BSPD200600Y1P [EATON]
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels;型号: | BSPD200600Y1P |
厂家: | Eaton All Rights Reserved. |
描述: | High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels 光电二极管 |
文件: | 总8页 (文件大小:1450K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
BUSSMANN
Effective April 2017
Supersedes December 2016
Technical Data 10209
SERIES
BSPD Surge Protective Devices
High capacity Type 1 and Type 2 SPDs for overvoltage
protection on switchgear and power distribution panels
Contents
Description
Page
2
Introduction
Applications
2
Features
2
Standards and certifications
Configuration
2
3
Enclosure options, dimensions, and weights
Voltage protection ratings
Specifications
3
4-5
6
Catalog number system
Technical support information
7
7
Technical Data 10209
Effective April 2017
BSPD SPDs for overvoltage protection on
switchgear and power distribution panels
Factory sealed to improve electrical safety
Introduction
All BSPD Series units are factory-sealed to eliminate arc flash
and shock hazards, as the user/installer has no chance of coming
into contact with energized parts. The units also contain no user-
serviceable parts or wire lugs that require periodic retightening to
eliminate the need for periodic maintenance.
The BSPD Series of surge protective devices are tested by
Underwriters Laboratory and Listed to UL 1449, 4th Edition to help
ensure equipment is protected with highly reliable surge protection
technology. Delta and Wye system units are available in three
configurations to increase application flexibility. The BSPD Series
is for installation external to an electrical enclosure or panelboard.
Application of BSPD Series units throughout a facility will help
ensure that equipment is protected.
Bussmann SurgePOD technology eliminates the need for
additional fusing
BSPD uses Bussmann SurgePOD modules that each contain
an internal element that safely disconnects upon reaching an
overvoltage breakdown condition.
Applications
BSPD Series units are available for common Delta and Wye system
voltages in a variety of surge current capacity ratings from 120kA
to 400kA. Available in three configurations, the BSPD Series’
features and options make it easy to specify units for many electrical
applications including service entrances, distribution switchboards,
panelboards and point-of-use. All possible combinations of product
attributes are available for ordering in the catalog number system
(see page 7).
Prewired
All BSPD units are factory wired for ease of installation. Simply
install any necessary conduit runs, mount the unit and make all
wire connections. No need for internal wiring or access to the unit’s
inside.
Compact size takes less space
Available in enclosures that are up to 50% smaller than other
products with comparable ratings the BSPD Series come in NEMA 1
and 4X enclosures that differ in size according to their surge current
capacity (Imax).
Features
•ꢀ
BSPD uses Bussmann series SurgePOD™ thermally protected
Metal Oxide Varistor (MOV) technology to safely shunt
overvoltages to ground while its thermal disconnect capability
eliminates the need for additional fusing
200kA SCCR meets the highest NEC® requirements
NEMA 1 BSPD Series units.
•ꢀ
The 120-200kA surge current capacity units are housed in a 74
square-inch enclosure that is only 3-1/2 inches deep.
•ꢀ
•ꢀ
The 300-400kA surge current capacity units are housed in a 74
square-inch enclosure that is only 6 inches deep.
•ꢀ
Models available to meet the overvoltage protection needs of
Wye and Delta electrical systems from 208 to 600 volts, 3-phase
NEMA 4X BSPD Series units.
•ꢀ
BSPD has the highest nominal discharge current (In) of 20kA
per UL 1449 4th Edition. This rating indicates the SPD’s ability to
handle a number of large-magnitude surges over a short period of
time and remain operational.
•ꢀ
The 120-200kA surge current capacity units are housed in a 108
square-inch enclosure that is only 5-3/8 inches deep.
•ꢀ
The 300-400kA surge current capacity units are housed in a 108
square-inch enclosure that is only 7-11/16 inches deep.
•ꢀ
120kA to 400kA surge current capacity (I ) ratings meet
the needs of larger switchgear and powemradx istribution panel
applications
•ꢀ
Optional Form C contact relay, EMI/RFI filtering and surge counter
available to meet additional system requirements.
•ꢀ
200kA Short-Circuit Current Rating (SCCR)
•ꢀ
NEMA 1 or NEMA 4X enclosures
•ꢀ
RoHS compliant
•ꢀ
10 year warranty
Agency information
•ꢀ
Basic, Standard and Standard with Surge Counter configurations
UL Listed, 1449 4th Edition, File E316410, Guide VZCA, CSA
Certified, Notice 516, File 243397
•ꢀ
Standard and Standard with Surge Counter configurations are also
UL Recognized, 1283 5th Edition, File E316410, Guide VZCA2, CSA
Component Acceptance, Std. C22.2, No. 8-M1986, File 243397
BSPD Series unit mounted externally to a Bussmann Quik-Spec™
Coordination Panelboard
2
Eaton.com/bussmannseries
BSPD SPDs for overvoltage protection on
switchgear and power distribution panels
Technical Data 10209
Effective April 2017
Enhanced protection status indicators
Dimensions - in (mm) and weights
Unlike many SPDs that only have single-color indicators, all BSPD
units include green and red Light Emitting Diodes (LEDs) that
indicate the true protection status for each phase.
