
protection circuit, which will endure current limiting for an  
unlimited duration during output overload. If the output  
current exceeds the OCP set point, the modules will  
automatically shut down, and enter hiccup mode or latch  
mode, which is optional, the default is hiccup mode.  
Sense(-)  
Vo(-)  
Figure 17: Remote on/off implementation  
For hiccup mode, the module will try to restart after  
shutdown. If the over current condition still exists, the  
module will shut down again. This restart trial will continue  
until the over-current condition is corrected.  
Remote Sense  
Remote sense compensates for voltage drops on the  
output by sensing the actual output voltage at the point  
of load. The voltage between the remote sense pins and  
the output terminals must not exceed the output voltage  
sense range given here:  
Over-Voltage Protection  
The modules include an internal output over-voltage  
protection circuit, which monitors the voltage on the  
output terminals. If this voltage exceeds the over-voltage  
set point, the module will shut down, and enter in hiccup  
mode or latch mode, which is optional, the default is  
hiccup mode.  
[Vo(+) Vo()] [SENSE(+) SENSE(–)] ≤ 10% × Vout  
This limit includes any increase in voltage due to remote  
sense compensation and output voltage set point  
adjustment (trim).  
7
DS_V48SC12007_08212013  
FEATURES DESCRIPTIONS (CON.)  
If the external resistor is connected between the TRIM  
and SENSE (-) pins, the output voltage set point  
decreases (Fig. 19). The external resistor value  
required to obtain a percentage of output voltage  
change % is defined as:  
Vi(+) Vo(+)  
Sense(+)  
511  
Rtrim down   
10.22  
K  
Sense(-)  
Vi(-)  
Vo(-)  
Ex. When Trim-down -10% (12V×0.9=10.8V)  
Contact  
Resistance  
Contact and Distribution  
Losses  
511  
10  
Rtrim down   
10.22  
K  
40.88  
K  
Figure 18: Effective circuit configuration for remote sense  
operation  
If the remote sense feature is not used to regulate the  
output at the point of load, please connect SENSE(+) to  
Vo(+) and SENSE() to Vo() at the module.  
The output voltage can be increased by both the  
remote sense and the trim; however, the maximum  
increase is the larger of either the remote sense or the  
trim, not the sum of both.  
When using remote sense and trim, the output voltage  
of the module is usually increased, which increases the  
power output of the module with the same output  
current.  
Figure 20: Circuit configuration for trim-up (increase output  
voltage)  
Max rated current is guaranteed at full output voltage  
remote sense range.  
If the external resistor is connected between the TRIM  
and SENSE (+) the output voltage set point increases  
(Fig. 20). The external resistor value required to obtain  
a percentage output voltage change % is defined  
as:  
Output Voltage Adjustment (TRIM)  
To increase or decrease the output voltage set point,  
connect an external resistor between the TRIM pin and  
either the SENSE(+) or SENSE(-). The TRIM pin  
should be left open if this feature is not used.  
5.11Vo (100  )  
1.225  
511  
Rtrim up   
10.22  
K  
Ex. When Trim-up +10% (12V×1.1=13.2V)  
5.1112(100 10) 511  
Rtrim up   
10.22 489.31  
K  
1.22510  
10  
Trim resistor can also be connected to Vo+ or Vo- but it  
would introduce a small error voltage than the desired  
value.  
The output voltage can be increased by both the remote  
sense and the trim, however the maximum increase is  
the larger of either the remote sense or the trim, not the  
sum of both.  
Figure 19: Circuit configuration for trim-down (decrease  
output voltage)  
8
DS_V48SC12007_08212013  
Thermal Derating  
THERMAL CONSIDERATIONS  
Heat can be removed by increasing airflow over the module.  
To enhance system reliability, the power module should  
always be operated below the maximum operating  
temperature. If the temperature exceeds the maximum  
module temperature, reliability of the unit may be affected.  
Thermal management is an important part of the system  
design. To ensure proper, reliable operation, sufficient  
cooling of the power module is needed over the entire  
temperature range of the module. Convection cooling is  
usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
THERMAL CURVES  
HOT SPOT  
Thermal Testing Setup  
Delta’s DC/DC power modules are characterized in  
heated vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
AIRFLOW  
The following figure shows the wind tunnel  
characterization setup. The power module is mounted  
on a test PWB and is vertically positioned within the  
wind tunnel. The space between the neighboring PWB  
and the top of the power module is constantly kept at  
6.35mm (0.25’’).  
NTC RESISTOR  
Figure 22: * Hot spot& NTC resistor temperature measurement  
location  
V48SC12007(Standard) Output Current vs. Ambient Temperature and Air Velocity  
@Vin = 48V (Either Orientation)  
8
Output Current (A)  
7
PWB  
MODULE  
FACING PWB  
Natural  
Convection  
6
100LFM  
5
200LFM  
4
300LFM  
3
400LFM  
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
MEASURED BELOW  
THE MODULE  
2
500LFM  
1
50.8 (2.0”)  
600LFM  
AIR FLOW  
0
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Figure 23: Output Current vs. Ambient Temperature and Air  
Velocity @ Vin=48V (Either Orientation)  
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)  
Figure 21: Wind tunnel test setup  
9
DS_V48SC12007_08212013  
PICK AND PLACE LOCATION  
RECOMMENDED PAD LAYOUT (SMD)  
SURFACE-MOUNT TAPE & REEL  
10  
DS_V48SC12007_08212013  
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE  
Note: The temperature refers to the pin of V48SC, measured on the pin +Vout joint.  
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE  
Temp.  
Peak Temp. 240 ~ 245  
217  
200℃  
Ramp down  
max. 4/sec.  
Preheat time  
100~140 sec.  
150℃  
25℃  
Time Limited 90 sec.  
above 217℃  
Ramp up  
max. 3/sec.  
Time  
Note: The temperature refers to the pin of V48SC, measured on the pin +Vout joint.  
11  
DS_V48SC12007_08212013  
MECHANICAL DRAWING  
Surface-mount module  
Through-hole module  
Pin No.  
Name  
Function  
1
2
3
4
5
6
7
8
+Vin  
ON/OFF  
-Vin  
-Vout  
-SENSE  
TRIM  
Positive input voltage  
Remote ON/OFF  
Negative input voltage  
Negative output voltage  
Negative remote sense  
Output voltage trim  
+SENSE  
+Vout  
Positive remote sense  
Positive output voltage  
Pin Specification:(Through-hole)  
Pins 1~3,5~7  
Pins 4 & 8  
1.00mm (0.040”) diameter  
1.50mm (0.059”) diameter  
All pins are copper alloy with Matte tin over Ni plated.  
12  
DS_V48SC12007_08212013  
PART NUMBERING SYSTEM  
V
48  
S
C
120  
07  
N
R
F
A
Type of  
Product Voltage Outputs  
Input Number of Product  
Output  
Voltage  
Output  
Current  
ON/OFF  
Logic  
Pin  
Length/Type  
Option Code  
Series  
V - 1/16  
Brick  
48-  
36V~75V  
S - Single  
C-Serial  
number  
120 12V 07 7.5A N- Negative  
R - 0.170”  
N - 0.145”  
K - 0.110”  
M SMD  
A - Standard Functions  
B-no sense and trim pin  
F- RoHS 6/6  
(Lead Free)  
P- Positive  
Space- RoHS5/6  
MODEL LIST  
MODEL NAME  
INPUT  
OUTPUT  
EFF @ 100% LOAD  
V48SC12007NMFA  
V48SC12007NMFB  
V48SC12007NRFA  
36~75V  
36~75V  
36~75V  
4A  
4A  
4A  
12V  
12.1V  
12V  
7.5A  
7.5A  
7.5A  
92%  
92%  
92%  
Default remote on/off logic is negative and pin length is 0.170”  
For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office.  
CONTACT: www.deltaww.com/dcdc  
USA:  
Telephone:  
East Coast: 978-656-3993  
West Coast: 510-668-5100  
Fax: (978) 656 3964  
Email: DCDC@delta-corp.com  
Asia & the rest of world:  
Telephone: +886 3 4526107  
Ext 6220~6224  
Fax: +886 3 4513485  
Email: DCDC@delta.com.tw  
Europe:  
Phone: +31-20-655-0967  
Fax: +31-20-655-0999  
Email: DCDC@delta-es.com  
WARRANTY  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon  
request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its  
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted  
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications  
at any time, without notice.  
13  
DS_V48SC12007_08212013  

相关型号:

V48SC12007PNFA

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out
DELTA

V48SC12007PRFA

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out
DELTA

V48SC12008NRFA

High efficiency: 92.0% @ 12V/8.3A
DELTA

V48SC3R315

50W DC/DC Power Modules
DELTA

V48SC3R315NMA

50W DC/DC Power Modules
DELTA

V48SC3R315NMFA

50W DC/DC Power Modules
DELTA

V48SC3R315NNA

50W DC/DC Power Modules
DELTA

V48SC3R315NNFA

50W DC/DC Power Modules
DELTA

V48SC3R315NRA

50W DC/DC Power Modules
DELTA

V48SC3R315NRFA

50W DC/DC Power Modules
DELTA

V48SC3R320

66W DC/DC Power Modules
DELTA

V48SC3R320NMFA

66W DC/DC Power Modules
DELTA