7.28
(184.9)
1.00
(25.4)
5.27
(133.9)
If power is removed from any one phase, the unit’s LEDs continue
to indicate the protection status on that phase — regardless if power
is applied to the phase. This feature ensures proper indication.
Although many SPDs on the market have N-G surge protection,
they do not always have a means of monitoring and indicating the
protection status of that mode. All BSPD units for Wye systems also
contain green and red LED surge protection status indicators for the
Neutral-to-Ground (N-G) connection. Like the phase protection status
LEDs, the N-G protection status LEDs show the true protection
status in the N-G mode.
10.48
(266.2)
11.25
(285.8)
12.05
(306.1)
0.68
(17.3)
5.24
(133.1)
By specifying the BSPD Series, users are supplied with accurate
information concerning the surge protection status of their electrical
systems.
Ø0.20
(Ø5.1)
2.00
7.47
(189.7)
0.78
(19.8)
(50.8)
0.40
(10.2)
Configurations
The BSPD Series provides users with three configurations. These
are:
3.48
(88.4)
4.41
(112.0)
•ꢀ
Basic (UL Type 1 - can be installed in UL Type 2 locations)
Figure 1. NEMA 1, 120kA-200kA Units,
Weight = 6.8 Lbs (3.1 kg)
•ꢀ
Standard (UL Type 2)
•ꢀ
Standard with Surge Counter (UL Type 2)
1.00
(25.4)
5.47
(138.9)
The proper configuration can be selected based on application
requirements or specification.
Table 1. Configuration comparisons
12.05
(306.1)
10.48
(266.2)
11.25
(285.8)
Configuration
Standard
with
0.67
(17.0)
5.24
(133.1)
Basic
(Type 1)
Standard Surge Counter
Feature
(Type 2)
(Type 2)
2.00
Ø0.20
(Ø5.1)
Surge protection using
thermally protected MOV
technology
7.47
(189.7)
(50.8)
X
X
X
X
0.78
(19.8)
0.40
(10.2)
5.76
(146.3)
6.69
(169.9)
Green and red LED
protection status indicators
for each phase
X
X
X
X
Figure 2. NEMA 1, 300kA-400kA Units,
Weight = 13.5 Lbs (6.1 kg)
Green and red LED
protection status indicators
for the Neutral-to-Ground
protection mode (Wye
systems only)
X
Audible alarm with silence
button
X
X
X
X
Form C relay contact
EMI/RFI filtering, providing
up to 50dB of noise
attenuation from 10kHz to
100MHz
X
X
X
Surge counter with reset
button held in nonvolatile
memory
A
B
120-200kA
250-400kA
2.60 (66.0)
4.10 (104.1)
5.39 (137.0)
7.68 (195.0)
Figure 3. NEMA 4X, 120kA-400kA Units,
Weight = 120-200kA; 14.6 Lbs (6.6 kg),
250-400kA; 21.0 Lbs (9.5 kg)
Eaton.com/bussmannseries
3
Technical Data 10209
Effective April 2017
BSPD SPDs for overvoltage protection on
switchgear and power distribution panels
Voltage protection ratings
ANSI/UL 1449 4th Edition voltage protection ratings
Voltage Protection Rating (VPR) data for all units is included in the
following tables, The data varies based upon the configuration and
NEMA enclosure. VPR values for the Basic configurations are on the
left-hand side of the page. Tables on the right-hand side contain
VPR values for the Standard or Standard with Surge Counter
configurations.
NEMA 1: Basic
(cat. nos. ending with 1K)
NEMA 1: Standard or Standard w/ Surge Counter
(cat. nos. ending with 2K or 3K)
Table 2. 120-200kA
Table 5. 120-200kA
Voltage/
system
code
Protection mode
Voltage/
system
code
Protection mode
L-N
700
1200
1500
—
L-G
700
N-G
700
1200
1500
—
L-L
L-N
600
1200
1500
—
L-G
800
N-G
600
1200
1500
—
L-L
208Y
480Y
600Y
240D
480D
600D
1200
2000
2500
1000
2500
2500
208Y
480Y
600Y
240D
480D
600D
1000
1800
2500
1000
2500
2500
1200
1500
1000
2000
2500
1200
1500
1000
2500
2500
—
—
—
—
—
—
—
—
Table 3. 300kA
Table 6. 300kA
Voltage/
system
code
Protection mode
Voltage/
system
code
Protection mode
L-N
700
1200
1500
—
L-G
700
N-G
700
1200
1500
—
L-L
L-N
600
1000
1500
—
L-G
700
N-G
600
1000
1500
—
L-L
208Y
480Y
600Y
240D
480D
600D
1000
1800
2500
1000
2000
2500
208Y
480Y
600Y
240D
480D
600D
1000
1800
2500
1000
2000
2500
1200
1500
1000
1800
2500
1200
1500
1000
1800
2500
—
—
—
—
—
—
—
—
Table 4. 400kA
Table 7. 400kA
Voltage/
system
code
Protection mode
Voltage/
system
code
Protection mode
L-N
700
1200
1500
—
L-G
700
N-G
700
1200
1500
—
L-L
L-N
600
1000
1500
—
L-G
700
N-G
600
1000
1500
—
L-L
208Y
480Y
600Y
240D
480D
600D
1000
1800
2500
1000
2000
2500
208Y
480Y
600Y
240D
480D
600D
1000
1800
2500
1000
2000
2500
1200
1500
1000
1800
2500
1200
1500
1000
1800
2500
—
—
—
—
—
—
—
—
4
Eaton.com/bussmannseries
BSPD SPDs for overvoltage protection on
switchgear and power distribution panels
Technical Data 10209
Effective April 2017
NEMA 4X: Basic
(cat. nos ending with 1P)
NEMA 4X: Standard or Standard w/ Surge Counter
(cat. nos. ending with 2P or 3P)
Table 8 120–200kA
Table 11. 120–200kA
Voltage/
system
code
Protection mode
Voltage/
system
code
Protection mode
L-N
700
1200
1500
—
L-G
800
N-G
700
1000
1500
—
L-L
L-N
900
1200
1500
—
L-G
900
N-G
700
1000
1500
—
L-L
208Y
480Y
600Y
240D
480D
600D
1200
2000
2500
1000
2500
2500
208Y
480Y
600Y
240D
480D
600D
1500
2500
2500
1000
2500
2500
1200
1500
1000
2000
2500
1200
1500
1000
2500
2500
—
—
—
—
—
—
—
—
Table 9. 300kA
Table 12. 300kA
Voltage/
system
code
Protection mode
Voltage/
system
code
Protection mode
L-N
700
1200
1500
—
L-G
800
N-G
700
1200
1500
—
L-L
L-N
800
1200
1500
—
L-G
900
N-G
700
1000
1500
—
L-L
208Y
480Y
600Y
240D
480D
600D
1200
2000
2500
1000
2000
2500
208Y
480Y
600Y
240D
480D
600D
1500
2000
2500
1000
2000
2500
1200
1500
1000
1800
2500
1200
1500
1000
2000
2500
—
—
—
—
—
—
—
—
Table 10. 400kA
Table 13. 400kA
Voltage/
system
code
Protection mode
Voltage/
system
code
Protection mode
L-N
700
1200
1500
—
L-G
800
N-G
700
1200
1500
—
L-L
L-N
800
1200
1500
—
L-G
900
N-G
700
1000
1500
—
L-L
208Y
480Y
600Y
240D
480D
600D
1200
2000
2500
1000
2000
2500
208Y
480Y
600Y
240D
480D
600D
1500
2000
2500
1000
2000
2500
1200
1500
1000
1800
2500
1200
1500
1000
2000
2500
—
—
—
—
—
—
—
—
Eaton.com/bussmannseries
5
Technical Data 10209
Effective April 2017
BSPD SPDs for overvoltage protection on
switchgear and power distribution panels
5.0 Specifications
Table 14. Specifications
Description
Specification
Available system voltages
Three-phase Wye
120/208, 277/480 and 347/600
240, 480 and 600
50/60Hz
Three-phase Delta
Input power frequency
Maximum Continuous Operating Voltage (MCOV)
208Y, and 240D voltage/system type codes
480Y Voltage/system type code
600Y Voltage/system type code
480D Voltage/system type code
600D Voltage/system type code
Short-Circuit Current Rating (SCCR)
Nominal discharge current (In)
150 L-N,150 L-G, 150 N-G, 300 L-L
320 L-N, 320 L-G, 320 N-G, 640 L-L
420 L-N, 420 L-G, 420 N-G, 840 L-L
640 L-G, 640 L-L
840 L-G, 840 L-L
200kA
20kA
Surge current capacity per phase (Imax
SPD Types
)
120kA, 200kA, 300kA and 400kA ratings available
Type 1 (Basic configuration, can also be used in Type 2 applications)
Type 2 (Standard and Standard With Surge Counter configurations)
Enclosure types
Ports
NEMA 1, NEMA 4X 304 Stainless Steel
1
SPD Conductor length/gauge
48” (1.22m) 10AWG Stranded copper
Form C contact relay (Standard and Standard With Surge Counter configurations only)
Contact ratings
150Vac or 125Vdc, 1A maximum
48 inches (1.22m) / 14AWG
Lead length/gauge
Power ON, normal state; N.O. contact = OPEN, N.C. contact = CLOSED
Power OFF, fault state; N.O. contact = CLOSED, N.C. contact = OPEN
Contact logic
Power consumption
Basic configuration
208Y and 240D voltage/system type codes
0.5W
1.1W
1.3W
480Y and 480D voltage/system type codes
600Y and 600D voltage/system type codes
Standard and Standard with Surge Counter configurations
208Y and 240D voltage/system type codes
480Y, and 480D voltage/system type codes
600Y and 600D voltage/system type codes
0.6W
1.7W
2.1W
Three-phase Delta; L-G, L-L
Three-phase Wye; L-N, L-G, N-G, L-L
Protection modes
Operating temperature / humidity
Operating altitude - ft (m)
-40 to +50°C (-40 to +122°F) / 5% to 95%, non-condensing
16,000 (5000)
Up to 50dB from 10kHz to 100MHz (Standard and Standard With Surge Counter
configurations)
EMI/RFI filtering attenuation
Weight - lbs (kg)
NEMA 1: 120kA-200kA - 6.8 (3.1), 30- 400kA -13.5 (6.1) NEMA 4X: 120-200kA - 14.6 (6.6),
300-400kA - 21.0 (9.5)
- Basic, Standard and Standard with Surge Counter configurations UL Listed 1449 3rd
Edition File E316410 Guide VZCA, CSA Certified Notice 516 File 243397
- Standard and Standard with Surge Counter configurations are also UL Recognized 1283
5th Edition File E316410 Guide VZCA2, CSA Component Acceptance Std. C22.2
No. 8-M1986 File 243397
Agency information
Seismic withstand capability
Warranty
Meets or exceeds the requirements specific to I.B.C. 2006, C.B.C 2007 and U.B.C Zone 4
10 Years (see warranty statement 3A1502 for details at www.cooperbussmann.com/Surge)
6
Eaton.com/bussmannseries
BSPD SPDs for overvoltage protection on
switchgear and power distribution panels
Technical Data 10209
Effective April 2017
6.0 Catalog Number System
Table 15. BSPD part number system
All possible combinations of the BSPD attributes are available for
ordering.
BSPD 200 480D 2 K
Enclosure rating
Series
BSPD
K = NEMA 1
P = NEMA 4X
Voltage/system type code
kA Rating
per phase
208Y = 120/208 Wye (4W + G)
480Y = 277/480 Wye (4W + G)
600Y = 347/600 Wye (4W + G)
240D = 240 Delta (3W + G)
480D = 480 Delta (3W + G)
600D = 600 Delta (3W + G)
120kA
200kA
300kA
400kA
Configurations
1 = Basic
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode
2 = Standard
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode
Audible alarm with Silence button
Form C contact relay. See Table 3, Specifications
EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz
3 = Standard With Surge Counter
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode
Audible alarm with silence button
Form C contact relay
EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz
Surge counter with reset button
Technical support information
If you have any questions or need additional information, please
contact the Eaton’s Bussmann Business Application Engineers
between the hours of 7:00 a.m. and 5:00 p.m. Central Time at 855-
287-7626 (855-Bussmann) or by e-mailing FuseTech@Eaton.com.
Eaton.com/bussmannseries
7
Technical Data 10209
Effective April 2017
BSPD SPDs for overvoltage protection on
switchgear and power distribution panels
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are
by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit
distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once
a product has been selected, it should be tested by the user in all possible applications.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
For Eaton’s Bussmann series
Eaton.com
product information,
call 1-855-287-7626 or visit:
Eaton.com/bussmannseries
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton.com/bussmannseries
Eaton and Bussmann are valuable trademarks
of Eaton in the US and other countries. You
are not permitted to use the Eaton trademarks
without prior written consent of Eaton.
Follow us on social media to get the
latest product and support information.
© 2017 Eaton
All Rights Reserved
Printed in USA
CSA is a registered trademark of the Canadian
Standards Group.
Publication No. 10209 — BU-SB14678
April 2017
UL is a registered trademark of the
Underwriters Laboratories, Inc.
相关型号:
BSPD200600Y2K
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
EATON
BSPD200600Y2K
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
COOPER
BSPD200600Y2P
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
EATON
BSPD200600Y2P
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
COOPER
BSPD200600Y3K
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
EATON
BSPD200600Y3K
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
COOPER
BSPD200600Y3P
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
EATON
BSPD200600Y3P
High capacity Type 1 and Type 2 SPDs for overvoltage protection on switchgear and power distribution panels
COOPER
©2020 ICPDF网 联系我们和版权申明